Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A new apparatus for electron tomography in the scanning electron microscope

The three-dimensional reconstruction of a microscopic specimen has been obtained by applying the tomographic algorithm to a set of images acquired in a Scanning Electron Microscope. This result was achieved starting from a series of projections obtained by stepwise rotating the sample under the beam raster. The Scanning Electron Microscope was operated in the scanning-transmission imaging mode, where the intensity of the transmitted electron beam is a monotonic function of the local mass-density and thickness of the specimen. The detection strategy has been implemented and tailored in order to maintain the projection requirement over the large tilt range, as required by the tomographic workflow. A Si-based electron detector and an eucentric-rotation specimen holder have been specifically developed for the purpose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Direct observation of enhanced emission sites in nitrogen implanted hybrid structured ultrananocrystalline diamond films

A hybrid-structured ultrananocrystalline diamond (h-UNCD) film, synthesized on Si-substrates by a two-step microwave plasma enhanced chemical vapour deposition (MPECVD) process, contains duplex structure with large diamond aggregates evenly dispersed in a matrix of ultra-small grains ({approx}5 nm). The two-step plasma synthesized h-UNCD films exhibit superior electron field emission (EFE) properties than the one-step MPECVD deposited UNCD films. Nitrogen-ion implantation/post-annealing processes further improve the EFE properties of these films. Current imaging tunnelling spectroscopy in scanning tunnelling spectroscopy mode directly shows increased density of emission sites in N implanted/post-annealed h-UNCD films than as-prepared one. X-ray photoelectron spectroscopy measurements show increased sp{sup 2} phase content and C-N bonding fraction in N ion implanted/post-annealed films. Transmission electron microscopic analysis reveals that the N implantation/post-annealing processes induce the formation of defects in the diamond grains, which decreases the band gap and increases the density of states within the band gap of diamond. Moreover, the formation of nanographitic phase surrounding the small diamond grains enhanced the conductivity at the diamond grain boundaries. Both of the phenomena enhance the EFE properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dielectric, electrical and magnetoelectric characterization of (x)Ni{sub 0.8}Zn{sub 0.2}Fe{sub 2}O{sub 4} + (1 - x)Pb{sub 0.93}La{sub 0.07}(Zr{sub 0.60}Ti{sub 0.40})O{sub 3} composites

The structural, electrical, dielectric, magnetic and magnetoelectric properties of (x)Ni{sub 0.8}Zn{sub 0.2}Fe{sub 2}O{sub 4} + (1 - x)Pb{sub 0.93}La{sub 0.07}(Zr{sub 0.60}Ti{sub 0.40})O{sub 3} (x = 0, 0.15, 0.30, 0.45 and 1) have been studied by means of various experimental techniques. Polycrystalline samples of this series have been prepared by the double sintering ceramic method. X-ray diffraction data analysis revealed purity of the composites. Microstructural analysis using scanning electron microscopy mode depicts the presence of two phases in contact with each other. Dielectric properties were studied at and well above room temperature. Temperature dependent variation of the dielectric constant show diffused phase transition which can be well described by fitting the Lorentz-type relation, {epsilon}{sub A}/{epsilon}=1+(T-T{sub A}){sup 2}/2{delta}{sub A}{sup 2}. Observation of well-saturated ferroelectric hysteresis loop and magnetic hysteresis loop for composites indicates that ferroelectric and magnetic ordering exist simultaneously at room temperature. The static value of magneto electric voltage coefficient ({alpha}{sub E}) has been studied as a function of magnetic field at room temperature for all the composites. The maximum value of {alpha}{sub E} is 7.53 mV/(cm Oe) for 85% PLZT-15% NZFO composites.

36 MATERIALS SCIENCE↗

Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Do Maximum Intensity Projection Images Truly Capture Tumor Motion?

Purpose: For the treatment of patients with lung cancer, internal target volume frequently is determined by using maximum intensity projection (MIP) images generated by means of four-dimensional computed tomography (4D-CT). To check the accuracy of MIPs for various target motions, especially for targets moving irregularly, we performed phantom studies using a programmable dynamic lung phantom. Methods and Materials: A custom-built programmable lung phantom was used to simulate irregular target motions along the superior-inferior direction. After scanning in helical mode using 4D-CT, reconstructed phase and MIP images were imported into the Pinnacle 8.0 treatment planning system for image analysis. Results: For all regular periodic target motions with constant amplitude and period, the measured MIP target span along the superior-inferior direction was accurate within 2-3 mm of the real target motion span. For irregular target motions with varying amplitudes and periods, the measured MIP target span systematically underrepresented the real range of target motion by more than 1 cm in some cases. The difference between measured MIP target span and real target span decreased as the target moved faster. We associate these discrepancies with the fact that current reconstruction algorithms of commercial 4D-CT are based on phase binning. Conclusions: According to our phantom measurements, MIP accurately reflects the range of target motion for regular target motion. However, it generally underestimates the range of target motion when the motion is irregular in amplitude and periodicity. Clinical internal target volume determination using MIP requires caution, especially when there is breathing irregularity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consequences and Control of Multiscale Order/Disorder in Chiral Magnetic Textures

