Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “product development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Producing carbon stripper foils containing boron

Parameters being actively tested by the accelerator community for the purpose of extending carbon stripper foil lifetimes in fast ion beams include methods of deposition, parting agents, mounting techniques, support (fork) materials, and inclusion of alloying elements, particularly boron. Specialized production apparatus is required for either sequential deposition or co-deposition of boron in carbon foils. A dual-use vacuum evaporator for arc evaporation of carbon and electron-beam evaporation of boron and other materials has been built for such development. Production of both carbon and boron foils has begun and improvements are in progress.

36 MATERIALS SCIENCE↗

The role of the research simulator in the systems development of rotorcraft

The potential application of the research simulator to future rotorcraft systems design, development, product improvement evaluations, and safety analysis is examined. Current simulation capabilities for fixed-wing aircraft are reviewed and the requirements of a rotorcraft simulator are defined. The visual system components, vertical motion simulator, cab, and computation system for a research simulator under development are described.

Statler, I. C.↗

Photovoltaics - Where are we going?

The directions that will be followed for solar cell development, production and marketing are projected on the basis of experiences gained during the JPL's Flat-Plate Solar Array project. It is thought that a billion dollar market for Si ribbons can be established by 1990. Thin film technology will yield a product at $2 U.S./W at the end of the 1980s. R&D is growing more focused on central station photovoltaic generators, although the residential market may be the more suitable goal. The intermediate markets, e.g., schools, hospitals and shopping centers may be developed before the central stations.

Callaghan, W. T.↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultra-Efficient Engine Technology Project Integrated Into NASA's Vehicle Systems Program

The Ultra-Efficient Engine Technology (UEET) Project is formulated according to the Office of Aerospace Technology's objectives as outlined in the NASA Strategic Plan. It is directly related to the "protect the environment" objective and will make progress toward the "increase mobility" and "support national security" objectives as well. UEET technologies will impact future civil and military aircraft and will benefit the development of future space transportation propulsion systems. UEET Project success will, therefore, depend on developing revolutionary, but affordable, technology solutions that are inherently safe and reliable and thus can be incorporated in future propulsion system designs. In fiscal year 2003, UEET became part of NASA's Vehicle Systems Program and continues to evolve its programmatic role. The Vehicle Systems Program aims to develop breakthrough technologies and methodologies, push the boundaries of flight through research on advanced vehicle concepts, respond quickly to industry and the Department of Defense on critical safety and other issues, and provide facilities and expert consultation for industry and other Government agencies during product development.

Shaw, Robert J.↗

Numerical Studies of Depressurization-Induced Gas Production from an Interbedded Marine Turbidite Gas Hydrate Reservoir Model

The numerical simulation of thin hydrate-bearing sand layers interbedded with mud layers is investigated. In this model, the lowest hydrate layer occurs at the base of gas hydrate stability and overlies a thinly-interbedded saline aquifer. The predicted gas rates reach 6.25 MMscf/day (~1.77 x 10 5 m 3 /day) after 90 days of continuous depressurization with manageable water production. Development of horizontal dissociating interfaces between hydrate-bearing sand and mud layers is a primary determinant of reservoir performance. A set of simulations has been executed to assess uncertainty in in situ permeability and to determine the impact of the saline aquifer on productivity.

Myshakin, Evgeniy↗

An In Situ , Automated High-Explosives Aging Method Utilizing Two-Dimensional Gas Chromatography–Mass Spectrometry

