Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sectionalizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

In situ recovery from residually heated sections in a hydrocarbon containing formation

Methods of treating a tar sands formation is described herein. The methods may include providing heat to a first section of a hydrocarbon layer in the formation from a plurality of heaters located in the first section of the formation. Heat is transferred from the heaters so that at least a first section of the formation reaches a selected temperature. At least a portion of residual heat from the first section transfers from the first section to a second section of the formation. At least a portion of hydrocarbons in the second section are mobilized by providing a solvation fluid and/or a pressurizing fluid to the second section of the formation.

Vinegar, Harold J↗

PROBLEM DEPENDENT DOPPLER BROADENING OF CONTINUOUS ENERGY CROSS SECTIONS IN THE KENO MONTE CARLO COMPUTER CODE

For many Monte Carlo codes cross sections are generally only created at a set of predetermined temperatures. This causes an increase in error as one moves further and further away from these temperatures in the Monte Carlo model. This paper discusses recent progress in the Scale Monte Carlo module KENO to create problem dependent, Doppler broadened, cross sections. Currently only broadening the 1D cross sections and probability tables is addressed. The approach uses a finite difference method to calculate the temperature dependent cross-sections for the 1D data, and a simple linear-logarithmic interpolation in the square root of temperature for the probability tables. Work is also ongoing to address broadening theS (alpha , beta) tables. With the current approach the temperature dependent cross sections are Doppler broadened before transport starts, and, for all but a few isotopes, the impact on cross section loading is negligible. Results can be compared with those obtained by using multigroup libraries, as KENO currently does interpolation on the multigroup cross sections to determine temperature dependent cross-sections. Current results compare favorably with these expected results.

Monte Carlo↗

Electronic assembly having sectional thermal management

The first board section comprises a switching module with heat-generating semiconductor switches associated with a first operational temperature range. The first board section has a first conductive layer of a first thickness. The second board section comprises a plurality of capacitors mounted on a second circuit board. The second board section has conductive traces for interconnecting the capacitors as a network. The capacitors are associated with a second operational temperature range that is lower than the first operational temperature range. A thermal isolation intermediary forms a barrier between, or adjoining, the first board section and the second board section, where the first board section and the second board section are spaced part from each other by the thermal isolation intermediary.

Schmit, Christopher J.↗

Reduced-Order Modeling of Multigroup Neutron Cross Sections for High-Temperature Gas-cooled Reactors

Abstract – Deterministic neutronics calculations rely on multigroup neutron cross section libraries, which consist of databases of tabulated values, used to calculate the neutron cross sections through multivariate linear interpolation. However, interpolation of the multidimensional cross section data becomes memory inefficient and time consuming as the number of tabulations increases, significantly slowing down the neutronics calculation, especially in the case of microscopic cross section libraries where every isotope (on the order of hundreds) has its own set of specific reactions and cross sections. In order to address this challenge, this work constructs efficient and robust reduced-order models (ROMs) of the multi-group cross sections to support the Griffin simulation of high-temperature gas-cooled reactors (HTGRs). The first part of the study investigates the linearity of the multigroup cross section data across isotopes, reaction types, and energy groups on pre-generated datasets for the purpose of dimensionality reduction. Secondly, a down-selection of ROM techniques is presented on representative classical machine learning (ML) techniques, including variants of linear regression, kernel-based methods, tree-based algorithms, and artificial neural networks. The selection criteria jointly consider the memory efficiency, predictive accuracy, prediction speed, and scalability in comparison to the multidimensional interpolation. Among all the ML techniques, deep neural networks (DNNs) have proven to be the best selection with sufficient accuracy, high robustness, good memory efficiency, great scalability, and superior flexibility. DNNs have been trained for all isotopes in this work and systematic Griffin testing is ongoing to ensure the feasibility of this ROM technique for predicting cross section and reducing memory requirements without a significant sacrifice in computational performance.

