Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “random testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Revision of laser-induced damage threshold evaluation from damage probability data

In this study, the applicability of commonly used Damage Frequency Method (DFM) is addressed in the context of Laser-Induced Damage Threshold (LIDT) testing with pulsed lasers. A simplified computer model representing the statistical interaction between laser irradiation and randomly distributed damage precursors is applied for Monte Carlo experiments. The reproducibility of LIDT predicted from DFM is examined under both idealized and realistic laser irradiation conditions by performing numerical 1-on-1 tests. A widely accepted linear fitting resulted in systematic errors when estimating LIDT and its error bars. For the same purpose, a Bayesian approach was proposed. A novel concept of parametric regression based on varying kernel and maximum likelihood fitting technique is introduced and studied. Such approach exhibited clear advantages over conventional linear fitting and led to more reproducible LIDT evaluation. Furthermore, LIDT error bars are obtained as a natural outcome of parametric fitting which exhibit realistic values. The proposed technique has been validated on two conventionally polished fused silica samples (355 nm, 5.7 ns).

36 MATERIALS SCIENCE↗

(U) A General-Purpose Code for Correlated Sampling Using Batch Statistics with MCNP6 for Fixed-Source Problems

Correlated sampling can be used to reduce the uncertainty of a difference of tallies by taking advantage of the negative covariance term in the sandwich formula. Booth first showed how correlated sampling can be applied with batch statistics using MCNP’s tally fluctuation chart (TFC) to reduce the uncertainty of a difference of tallies in fixed-source problems. Booth presented a problem in which a 1273% uncertainty in a difference was reduced to 8% by accounting for correlations. Researchers He and Su recently studied correlated sampling using the TFC in MCNP version 5. They determined that the code did not print enough digits in the TFC tally means for accurate batch statistics in some cases. After modifying the source code, they concluded that “correlated sampling can yield a standard deviation of about one magnitude smaller than that predicted by the direct, un-correlated simulation when the changes in system response are small (say about 1%), which is equivalent to saving in CPU time by a factor of 100. Such saving [sic] becomes less significant as the change in system response becomes larger.” He and Su provided the formulas needed to apply batch statistics to compute the correlated uncertainty of a difference of tallies. In this report, we follow up on their work by providing the formulas needed to apply batch statistics to compute the correlated uncertainty of a ratio of tallies and of a difference of two tallies divided by a third tally. We extend these formulas to differences and ratios of ratios. These formulas are applied to reduce the uncertainty associated with calculating a relative sensitivity. He and Su did not investigate the accuracy of their correlated sampling uncertainty estimates. We use their test problems and evaluate the accuracy of the uncertainty estimates by comparing with results obtained from random sampling, and, in simple cases, with theoretical values of the “exact” uncertainties. We find that the uncertainties obtained from batch statistics are accurate as long as at least 100 batches are used. We present a new computer code, COSUBS (COrrelated Sampling Using Batch Statistics), that reads MCNP6 TFCs and applies correlated sampling using batch statistics for the tally combinations that the user specifies. COSUBS is a very general tool that compares all TFCs for a base case and one or two perturbed cases. It computes uncertainties for ratios if given only a base case. This report is organized as follows. The equations to apply batch statistics to the difference of random tallies are reviewed in Sec. II. Section III presents the equations for applying batch statistics to a ratio of random tallies; this is useful for computing relative sensitivities using a one-sided finite difference and the relative sensitivity using the differential operator method. Section IV presents the equations for applying batch statistics to a difference of two random tallies divided by a third; this is useful for computing a relative sensitivities using a central difference. Section V presents the equations for applying batch statistics to a difference of two ratios with four random tallies. Section VI presents the equations for applying batch statistics to a one-sided finite difference estimate of the relative sensitivity of a ratio (this uses four random tallies). Section VII presents the equations for applying batch statistics to a central difference estimate of the relative sensitivity of a ratio (this uses six random tallies). Section VIII presents the equations for applying batch statistics to a sum of random tallies. Section IX discusses how to apply batch statistics using MCNP6. Section X presents COSUBS, describing its command-line options and logic. Sections XI through XVI present numerical results for various test problems. Section XVII is a summary and conclusions. Appendix A derives the theoretical Monte Carlo tally variance given certain assumptions; these variances are used to verify the batch statistics for some of the problems. Appendix B lists the MCNP6 input for the unperturbed example problem. Appendix C presents modifications made to MCNP6.3 to support this work.

