Experimental Study of Counterflow Cooling Using a Test Loop to Simulate the Thermal Characteristics of a HTS Cable System

The counterflow cooling configuration is a compact, efficient, and relatively low cost thermal management approach for long-length HTS cable systems. In the counter-flow cooling configuration the coolant flow, typically liquid nitrogen, is initially supplied through the center of the cable turning around at the far end of the cable and returning through the annular space between the cable and the inner cryostat wall, using a single cryostat. The temperature distributions along the cable and the nitrogen flow streams are extremely difficult to measure in an operating HTS cable because of the issues associated with installing thermometers on high voltage components. A 5-meter long test loop has been built that simulates a counter-flow cooled, HTS cable using a heated metal tube to simulate the cable. The test loop contains calibrated thermometers to measure the temperature distribution along the tube and the return liquid nitrogen stream. Measured temperature distributions in the return flow stream and along the tube wall for varying flow rates and heating conditions to simulate a HTS cable are presented and discussed.

Demko, Jonathan A↗

Spatially assisted down-track median filter for GPR image post-processing

A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

47 OTHER INSTRUMENTATION↗

Real-time system for imaging and object detection with a multistatic GPR array

A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

47 OTHER INSTRUMENTATION↗

A simulation-based study on different control strategies for variable speed pump in distributed ground source heat pump systems

Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional control strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Addressing Multifamily Piping Losses with Solar Hot Water, Davis, California

Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Plasma Interaction with Electron-Emitting Surfaces

Electron emission from surfaces occurs in many plasma systems. Several types including secondary, thermionic and photon-induced emissions are intense under certain conditions. Understanding the effects of emission on the sheaths that govern plasma-surface interaction is important. This dissertation predicts some emitting sheath phenomena that were not reported in past studies. For example, most previous theoretical models assumed that an emitting sheath potential is always negative and that ions always accelerate into the wall. We show when the emission is intense that the sheath potential can become positive, fundamentally changing how the plasma and wall interact. In this inverse sheath state, ions are repelled, suggesting for instance that (a) no presheath exists in the plasma interior, (b) emitting walls could be used in applications to stop sputtering. Another topic considered is the transit of emitted electrons across the plasma to other surfaces, which is possible in low collisionality plasma systems. When transit occurs, the flux balance is a complex global problem where the sheaths at opposite surfaces are coupled through their exchange of emitted electrons. We also show that secondary emission can trigger a variety of sheath instability phenomena that change the state of the plasma-wall system or cause oscillations preventing steady state. Lastly, we analyze a mechanism where emitted electrons return to the same surface and knock out secondaries, which return and knock out more secondaries, etc., feedback amplifying the emission intensity. The four phenomena will be analyzed theoretically and verified with particle-in-cell simulations: (a) inverse sheath, (b) sheath coupling via transiting electrons, (c) sheath instabilities, (d) returning electron amplification. Consequences of these processes on the sheath potentials, wall heating, loss rate of charge, and cross field transport (near-wall conductivity) are discussed throughout. Possible implications are suggested for fusion machines, plasma propulsion engines, probes, dusty plasmas, RF discharges, and surfaces in space.

Fusion↗

Method for Determining the Sensitivity of a Physical Security System.

Modern systems, such as physical security systems, are often designed to involve complex interactions of technological and human elements. Evaluation of the performance of these systems often overlooks the human element. A method is proposed here to expand the concept of sensitivity—as denoted by d’—from signal detection theory (Green & Swets 1966; Macmillan & Creelman 2005), which came out of the field of psychophysics, to cover not only human threat detection but also other human functions plus the performance of technical systems in a physical security system, thereby including humans in the overall evaluation of system performance. New in this method is the idea that probabilities of hits (accurate identification of threats) and false alarms (saying “threat” when there is not one), which are used to calculate d’ of the system, can be applied to technologies and, furthermore, to different functions in the system beyond simple yes-no threat detection. At the most succinct level, the method returns a single number that represents the effectiveness of a physical security system; specifically, the balance between the handling of actual threats and the distraction of false alarms. The method can be automated, and the constituent parts revealed, such that given an interaction graph that indicates the functional associations of system elements and the individual probabilities of hits and false alarms for those elements, it will return the d’ of the entire system as well as d’ values for individual parts. The method can also return a measure of the response bias* of the system. One finding of this work is that the d’ for a physical security system can be relatively poor in spite of having excellent d’s for each of its individual functional elements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Materials for Advanced Ultra-Supercritical (AUSC) Steam Turbines – AUSC Component Demonstration

