Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupoles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

DESIGN AND CONSTRUCTION OF A 15 T, 120 MM BORE IR QUADRUPOLE MAGNET FOR LARP

Pushing accelerator magnets beyond 10 T holds a promise of future upgrades to machines like the Large Hadron Collider (LHC) at CERN. Nb{sub 3}Sn conductor is at the present time the only practical superconductor capable of generating fields beyond 10 T. In support of the LHC Phase-II upgrade, the US LHC Accelerator Research Program (LARP) is developing a large bore (120 mm) IR quadrupole (HQ) capable of reaching 15 T at its conductor peak field and a peak gradient of 219 T/m at 1.9 K. While exploring the magnet performance limits in terms of gradient, forces and stresses the 1 m long two-layer coil will demonstrate additional features such as alignment and accelerator field quality. In this paper we summarize the design and report on the magnet construction progress.

43 PARTICLE ACCELERATORS↗

Steady State Heat Deposits Modeling in the Nb3Sn Quadrupole Magnets for the Upgrade of the LHC Inner Triplet

In hadron colliders such as the LHC, the energy deposited in the superconductors by the particles lost from the beams or coming from the collision debris may provoke quenches detrimental to the accelerator operation. In previous papers, a Network Model has been used to study the thermodynamic behavior of magnet coils and to calculate the quench levels in the LHC magnets for expected beam loss profiles. This model was subsequently used for thermal analysis and design optimization of Nb{sub 3}Sn quadrupole magnets, which LARP (US LHC Accelerator Research Program) is developing for possible use in the LHC luminosity upgrade. For these new magnets, the heat transport efficiency from the coil to the helium bath needs to be determined and optimized. In this paper the study of helium cooling channels and the heat evacuation scheme are presented and discussed.

43 PARTICLE ACCELERATORS↗

Alternative Mechanical Structure for LARP Nb3Sn Quadrupoles

An alternative structure for the 120 mm Nb{sub 3}Sn quadrupole magnet presently under development for use in the upgrade for LHC at CERN is presented. The goals of this structure are to build on the existing technology developed in LARP with the LQ and HQ series magnets and to further optimize the features required for operation in the accelerator. These features include mechanical alignment needed for field quality and provisions for cold mass cooling with 1.9 K helium in a helium pressure vessel. The structure will also optimize coil azimuthal and axial pre-load for high gradient operation, and will incorporate features intended to improve manufacturability, thereby improving reliability and reducing cost.

43 PARTICLE ACCELERATORS↗

Quadrupole magnet for a rapid cycling synchrotron

Rapid Cycling Synchrotrons (RCS) feature interleaved warm and cold dipole magnets; the field of the warm magnets is used to modulate the average bending field depending on the particle energy. It has been shown that RCS can be an attractive option for fast acceleration of particles, for example, muons, which decay quickly. In previous studies it was demonstrated that in principle warm dipole magnets can be designed which can provide the required ramp rates, which are equivalent to frequencies of about 1 kHz. To reduce the losses it is beneficial to employ two separate materials for the yoke; it was also shown that by employing an optimized excitation coil geometry the eddy current losses are acceptable. In this paper we show that the same principles can be applied to quadrupole magnets targeting 30 T/m with a repetition rate of 1kHz and good field quality.

43 PARTICLE ACCELERATORS↗

Analytic Solution of the Envelope Equations for an Undepressed Matched Beam in a Quadrupole Doublet Channel

In 1958, Courant and Snyder analyzed the problem of alternating-gradient beam transport and treated a model without focusing gaps or space charge. Recently we revisited their work and found the exact solution for matched-beam envelopes in a linear quadrupole lattice [O.A. Anderson and L.L. LoDestro, Phys. Rev. ST Accel. Beams, 2009]. We extend that work here to include the effect of asymmetric drift spaces. We derive the solution and show exact envelopes for the first two solution bands and the peak envelope excursions as a function of the phase advance {sigma} up to 360{sup o}. In the second stable band, decreased occupancy requires higher focusing strength. For symmetric gaps, this accentuates the remarkable compression effect predicted for the FD (gapless) model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analytic Solution of the Envelope Equations for an Undepressed Matched Beam in a FODO Quadrupole Channel