97 MATHEMATICS AND COMPUTING↗

Can the angular scale of cosmic homogeneity be used as a cosmological test?

Abstract In standard cosmology, the cosmic homogeneity scale is the transition scale above which the patterns arising from non-uniformities – such as groups and clusters of galaxies, voids, and filaments – become indistinguishable from a random distribution of sources. Recently, different groups have investigated the feasibility of using such a scale as a cosmological test and arrived at different conclusions. In this paper, we complement and extend these studies by exploring the evolution of the spatial ( $$R_{\textrm{H}}$$ R H ) and angular ( $$\theta _{\textrm{H}}$$ θ H ) homogeneity scales with redshift, assuming a spatially flat, $$\varLambda $$ Λ -Cold Dark Matter universe and linear cosmological perturbation theory. We confirm previous results concerning the non-monotonicity of $$R_{\textrm{H}}$$ R H with the matter density parameter $$\varOmega _{\textrm{m0}}$$ Ω m0 but also show that it exhibits a monotonical behavior with the Hubble constant $$H_{0}$$ H 0 within a large redshift interval. More importantly, we find that, for $$z \gtrsim 0.6$$ z ≳ 0.6 , $$\theta _{\textrm{H}}$$ θ H presents a monotonical behavior with $$\varOmega _{\textrm{m0}}$$ Ω m0 , as well as for $$H_0$$ H 0 the entire redshift interval analyzed. We find also that the angular homogeneity scale is sensitive to $$H_{0}$$ H 0 , especially at higher redshifts. Using the currently available $$\theta _{\textrm{H}}$$ θ H measurements, we illustrate the constraints on the $$\varOmega _{\textrm{m0}}$$ Ω m0 – $$H_{0}$$ H 0 plane through a MCMC analysis and show the feasibility of using the angular homogeneity scale as a new, model-independent way to constrain cosmological parameters.

Physics↗

Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the computation time decrease with the number of points and that no effects were observed on the dosimetric indices when varying the number of sampling points and the number of iterations, they were respectively fixed to 2500 and to 100. The computation time to obtain ten complete treatments plans ranging from 9 to 18 catheters, with the corresponding dosimetric indices, was 90 s. However, 93% of the computation time is used by a research version of IPSA. For the breast, on average, the Radiation Therapy Oncology Group recommendations would be satisfied down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of V100, dose homogeneity index, and D90.Conclusions: The authors have devised a simple, fast and efficient method to optimize the number and position of catheters in interstitial HDR brachytherapy. The method was shown to be robust for both prostate and breast HDR brachytherapy. More importantly, the computation time of the algorithm is acceptable for clinical use. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real-time guidance and planning in HDR brachytherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computer-aided detection of breast masses: Four-view strategy for screening mammography

Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding views of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.

60 APPLIED LIFE SCIENCES↗

Perpendicular diffusion of energetic particles in noisy reduced magnetohydrodynamic turbulence

A model for noisy reduced magnetohydrodynamic turbulence was recently proposed. This model was already used to study the random walk of magnetic field lines. In the current article we use the same model to investigate the diffusion of energetic particles across the mean magnetic field. To compute the perpendicular diffusion coefficient, two analytical theories are used, namely, the Non-Linear Guiding Center theory and the Unified Non-Linear Transport (UNLT) theory. It is shown that the two theories provide different results for the perpendicular diffusion coefficient. We also perform test-particle simulations for the aforementioned turbulence model. We show that only the UNLT theory describes perpendicular transport accurately, confirming that this is a powerful tool in diffusion theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep ugrizY imaging and DEEP2/3 spectroscopy: a photometric redshift testbed for LSST and public release of data from the DEEP3 Galaxy Redshift Survey