The work by the United States Department of Energy (U.S. DOE)/Ohio Coal Development Office (OCDO) Advanced Ultra-Supercritical (AUSC) Steam Boiler and Turbine Materials Consortia from 2001 through September 2015 was primarily focused on lab scale and pilot scale materials testing. The field testing included air-cooled probes and steam-cooled “loops” that were installed into existing utility boilers to gain exposure of these materials to realistic conditions of high temperature and corrosion due to the constituents in the coal ash. Successful research and development resulted in identification of metallic alloy materials and fabrication processes suited for power generation applications with metal temperatures up to approximately 1472°F (800°C). These materials or alloys have shown, in extensive laboratory tests and shop fabrication studies, to have excellent applicability for high-efficiency low CO2 transformational power generation technologies. However, as valuable as these material field tests have been for obtaining information, their scale is significantly below that required to minimize the risk associated with a power company building a multi-billion-dollar AUSC power plant. To decrease the identified risk barriers to full-scale implementation of these advanced materials, the U.S. DOE/OCDO AUSC Steam Boiler and Turbine Materials Consortia identified the key areas of the technology that need to be tested at a larger scale. Based upon the recommendations and outcome of a Consortia-sponsored workshop with the U.S.’s leading utilities, a Component Test (ComTest) Program for AUSC was proposed. The AUSC ComTest program would define materials performance requirements, plan for overall advanced system integration, design critical component tests, fabricate components for testing from advanced materials, and carry out the tests. A Pre-FEED evaluation of the test facility including the evaluation of three potential sites has been completed and previously reported. This report describes the Front-End Engineering Design (FEED), Detailed Engineering and the Environmental Assessment of the ComTest project. A significant amount of work was accomplished during Phase 1 to identity the components, as well as the component size, that would be manufactured from advanced alloys such as INCONEL 740H or HAYNES 282 alloys. Pathways to supply these components for ComTest have been identified as well as any further development that would be required. Every project of this nature has challenges and this project was no exception. The greatest challenge has been the project cost. Largely due to the infrastructure and balance of plant equipment upgrades required for Youngstown Thermal, the estimated project cost for the “base case” project was greater than originally budgeted. The project team spent a significant amount of time exploring opportunities for reducing the project cost. These options included: • Youngstown Thermal was exploring building a Combined Heat and Power (CHP) unit at their facility. The Youngstown Thermal staff, supported by Thermal Engineering Group, worked with the project team to determine whether it was economically desirable to supply ComTest with steam and other utilities, which would be supplied by the CHP project. • The project team also evaluated opportunities to optimize the project scope to reduce cost, such as reducing project scope by eliminating the Superheater Outlet Header test. • Southern Company had offered two sites as possible host locations for ComTest. Both sites had infrastructure in place such as steam from an existing unit, natural gas, cooling water and ample electrical power that would be required to be added at the Youngstown Thermal site. Utilizing this existing infrastructure could reduce the project cost. An additional project challenge was the departure of Babcock and Wilcox from the project in September 2016. This project setback was overcome by GE Power’s willingness to assume the design of the ComTest superheater. Since the project could not proceed without the superheater, this was a very positive project development. The merger of the GE Power and Alstom Power steam turbine divisions created synergies leading to the conclusion that instead of building a small-scale turbine, a more practical and useful endeavor would be to validate the manufacturing technology and supplier readiness for fabricating and machining full scale steam turbine components. Consequently, in March 2017, GE Power decided that a steam turbine test would not be necessary as part of the ComTest demonstration. Removing the operational testing of the steam turbine from ComTest further reduced the total project cost. Additionally, there was an opportunity to move ComTest from Youngstown Thermal to one of the Southern Company sites and operate ComTest at supercritical steam conditions and test the steam turbine main stop/control valve at a temperature and pressure that would be representative of the conditions of a high pressure steam turbine inlet valve. The steam could also possibly be returned to the host boiler so there would be no economic penalty of using this steam for ComTest. Relocating the project could further reduce the project cost due to the infrastructure already in place, including high pressure natural gas and cooling water, and the potential for heat integration, allowing a reduction of operating costs. Due to these potential cost reductions, it was decided to move the project away from Youngstown Thermal in March 2017. As integrating ComTest at the Southern Company site was explored, an issue was raised regarding the integration of the ComTest cycle with the plant steam cycle. Steam would be supplied to ComTest at nominally ~3865 psia and 775°F. The steam would be heated with natural gas to 1400°F for the valve test and then cooled to 1000°F so that the steam would be returned to the host boiler at the same conditions as their high pressure steam turbine inlet. However, there were concerns raised that the addition of the energy (natural gas) to the steam could trigger a New Source Review on the unit. Southern Company did not want ComTest to cause this review, so condensing all of the steam exiting ComTest and returning it to the host steam cycle as condensate was explored to insure there would be no implication that ComTest was adding energy to the host plant’s steam cycle. Ultimately, Southern Company decided that they wanted to “decouple” ComTest from the operating unit, making ComTest self-supporting, similar to the Youngstown Thermal “base case.” Without the steam turbine, the project team reached a consensus that operating the ComTest Superheater and steam turbine valves at the typical pressure of a package boiler (~1000 psig) would not generate enough useful technical information to justify the cost of the test. Therefore, it was decided in the December 2017 project quarterly meeting to cancel the operational phase of ComTest. Throughout the engineering phase of ComTest, manufacturing and supply chain challenges were identified. When GE Power recommended dropping the steam turbine test from ComTest, they identified many important manufacturing issues that should be evaluated and demonstrated. Other challenges had been raised by the GE Power group designing the superheater as well as those engineering components such as pressure relief and steam turbine bypass valves. In the December 2017 meeting, the project team decided that it was more beneficial to the AUSC technology to pursue these manufacturing and supply chain issues as Phase 2 of the ComTest project. This report is organized in the following manner: • Section 2 discusses the ComTest project background and organization. • Section 3 discussed project management. • Section 4 discusses the design of the ComTest AUSC components – the Superheater, steam turbine and Superheater Outlet Header. • Section 5 discusses the implementation of ComTest at Youngstown Thermal and the Southern Company site. • Section 6 discusses the development of the AUSC Supply Chain • Section 7 discusses the recommended plan for Phase 2 of ComTest

