Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel Modular Residential CCHP for Space Conditioning and Water Heating

This presentation will first describe the design of a novel modular residential cold-climate heat pump for both space conditioning and water heating that can be coupled with thermal energy storage (TES) to maximize system efficiency and load flexibility. Among some of the novel operating modes of the proposed design include: 1) simultaneous outdoor coil defrost while still providing space heating or water heating; 2) simultaneous water heating and space cooling 3) using the TES as the heat source during cold climate operation to improve efficiency and 4) compressorless charging of the TES module during days with high temperature swings between night and day. Then, initial simulation results will be presented describing system performance in key operating modes in climate region 5.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature Dependent Spin Dynamics in La 0.67 Sr 0.33 MnO 3 /Pt Bilayers

Complex ferromagnetic oxides such as La 0.67 Sr 0.33 MnO 3 (LSMO) offer pathways for creating energy‐efficient spintronic devices with new functionalities. LSMO exhibits high‐temperature ferromagnetism, half metallicity, sharp resonance linewidth, low damping, and a large anisotropic magnetoresistance response. Combined with Pt, a proven material with high spin‐charge conversion efficiency, LSMO can be used to create robust nano‐oscillators for neuromorphic computing. Ferromagnetic resonance (FMR) and device‐level spin‐pumping FMR measurements are performed to investigate the magnetization dynamics and spin transport in NdGaO 3 (110)/LSMO(15 nm)/Pt(0 and 5 nm) thin films ranging from 300 K to 90 K and compare the device performance with Py(7 nm)/Pt(5 nm) sample. The spin current pumped into Pt is quantified to determine the temperature‐dependent influence of interfacial interactions. The generated spin current in the micro‐device is maximum at 170 K for the optimally grown LSMO/Pt films. Additionally, this bilayer system exhibits low magnetic Gilbert damping (0.002), small linewidth (12 Oe), and a large spin Hall angle (≈3.2%) at 170 K. Ex situ deposited LSMO/Pt bilayers demonstrate excellent dynamic response, exhibiting fourfold enhancement in signal output, eightfold reduction in damping, and a threefold reduction in linewidth as compared to the Pt/Py system. Such robust device‐level performance can pave way for energy‐efficient spintronic‐based devices.

complex perovskite thin films↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Integrated Heat Pump

This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.

Shen, Bo↗

Exploring the Limits of Cooling for Extreme Heat Flux Applications: Data Centers and Power Electronic

We developed an Extreme Heat Flux Micro-cooler (EHFµ-C) capable of removing heat flux of ~1 kW/cm 2 with a small temperature rise ~10°C. This represents greater than 10× reduction in thermal resistance compared to the state-of-the-art single-phase cooling technologies (~0.5 cm 2 -°C/W) that greatly increases the efficiency, resulting in improved performance and reliability for microprocessors and power electronics. The EHFµ-Cooler utilizes liquid wicking (no pump) and thin-film evaporation in a 30 µm thick wick porous microstructure such as copper inverse opal (CIO), silicon and AlN pin fins along with a 3D manifold (copper wiremesh and silicon) with liquid routing and vapor extraction channels achieving an unprecedented vapor quality ~ >0.9. The proposed EHFµ-Cooler significantly reduces device temperature, resulting in 25-50% improvement in reliability and device performance. Based on very conservative estimates, the total energy saving for data centers due to improved performance can be 6 billion kWh/year (>$300M). Better cooling, leading to more efficient, higher performance and more reliable power electronics, would save the nation 3 Quad of primary energy in 2030. Just for automotive application, a 10% increase in fuel efficiency for SiC-based power electronics equates to >20 million gallons of fuel savings annually. The proposed EHFµ-Cooler technology ensures the United States maintains its technological lead in high-performance computing and high-power electronics, while at the same time improving the energy efficiency, and as a result reducing energy-related emissions such as greenhouse gases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Informing electrification strategies of residential neighborhoods with urban building energy modeling

Electrifying end uses is a key strategy to reducing GHG emissions in buildings. However, it may increase peak electricity demand that triggers the need to upgrade the existing power distribution system, leading to delays in electrification and needs of significant investment. There is also concern that building electrification may cause an increase of energy costs, leading to further energy burden for low-income communities. This study uses the urban scale building modeling tool CityBES to assess the electrification impacts of more than 43,000 residential buildings in a neighborhood of Portland, Oregon, USA. Energy efficiency upgrades were investigated on their potential to mitigate the increase of peak electricity demand and energy burden. Simulation results from the calibrated EnergyPlus models show that electrification with heat pumps for space heating and cooling as well as for domestic water heating can reduce CO2e emissions by 38%, but increase peak electricity demand by about 9% from the baseline building stock. Combining electrification measures and energy efficiency upgrades can reduce CO2e emissions by 48% while reducing peak electricity demand by 6% and saving the median household energy costs by 28%. City and utility decision makers should consider integrating energy efficiency upgrades with electrification measures as an effective residential building electrification strategy, which significantly reduces carbon emissions, caps or even decreases peak demand while reducing energy burden of residents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Community Resilience through Low-Temperature Geothermal Reservoir Thermal Energy Storage