Transition metal intercalated transition metal dichalcogenides (TMDs) are promising platforms for next-generation spintronic devices based on their wide range of electronic and magnetic phases, which can be tuned by varying the host lattice or intercalant’s identity, stoichiometry, or spatial order. Some of these compounds host a chiral magnetic phase in which the helical winding of magnetic moments propagates along a high-symmetry crystalline axis. Previous studies have demonstrated that variation in intercalant concentrations can have a dramatic effect on the formation of chiral domains and ensemble magnetic properties. However, a systematic and comprehensive study of how atomic-scale order and disorder impact these chiral magnetic textures is so far lacking. Here, we leverage a combination of imaging modes in the (scanning) transmission electron microscope (S/TEM) to directly probe (dis)order across multiple length scales and show how subtle changes in the atomic lattice can tune the mesoscale spin textures and bulk magnetic response in Cr 1/3 NbS 2 , with direct implications for the fundamental understanding and technological implementation of such compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong interplay between stripe spin fluctuations, nematicity and superconductivity in FeSe

In iron-based superconductors the interactions driving the nematic order (that breaks four-fold rotational symmetry in the iron plane) may also mediate the Cooper pairing. The experimental determination of these interactions, which are believed to depend on the orbital or the spin degrees of freedom, is challenging because nematic order occurs at, or slightly above, the ordering temperature of a stripe magnetic phase. In this paper, we study FeSe—which exhibits a nematic (orthorhombic) phase transition at T s = 90 K without antiferromagnetic ordering—by neutron scattering, finding substantial stripe spin fluctuations coupled with the nematicity that are enhanced abruptly on cooling through T s . A sharp spin resonance develops in the superconducting state, whose energy (~4 meV) is consistent with an electron–boson coupling mode revealed by scanning tunnelling spectroscopy. The magnetic spectral weight in FeSe is found to be comparable to that of the iron arsenides. Finally, our results support recent theoretical proposals that both nematicity and superconductivity are driven by spin fluctuations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of zonal flows in trapped electron mode turbulence through nonlinear gyrokinetic particle and continuum simulation

Trapped electron mode (TEM) turbulence exhibits a rich variety of collisional and zonal flow physics. This work explores the parametric variation of zonal flows and underlying mechanisms through a series of linear and nonlinear gyrokinetic simulations, using both particle-in-cell and continuum methods. A new stability diagram for electron modes is presented, identifying a critical boundary at {eta}{sub e}=1, separating long and short wavelength TEMs. A novel parity test is used to separate TEMs from electron temperature gradient driven modes. A nonlinear scan of {eta}{sub e} reveals fine scale structure for {eta}{sub e} > or approx. 1, consistent with linear expectation. For {eta}{sub e}<1, zonal flows are the dominant saturation mechanism, and TEM transport is insensitive to {eta}{sub e}. For {eta}{sub e}>1, zonal flows are weak, and TEM transport falls inversely with a power law in {eta}{sub e}. The role of zonal flows appears to be connected to linear stability properties. Particle and continuum methods are compared in detail over a range of {eta}{sub e}=d ln T{sub e}/d ln n{sub e} values from zero to five. Linear growth rate spectra, transport fluxes, fluctuation wavelength spectra, zonal flow shearing spectra, and correlation lengths and times are in close agreement. In addition to identifying the critical parameter {eta}{sub e} for TEM zonal flows, this paper takes a challenging step in code verification, directly comparing very different methods of simulating simultaneous kinetic electron and ion dynamics in TEM turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Registration of Alfven resonances in TCABR tokamak by the scanning reflectometer at sideband frequencies

