Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “point absorber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Asteroid orbit evolution due to thermal drag

Thermal drag, a variant of the Yarkovsky effect, may act on small asteroids with sizes from a few meters to a few tens of meters. Yarkovsky thermal drag comes from an asteroid's absorbing sunlight in the visible and reradiating it in the infrared. Since the infrared photons have momentum, by action-reaction, they kick the asteroid when they leave its surface. The reradiation, which is asymmetric in latitude over the asteroid, gives a net force along the asteroid's pole. Due to the asteroid's thermal inertia, averaging this force over one orbital period produces a net drag if the spin axis has a component in the orbital plane. Thermal drag tends to circularize orbits. It can increase or decrease orbital inclinations. An object whose spin axis points in random directions over its lifetime displays little change in orbital inclination. Thermal drag appears to have little to do with the delivery of chondrites from the asteroid belt; the thermal drag timescale (10(exp 8) years for meter-sizzed objects) is long compared with their cosmic ray exposure ages, and aphelia in the asteroid belt are not expected for mature thermal drag orbits. However, Yarkovsky thermal drag may act on the recently discovered near-Earth asteroids, which have radii of 10-30 m. Asteroid 1992 DA, for instance, might have its orbit shrunk by 0.1 AU in 3 x 10(exp 7) years, removing it from an Earth-crossing orbit. The near-Earth asteroids also tend to have small to moderate orbital eccentricities, as expected for highly evolved thermal drag objects. However, the time needed to bring them in from the asteroid belt (about 10(exp 9) years) is long compared with the collisonal and dynamical lifetimes (both about 10(exp 8) years) for Earth-crossing objects, arguing against their emplacement by thermal drag.

Rubincam, David Parry↗

On the Nature of CP Pup

We present new X-ray and optical spectra of the old nova CP Pup (nova Pup 1942) obtained with Chandra and the CTIO 4m telescope. The X-ray spectrum reveals a multi-temperature optically thin plasma reaching a maximum temperature of 36+19 keV 16 absorbed by local complex neutral material. The time resolved optical spectroscopy confirms the presence of the 1.47 hr period, with cycle-to-cycle amplitude changes, as well as of an additional long term modulation which is suggestive either of a longer pe- riod or of non-Keplerian velocities in the emission line regions. These new observational facts add further support to CP Pup as a magnetic cataclysmic variable (mCV). We compare the mCV and the non-mCV scenarios and while we cannot conclude whether CP Pup is a long period system, all observational evidences point at an intermediate polar (IP) type CV.

PUP↗

Three Canted Radiator Panels to Provide Adequate Cooling for Instruments on Slewing Spacecraft in LEO

Certain free-flying spacecraft in low Earth orbit (LEO) or payloads on the International Space Station (ISS) are required to slew to point the telescopes at targets. Instrument detectors and electronics require cooling. Traditionally a planar thermal radiator is used. The temperature of such a radiator varies significantly when the spacecraft slews because its view factors to space vary significantly. Also for payloads on the ISS, solar impingement on the radiator is possible. These thermal adversities could lead to inadequate cooling for the instrument. This paper presents a novel thermal design concept that utilizes three canted radiator panels to mitigate this problem. It increases the overall radiator view factor to cold space and reduces the overall solar or albedo flux absorbed per unit area of the radiator.