Submitted data include simulations related to underground thermal battery (UTB) simulations described in Modeling and efficiency study of large scale underground thermal battery deployment, presented at GRC, October 2021. The UTB is comprised of a tank of water, a helical heat exchanger in the center of tank and connected to a water source heat pump, and a phase change material (PCM). Compared to a conventional VBGHE, the UTB is designed to be installed at a much shallower depth, therefore, with a cheaper cost. In addition, the GSHP efficiency is improved due to natural convection of water and additional load capacity provided by PCM. The goal of this study is to explore factors that may affect the efficiency of large-scale UTB deployment. The simulations found in this submission relate to the report on UTB deployment.

15 GEOTHERMAL ENERGY↗

Separation of Artifacts from Spin–Torque Ferromagnetic Resonance Measurements of Spin–Orbit Torque for the Low–Symmetry Van der Waals Semi–Metal ZrTe 3

Spin-orbit torques generated by exfoliated layers of the low-symmetry semi-metal ZrTe 3 are measured using the spin-torque ferromagnetic resonance (ST-FMR) technique. When the ZrTe 3 has a thickness greater than about 10 nm, artifacts due to spin pumping and/or resonant heating can cause the standard ST-FMR analysis to overestimate the true magnitude of the torque efficiency by as much as a factor of 30, and to indicate incorrectly that the spin-orbit torque depends strongly on the ZrTe 3 layer thickness. Artifact-free measurements can still be achieved over a substantial thickness range by the method developed recently to detect ST-FMR signals in the Hall geometry as well as the longitudinal geometry. ZrTe 3 /Permalloy samples generate a conventional in-plane anti-damping spin torque efficiency ξ$^{FL}_{∥}$ = 0.014 ± 0.004, and an unconventional in-plane field-like torque efficiency |ξ$^{FL}_{∥}$| = 0.003 ± 0.001. As a result, the out-of-plane anti-damping torque is negligible. It is suggested that artifacts similarly interfere with the standard ST-FMR analysis for other van der Waals samples thicker than about 10 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Integrating Analytical Solutions and U-Net Model for Predicting Groundwater Contaminant Plumes in Pump-and-Treat Systems

Pump-and-treat (P&T) is a common technique for groundwater remediation involving the extraction and treatment of contaminated water above ground. Optimizing the design and operation of the P&T well network is essential for maximizing the system’s effectiveness and efficiency. However, this optimization often necessitates many model evaluations, leading to computationally demanding tasks. This study introduces a novel approach that integrates analytical solutions for groundwater dynamics with the U-Net (Ronneberger et al., 2015) deep learning framework to predict groundwater contaminant plume migration under dynamic pumping conditions. By incorporating the Thiem equation (Thiem, 1906) into the input preprocessing, the U-Net model transforms sparse well data into a continuous spatial field that captures the hydraulic impacts of pumping activities. This integration enables the model to leverage both deep learning capabilities and classical physics-based groundwater theories, enhancing prediction accuracy and computational efficiency. These advancements can facilitate rapid, large-scale evaluations of P&T optimization simulations, allowing for timely and effective decision-making in well placement and system management. We demonstrate the model's robust performance across both simplified transient 2D models and a more complex 3D heterogeneous site model at the 200 West P&T facility at the Hanford Site. The U-Net-based model offers substantial computational advantages, reducing simulation times significantly compared to full physics-based models and providing a powerful tool for rapid site evaluation and P&T system optimization, such as evaluating alternative P&T well network designs. Our findings highlight the potential of advanced machine learning models to significantly enhance the efficiency and sustainability of groundwater remediation efforts, offering a novel application of U-Net architecture in environmental science.

Pump-and-treat↗

Optical parametric amplification of spectrally incoherent pulses

The optical parametric amplification of spectrally incoherent signals is analyzed and simulated using a set of normalized equations describing phase-matched three-wave nonlinear mixing. Varying the amplifier’s properties and the seeding conditions reveals different amplification regimes. In particular, the relative temporal walk-off of the signal, idler, and pump has a strong impact on the temporal and spectral properties of the amplified signal. The amplification efficiency for spectrally incoherent signals is not significantly lower than that of a coherent monochromatic signal, provided that the phase-matching bandwidth is sufficient. Here, the results obtained with the normalized set of equations are in good agreement with simulations based on the full description of the crystals’ dispersion for high-gain LBO and BBO preamplifiers and a low-gain DKDP power amplifier.