42 - ENGINEERING↗

Elastic Cross Sections for Electron Collisions with Molecules Relevant to Plasma Processing

Absolute electron-impact cross sections for molecular targets, including their radicals, are important in developing plasma reactors and testing various plasma processing gases. Low-energy electron collision data for these gases are sparse and only the limited cross section data are available. In this report, elastic cross sections for electron-polyatomic molecule collisions are compiled and reviewed for 17 molecules relevant to plasma processing. Elastic cross sections are essential for the absolute scale conversion of inelastic cross sections, as well as for testing computational methods. Data are collected and reviewed for elastic differential, integral, and momentum transfer cross sections and, for each molecule, the recommended values of the cross section are presented. The literature has been surveyed through early 2010.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron impact rotationally elastic total cross section for formamide

This paper reports computational results of the total cross sections for electron impact on formamide (HCONH₂) over a wide range of energies from 0.01 eV to 5 keV. Total cross sections over such a wide range are reported for the first time as the earlier reported data is up to maximum of 12 eV. Below ionization threshold of the target, we performed ab initio calculations using UK molecular R-Matrix code within static, exchange plus polarization (SEP), and close coupling approximations. Twenty eight target states are included in close coupling formalism. Total 350 channels and 2410 configuration state functions are included in the calculations. We observe a π* shape resonance at 3.41 eV and a σ* resonance at 15.3 eV as against similar resonances reported at 3.77 eV and 14.9 eV, respectively, by Goumans et al. [J. Chem. Theory Comput. 5, 217 (2009)] using SEP model. The cross sections at higher energies are evaluated using the spherical complex optical potential formalism. The two methods are found to be consistent with a smooth cross over at 18 eV. The vertical excitation energies, electronic excitation cross sections, differential cross sections, momentum transfer, and total cross sections are computed. In absence of experimental data, we compared our computed total cross sections with available other theoretical results.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular Structures and Momentum Transfer Cross Sections: The Influence of the Analyte Charge Distribution

Structure elucidation by ion mobility spectrometry-mass spectrometry methods is based on the comparison of an experimentally measured momentum transfer cross-section to cross-sections calculated for model structures. Thus, it is imperative that the calculated cross-section must be accurate. However, it is not fully understood how important it is to accurately model the charge distribution of an analyte ion when calculating momentum transfer cross-sections. Here, we calculate and compare momentum transfer cross-sections for carbon clusters that differ in mass, charge state, and mode of charge distribution, and vary temperature and polarizability of the buffer gas. Our data indicate that the detailed distribution of the ion charge density is intimately linked to the contribution of glancing collisions to the momentum transfer cross-section. The data suggest that analyte ions with molecular mass ~3 kDa or momentum transfer cross-section 400–500 Å{sup 2} would be significantly influenced by the charge distribution in nitrogen buffer gas. Our data further suggest that accurate structure elucidation on the basis of IMS-MS data measured in nitrogen buffer gas must account for the molecular charge distribution even for systems as large as C{sub 960} (~12 kDa) when localized charges are present and/or measurements are conducted under cryogenic temperatures. Finally, our data underscore that accurate structure elucidation is unlikely if ion mobility data recorded in one buffer gas is converted into other buffer gases when electronic properties of the buffer gases differ. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collisional Cross-Sections with T-Wave Ion Mobility Spectrometry without Experimental Calibration

A method for relating traveling-wave ion mobility spectrometry (TWIMS) drift times with collisional cross-sections using computational simulations is presented. This method is developed using SIMION modeling of the TWIMS potential wave and equations that describe the velocity of ions in gases induced by electric fields. The accuracy of this method is assessed by comparing the collisional cross-sections of 70 different reference ions obtained using this method with those obtained from static drift tube ion mobility measurements. The cross-sections obtained here with low wave velocities are very similar to those obtained using static drift (average difference = 0.3%) for ions formed from both denaturing and buffered aqueous solutions. In contrast, the cross-sections obtained with high wave velocities are significantly greater, especially for ions formed from buffered aqueous solutions. These higher cross-sections at high wave velocities may result from high-order factors not accounted for in the model presented here or from the protein ions unfolding during TWIMS. Results from this study demonstrate that collisional cross-sections can be obtained from single TWIMS drift time measurements, but that low wave velocities and gentle instrument conditions should be used in order to minimize any uncertainties resulting from high-order effects not accounted for in the present model and from any protein unfolding that might occur. Thus, the method presented here eliminates the need to calibrate TWIMS drift times with collisional cross-sections measured using other ion mobility devices. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Collision Cross-Sections from FTICR Linewidth Measurements: Improvements in Theory and Experiment