In 1958, Courant and Snyder analyzed the problem of alternating-gradient beam transport and treated a model without focusing gaps or space charge. Recently we revisited their work and found the exact solution for matchedbeam envelopes in a linear quadrupole lattice [O.A. Anderson and L.L. LoDestro, Phys. Rev. ST Accel. Beams, 2009]. We extend that work here to include the effect of asymmetric drift spaces. We derive the solution and show exact envelopes for the first two solution bands and the peak envelope excursions as a function of the phase advancesigma up to 360o. In the second stable band, decreased occupancy requires higher focus field-strength and accentuates the remarkable compression effect predicted for the FD (gapless) model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fission Quadrupole Mass Parameters in HF+BCS and HFB Methods

The self-consistent Hartree-Fock+BCS and Hartree-Fock-Bogoliubov methods are compared at large nuclear deformations. The calculations are carried out for the fission pathway and quadrupole mass parameter of ^{252}Fm.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CesrTA Retarding Field Analyzer Measurements in Drifts, Dipoles, Quadrupoles and Wigglers

Over the course of the CesrTA program, the Cornell Electron Storage Ring (CESR) has been instrumented with several retarding field analyzers (RFAs), which measure the local density and energy distribution of the electron cloud. These RFAs have been installed in drifts, dipoles, quadrupoles, and wigglers; and data have been taken in a variety of beam conditions and bunch configurations. This paper will provide an overview of these results, and give a preliminary evaluation of the efficacy of cloud mitigation techniques implemented in the instrumented vacuum chambers.

43 PARTICLE ACCELERATORS↗

Effects of processing on the efficacy and metabolites of Cistanche tubulosa using ultra‐performance liquid chromatography coupled with quadrupole time‐of‐flight mass spectrometry

Abstract Cistanche tubulosa (CT), a well‐known traditional Chinese medicine, has always been processed with rice wine for the treatment of kidney‐yang deficiency syndrome (KYDS) since time immemorial. To explore the effect of processing on the efficacy and metabolites of CT in vivo , a comprehensive method using ultra‐performance liquid chromatography coupled with quadrupole time‐of‐flight mass spectrometry was established for the analysis of the altered endogenous metabolites in response to the intervention of the raw and processed CT in KYDS model and the metabolites of the absorbed compounds in rats after gastric perfusion. It was shown that CT could improve KYDS, and the effect of the processed product was more significant. A total of 47 differential metabolites were identified in urine. Pathway analysis proved that purine metabolism; alanine, aspartate, and glutamate metabolism; and citrate cycle were the main pathways. Furthermore, 53 prototypes and 48 metabolites have been detected in rats. This was the first systematic research focus on the metabolites of raw and processed CT in vivo , which could provide a scientific basis for explaining the increasing efficiency of the processed CT. Moreover, it provides a valuable strategy for analyzing the chemical components and metabolites of other TCM prescriptions.

Lei, Huibo↗

Identification of Blue Discoloration in PBX 9404 using Ultrahigh Pressure Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry

PBX 9404, composed of 94 wt% HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazoctane), 3 wt% NC (nitrocellulose), 2.9 wt% CEF (tris(beta-chloroethyl) phosphate) and 0.1 wt% DPA (diphenylamine), has often been observed with a slight to entire blue discoloration of the manufactured prills. This blue discoloration has been observed since the formulation development of PBX 9404 in the late 1950s. In order to determine the source of the blue discoloration in PBX 9404, ultraviolet/visible (UV/Vis) absorbance of PBX 9404 and two potential candidates for the discoloration, p-nitrosodiphenylamine (p-NDPA) and N-nitrosodiphenylamine (N-NDPA) were evaluated. An absorbance band at 590 nm in PBX 9404 sample was attributed to the blue discoloration while p-NDPA and N-NPDA had different absorbance bands. Using the knowledge gained from the UV/Vis analysis, a semi-targeted approach using ultrahigh pressure liquid chromatography coupled to UV/Vis detector and quadrupole time of flight mass spectrometry (UHPLC-UV/Vis-QTOF) was implemented. Investigating the UHPLC-UV/Vis-QTOF chromatograms at a wavelength of 590 nm, a single compound was tentatively identified as being the source of the blue discoloration. Targeted tandem mass spectrometry (MS/MS) on the compound and subsequent analysis indicated that 4,4 -{[4-(Phenylimino)-2,5-cyclohexadien-1-ylidene]methylene}bis(N-phenylaniline), also known as Spirit Blue Base, was the source of the blue discoloration, which was confirmed using a standard. Here, a theory on the formation of Spirit Blue Base in PBX 9404 involving DPA, nitric acid (HNO 3 ) / nitrogen oxide(s) NO x , and formaldehyde is proposed.