47 OTHER INSTRUMENTATION↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Moisture-driven CO 2 pump for direct air capture

Direct Air Capture, the chemical separation of carbon dioxide (CO 2 ) from air, is considered a necessary approach to generate negative carbon emissions and in turn limit global warming, though energetic and monetary costs must continue to decline to meet the needed gigaton scale. The promise of energy-efficient and continuous carbon dioxide membrane separation has only recently been investigated with the development of facilitated chemical transport and novel electrochemically driven methods. This work demonstrates the potential for continuous pumping of CO 2 from air using commercial anion exchange membranes driven solely by a water vapor gradient. A reactive transport model that couples ionic transport with moisture sensitive bicarbonate chemistry in charged polymers, also termed moisture swing sorption, was developed alongside experimentally measured equilibrium and transport properties of CO 2 and water vapor in Fumasep FAA-3 to determine the mass transport limits of such a system. The results show that the commercial membrane is kinetically limited by the moisture sensitive chemistry, enabling a CO 2 current of 1.1 μmol/m 2 • s. In diffusion limited materials, a CO 2 pumping flux can reach 11 μmol/m 2 • s in and peak performance is expected with a dry air relative humidity around 50% pumping into a saturated water vapor permeate. In all configurations, water loss becomes the major cost in such a separation and must be managed through optimal polymer design or water recovery mechanisms. The work demonstrates the applicability of a new driving force, the evaporation of water, to meet the energetic demand of CO 2 separation from air.

36 MATERIALS SCIENCE↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Mid-Infrared Nonlinear Frequency Conversion Using Monolithic Barium Titanate on Silicon-on-Insulator

In this work, efficient nonlinear frequency conversion in the mid-infrared (mid-IR) region was demonstrated by a barium titanate (BTO) on a silicon-on-insulator (SOI) substrate. The BTO thin film was epitaxially grown by pulsed-laser deposition (PLD). The tensorial second order optical nonlinearity and the ferroelectric domain property of the BTO were characterized by the polarimetric mid-IR second harmonic generation (SHG) measurements. Azimuthal-dependent polarized SHG was modeled at different combinations of the nonlinear coefficient $d_{ij}$ and the domain fraction factor $ΔD^Y/ΔD^X$. Strong SHG intensity was experimentally observed over a broad spectrum at λ = 3.1 μm - 3.7 μm. A characteristic linear dependence between the SHG signal and the square of the pumping laser intensity was observed. The monolithic integration between the epitaxial BTO and the Si provides a compact platform for efficient on-chip light generation and quantum photonic technologies.

25 ENERGY STORAGE↗

Development and evaluation of a multi-functional heat pump with embedded thermal storage

We developed and tested a novel multi-functional packaged vertical heat pump designed for multi-family buildings, capable of providing space cooling, space heating, water heating, and energy storage integration. The system employs a 3-speed scroll compressor and supports energy-efficient cooling and heating across different ambient conditions, while utilizing both indoor and outdoor air sources for water heating. Key performance metrics include an integrated energy efficiency ratio of 18.0 for cooling, a heating seasonal performance factor of 10.0, and a coefficient of performance (COP) of 2.1 for heating in cold climates down to −15 ˚C. Additionally, the system delivers an annual water heating COP greater than 4.0, with outstanding performance in combined space cooling and water heating modes, achieving a total COP of 8.8 by recovering condenser waste heat. The heat pump also demonstrated thermal energy storage capabilities, integrating with phase change material systems to store heating and cooling energy. Furthermore, this versatile system offers a promising solution for improving energy efficiency and sustainability in multi-family buildings, providing high-performance heating, cooling, and water heating across a range of climates.

COP↗

A Comparison of Power Take-Off Architectures for Wave-Powered Reverse Osmosis Desalination of Seawater with Co-Production of Electricity

Several power take-off (PTO) architectures for wave-powered reverse osmosis (RO) desalination of seawater are introduced and compared based on the annual average freshwater production and the size of the components, which strongly relate to the costs of the system. The set of architectures compared includes a novel series-type PTO architecture not previously considered. These seawater hydraulic PTO architectures are composed of a WEC-driven pump, an RO module, an intake charge pump driven by an electric motor, and a hydraulic motor driving an electric generator for electric power production. This study is performed using an efficient two-way coupled steady-state model for the average performance of the system in a given sea state, including freshwater permeate production, electric power production, and electric power consumption. A multi-objective design problem is formulated for the purposes of this comparative study, with the objectives of maximizing annual freshwater production, minimizing the displacement of the WEC-driven pump, and minimizing the installed RO membrane area. This establishes a framework for comparison in the absence of a mature techno-economic model. The requirement that the system produces enough electric power to meet its consumption is applied as a constraint on the operation of the system. The oscillating wave surge converter Oyster 1 is assumed as the WEC. Weights on performance of the system in a given sea state are based on historical data from Humboldt Bay, CA. This study finds that (1) architectures in a series configuration allow for a reduction in the WEC-driven pump size of 59–92% compared to prior work, (2) varying the displacement of the WEC-driven pump between sea conditions does not provide any significant advantage in performance, and (3) varying the active RO membrane area between sea condition offers improvements between 7% and 41% in each design objective.

Energy & Fuels↗