Choi, Michael K.↗

Poly(cyclosilane) Connectivity Tunes Optical Absorbance

We report herein the influence of skeletal connectivity on the conformation-dependent optical properties of cyclosilane homo- and copolymers. 1,3-Linked cyclosilanes were bathochromically shifted by 20 nm in solution relative to 1,4-linked cyclosilanes, an effect reproduced by quantum chemical calculations on oligomeric model systems. Polysilane optical properties are conformation-dependent, and 1,3-linked cyclosilanes were hypothesized to adopt a favorable conformation unavailable to 1,4-linked cyclosilanes constrained to an endocyclic gauche conformation. Copolymerization of the isomeric cyclosilanes 1,3Si 6 and 1,4Si 6 afforded linear statistical copolymers, as characterized by 1 H and 29 Si NMR spectroscopies. The distinct connectivity of each comonomer was found to give rise to tunable absorption spectra, where the position of the absorption band systematically increased with the increased corporation of 1,3Si 6 . Computational studies pointed to conformation-dependent changes in orbital symmetry in shifting the most intense transition from the low-energy highest occupied molecular orbital (HOMO) → lowest unoccupied molecular orbital (LUMO) transition to a higher-energy HOMO → LUMO + n transition. Here, the results of these studies demonstrate for the first time the role of silicon skeletal connectivity in controlling conformation and optoelectronic properties and provide new insight into the structure-based design of solution-processable silicon-based polymeric materials.

36 MATERIALS SCIENCE↗

Absorption of Solar Radiation by Clouds: An Overview

This talk provides an overview of the subject of absorption of solar radiation by clouds in the earth's atmosphere. The paper summarizes the available evidence which points to disagreements between theoretical and observed values of cloud absorption (and reflections). The importance of these discrepancies, particularly to remote sensing of clouds as well as to studies of cloud physics and earth radiation budgets, is emphasized. Existing cloud absorption and reflection measurements are reviewed and the persistent differences that exist between calculated and measured near-infrared cloud albedos are highlighted. Various explanations for these reflection and absorption discrepancies are discussed under two separate paths: a theoretician's approach and an experimentalist's approach. Examples for the former approach include model accuracy tests, large-droplet hypothesis, excess absorbing aerosol, enhanced water vapor continuum absorption, and effects of cloud inhomogeneity. The latter approach focuses on discussions of instrumental device, calibration, operational strategy, and signal/noise separation. A recommendation for future activities on this subject will be given.

Tsay, Si-Chee↗

Stage Cylindrical Immersive Display

Panoramic images with a wide field of view intend to provide a better understanding of an environment by placing objects of the environment on one seamless image. However, understanding the sizes and relative positions of the objects in a panorama is not intuitive and prone to errors because the field of view is unnatural to human perception. Scientists are often faced with the difficult task of interpreting the sizes and relative positions of objects in an environment when viewing an image of the environment on computer monitors or prints. A panorama can display an object that appears to be to the right of the viewer when it is, in fact, behind the viewer. This misinterpretation can be very costly, especially when the environment is remote and/or only accessible by unmanned vehicles. A 270 cylindrical display has been developed that surrounds the viewer with carefully calibrated panoramic imagery that correctly engages their natural kinesthetic senses and provides a more accurate awareness of the environment. The cylindrical immersive display offers a more natural window to the environment than a standard cubic CAVE (Cave Automatic Virtual Environment), and the geometry allows multiple collocated users to simultaneously view data and share important decision-making tasks. A CAVE is an immersive virtual reality environment that allows one or more users to absorb themselves in a virtual environment. A common CAVE setup is a room-sized cube where the cube sides act as projection planes. By nature, all cubic CAVEs face a problem with edge matching at edges and corners of the display. Modern immersive displays have found ways to minimize seams by creating very tight edges, and rely on the user to ignore the seam. One significant deficiency of flat-walled CAVEs is that the sense of orientation and perspective within the scene is broken across adjacent walls. On any single wall, parallel lines properly converge at their vanishing point as they should, and the sense of perspective within the scene contained on only one wall has integrity. Unfortunately, parallel lines that lie on adjacent walls do not necessarily remain parallel. This results in inaccuracies in the scene that can distract the viewer and subtract from the immersive experience of the CAVE.