36 MATERIALS SCIENCE↗

Determining P, S, Br, and I content in uranium by triple quadrupole inductively coupled plasma mass spectrometry

The trace impurities of a uranium ore concentrate (UOC) can be examined to determine mine source, methods of production, and quality. This study presents a method to determine the concentration of halides and main group elements, specifically P, S, Br and I, utilizing triple quadrupole inductively coupled plasma–mass spectrometry. These analytes were measured in a uranium matrix to simulate a UOC sample. The concentrations determined with this method showed agreement with known values. Solutions with and without uranium were compared. A UOC certified reference material, CUP-2, was analyzed to further demonstrate the effectiveness of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen measurement during steam oxidation using coupled thermogravimetric analysis and quadrupole mass spectrometry

An analytical technique is presented with the goal of measuring reaction kinetics during steam oxidation reactions for three cases in which obtaining kinetics information often requires a prohibitive amount of time and cost. The technique presented relies on coupling thermogravimetric analysis (TGA) with a quantitative hydrogen measurement technique using quadrupole mass spectrometry (QMS). The first case considered is in differentiating between the kinetics of steam oxidation reactions and those for simultaneously reacting gaseous impurities such as nitrogen or oxygen. The second case allows one to independently measure the kinetics of oxide and hydride formation for systems in which both of these reactions are known to take place during steam oxidation. The third case deals with measuring the kinetics of formation for competing volatile and non-volatile oxides during certain steam oxidation reactions. In order to meet the requirements of the coupled technique, a methodology is presented which attempts to provide quantitative measurement of hydrogen generation using QMS in the presence of an interfering fragmentation species, namely water vapor. This is achieved such that all calibrations and corrections are performed during the TGA baseline and steam oxidation programs, making system operation virtually identical to standard TGA. Benchmarking results showed a relative error in hydrogen measurement of 5.7–8.4% following the application of a correction factor. Lastly, suggestions are made for possible improvements to the presented technique so that it may be better applied to the three cases presented.

36 MATERIALS SCIENCE↗

Effects of the quadrupole wakefields in a passive streaker

A novel method based on transverse wakefields has been recently proposed to characterize the temporal profile of a relativistic electron bunch. The electron bunch is streaked by the interaction with the transverse wakefield excited when the electrons travel off-axis in a device called the passive streaker. Furthermore, for the large transverse off-axis offsets required to effectively streak the electron bunch, higher order modes can be excited. The time-dependent quadrupole wakefield of the dielectric-lined structure can cause a significant enlargement of the transverse profile at the screen. Consequently, the measurement resolution is decreased also at the bunch tail. We report on how the temporal profile can be effectively reconstructed also including the defocusing effect for a given transverse beam distribution at the passive streaker.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and fabrication of a four-rod radio frequency quadrupole with a variable aperture

Radiofrequency quadrupole (RFQ) linear accelerators with variable aperture cell parameters offer an effective means of accelerating high-intensity ion beams exceeding 100 mA and have been implemented in various RFQ designs. However, in a four-rod RFQ, the use of dielectric perturbation methods to measure the voltage distribution behind the rod electrodes is not applicable when implementing variable aperture geometries, because changes in the rod shape influence the electric field at the location of the perturbation element. Therefore, it was necessary to design the rod profile for each cell such that the electric field distribution behind the rods remains unaffected by changes in the aperture. In this study, we present a method to adjust the voltage distribution by modifying the geometry of the rod electrodes according to each cell's aperture parameters. This design approach enables the integration of variable aperture cells into a four-rod RFQ linac, significantly enhancing the achievable beam current. To ensure uniform capacitance and maintain a constant rod-electrode voltage despite variations in the average aperture radius, we developed a systematic method for shaping the rod electrodes. This method was refined using two-dimensional (2D) and three-dimensional (3D) electromagnetic field simulations to optimize the electrode cross-sectional profiles. The fabricated rod electrodes were then installed in a four-rod RFQ, and the electric field distribution was measured using the perturbation method and tuned by adjusting the base plates. As a result, the measured variation of ±1.1 % confirms that this design methodology can produce a sufficiently uniform voltage distribution for high-current beam acceleration. These results demonstrate the practical feasibility of a variable-aperture four-rod RFQ linac.