Two corrections to the equation used in the cross-sectional areas by Fourier transform ion cyclotron resonance (“CRAFTI”) technique are identified. In CRAFTI, ion collision cross-sections are obtained from the pressure-dependent ion linewidths in Fourier transform mass spectra. The effects of these corrections on the accuracy of the cross-sections obtained using the CRAFTI technique are evaluated experimentally using the 20 biogenic amino acids and several crown ether complexes with protonated alkyl monoamines. Good absolute agreement is obtained between the CRAFTI cross-sections and the corresponding cross-sections obtained using both static drift ion mobility spectrometry and computational simulations. These results indicate that the CRAFTI cross-sections obtained using the updated equation presented here are quantitatively descriptive of the size and shape of the gas-phase ions. Cross-sections that differ by less than 3% are measured for the isobaric isomers n-butylamine and tert-butylamine complexed with the crown ethers. This level of precision is similar to what has been achieved previously using traveling wave ion mobility devices. These results indicate that CRAFTI can be used to probe subtle structural differences between ions with approximately the same precision as that achieved in traveling wave ion mobility devices. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculations of photo-induced X-ray production cross-sections in the energy range 1–150 keV and average fluorescence yields for Zn, Cd and Hg

In this paper, we calculate the K-, L- and M-shells X-ray production, and X-ray fluorescence cross-sections after photo-induced ionization, for Zn, Cd, and Hg, and for incident photon energy range from 1 to 150 keV. For this purpose, the corresponding average fluorescence yields for Zn, Cd, and Hg as well as the photoionization cross-sections were calculated using the Dirac–Fock method. Subshell fluorescence, intrashell and intershell yields are obtained consistently from radiative and radiationless transitions calculated in the exact same method. A comprehensive account of the relations between the X-ray production, X-ray fluorescence cross-sections and the photoionization cross-sections and these yields is presented. Comparisons are made with results from other authors. The obtained values for the photoionization cross-sections are in good agreement with the widely used data of Scofield in the studied energy range. However our results for the X-ray fluorescence cross sections seem to favor some data relatively to others. The energy dependence of the average fluorescence yields is discussed, in particular, the reliability of extrapolated data for lighter elements from measurements and calculations in heavier elements above the inner shell absorption edges is questioned. Tabulated data on photoionization and X-ray production cross-sections are presented for the incident photon energy range 1–150 keV in steps of 1 keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Methods for the Determination of Total Radiative Thermal Neutron Capture Cross Sections

Precise gamma-ray thermal neutron capture cross sections have been measured at the Budapest Reactor for all elements with Z = 1-83,92 except for He and Pm. These measurements and additional data from the literature been compiled to generate the Evaluated Gamma-ray Activation File (EGAF), which is disseminated by LBNL and the IAEA. These data are nearly complete for most isotopes with Z<20 so the total radiative thermal neutron capture cross sections can be determined directly from the decay scheme. For light isotopes agreement with the recommended values is generally satisfactory although large discrepancies exist for {sup 11}B, {sup 12,13}C, {sup 15}N, {sup 28,30}Si, {sup 34}S, {sup 37}Cl, and {sup 40,41}K. Neutron capture decay data for heavier isotopes are typically incomplete due to the contribution of unresolved continuum transitions so only partial radiative thermal neutron capture cross sections can be determined. The contribution of the continuum to the neutron capture decay scheme arises from a large number of unresolved levels and transitions and can be calculated by assuming that the fluctuations in level densities and transition probabilities are statistical. We have calculated the continuum contribution to neutron capture decay for the palladium isotopes with the Monte Carlo code DICEBOX. These calculations were normalized to the experimental cross sections deexciting low excitation levels to determine the total radiative thermal neutron capture cross section. The resulting palladium cross sections values were determined with a precision comparable to the recommended values even when only one gamma-ray cross section was measured. The calculated and experimental level feedings could also be compared to determine spin and parity assignments for low-lying levels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of electron impact collisional excitation cross sections of Ni to Ge-like gold