ABSTRACT We present catalogues of calibrated photometry and spectroscopic redshifts in the Extended Groth Strip, intended for studies of photometric redshifts (photo-z’s). The data includes ugriz photometry from Canada–France–Hawaii Telescope Legacy Survey (CFHTLS) and Y-band photometry from the Subaru Suprime camera, as well as spectroscopic redshifts from the DEEP2, DEEP3, and 3D-HST surveys. These catalogues incorporate corrections to produce effectively matched-aperture photometry across all bands, based upon object size information available in the catalogue and Moffat profile point spread function fits. We test this catalogue with a simple machine learning-based photometric redshift algorithm based upon Random Forest regression, and find that the corrected aperture photometry leads to significant improvement in photo-z accuracy compared to the original SExtractor catalogues from CFHTLS and Subaru. The deep ugrizY photometry and spectroscopic redshifts are well suited for empirical tests of photometric redshift algorithms for LSST. The resulting catalogues are publicly available at http://d-scholarship.pitt.edu/36064/. We include a basic summary of the strategy of the DEEP3 Galaxy Redshift Survey to accompany the recent public release of DEEP3 data.

79 ASTRONOMY AND ASTROPHYSICS↗

Holographic Kolmogorov-Sinai entropy and the quantum Lyapunov spectrum

In classical chaotic systems the entropy, averaged over initial phase space distributions, follows a universal behavior. While approaching thermal equilibrium it passes through a stage where it grows linearly, while the growth rate, the Kolmogorov-Sinai entropy (rate), is given by the sum over all positive Lyapunov exponents. A natural question is whether a similar relation is valid for quantum systems. We argue that the Maldacena-Shenker-Stanford bound on quantum Lyapunov exponents implies that the upper bound on the growth rate of the entropy, averaged over states in Hilbert space that evolve towards a thermal state with temperature T, should be given by πT times the thermal state’s von Neumann entropy. Strongly coupled, large N theories with black hole duals should saturate the bound. To test this we study a large number of isotropization processes of random, spatially homogeneous, far from equilibrium initial states in large N, $\mathcal{N}$ = 4 Super Yang Mills theory at strong coupling and compute the ensemble averaged growth rate of the dual black hole’s apparent horizon area. We find both an analogous behavior as in classical chaotic systems and numerical evidence that the conjectured bound on averaged entropy growth is saturated granted that the Lyapunov exponents are degenerate and given by λ i = ±2πT. This fits to the behavior of classical systems with plus/minus symmetric Lyapunov spectra, a symmetry which implies the validity of Liouville’s theorem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Template-directed preparation of two-layer porous NiO film via hydrothermal synthesis for lithium ion batteries

Graphical abstract: A two-layer porous NiO film is prepared via hydrothermal synthesis method based on monolayer polystyrene sphere template and shows noticeable Li battery performance with good cycle life and high capacity. Highlights: ► Two-layer porous NiO film is prepared via monolayer polystyrene spheres template. ► NiO film with high capacity as anode material for lithium ion batteries. ► Two-layer porous structure is favorable for fast lithium ion and electron transfer. -- Abstract: A two-layer porous NiO film is prepared by hydrothermal synthesis method through self-assembled monolayer polystyrene spheres template. The substructure of the NiO film is composed of ordered close-packed hollow-sphere array and the superstructure is made up of randomly NiO nanoflakes. The electrochemical properties are measured by galvanostatic charge/discharge tests and cyclic voltammetric analysis (CV). As anode material for lithium ion batteries, the two-layer porous NiO film exhibits high initial coulombic efficiency of 75%, high reversible capacity and rather good cycling performance. The discharge capacity of the two-layer porous NiO film is 501 mAh g{sup −1} at 0.5 C after 50 cycles. The two-layer porous architecture is responsible for the enhancement of electrochemical properties.

36 MATERIALS SCIENCE↗

MODELING OF THE NON-GAUSSIAN PDFs OF FIELD VARIATIONS AND INTERMITTENCY IN THE TURBULENT SOLAR WIND

The probability distribution functions (PDFs) of magnetic field variations display strong scale-dependent non-Gaussianity in the turbulent solar wind. This is a typical signature of intermittent turbulence. Physical modeling of the turbulent field variations based on the characteristics of the observed turbulence, including the variability of its power level, produces, free of parameter adjustment and over a broad range of inertial scales, accurate fits of the non-Gaussian PDFs. The effects of phase randomization and time resolution of the Fourier power spectra are further tested to determine which of the phase correlation or the spectral variability is responsible for the strong non-Gaussianity of the observed PDFs of field variations. The periods of enhanced power level are found to be responsible for the non-Gaussian tails of the PDFs.