A frequency scanning O-mode reflectometer was used for studies of plasma density oscillations during local Alfven wave (LAW) excitation in the Tokamak Chauffage Alfven Bresilien (TCABR) at the frequency f{sub A}= 5 MHz. It was found that the spectrum of the reflectometer output signal, which consists mainly of the ''beat'' frequency f{sub B}, is modified by the LAW excitation, and two additional frequency peaks appear, which are symmetrical in relation to the LAW excitation frequency f=f{sub A}{+-}f{sub B}. This result opens the possibility to improve the efficiency of studying the LAW induced density oscillations. The symmetry of these frequency peaks yields the possibility of finding the microwave frequency at which the reflectometer cutoff layer coincides with radial position of the LAW resonance zone in the TCABR tokamak.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-crystal wavelength dispersive x-ray spectrometer

A multi-crystal wavelength dispersive hard x-ray spectrometer with high-energy resolution and large solid angle collection is described. The instrument is specifically designed for time-resolved applications of x-ray emission spectroscopy (XES) and x-ray Raman scattering (XRS) at X-ray Free Electron Lasers (XFEL) and synchrotron radiation facilities. It also simplifies resonant inelastic x-ray scattering (RIXS) studies of the whole 2d RIXS plane. The spectrometer is based on the Von Hamos geometry. This dispersive setup enables an XES or XRS spectrum to be measured in a single-shot mode, overcoming the scanning needs of the Rowland circle spectrometers. In conjunction with the XFEL temporal profile and high-flux, it is a powerful tool for studying the dynamics of time-dependent systems. Photo-induced processes and fast catalytic reaction kinetics, ranging from femtoseconds to milliseconds, will be resolvable in a wide array of systems circumventing radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution planar electron beam induced current in bulk diodes using high-energy electrons

Understanding the impact of high-energy electron radiation on device characteristics remains critical for the expanding use of semiconductor electronics in space-borne applications and other radiation harsh environments. Here in this paper, we report on in situ measurements of high-energy electron radiation effects on the hole diffusion length in low threading dislocation density homoepitaxial bulk n-GaN Schottky diodes using electron beam induced current (EBIC) in high-voltage scanning electron microscopy mode. Despite the large interaction volume in this system, quantitative EBIC imaging is possible due to the sustained collimation of the incident electron beam. This approach enables direct measurement of electron radiation effects without having to thin the specimen. Using a combination of experimental EBIC measurements and Monte Carlo simulations of electron trajectories, we determine a hole diffusion length of 264 ± 11 nm for n-GaN. Irradiation with 200 kV electron beam with an accumulated dose of 24 × 10 16 electrons cm -2 led to an approximate 35% decrease in the minority carrier diffusion length.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parameter dependencies of the separatrix density in low triangularity L-mode and H-mode JET-ILW plasmas

Abstract The midplane electron separatrix density, n e,sep , in JET-ILW L-mode and H-mode low triangularity deuterium fuelled plasmas exhibits a strong explicit dependence on the averaged outer divertor target electron temperature, n e,sep ∼ T e,ot −1/2 . This dependence is reproduced by analytic reversed two point model (rev-2PM), and arises from parallel pressure balance, as well as the ratio of the power and momentum volumetric loss factors, (1 − f cooling )/(1 − f mom-loss ). Quantifying the influence of the (1 − f cooling ) and (1 − f mom-loss ) loss factors on n e,sep has been enabled by measurement estimates of these quantities from L-mode density (fueling) ramps in the outer horizontal, VH(C), and vertical target, VV, divertor configurations. Rev-2PM n e,sep estimates from the extended H-mode and more limited L-mode datasets are recovered to within ±25% of the measurements, with a scaling factor applied to account for use of T e,ot , an averaged quantity, rather than flux tube resolved target values. Both the (1 − f cooling ) and (1 − f mom-loss ) trends and recovery of n e,sep using the rev-2PM formatting are reproduced in EDGE2D-EIRENE L-mode-like and H-mode-like density scan simulations. The general lack of a divertor configuration effect in the JET-ILW n e,sep trends can be attributed to a significant influence of main chamber recycling, which has been shown in the EDGE2D-EIRENE results to moderate n e,sep with respect to changes in divertor neutral leakage imposed by changes in the divertor configuration. The unified n e,sep vs T e,ot trends can, however, be broken if large modifications to the divertor geometry (e.g. complete removal of the outer divertor baffle structure) are introduced in the model. The more pronounced high-field side high density region formation in the VH(C) configuration with reduced clearance to the separatrix does not appear to have a significant influence on the outer midplane separatrix and pedestal parameters when mapped to T e,ot , although conditions at the inner midplane could not be assessed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study and Considerations of Nanometer and Nano-radian Surface Profiler