We have measured the collisional excitation cross sections for the 3d→4f and 3d→5f excitations in Au ions near the Ni-like charge state by using beam plasmas created in the Livermore electron beam ion trap EBIT-I. The cross sections have been experimentally determined at approximately 1, 2 and 3 keV above the threshold energy, ET, for the 3d→4f excitations (ET ~2.5 keV) and at approximately 0.1, 1 and 2 keV above the threshold energy for the 3d→5f excitations (ET ~3.3 keV). The cross section measurements were made possible by using the GSFC x-ray microcalorimeter at the Livermore EBIT facility. The absolute cross sections are determined from the ratio of the intensity of the collisionally excited bound-bound transitions to the intensity of the radiative recombination lines produced in EBIT-I plasmas. The effects of polarization and Auger decay channels are accounted for in the cross section determination. Measured cross sections are compared with those from HULLAC, DWS and FAC calculations. Finally, the measurements demonstrate that some errors exist in the calculated excitation cross sections.

74 ATOMIC AND MOLECULAR PHYSICS↗

Deep Learning for Multigroup Cross-Section Representation in Two-Step Core Calculations

Here we investigate using deep learning, a type of machine-learning algorithm employing multiple layers of artificial neurons, for the mathematical representation of multigroup cross sections for use in the Griffin reactor multiphysics code for two-step deterministic neutronics calculations. A three-dimensional fuel element typical of a high-temperature gas reactor as well as a two-dimensional sodium-cooled fast reactor lattice are modeled using the Serpent Monte Carlo code, and multigroup macroscopic cross sections are generated for various state parameters to produce a training data set and a separate validation data set. A fully connected, feedforward neural network is trained using the open-source PyTorch machine-learning framework, and its accuracy is compared against the standard piecewise linear interpolation model. Additionally, we provide in this work a generic technique for propagating the cross-section model errors up to the k eff using sensitivity coefficients with the first-order uncertainty propagation rule. Quantifying the eigenvalue error due to the cross-section regression errors is especially practical for appropriately selecting the mathematical representation of the cross sections. We demonstrate that the artificial neural network model produces lower errors and therefore enables better accuracy relative to the piecewise linear model when the cross sections exhibit nonlinear dependencies; especially when a coarse grid is employed, where the errors can be halved by the artificial neural network. However, for linearly dependent multigroup cross sections as found for the sodium-cooled fast reactor case, a simpler linear regression outperforms deeper networks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal neutron capture cross sections of the palladium isotopes

Precise thermal neutron capture {gamma}-ray cross sections {sigma}{sub {gamma}} were measured for all elements with Z=1-83,90, and 92, for He and Pm, at the Budapest Reactor. These data were evaluated with additional information from the literature to generate the Evaluated Gamma-ray Activation File (EGAF). Isotopic radiative neutron cross sections can be deduced from the total transition cross section feeding the ground state, {sigma}{sub 0}={sigma}{sigma}{sub {gamma}}(GS) if the decay scheme is complete. The EGAF file contains partial {gamma}-ray cross sections for all stable palladium isotopes. None of these decay schemes are complete, although in each case transitions de-exciting low-lying levels are known. We have performed Monte Carlo simulations of the palladium thermal neutron capture decay schemes using the computer code DICEBOX. The simulated populations of low low-lying levels are normalized to the measured {sigma}{sub {gamma}} values from EGAF and the total radiative neutron cross section {sigma}{sub 0} is obtained. The {sigma}{sub 0} values derived for the palladium isotopes agree well with previous measurements and were in several cases more precise. Complementary use of {gamma}-ray cross-section data and Monte Carlo calculations has proven effective in determining both the palladium total radiative cross sections and new nuclear structure information.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast, accurate photon beam accelerator modeling using BEAMnrc: A systematic investigation of efficiency enhancing methods and cross-section data