Understanding chemical changes that occur in high explosives as they age is of great importance to the safe employment and storage of these compounds. Traditional methods of aging high explosives even under accelerated aging conditions are time intensive with durations on the order of months to years. The nature of traditional aging analyses reduces each sample to a snapshot data point often separated widely in time, requiring many assumptions as to how the degradation products develop. Further complicating matters, several analytical techniques are typically employed for each sample analysis in order to ascertain an entire picture of the decomposition pathways. To address these shortcomings with existing methods, a new method of accelerated aging of high explosives utilizing comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry (GC × GC-HRMS) was developed using 2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (CL-20) as a model compound for method development. This in situ automated method reduces the time scale of aging to a matter of hours using the inlet of the GC × GC as the aging vessel. GC × GC in combination with HRMS allowed for the collection of both evolved gases and other decomposition products produced during the entire aging process in real time with HRMS providing far greater certainty in identification of explosives aging products. Additionally, this method allowed for a higher throughput of samples with greatly simplified sample preparation. Chemometric analysis of the GC × GC-HRMS data set via the alteration analysis (ALA) enabled discovery of statistically significant chemical changes providing insight into the variation of decomposition pathways with varying aging temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RFA for Solar/Geothermal Hybrid Thermal Energy Storage Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-16-646

Hyperlight Energy is an innovative concentrated solar power (CSP) company whose business charter is to commercialize a disruptively low-cost, CSP collector system that is ultimately for providing heat for solar thermal/geothermal hybrid power plants, process heat applications (e.g., enhanced oil recovery), and solar thermal power generation. Hyperlight's CSP collector system utilizes a linear Fresnel reflector (LFR) configuration. This LFR configuration consists of mirrors mounted in low-cost, precision plastic extrusions, which are integrated into raft assemblies and floated on low-cost, sealed waterbeds. Hyperlight's CSP collector technology has been developed under private equity investment, government grant and commercial funding. Hyperlight has been awarded a 1.5-million DOE COLLECTS contract with an additional 1.6 million in matched funds from private investment and the California Energy Commission. This DOE project will support the final steps of product development for bulk commercialization and deployment of the Hyperlight CSP collector system. The work will culminate in a final operational deployment at a commercially relevant site. Several such site options are currently under evaluation, including two geothermal sites. Hyperlight identified a very low-cost way to put renewable energy electrons on the grid at peak times, upgrading underutilized geothermal plants with Hyperlight's low cost CSP and thermal energy storage (TES). While Hyperlight's CSP collector work is maturing quickly for commercial pilot launch, an optimal TES system for solar thermal/geothermal hybridization needs to be evaluated and ultimately developed so Hyperlight can develop commercial retrofit projects at a scale of hundreds of megawatts of renewable energy power output at sites across the United States, followed by greenfield projects in a multi-GW sized market.

15 GEOTHERMAL ENERGY↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial transport aircraft composite structures

The role that analysis plays in the development, production, and substantiation of aircraft structures is discussed. The types, elements, and applications of failure that are used and needed; the current application of analysis methods to commercial aircraft advanced composite structures, along with a projection of future needs; and some personal thoughts on analysis development goals and the elements of an approach to analysis development are discussed.

Mccarty, J. E.↗

2018 NISAR Applications Workshop: Agriculture and Soil Moisture

Agricultural lands cover the globe and play an essential role in not only sustaining a growing global population, but can have significant implications on the Earth system through land use change (e.g., deforestation, grazing, etc.). As such, countries around the world have dedicated programs for managing these lands. Accurate and timely information concerning the status of agricultural crops (soil moisture, crop health, crop type, etc.) is essential to those nations’ anthropogenic and ecological health as well as economy. The joint NASA/US Department of Agriculture Agricultural Research Service (USDA-ARS) workshop focused on advancing agriculture and soil moisture applications by using remote sensing data from the NASA-ISRO Synthetic Aperture Radar (NISAR) mission (expected launch 2022). Participants included representatives from the international agriculture community that are key players in facilitating integration of Earth Observations into decision support workflows including US Federal Agencies, nonprofits, and private sector. They included scientists, technicians, and program managers with a responsibility for data acquisition and exploitation such as product development, delivery, and use, as well as capacity building. Discussions were held over two and a half days to convey the broader agriculture and soil moisture community information needs, the mission and procedures for various representative participants and programs involved in the delivery of geospatial products, and the capabilities and status of the NISAR mission. Case studies were presented to demonstrate the current state of practice in the use of SAR remote sensing for applications of direct importance for the agriculture and soil moisture communities. Eleven organizations presented their information requirements in response to a set of questions provided by the NASA team, then the NASA team responded by describing the degree to which NISAR could meet these requirements. Discussion ensued about needed data product specifications to increase utility (e.g., projection, latency, etc.), tools and capacity building.