79 ASTRONOMY AND ASTROPHYSICS↗

The 3D Lyman- α forest power spectrum from eBOSS DR16

We measure the three-dimensional power spectrum (P3D) of the transmitted flux in the Lyman-α (Ly α) forest using the complete extended Baryon Oscillation Spectroscopic Survey data release 16 (eBOSS DR16). This sample consists of ~205 000 quasar spectra in the redshift range 2 ≤ z ≤ 4 at an effective redshift z = 2.334. We propose a pair-count spectral estimator in configuration space, weighting each pair by exp( i k ∙ r), for wave vector k and pixel pair separation r, effectively measuring the anisotropic power spectrum without the need for fast Fourier transforms. This accounts for the window matrix in a tractable way, avoiding artefacts found in Fourier-transform based power spectrum estimators due to the sparse sampling transverse to the line of sight of Ly α skewers. We extensively test our pipeline on two sets of mocks: (i) idealized Gaussian random fields with a sparse sampling of Ly α skewers, and (ii) log-normal LyaCoLoRe mocks including realistic noise levels, the eBOSS survey geometry and contaminants. On eBOSS DR16 data, the Kaiser formula with a non-linear correction term obtained from hydrodynamic simulations yields a good fit to the power spectrum data in the range $(0.02 ≤ k ≤ 0.35)$ h Mpc -1 at the 1–2σ level with a covariance matrix derived from LyaCoLoRe mocks. We demonstrate a promising new approach for full-shape cosmological analyses of Ly α forest data from cosmological surveys such as eBOSS, the currently observing Dark Energy Spectroscopic Instrument and future surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of energy window for {sup 90}Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch

Purpose: In yttrium-90 ({sup 90}Y) microsphere brachytherapy (radioembolization) of unresectable liver cancer, posttherapy {sup 90}Y bremsstrahlung single photon emission computed tomography (SPECT) has been used to document the distribution of microspheres in the patient and to help predict potential side effects. The energy window used during projection acquisition can have a significant effect on image quality. Thus, using an optimal energy window is desirable. However, there has been great variability in the choice of energy window due to the continuous and broad energy distribution of {sup 90}Y bremsstrahlung photons. The area under the receiver operating characteristic curve (AUC) for the ideal observer (IO) is a widely used figure of merit (FOM) for optimizing the imaging system for detection tasks. The IO implicitly assumes a perfect model of the image formation process. However, for {sup 90}Y bremsstrahlung SPECT there can be substantial model-mismatch (i.e., difference between the actual image formation process and the model of it assumed in reconstruction), and the amount of the model-mismatch depends on the energy window. It is thus important to account for the degradation of the observer performance due to model-mismatch in the optimization of the energy window. The purpose of this paper is to optimize the energy window for {sup 90}Y bremsstrahlung SPECT for a detection task while taking into account the effects of the model-mismatch. Methods: An observer, termed the ideal observer with model-mismatch (IO-MM), has been proposed previously to account for the effects of the model-mismatch on IO performance. In this work, the AUC for the IO-MM was used as the FOM for the optimization. To provide a clinically realistic object model and imaging simulation, the authors used a background-known-statistically and signal-known-statistically task. The background was modeled as multiple compartments in the liver with activity parameters independently following a Gaussian distribution; the signal was modeled as a tumor with a Gaussian-distributed activity parameter located randomly with equal probability at one of three positions. The IO test statistics (i.e., likelihood ratios) were estimated using Markov-chain Monte Carlo methods. The authors realistically modeled human anatomy using a digital phantom code, and realistically simulated {sup 90}Y bremsstrahlung SPECT imaging with a clinical SPECT system and typical imaging parameters using a previously validated Monte Carlo bremsstrahlung simulation method. Model-mismatch was included by modeling image formation process in the calculation of IO test statistics using an analytic modeling method previously developed for quantitative {sup 90}Y bremsstrahlung SPECT. To demonstrate the effects of the model-mismatch on the detection task, the authors optimized the energy window both with and without model-mismatch included in the IO. Results: For all the energy windows, the AUC values for the IO-MM were smaller than that for the IO. The optimal windows for the IO-MM and the IO were 80-180 and 60-400 keV, respectively. Conclusions: The authors have demonstrated the degradation of the ideal performance due to model-mismatch and optimized the energy window for {sup 90}Y bremsstrahlung SPECT for detection tasks by accounting for the effects of the model-mismatch. The obtained optimal window was much narrower when taking into account the model-mismatch and similar to that obtained previously for estimation tasks.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-202-11: Radiobiological Modeling of Tumor Response During Radiotherapy Based On Pre-Treatment Dynamic PET Imaging Data