Abramyan, Lucy↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal photon sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

61 RADIATION PROTECTION AND DOSIMETRY↗

The photoelectric heating mechanism for very small graphitic grains and polycyclic aromatic hydrocarbons

We have theoretically modeled the gas heating associated with the photoelectric ejection of electrons from a size distribution of interstellar carbon grains which extends into the molecular domain. We have considered a wide range of physical conditions for the interstellar gas (1 less than G(sub 0) less than 10(exp 5), with G(sub 0) being the intensity of the incident far-UV field in units of the Habing interstellar radiation field; 2.5 x 10( exp -3) less than n(sub e) less than 75/cu cm, with n(sub e) being the electron density; 10 less than T less than 10,000 K, with T being the gas temperature). The results show that about half of the heating is due to grains less than 1500 C atoms (less than 15 A). The other half originates in somewhat larger grains (1500-4.5 x 10(exp 5) C atoms; 15 less than 100 A). While grains larger than this do absorb about half of the available far-UV photons, they do not contribute appreciably to the gas heating. This strong dependence of gas heating on size results from the decrease in yield and from the increased grain charge (hence larger Coulomb losses) with increasing grain size. We have determined the net photoelectric heating rate and evaluated a simple analytical expression for the heating efficiency, dependent only on G(sub 0), T, and n(sub e). This expression is accurate to 3% over the whole parameter range and is valid up to gas temperatures of 10(exp 4) K, at which point the dominant gas-dust heat exchange mechanism becomes the recombination of electrons with grains rather than photoelectric ejection. The calculated heating efficiency for neutral grains is in good agreement with that derived from observations of the diffuse interstellar clouds. Our results also agree well with the Far Infrared Absolute Spectrometer (FIRAS) observations on the Cosmic Background Explorer Satellite. Finally, our photoelectric heating efficiency is compared to previous studies.

Bakes, E. L. O.↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan Krishnan↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan K.↗

Specific absorbed fractions for a revised series of the UF/NCI pediatric reference phantoms: internal electron sources

Assessment of radiation absorbed dose to internal organs of the body from the intake of radionuclides, or in the medical setting through the injection of radiopharmaceuticals, is generally performed based upon reference biokinetic models or patient imaging data, respectively. Biokinetic models estimate the time course of activity localized to source organs. The time-integration of these organ activity profiles are then scaled by the radionuclide S-value, which defines the absorbed dose to a target tissue per nuclear transformation in various source tissues. S-values are computed using established nuclear decay information (particle energies and yields), and a parameter termed the specific absorbed fraction (SAF). The SAF is the ratio of the absorbed fraction—fraction of particle energy emitted in the source tissue that is deposited in the target tissue—and the target organ mass. While values of the SAF may be computed using patient-specific or individual-specific anatomic models, they have been more widely available through the use of computational reference phantoms. In this study, we report on an extensive series of photon SAFs computed in a revised series of the University of Florida and the National Cancer Institute pediatric reference phantoms which have been modified to conform to the specifications embodied in the ICRP reference adult phantoms of Publication 110 (e.g. organs modeled, organ ID numbers, blood contribution to elemental compositions). Following phantom anatomical revisions, photon radiation transport simulations were performed using MCNPX v2.7 in each of the ten phantoms of the series—male and female newborn, 1 year old, 5 year old, 10 year old, and 15 year old—for 60 different tissues serving as source and/or target regions. A total of 25 photon energies were considered from 10 keV to 10 MeV along a logarithm energy grid. Detailed analyses were conducted of the relative statistical errors in the Monte Carlo target tissue energy deposition tallies at low photon energies and over all energies for source–target combinations at large intra-organ separation distances. Based on these analyses, various data smoothing algorithms were employed, including multi-point weighted data smoothing, and log–log interpolation at low energies (1 keV and 5 keV) using limiting SAF values based upon target organ mass to bound the interpolation interval. The final dataset is provided in a series of ten electronic supplemental files in MS Excel format. Finally, the results of this study were further used as the basis for assessing the radiative component of internal electron source SAFs as described in our companion paper (Schwarz et al 2021) for this same pediatric phantom series.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Role of Intermolecular Interactions in Deep Eutectic Solvents for CO 2 Capture: Vibrational Spectroscopy and Quantum Chemical Studies