01 COAL, LIGNITE, AND PEAT↗

Internally-cooled compressor diaphragm

An internally-cooled diaphragm for an internally-cooled compressor is provided. The internally-cooled diaphragm may include an annular body configured to cool a process fluid flowing through a fluid pathway of the internally-cooled compressor. The annular body may define a return channel of the fluid pathway, and a cooling pathway in thermal communication with the fluid pathway. The return channel may be configured to at least partially diffuse and de-swirl the process fluid flowing therethrough, and the cooling pathway may be configured to receive a coolant to absorb heat from the process fluid flowing through the return channel.

42 ENGINEERING↗

Instantaneous ultra-wideband sensing using frequency-domain channelization

A radar system wherein a radar return is channelized by frequency into a plurality of channels, and each of the channels is sampled by a respective analog-to-digital converter that has a sampling rate less than the Nyquist rate of the radar return. The digitally sampled channel signals are Fourier transformed into the frequency domain, where each of the frequency-domain channel signals is matched-filtered according to a respective partial matched filter. The channel signals are then transformed back to the time domain, whereupon they are added together to generate the impulse response of the radar system responsive to the radar return.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Irrigation system

A gravity irrigation system includes a distribution piping having apertures to distribute water to a field, and a valve located upstream of the distribution piping. The valve limits a pressure of the water being delivered to the distribution piping. The system also includes a sump to receive the water at a lowest elevation of the field, a depth sensor disposed within the sump, and a return pump disposed at least partially within the sump to move the water to an elevated portion of the field. The system also includes a motor to drive the return pump, and a power source coupled to a variable frequency drive that powers the motor and controls a motor speed proportionately to an indication of the depth sensor. The system also includes a transfer piping to bring the water from the return pump to a check valve and to the distribution piping.

Henry, Christopher G.↗

A Novel Fiber-Bragg-Grating-Based Unique Identifier for Use in Tags and Seals

Tags and seals are important tools used in safeguards regimes for the control of nuclear materials. Vital to a successful tag or seal is the ability to securely, uniquely, and positively distinguish it from others of the same kind. This allows one to validate that items entered into an inspection regime to which the tag or seal is affixed are as claimed. We are developing a new type of unique identifier (UID) for such applications that is based on fiber-Bragg grating (FBG) technology. The index of refraction of the core glass of a fiber optic can be locally and permanently altered if sensitized fibers are exposed to intense ultraviolet light. This can be used to create index modulations with a regular periodicity comparable to the wavelengths of light with which the fiber is used. If broadband illumination is sent down the fiber, any light that is in resonance with the modulations will be reflected back to the input end of the fiber where it can be detected. The shape of the returned spectrum can be set by the modulation pattern written into the fiber’s core. We take advantage of these properties to create a compact UID that contains several FBGs potted into a monolithic body. By connecting the UID to an optical interrogator, the complex spectral return can be uniquely identified with a short measurement, providing a robust identification. As a device based on narrowband spectral returns, FBGs are inherently radiation tolerant, making them ideal for use with nuclear materials. Further, they can be read out remotely via a long fiber optic or locally via brief connection to a portable optical interrogator. Because the spectral signature of FBGs is sensitive to external mechanical perturbations, we are exploring the ability to reversibly alter the signature obtained from the UID by applying controlled mechanical forces with a simple device. Such a “key” will allow different stakeholders to obtain their own unique signature from the device, providing a new level of surety to safeguards inspections.

