Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Inclusive prompt photon-jet correlations as a probe of gluon saturation in electron-nucleus scattering at small x

We compute the differential cross-section for inclusive prompt photon+quark production in deeply inelastic scattering of electrons off nuclei at small x (e + A DIS) in the framework of the Color Glass Condensate effective field theory. The result is expressed as a convolution of the leading order (in the strong coupling α s ) impact factor for the process and universal dipole matrix elements, in the limit of hard photon transverse momentum relative to the nuclear saturation scale Q s,A (x). We perform a numerical study of this process for the kinematics of the Electron-Ion Collider (EIC), exploring in particular the azimuthal angle correlations between the final state photon and quark. We observe a systematic suppression and broadening pattern of the back-to-back peak in the relative azimuthal angle distribution, as the saturation scale is increased by replacing proton targets with gold nuclei. Our results suggest that photon+jet final states in inclusive e + A DIS at high energies are in general a promising channel for exploring gluon saturation that is complementary to inclusive and diffractive dijet production. They also provide a sensitive empirical test of the universality of dipole matrix elements when compared to identical measurements in proton-nucleus collisions. However because photon+jet correlations at small x in EIC kinematics require jet reconstruction at small k ⊥ , it will be important to study their feasibility relative to photon-hadron correlations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Deterministic Electron, Photon, Proton and Heavy Ion Radiation Transport Suite for the Study of the Jovian System

A deterministic suite of radiation transport codes, developed at NASA Langley Research Center (LaRC), which describe the transport of electrons, photons, protons, and heavy ions in condensed media is used to simulate exposures from spectral distributions typical of electrons, protons and carbon-oxygen-sulfur (C-O-S) trapped heavy ions in the Jovian radiation environment. The particle transport suite consists of a coupled electron and photon deterministic transport algorithm (CEPTRN) and a coupled light particle and heavy ion deterministic transport algorithm (HZETRN). The primary purpose for the development of the transport suite is to provide a means for the spacecraft design community to rapidly perform numerous repetitive calculations essential for electron, proton and heavy ion radiation exposure assessments in complex space structures. In this paper, the radiation environment of the Galilean satellite Europa is used as a representative boundary condition to show the capabilities of the transport suite. While the transport suite can directly access the output electron spectra of the Jovian environment as generated by the Jet Propulsion Laboratory (JPL) Galileo Interim Radiation Electron (GIRE) model of 2003; for the sake of relevance to the upcoming Europa Jupiter System Mission (EJSM), the 105 days at Europa mission fluence energy spectra provided by JPL is used to produce the corresponding dose-depth curve in silicon behind an aluminum shield of 100 mils ( 0.7 g/sq cm). The transport suite can also accept ray-traced thickness files from a computer-aided design (CAD) package and calculate the total ionizing dose (TID) at a specific target point. In that regard, using a low-fidelity CAD model of the Galileo probe, the transport suite was verified by comparing with Monte Carlo (MC) simulations for orbits JOI--J35 of the Galileo extended mission (1996-2001). For the upcoming EJSM mission with a potential launch date of 2020, the transport suite is used to compute the traditional aluminum-silicon dose-depth calculation as a standard shield-target combination output, as well as the shielding response of high charge (Z) shields such as tantalum (Ta). Finally, a shield optimization algorithm is used to guide the instrument designer with the choice of graded-Z shield analysis.

Norman, Ryan B.↗

Dispersed fluorescence observations of the CO/A 1Pi to X 1Sigma+/ transitions from photodissociation of CO2

The spectra of vacuum ultraviolet (vuv) fluorescence resulting from the excitation of CO2 by photons from an intense line emission source at 15 wavelengths in the range 449-955 A were obtained. The vibrational population distributions for the v = 0, 1, and 2 levels of the CO(A 1Pi) fragments were obtained at several incident photon wavelengths from 700 to 923 A. At incident photon wavelengths of 901 and 923, the relative intensities of the CO(A to X) bands were determined, permitting examination of the variation of the electronic transition moment with the r centroid.