Recent research and reviews on CO 2 capture methods, along with advancements in industry, have highlighted high costs and energy-intensive nature as the primary limitations of conventional direct air capture and storage (DACS) methods. In response to these challenges, deep eutectic solvents (DESs) have emerged as promising absorbents due to their scalability, selectivity, and lower environmental impact compared to other absorbents. However, the molecular origins of their enhanced thermal stability and selectivity for DAC applications have not been explored before. Therefore, the current study focuses on a comprehensive investigation into the molecular interactions within an alkaline DES composed of potassium hydroxide (KOH) and ethylene glycol (EG). Combining Fourier transform infrared (FT-IR) and quantum chemical calculations, the study reports structural changes and intermolecular interactions induced in EG upon addition of KOH and its implications on CO 2 capture. Experimental and computational spectroscopic studies confirm the presence of noncovalent interactions (hydrogen bonds) within both EG and the KOH-EG system and point to the aggregation of ions at higher KOH concentrations. Additionally, molecular electrostatic potential (MESP) surface analysis, natural bond orbital (NBO) analysis, quantum theory of atoms-in-molecules (QTAIM) analysis, and reduced density gradient-noncovalent interaction (RDG-NCI) plot analysis elucidate changes in polarizability, charge distribution, hydrogen bond types, noncovalent interactions, and interaction strengths, respectively. Evaluation of explicit and hybrid models assesses their effectiveness in representing intermolecular interactions. This research enhances our understanding of molecular interactions in the KOH-EG system, which are essential for both the absorption and desorption of CO 2 . The study also aids in predicting and selecting DES components, optimizing their ratios with salts, and fine-tuning the properties of similar solvents and salts for enhanced CO 2 capture efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiative transfer in cometary dust atmospheres: Critique of recent developments

The gas and dust production rates of comets near the sun are intimately linked to the fate of the solar radiation as it is scattered and partially absorbed by the cometary dust envelope or halo surrounding the comet's nucleus. The radiation of nuclear matter (mostly water ice) and the release of dust particles embedded in the ice which are entrained by the escaping gas and subsequently form a dust atmosphere or halo. On the other hand, the interaction of the dust cloud with the solar radiation is in turn responsible for the amount of radiative energy received by the nucleus and thus determines the evaporation rate. It is shown that recent attempts to formulate this problem quantitatively are in error. The correct formulation is given and it is pointed out that negative extinction (enhancement of the primary radiation received by the nucleus due to multiple scattering) may not be as large as predicted.

Vonroos, O.↗

Application of formal optimization techniques in thermal/structural design of a heat-pipe-cooled panel for a hypersonic vehicle

Nonlinear mathematical programming methods are used to design a radiantly cooled and heat-pipe-cooled panel for a Mach 6.7 transport. The cooled portion of the panel is a hybrid heat-pipe/actively cooled design which uses heat pipes to transport the absorbed heat to the ends of the panel where it is removed by active cooling. The panels are optimized for minimum mass and to satisfy a set of heat-pipe, structural, geometric, and minimum-gage constraints. Two panel concepts are investigated: cylindrical heat pipes embedded in a honeycomb core and an integrated design which uses a web-core heat-pipe sandwich concept. The latter was lighter and resulted in a design which was less than 10 percent heavier than an all actively cooled concept. The heat-pipe concept, however, is redundant and can sustain a single-point failure, whereas the actively cooled concept cannot. An additional study was performed to determine the optimum number of coolant manifolds per panel for a minimum-mass design.