Ziock, Klaus-Peter↗

The German product quality control of the compacted metallic nuclear waste - 15311

The treatment and safe disposal of spent nuclear fuel is a key challenge of nuclear energy utilization and has to be accomplished regardless the future nuclear of electricity production or phase-out policies. Until June 2005 approx. 6662 tons of spent fuel from German nuclear power plants was sent to the La Hague (France) and Sellafield (UK) plants for reprocessing. An equivalent amount of nuclear waste compounds has contractually to be returned to Germany, which is currently in progress. The returnable waste streams comprise mainly highly-active vitrified waste containing a major part of fission products and actinides, and intermediate-active super-compacted metallic waste containing reprocessed fuel element's structural materials and some technological waste from the reprocessing process itself. Shearing and dissolution of spent fuel leaves scraps of fuel metal cladding, the end-pieces and spacers which are contaminated, activated and irradiating from their life in a reactor core. In fact, this metallic intermediate level radioactive waste makes up a bit more than half of the total volume of the reprocessed waste. At La Hague the metallic waste is super-compacted. Several, typically eight, compacted discs are stacked in a stainless steel container, named CSD-C as for 'Colis Standard de Dechets Compactes'. 4104 containers of such CSD-Cs in 152 transport/storages casks have to be returned to Germany. Each one of them has to be checked and quality certified for its conformity with German national product specifications and acceptance criteria by independent national product quality control inspectors (PKS). The residue package documentation has to be complete and the characterization methods have to be comprehensive. Due to the heterogeneity of metallic waste the characterization and control of its properties is very complex. The nuclear characterization is performed by means of non-destructive measurements, where only a few key nuclides are measured directly. In fact, the proper calculation of the whole nuclear inventory relies on numerous supplementary simulations. The measurement and calculation methodology is scrutinized by PKS in detail and key points are benchmarked with our own simulations for the sake of an independent nuclear inventory declaration check. With respect to the vast amount of documentation and parameters, which have to be checked and verified, PKS had to optimize their checking procedures. For this purpose dedicated proof tools have been developed that shall be applied for selected indicative cross-checks of the relevant parameters. This contribution is dedicated to the procedure of quality control by PKS and examples of actually performed computational verifications of declared nuclear inventory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dry Storage Cask Shake Table Experiments - 15733

Recent seismic events have underlined the risks nuclear dry storage casks (DSCs) are exposed. Dominion Virginia Power's North Ann during Virginia 5.8 earthquake, August 2011: - 25 of 27 DSCs moved on their concrete pad; - DSCs shifted from 1.0 to 4 1/2 inches; - Metal components were not damaged; - No radiation was released. The main goals of this study is to evaluate the long-term seismic performance of DSCs using experimental tests. Through use of Scaled DSC Specimens on the UNR six Degree-of-Freedom (DOF) Shaking Table. Scaled model specimen shall satisfy the following: - Model aspect ratio shall cover the range in the available commercial DSCs; - Scaled 1/2.5 specimens shall be presentative for the actual prototype (specially under vertical excitation); - Designed specimen shall sustain handling, sliding and impact during testing. Selected evaluation basis earthquakes: - Near Field Earthquake (M6.0 at 2 km); - Far Field Earthquake (M8.0 at 20 km). The level of spectral acceleration using NUREG 6728 seismic hazard curves. Developed for the following return periods: - 1,000-year return period; - 30,000-year return period. Design: - Design handling system for overpack and MPC; - Check stresses on the outer cylindrical shell of the overpack in case of using anchorage system for the DSCs; - Check resulted stresses due to impact of the scaled specimen on the supporting concrete pad; - Check safety of shell thicknesses; - Design of connections between different parts; - Design of the concrete pads to resist impact during the test. Future Plans: - Evaluate the long-term seismic performance of the existing dry storage casks in U.S. and develop guidelines for re-licensing operating periods of DSCs. - Provide a performance based design guidelines for DSCs to maintain its safety against earthquakes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating the Performance and Economics of Transpired Solar Collectors for Commercial Applications: Preprint