In this work, an investigation of efficiency enhancing methods and cross-section data in the BEAMnrc Monte Carlo (MC) code system is presented. Additionally, BEAMnrc was compared with VMC++, another special-purpose MC code system that has recently been enhanced for the simulation of the entire treatment head. BEAMnrc and VMC++ were used to simulate a 6 MV photon beam from a Siemens Primus linear accelerator (linac) and phase space (PHSP) files were generated at 100 cm source-to-surface distance for the 10x10 and 40x40 cm{sup 2} field sizes. The BEAMnrc parameters/techniques under investigation were grouped by (i) photon and bremsstrahlung cross sections, (ii) approximate efficiency improving techniques (AEITs), (iii) variance reduction techniques (VRTs), and (iv) a VRT (bremsstrahlung photon splitting) in combination with an AEIT (charged particle range rejection). The BEAMnrc PHSP file obtained without the efficiency enhancing techniques under study or, when not possible, with their default values (e.g., EXACT algorithm for the boundary crossing algorithm) and with the default cross-section data (PEGS4 and Bethe-Heitler) was used as the ''base line'' for accuracy verification of the PHSP files generated from the different groups described previously. Subsequently, a selection of the PHSP files was used as input for DOSXYZnrc-based water phantom dose calculations, which were verified against measurements. The performance of the different VRTs and AEITs available in BEAMnrc and of VMC++ was specified by the relative efficiency, i.e., by the efficiency of the MC simulation relative to that of the BEAMnrc base-line calculation. The highest relative efficiencies were {approx}935 ({approx}111 min on a single 2.6 GHz processor) and {approx}200 ({approx}45 min on a single processor) for the 10x10 field size with 50 million histories and 40x40 cm{sup 2} field size with 100 million histories, respectively, using the VRT directional bremsstrahlung splitting (DBS) with no electron splitting. When DBS was used with electron splitting and combined with augmented charged particle range rejection, a technique recently introduced in BEAMnrc, relative efficiencies were {approx}420 ({approx}253 min on a single processor) and {approx}175 ({approx}58 min on a single processor) for the 10x10 and 40x40 cm{sup 2} field sizes, respectively. Calculations of the Siemens Primus treatment head with VMC++ produced relative efficiencies of {approx}1400 ({approx}6 min on a single processor) and {approx}60 ({approx}4 min on a single processor) for the 10x10 and 40x40 cm{sup 2} field sizes, respectively. BEAMnrc PHSP calculations with DBS alone or DBS in combination with charged particle range rejection were more efficient than the other efficiency enhancing techniques used. Using VMC++, accurate simulations of the entire linac treatment head were performed within minutes on a single processor. Noteworthy differences ({+-}1%-3%) in the mean energy, planar fluence, and angular and spectral distributions were observed with the NIST bremsstrahlung cross sections compared with those of Bethe-Heitler (BEAMnrc default bremsstrahlung cross section). However, MC calculated dose distributions in water phantoms (using combinations of VRTs/AEITs and cross-section data) agreed within 2% of measurements. Furthermore, MC calculated dose distributions in a simulated water/air/water phantom, using NIST cross sections, were within 2% agreement with the BEAMnrc Bethe-Heitler default case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Many Muons Do We Need to Store in a Ring For Neutrino Cross-Section Measurements?

Analytical estimate of the number of muons that must decay in the straight section of a storage ring to produce a neutrino & anti-neutrino beam of sufficient intensity to facilitate cross-section measurements with a statistical precision of 1%. As we move into the era of precision long-baseline {nu}{sub {mu}} {yields} {nu}{sub e} and {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e} measurements there is a growing need to precisely determine the {nu}{sub e} and {bar {nu}}{sub e} cross-sections in the relevant energy range, from a fraction of 1 GeV to a few GeV. This will require {nu}{sub e} and {bar {nu}}{sub e} beams with precisely known fluxes and spectra. One way to produce these beams is to use a storage ring with long straight sections in which muon decays ({mu}{sup -} {yields} e{sup -}{nu}{sub {mu}}{bar {nu}}{sub e} if negative muons are stored, and {nu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} if positive muons are stored) produce the desired beam. The challenge is to capture enough muons in the ring to obtain useful neutrino and anti-neutrino fluxes. Early proposals to use a muon storage ring for neutrino oscillation experiments were based upon injecting 'high energy' charged pions into the ring which then decayed to create stored muons. These proposals were hampered by lack of sufficient intensity to pursue the physics. The Neutrino Factory proposal in 1997 was designed to fix this problem by using a Muon Collider class 'low energy' muon source to capture many more pions at low energy, allow them to decay in an external decay channel, manipulate their phase space to capture as many muons as possible within the acceptance of an accelerator, and then accelerate to the energy of choice before injecting into a specially designed ring with long straight sections. All this technology would do a wonderful job in fixing the intensity problem, but at a price that excludes this solution from being realized in the short term. The question that we are now faced with is whether the older, lower intensity 'parasitic' muon storage ring based on 'high energy' pion decays can, with suitable modification, produce sufficient intensity to measure the desired cross-sections. Fortunately, the intensity requirements for cross-section measurements are less demanding than the corresponding requirements for oscillation measurements, so there is hope. To fuel the discussion, in this note we consider the design goal: how many muons do we need to store?