Purpose: To evaluate the ability of a multiscale radiobiological model of tumor response to predict mid-treatment hypoxia images, based on pretreatment imaging of perfusion and hypoxia with [18-F]FMISO dynamic PET and glucose metabolism with [18-F]FDG PET. Methods: A mechanistic tumor control probability (TCP) radiobiological model describing the interplay between tumor cell proliferation and hypoxia (Jeong et al., PMB 2013) was extended to account for intra-tumor nutrient heterogeneity, dynamic cell migration due to nutrient gradients, and stromal cells. This extended model was tested on 10 head and neck cancer patients treated with chemoradiotherapy, randomly drawn from a larger MSKCC protocol involving baseline and mid-therapy dynamic PET scans. For each voxel, initial fractions of proliferative and hypoxic tumor cells were obtained by finding an approximate solution to a system of linear equations relating cell fractions to voxel-level FDG uptake, perfusion (FMISO K{sub 1}) and hypoxia (FMISO k{sub 3}). The TCP model then predicted their evolution over time up until the mid treatment scan. Finally, the linear model was reapplied to predict each lesion’s median hypoxia level (k{sub 3}[med,sim]) which in turn was compared to the FMISO k{sub 3}[med] measured at mid-therapy. Results: The average k3[med] of the tumors in pre-treatment scans was 0.0035 min{sup −1}, with an inter-tumor standard deviation of σ[pre]=0.0034 min{sup −1}. The initial simulated k{sub 3}[med,sim] of each tumor agreed with the corresponding measurements within 0.1σ[pre]. In 7 out of 10 lesions, the mid-treatment k{sub 3}[med,sim] prediction agreed with the data within 0.3σ[pre]. The remaining cases corresponded to the most extreme relative changes in k{sub 3}[med]. Conclusion: This work presents a method to personalize the prediction of a TCP model using pre-treatment kinetic imaging data, and validates the modeling of radiotherapy response by predicting changes in median hypoxia values during treatment. Variations from predicted response may be a useful biomarker, which should be further explored. Partially supported by NIH grant #1 R01 CA157770-01A1 and a grant from Varian Corporation.

60 APPLIED LIFE SCIENCES↗

A scalable variational method for estimating the latent infection-rate field of an outbreak

In this paper, we explore whether the infection-rate of a disease can serve as a robust monitoring variable in epidemiological surveillance algorithms. The infection-rate is dependent on population mixing patterns that do not vary erratically day-to-day; in contrast, daily case-counts used in contemporary surveillance algorithms are corrupted by reporting errors. The technical challenge lies in estimating the latent infection-rate from case-counts. Here we devise a Bayesian method to estimate the infection-rate across multiple adjoining areal units, and then use it, via an anomaly detector, to discern a change in epidemiological dynamics. We extend an existing model for estimating the infection-rate in an areal unit by incorporating a Markov random field model, so that we may estimate infection-rates across multiple areal units, while preserving spatial correlations observed in the epidemiological dynamics. To carry out the high-dimensional Bayesian inverse problem, we develop an implementation of mean-field variational inference specific to the infection model and integrate it with the random field model to incorporate correlations across counties. The method is tested on estimating the COVID-19 infection-rates across all 33 counties in New Mexico using data from the summer of 2020, and then employing them to detect the arrival of the Fall 2020 COVID-19 wave. We perform the detection using a temporal algorithm that is applied county-by-county. We also show how the infection-rate field can be used to cluster counties with similar epidemiological dynamics.