43 PARTICLE ACCELERATORS↗

Ultrasensitive Sample Quantitation via Selected Reaction Monitoring Using CITP/CZE-ESI-Triple Quadrupole MS

We demonstrate the direct coupling of transient capillary isotachophoresis/ capillary zone electrophoresis (CITP/CZE) with a high sensitivity triple quadrupole mass spectrometer operating in selected reaction monitoring (SRM) mode for sample quantitation. The capability of CITP/CZE for in situ sample enrichment and separation has been shown to significantly improve the analytical figures of merit. A linear dynamic range spanning more than 4 orders of magnitude was observed. An average signal-to-noise ratio (S/N) of 49.6 was observed for 50 attomoles of targeted peptide in the presence of a complex and much more abundant bovine serum albumin (BSA) digest products. A correlation of variation (CV) less than 10 % for peak area was measured from triplicate sample analyses at 50 pM peptide concentration, showing good reproducibility of this online CITP/CZE-SRM mass spectrometry (MS) platform, and with limit of quantitation (LOQ) demonstrated to be well below 50 pM.

Environmental Molecular Sciences Laboratory↗

Orthogonal Injection Ion Funnel Interface Providing Enhanced Performance for Selected Reaction Monitoring-Triple Quadrupole Mass Spectrometry

The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher pressure regions (e.g. ion source interfaces) of mass spectrometers, and thus providing increased sensitivity. An “off-axis” ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to charge ratios. In this study a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadruple mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at 9-10 Torr pressure. Several critical factors for the HPIF were characterized, including the effects of RF amplitude, DC gradient and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. Lastly, the sensitivity enhancement in liquid chromatography selected reaction monitoring (SRM) analyses of low abundance peptides spiked into a highly complex mixture was also compared with that obtained using a both commercial s-lens interface and a in-line dual ion funnel interface.

47 OTHER INSTRUMENTATION↗

Enhancing Sensitivity in Targeted Single-Cell Proteomics by Coupling a Dual Ion Funnel Interface with Triple Quadrupole Mass Spectrometer

Single-cell proteomics (SCP) has emerged as a powerful approach for understanding cellular heterogeneity and biological processes at unprecedented resolution. However, the extremely limited protein content of individual cells (femtogram to picogram levels) pushes current mass spectrometry instrumentation to its sensitivity limits, creating a critical analytical bottleneck. While selected reaction monitoring (SRM) using triple quadrupole (QqQ) instruments 1 offers advantages in sensitivity and reproducibility for targeted proteomics quantification, SRM still struggles with sensitivity for quantification of moderate- or low-abundance proteins from single-cell sample amounts. Here, we report the development and systematic evaluation of a dual ion funnel interface designed to address the sensitivity limitation by significantly enhancing ion transmission efficiency in commercial QqQ mass spectrometers. The dual ion funnel interface, composed of a curved S-funnel followed by a conventional ion funnel, improves ion transmission efficiency while reducing chemical noise through selective ion focusing. The performance of the dual ion funnel interface was systematically compared to standard interface on a TSQ Vantage platform across samples with different levels of complexity. The dual funnel interface demonstrated to provide up to 25-fold improvement in sensitivity across a wide range of protein concentrations in different biological matrices (low complex mouse macrophage and high complex human cells). Critically, enhanced sensitivity was accompanied by increased analytical reproducibility with lower coefficient of variations. Most importantly, the dual funnel interface enabled reliable quantification of low-abundance proteins that were barely detectable or not detected by the standard interface, extending analysis to single-cell equivalent amounts while maintaining excellent reproducibility. These results demonstrate that the dual funnel interface addresses the critical bottleneck in quantitative targeted proteomics, providing a technological foundation for ultrasensitive targeted SCP that requires both high sensitivity and robust quantitative performance.

Min, Sehong↗