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surrogate Measurements of Actinide (n,2n) Cross Sections with NeutronSTARS

Directly measuring (n,2n) cross sections on short-lived actinides presents a number of experimental challenges. The surrogate reaction technique is an experimental method for measuring cross sections on short-­lived isotopes, and it provides a unique solution for measuring (n,2n) cross sections. This technique involves measuring a charged-­particle reaction cross section, where the reaction populates the same compound nucleus as the reaction of interest. To perform these surrogate (n,2n) cross section measurements, a silicon telescope array has been placed along a beam line at the Texas A&M University Cyclotron Institute, which is surrounded by a large tank of gadolinium-doped liquid scintillator, which acts as a neutron detector. The combination of the charge-particle and neutron-detector arrays is referred to as NeutronSTARS. In the analysis procedure for calculating the (n,2n) cross section, the neutron detection efficiency and time structure plays an important role. Due to the lack of availability of isotropic, mono-energetic neutron sources, modeling is an important component in establishing this efficiency and time structure. This report describes the NeutronSTARS array, which was designed and commissioned during this project. It also describes the surrogate reaction technique, specifically referencing a 235 U(n,2n) commissioning measurement that was fielded during the past year. Advanced multiplicity analysis techniques have been developed for this work, which should allow for efficient analysis of 241 Pu(n,2n) and 239 Pu(n,2n) cross section measurements

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Neutrino-Nucleon Neutral-Current Elastic Scattering Cross-section at SciBooNE

In this thesis, results of neutrino-nucleon neutral current (NC) elastic scattering analysis are presented. Neutrinos interact with other particles only with weak force. Measurement of cross-section for neutrino-nucleon reactions at various neutrino energy are important for the study of nucleon structure. It also provides data to be used for beam flux monitor in neutrino oscillation experiments. The cross-section for neutrino-nucleon NC elastic scattering contains the axial vector form factor G A (Q 2 ) as well as electromagnetic form factors unlike electromagnetic interaction. G A is propotional to strange part of nucleon spin (Δs) in Q 2 → 0 limit. Measurement of NC elastic cross-section with smaller Q 2 enables us to access Δs. NC elastic cross-sections of neutrino-nucleon and antineutrino-nucleon were measured earlier by E734 experiment at Brookheaven National Laboratory (BNL) in 1987. In this experiment, cross-sections were measured in Q 2 > 0.4 GeV 2 region. Result from this experiment was the only published data for NC elastic scattering cross-section published before our experiment. SciBooNE is an experiment for the measurement of neutrino-nucleon scattering cross-secitons using Booster Neutrino Beam (BNB) at FNAL. BNB has energy peak at 0.7 GeV. In this energy region, NC elastic scattering, charged current elastic scattering, charged current pion production, and neutral current pion production are the major reaction branches. SciBar, electromagnetic calorimeter, and Muon Range Detector are the detectors for SciBooNE. The SciBar consists of finely segmented scintillators and 14336 channels of PMTs. It has a capability to reconstruct particle track longer than 8 cm and separate proton from muons and pions using energy deposit information. Signal of NC elastic scattering is a single proton track. In vp → vp process, the recoil proton is detected. On the other hand, most of vn → vn is invisible because there are only neutral particles in final state, but sometimes recoil neutron is scattered by proton and recoil proton is detected. Signal of this event is also single proton track. Event selection for the single proton track events using geometrical and dE/dx information of reconstructed track is performed. After the event selection, NC elastic scattering data sample is obtained. They includes vp → vp and vn → vn is obtained. Absolute cross-section as a function of Q 2 is evaluated from this NC elastic scattering data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