60 APPLIED LIFE SCIENCES↗

Computer Experiments for Function Approximations

This research project falls in the domain of response surface methodology, which seeks cost-effective ways to accurately fit an approximate function to experimental data. Modeling and computer simulation are essential tools in modern science and engineering. A computer simulation can be viewed as a function that receives input from a given parameter space and produces an output. Running the simulation repeatedly amounts to an equivalent number of function evaluations, and for complex models, such function evaluations can be very time-consuming. It is then of paramount importance to intelligently choose a relatively small set of sample points in the parameter space at which to evaluate the given function, and then use this information to construct a surrogate function that is close to the original function and takes little time to evaluate. This study was divided into two parts. The first part consisted of comparing four sampling methods and two function approximation methods in terms of efficiency and accuracy for simple test functions. The sampling methods used were Monte Carlo, Quasi-Random LP{sub {tau}}, Maximin Latin Hypercubes, and Orthogonal-Array-Based Latin Hypercubes. The function approximation methods utilized were Multivariate Adaptive Regression Splines (MARS) and Support Vector Machines (SVM). The second part of the study concerned adaptive sampling methods with a focus on creating useful sets of sample points specifically for monotonic functions, functions with a single minimum and functions with a bounded first derivative.

99 GENERAL AND MISCELLANEOUS↗

Vehicle Position Detection Based on Machine Learning Algorithms in Dynamic Wireless Charging

Dynamic wireless charging (DWC) has emerged as a viable approach to mitigate range anxiety by ensuring continuous and uninterrupted charging for electric vehicles in motion. DWC systems rely on the length of the transmitter, which can be categorized into long-track transmitters and segmented coil arrays. The segmented coil array, favored for its heightened efficiency and reduced electromagnetic interference, stands out as the preferred option. However, in such DWC systems, the need arises to detect the vehicle’s position, specifically to activate the transmitter coils aligned with the receiver pad and de-energize uncoupled transmitter coils. This paper introduces various machine learning algorithms for precise vehicle position determination, accommodating diverse ground clearances of electric vehicles and various speeds. Through testing eight different machine learning algorithms and comparing the results, the random forest algorithm emerged as superior, displaying the lowest error in predicting the actual position.

47 OTHER INSTRUMENTATION↗

SU-E-J-119: What Effect Have the Volume Defined in the Alignment Clipbox for Cervical Cancer Using Automatic Registration Methods for Cone- Beam CT Verification?

Purpose: To investigate the impact of different clipbox volumes with automated registration techniques using commercially available software with on board volumetric imaging(OBI) for treatment verification in cervical cancer patients. Methods: Fifty cervical cancer patients received daily CBCT scans(on-board imaging v1.5 system, Varian Medical Systems) during the first treatment week and weekly thereafter were included this analysis. A total of 450 CBCT scans were registered to the planning CTscan using pelvic clipbox(clipbox-Pelvic) and around PTV clip box(clipbox- PTV). The translations(anterior-posterior, left-right, superior-inferior) and the rotations(yaw, pitch and roll) errors for each matches were recorded. The setup errors and the systematic and random errors for both of the clip-boxes were calculated. Paired Samples t test was used to analysis the differences between clipbox-Pelvic and clipbox-PTV. Results: . The SD of systematic error(σ) was 1.0mm, 2.0mm,3.2mm and 1.9mm,2.3mm, 3.0mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. The average random error(Σ)was 1.7mm, 2.0mm,4.2mm and 1.7mm,3.4mm, 4.4mm in the AP, LR and SI directions for clipbox-Pelvic and clipbox-PTV, respectively. But, only the SI direction was acquired significantly differences between two image registration volumes(p=0.002,p=0.01 for mean and SD). For rotations, the yaw mean/SD and the pitch SD were acquired significantly differences between clipbox-Pelvic and clipbox-PTV. Conclusion: The defined volume for Image registration is important for cervical cancer when 3D/3D match was used. The alignment clipbox can effect the setup errors obtained. Further analysis is need to determine the optimal defined volume to use the image registration in cervical cancer. Conflict of interest: none.

60 APPLIED LIFE SCIENCES↗