Using transpired solar collectors to preheat ventilation air has recently become recognized as an economic alternative for integrating renewable energy into commercial buildings in heating climates. The collectors have relatively low installed costs and operate on simple principles. Theory and performance testing have shown that solar collection efficiency can exceed 70% of incident solar. However, implementation and current absorber designs have adversely affected the efficiency and associated economics from this initial analysis. The National Renewable Energy Laboratory has actively studied this technology and monitored performance at several installations. A calibrated model that uses typical meteorological weather data to determine absorber plate efficiency resulted from this work. With this model, an economic analysis across heating climates was done to show the effects of collector size, tilt, azimuth, and absorptivity. The analysis relates the internal rate of return of a system based on the cost of the installed absorber area. In general, colder and higher latitude climates return a higher rate of return because the heating season extends into months with good solar resource.

14 SOLAR ENERGY↗

System interfaces control document for the Tokamak exhaust processing system PBS 3.2.1

The Tokamak Exhaust Processing System (TEP) removes tritium from highly tritiated gas streams and returns it back to the fuel system. The largest feed streams originate from the torus, but others arrive from systems throughout the tritium plant. Tritium in the form of free hydrogen (i.e., DT, HT) is separated by Pd-Ag permeators or by cryoadsorption and directed to the Isotope Separation System (ISS). Tritium present in impurities (such as CD{sub 2}T{sub 2} and DTO) is chemically converted to free hydrogen, separated by Pd-Ag membranes, and then sent to ISS. All waste streams are processed by the Detritiation System (DS) prior to venting to the atmosphere. The stream received from Helium Glow Discharge Cleaning (GDC) is returned to GDC after processing. TEP is also designed to accommodate a Tritium Plant (TP) standby mode of operation whereby gases received from fuelling are processed by TEP and returned to SDS. This S-ICD describes all process interfaces for TEP and contains tables to control their progressive definition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An evaporite sequence from ancient brine recorded in Bennu samples

Evaporation or freezing of water-rich fluids with dilute concentrations of dissolved salts can produce brines, as observed in closed basins on Earth and detected by remote sensing on icy bodies in the outer Solar System. The mineralogical evolution of these brines is well understood in regard to terrestrial environments, but poorly constrained for extraterrestrial systems owing to a lack of direct sampling. Here we report the occurrence of salt minerals in samples of the asteroid (101955) Bennu returned by the OSIRIS-REx mission. These include sodium-bearing phosphates and sodium-rich carbonates, sulfates, chlorides and fluorides formed during evaporation of a late-stage brine that existed early in the history of Bennu’s parent body. Discovery of diverse salts would not be possible without mission sample return and careful curation and storage, because these decompose with prolonged exposure to Earth’s atmosphere. Similar brines probably still occur in the interior of icy bodies Ceres and Enceladus, as indicated by spectra or measurement of sodium carbonate on the surface or in plumes.

58 GEOSCIENCES↗

The Determination of the Spatial Distribution of Indigenous Lipid Biomarkers in an Immature Jurassic Sediment Using Time-of-Flight–Secondary Ion Mass Spectrometry

The ability to detect and map lipids, including potential lipid biomarkers, within a sedimentary matrix using mass spectrometry (MS) imaging may be critical to determine whether potential lipids detected in samples returned from Mars are indigenous to Mars or are contaminants. Here, we use gas chromatography–mass spectrometry (GC-MS) and time-of-flight–secondary ion mass spectrometry (ToF-SIMS) datasets collected from an organic-rich, thermally immature Jurassic geologic sample to constrain MS imaging analysis of indigenous lipid biomarkers in geologic samples. GC-MS data show that the extractable fractions are dominated by C 27 –C 30 steranes and sterenes as well as isorenieratene derivatives. ToF-SIMS spectra from organic matter-rich laminae contain a strong, spatially restricted signal for ions m/z 370.3, m/z 372.3, and m/z 386.3, which we assign to C 27 sterenes, cholestane (C 27 ), and 4- or 24-methyl steranes (C 28 ), respectively, as well as characteristic fragment ions of isorenieratene derivatives, including m/z 133.1, m/z 171.1, and m/z 237.1. We observed individual steroid spatial heterogeneity at the scale of 10's to 100's of microns. The fine-scale heterogeneity observed implies that indigenous lipid biomarkers concentrated within specific regions may be detectable via ToF-SIMS in samples with even low amounts of organic carbon, including in samples returned from Mars.