A Nanometer and Nano-radian Surface Profiler (NSP) is under development at Brookhaven National Laboratory. Nanometer and nano-radian accuracy is required for newest state-of-the-art synchrotron radiation optics and highprecision optical measurement. This test accuracy must be maintained in larger angle test range. In order to reach this accuracy we have to remove all error sources as much as possible or to reduce them to nano-radian level. We present the approaches in optimized optical system designing, scanning optical head mode selection, non-tilted reference method, quality control of optical components, and temperature stabilization. Some considerations and preliminary measurements are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An investigation into factors affecting the precision of CT radiation dose profile width measurements using radiochromic films

Purpose: To investigate the impact of x-ray beam energy, exposure intensity, and flat-bed scanner uniformity and spatial resolution on the precision of computed tomography (CT) beam width measurements using Gafchromic XR-QA2 film and an off-the-shelf document scanner. Methods: Small strips of Gafchromic film were placed at isocenter in a CT scanner and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mA s), and nominal beam widths (1.25, 5, and 10 mm). The films were scanned in reflection mode on a Ricoh MP3501 flat-bed document scanner using several spatial resolution settings (100 to 400 dpi) and at different locations on the scanner bed. Reflection measurements were captured in digital image files and radiation dose profiles generated by converting the image pixel values to air kerma through film calibration. Beam widths were characterized by full width at half maximum (FWHM) and full width at tenth maximum (FWTM) of dose profiles. Dependences of these parameters on the above factors were quantified in percentage change from the baselines. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within 4.5% and 7.6%, respectively. Increasing scanner spatial resolution significantly increased the uncertainty in both FWHM and FWTM, with FWTM affected by almost 8 times more than FWHM (48.7% vs 6.5%). When uncalibrated dose profiles were used, FWHM and FWTM were over-estimated by 11.6% and 7.6%, respectively. Narrower beam width appeared more sensitive to the film calibration than the wider ones (R{sup 2} = 0.68 and 0.85 for FWHM and FWTM, respectively). The global and maximum local background variations of the document scanner were 1.2%. The intrinsic film nonuniformity for an unexposed film was 0.3%. Conclusions: Measurement of CT beam widths using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. With proper film calibration and scanner resolution setting, it can provide adequate precision for meeting ACR and manufacturer’s tolerances for the measurement of CT dose profiles.

60 APPLIED LIFE SCIENCES↗

SU-E-T-206: Comparison of EBT and EBT3 RadioChromic Films in Radiation Field of Parotid Cancer Radiotherapy

Purpose: The aim of the current study is to compare EBT and EBT3 RadioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer. Methods: The calibrations of EBT and EBT3 films were performed with the same setups for doses ranging from 0.2 Gy to 5 Gy using 6 MV photon beam of a Siemens Primus linac. These films were scanned in color mode (RGB) by a Microtek (1000XL) scanner and the red color channel data was extracted. Treatment planning for parotid cancer radiation therapy was performed on a RANDO phantom. Skin dose was measured at different points in the right anterior oblique (RAO) and right posterior oblique (RPO) fields by EBT and EBT3 films. Results: Dosimetry was performed with the same conditions for the two film types for calibration and in-phantom in parotid cancer radiotherapy. The measured net optical density (NOD) in EBT film was in some extent higher than that from EBT3 film. The minimum difference between these two films under calibration conditions was about 2.9% (for 0.2 Gy). However, the maximum difference was 35.5% (for 0.5 Gy). In the therapeutic fields of parotid cancer radiotherapy at different points, the measured dose from EBT film was higher than the EBT3 film. In these fields the minimum and maximum measured dose differences were 16.0% and 25.5%, respectively. Conclusion: With the same irradiation and reading conditions, EBT film demonstrates higher NOD than the EBT3 film. This effect may be related to the higher sensitivity of EBT film over EBT3 film. However, the obtained dose differences between these two films in low dose range can be due to the differences in fitting functions applied following the calibration process.

60 APPLIED LIFE SCIENCES↗

SU-E-T-330: Dosimetric Impact of Intrafraction Respiratory Motion On Lung SBRT Treatment Using Cyberknife 0-View Tracking Mode