Stavros, Natasha↗

Protecting Crew and Surface Systems with a Long-Duration Lunar Safe Haven

NASA’s Artemis program will send astronauts to the lunar surface for extended mission durations throughout the 2030s, with a focus on sustainability and extensibility for Mars exploration, as described in NASA’s “Artemis Plan”. However, NASA must place more emphasis on protecting both the crew and the exploration surface systems if they hope to achieve long-duration sustainability on the lunar surface. It is now reasonably achievable with excavation, construction, and autonomy technologies to achieve a significant level of protection that architectures have been unable to achieve to date. The Lunar Safe Haven (LSH) was proposed to protect astronauts, electronics, and other surface exploration systems from the hazards of the lunar environment, including radiation, micrometeoroid strikes, lunar dust, thermal vacuum, etc. During the study, Level Zero Requirements were developed for the LSH, and a decision analysis framework was baselined to evaluate concepts. The LSH Study also performed a comprehensive trade study, during which it identified numerous alternatives for establishing and maintaining a safe haven shelter on the lunar surface. This paper reviews the products developed during the study and presents the final recommendations.

radiation shielding↗

NASA/DOD Aerospace Knowledge Diffusion Research Project. XXIV - A general approach to measuring the value of aerospace information products and services

This paper discusses the various approaches to measuring the value of information, first defining the meanings of information, economics of information, and value. It concludes that no general model of measuring the value of information is possible and that the usual approaches, such as cost/benefit equations, have very limited applications. It also concludes that in specific contexts with given goals for newly developed products and services or newly acquired information, there is a basis for its objective valuation. The axioms and inputs for such a model are described and directions for further verification and analysis are proposed.

Brinberg, Herbert R.↗

NASA/DOD Aerospace Knowledge Diffusion Research Project. Paper 24: A general approach to measuring the value of aerospace information products and services

This paper discusses the various approaches to measuring the value of information, first defining the meanings of information, economics of information, and value. It concludes that no general model of measuring the value of information is possible and that the usual approaches, such as cost/benefit equations, have very limited applications. It also concludes that in specific contexts with given goals for newly developed products and services or newly acquired information there is a basis for its objective valuation. The axioms and inputs for such a model are described and directions for further verification and analysis are proposed.

Brinberg, Herbert R.↗

Ski Boots

In cooperation with Raichle Molitor USA Inc. and the international Raichle organization, Comfort Products developed the Raichle Flexon concept in ski boots. The Flexon concept is an adaptation of the accordion-like corrugations of extravehicular space suit joints, which allows ski boots to flex without significant distortion. The design provides immediate transmission of power and therefore precision skiing. Comfort Products also applied heating element circuitry from Apollo astronaut's clothing to foot-warming devices in their boots in the 1970s.

Source record↗

Misalignment Tolerant Three-phase Wireless Fast Charging System for Electric Vehicles

This project proposes improving the technology level of the three-phase wireless charging technology developed at Oak Ridge National Laboratory (ORNL). Successful commercialization of wireless charging systems require that they meet strict safety standards for electromagnetic field emissions and interoperability with other wireless charging technology. ORNL has previously demonstrated a 50kW three-phase wireless power transfer system with 95% efficiency. This prototype system weighed less than 50% of similar high-power wireless charging system while simultaneously exhibiting better safety characteristics. Due to better material utilization, the reduction in mass is expected to translate into similar cost reduction for the magnetic coupler. Additionally, the smaller footprint of the system can ease vehicle integration difficulties that would be encountered using other technology. Furthermore, the three-phase design can be made to operate with existing single-phase coupler design more easily and without intentional physical misalignment which would otherwise pose safety issues.This project developed ORNL’s WPT technology to satisfy the specifications and requirements for electric vehicle (EV) charging. The result of the project will be a prototype and reference design for a high-power wireless charging system—including magnetics, power electronics, and controls—serving as a baseline for product development.

33 ADVANCED PROPULSION SYSTEMS↗