Camarda, Charles J.↗

Studies of Long Period Variability in Neutron Star HMXB Systems

The purpose of this effort was to investigate the long term, quasi-periodic variability of the X-ray emission from the accreting X-ray pulsars LMC X-4 and SMC X-1. These high mass X-ray binary (HMXB) sources are known to vary in a nearly periodic fashion with cycle lengths of about 30 and 60 days respectively. The prevailing model for such behavior is that it is due to the precession of a tilted accretion disk around the neutron star which is the source of the X-ray emission. As the disk precesses, it periodically obscures the emitting region, resulting in reduced flux as observed at the Earth. The obscuration is not strictly periodic, as the disk precession period changes as the total mass and size of the disk change through variable accretion processes. This model is well established for the long-period variability in the X-ray pulsar Her X-1. With this work, my collaborators and I sought to test whether this model works for LMC X-4 and SMC X-1. Observations with the pointed instruments on the Rossi X-ray Timing Explorer (RXTE) were carried out in order to observe changes in the X-ray spectrum and total flux which were correlated with the long period cycles in these objects. One of the main predictions of the precessing disk model is that the periods of low emission are caused not by changes in the central source, but by increased absorption of that flux as seen at the Earth. Such behavior would be observed in the X-ray spectrum as a relative lack of low energy X-rays (which are more easily absorbed) as compared to high energy X-rays. This is what was observed for SMC X-1, landing strong support to the precessing disk model for this system. For LMC X-1, however, the absorption was consistent with zero at the time of minimum flux. The entire spectrum appeared to be equally reduced. This is not supporting evidence for the model. However, it also does not rule out a precessing disk. If at the time of minimum flux, the intervening disk is so thick that no flux, even high energy X-rays, can penetrate, and if there is material above the disk which can scatter X-rays, then a small scattered spectrum will be seen which is indistinguishable from the unobscured source flux. This is quite possibly the case in LMC X-1.

Heindl, William A.↗

Application of the MAT 213 Composite Impact Model to NASA Problems of Interest

A material model has been developed which incorporates several key capabilities which have been identified as lacking in currently available composite impact models. The material model utilizes experimentally based tabulated input to define the evolution of plasticity and damage as opposed to specifying discrete input parameters (such as modulus and strength). The material model has been implemented into LS-DYNA® as MAT 213. The model can simulate the nonlinear deformation, damage and failure that takes place in a composite under dynamic loading conditions. The deformation model utilizes an orthotropic plasticity formulation. For the damage model, the nonlinear unloading response that is observed prior to the point where the peak stress is reached can be simulated, as well as the stress degradation response that occurs after the peak stress is reached. A variety of failure models, including a generalized tabulated failure model which facilitates the utilization of general failure surfaces, have been implemented into MAT 213. Recent studies at NASA have concentrated on using MAT 213 to analyze both the impact and crush response of a variety of laminated and textile architectures. Several of these studies will be discussed in the presented paper. For example, a woven carbon/Kevlar composite is currently being examined for use in an energy absorber system for rotorcraft structures. MAT 213 analyses have been conducted to examine the ability of the model to accurately simulate the dynamic crush response of this material. Studies are also being conducted to examine the ability of MAT 213 to simulate the ballistic impact response of representative laminated and woven thermoplastic and thermoset matrix composites. NASA efforts are also concentrated on developing methods and processes for improving characterization methods and developing “best practices” for using MAT 213, a summary of which will be discussed in the paper.

Polymer Matrix Composites↗

Co-deposition of hole-selective contact and absorber for improving the processability of perovskite solar cells

Simplifying the manufacturing processes of renewable energy technologies is crucial to lowering the barriers to commercialization. In this context, to improve the manufacturability of perovskite solar cells (PSCs), here we have developed a one-step solution-coating procedure in which the hole-selective contact and perovskite light absorber spontaneously form, resulting in efficient inverted PSCs. We observed that phosphonic or carboxylic acids, incorporated into perovskite precursor solutions, self-assemble on the indium tin oxide substrate during perovskite film processing. They form a robust self-assembled monolayer as an excellent hole-selective contact while the perovskite crystallizes. Our approach solves wettability issues and simplifies device fabrication, advancing the manufacturability of PSCs. Our PSC devices with positive-intrinsic-negative (p-i-n) geometry show a power conversion efficiency of 24.5% and retain >90% of their initial efficiency after 1,200 h of operating at the maximum power point under continuous illumination. The approach shows good generality as it is compatible with different self-assembled monolayer molecular systems, perovskites, solvents and processing methods.

14 SOLAR ENERGY↗

Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models

A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.

Mir Project↗