Purpose: To investigate the influence of respiratory motion on the delivered dose in lung stereotactic body radiotherapy (SBRT) using Cyberknife (CK) 0-View tracking mode. Methods: CT scans at inspiration and expiration of an anthropomorphic motion phantom were fused base on the spine and an internal target volume (ITV) was created. A 5mm expansion around the ITV resulted in the planning target volume. Three CK plans were generated in Accuray MultiPlan using Lung Optimization Tracking 0-View technique with the minimum MU per beam set to (a) 5MU, (b) 15MU and (c) 30MU, respectively. Doses were calculated on the expiration CT using Monte-Carlo algorithm. Each plan was delivered 5 times with a range of different starting phases in the respiratory cycle to assess the dose variation due to interplay effect. The delivered dose was measured with EBT3 Gafchromic film which was inserted in the moving target of the phantom. The target motion range is 3 cm in superior-inferior (SI) direction with the breathing period of 5 seconds. Results: The gamma analysis (5%/2mm) of the dose with the films in the transverse plane resulted in average passing rate of 95.5±4.1%, 96.7±2.6%, and 96.2±2.5% for plan (a), (b), and (c), respectively. For the sagittal films, the average passing rate was 91.1±4.9%, 92.1±3.6%, and 92.3±2.9% for the three plans, respectively. The disagreement between measurement and dose calculations were mostly on the target edges in SI direction. The mean measured versus calculated dose differences at the edge of target in SI direction were (a) 3.9±4.8%, (b) 2.4±3.3%, and (c) 2.2±3.2% for the three plans, respectively. Conclusions: The plans with low-MU beams (below 10MU) tend to cause slightly larger dose variation. However in terms of target coverage, the overall clinical dosimetric impact of the intrafraction respiratory motion in lung SBRT is insignificant when averaged over 3∼5 fractions.

60 APPLIED LIFE SCIENCES↗

SU-F-T-568: QA of a Multi-Target Multi-Dose VMAT SRS

Purpose: To, experimentally, corroborated the prescribed doses utilizing dosimeters (e.g. films and TLDs) that can provide high spatial resolution, allow dose measurement of multiple targets at once, and provide accurate dosimetric results. Methods: A single-isocenter 6FFF SRS VMAT plan consisting of one 358° arc at 0° couch angle and four 179° arcs at 30°, 60°, 330° and 300° couch angles respectively, was generated in ECLIPSE v.11 using a Rando-Alderson anthropomorphic head phantom CT study. This plan was a reproduction of a clinical plan generated for a stage-IV melanoma patient diagnosed with 19 intracranial lesions. The phantom was loaded with axially mounted (between phantom slabs) Gafchromic EBT3 film and TLDs strategically positioned within various target volumes. Film and TLDS were calibrated according to established protocols. Target prescription doses were 16 Gy (3cc≤, 3 lesions), 18 Gy (∼1–3cc, 10 lesions) and 20 Gy (≤1cc, 6 lesions). Phantom setup was verified through CBCT imaging prior to irradiation. Gafchromic films were scanned in transmission mode and TLDs were read, respectively, ∼24 hrs after irradiation. Results: Dose calibrated Gafchromic film data were compared to the ECLIPSE calculated data using a 3% / 3mm gamma function analysis. Results for the gamma values were 96–99% in agreement with the calculated data and with 84–90% of the film pixels within the 3% dose difference. TLD data showed a dose difference of 0.4–8% while the film data for those same locations yielded a difference of 0.4–4%. It was observed that the highest dose discrepancies correlated with the location of the small volume targets. Conclusion: Overall this study corroborated that a VMAT SRS treatment, employing various treatment table rotations and arcs, to multiple intracranial lesions with multiple dose prescriptions can be delivered accurately with the existing radiotherapy technology.

60 APPLIED LIFE SCIENCES↗

Atomic Composition and Morphology of Thin Films of Resveratrol Deposited on Oxidized Silicon and Polycrystalline Gold Surfaces

The atomic composition of films of a polyphenol antioxidant, namely, resveratrol (RVL), with a thickness of up to 50 nm thermally deposited on an oxidized silicon surface is studied by the method of X-ray photoelectron spectroscopy (XPS). It is found that the surface area of pores in the RVL film is about 15% of the total surface area. The results of studying the stability of the RVL films when their surface is treated with Ar{sup +} ions of 3 keV under the electric current of 1 μA passing through the sample for 30 s are given. The treatment gives rise to an increase in the area of pores to 30–40%, while the ratio of the concentration of C atoms to the concentration of O atoms in the RVL film both before and after the treatment of the surface with ions does not correspond to the chemical formula of RVL molecules. Using the method of atomic force microscopy (AFM) in contact mode with a scanning area size of about 10 × 10 μm, RVL coatings deposited on the oxidized silicon and polycrystalline Au surfaces are studied. It is found that the RVL films produce grainy and porous coatings on the substrate surfaces. The typical size of grains in the sample surface plane is 150–300 nm, and the characteristic elevation reaches 30 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