Phillips, E.↗

GRO: Black hole models for gamma-ray bursts

The Burst and Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory (CGRO) has established that the distribution of gamma-ray bursts (GRB's) is isotropic but is bound radially. This finding suggests that the bursts are either cosmological or they originate from an extended Galactic halo. The implied luminosities and the observed variability of the GRB's on time scales as short as one millisecond suggest that they originate from compact objects. We are presently studying black hole models for GRB's. Any such model must produce a non-thermal photon spectrum to agree with the observed properties. For a wide range of burst parameters the assumed bursting source consists of a non-thermal electron-positron-photon plasma of very high density. It seems possible to produce such a plasma in accretion onto black holes. In our on-going work, we are developing the kinetic theory for a non-equilibrium pair plasma. The main new features of our work are as follows: (1) We do not assume the presence of a thermal electron bath. (2) Non-thermal, high-energy pairs are allowed to have an arbitrary concentration and energy distribution. (3) There is no soft photon source in our model; initially all the photons in the plasma are either energetic X-rays or gamma-rays. (4) The initial energy distribution of the pairs as well as photons is arbitrary. (5) We collect the analytical expressions for the kinetic kernels for all relevant processes. And (6) we present a different approach to finding the time-evolution of pair and photon spectra, which is a combination of the kinetic-theory and the non-linear Monte-Carlo schemes. We have developed many Monte-Carlo programs to model various process, to take into account the time evolution, and to incorporate various physical effects which are unique to non-thermal plasmas. The hydrodynamics of fireballs in GRB's was studied before. Applying results from kinetic theory will improve our understanding of these systems.

Ruderman, Malvin↗

Event Pileup in AXAF's ACIS CCD Camera

AXAF's high resolution mirrors will focus a point source near the optical axis to a spot that is contained within a radius of about two pixels on the ACIS Charge Coupled Devices (CCD) camera. Because of the small spot size, the accuracy to which fluxes and spectral energy distributions of bright point sources can be measured will be degrad3ed by event pileup. Event pileup occurs when two or more X-ray photons arrive simultaneously in a single detection cell on a CCD readout frame. When pileup occurs, ACIS's event detection algorithm registers the photons as a single X-ray event. The pulse height channel of the event will correspond to an energy E approximately E-1 + E-2...E-n, where n is the number of photons registered per detection cell per readout frame. As a result, pileup artificially hardens the observed spectral energy distribution. I will discuss the effort at the AXAF Science Center Lo calibrate pileup in ACIS using focused, nearly monochromatic X-ray source. I will discuss techniques for modeling and correcting pileup effects in polychromatic spectra.

McNamara, Brian R.↗

Emission-line variability and the broad-line region of quasi-stellar objects. I - Time scales and photon densities

Spectroscopic data for five low-redshift QSOs taken over several years are presented as evidence for emission-line variability in QSOs. The broad hydrogen emission lines in the QSOs 0026 + 129, 1202 + 281, 1612 + 261, and 2141 + 175 are found to vary in step with their underlying continua. Another QSO, 2135 - 147, shows an increase in the intensities of its hydrogen lines five years after the increase in its continuum level. The inferred upper limit to the size of the broad emission line region is smaller than 3 lt-yr, probably as small as 0.4 lt-yr for 0026 + 129, if the line-emitting region is spherically distributed. Such a small size implies a very high density of ionizing photons, of the order of 10 to the 10th/cu cm. A very high nucleon density must then be assumed in order to obtain a value of the ionization parameter consistent with current photoionization models.

Zheng, Wei↗

On-chip parallel processing of quantum frequency comb

Abstract The frequency degree of freedom of optical photons has been recently explored for efficient quantum information processing. Significant reduction in hardware resources and enhancement of quantum functions can be expected by leveraging the large number of frequency modes. Here, we develope an integrated photonic platform for the generation and parallel processing of quantum frequency combs (QFCs). Cavity-enhanced parametric down-conversion with Sagnac configuration is implemented to generate QFCs with identical spectral distributions. On-chip quantum interference of different frequency modes is simultaneously realized with the same photonic circuit. High interference visibility is maintained across all frequency modes with the identical circuit setting. This enables the on-chip reconfiguration of QFCs. By deterministically separating QFCs without spectral filtering, we further demonstrate high-dimensional Hong-Ou-Mandel effect. Our work provides the critical step for the efficient implementation of quantum information processing with integrated photonics using the frequency degree of freedom.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The physics of light distribution in hollow structures

The purpose of this paper is to serve as an introduction, for non-physicists, to the subject of light distribution in hollow structures. The motivation for light distribution is the importance of getting the maximum value from available light. We all recognize that photons cost money (one photon costs about $10(exp -25) to make) so we obviously want to try to make the maximum number of photons for a given cost. What is often overlooked, however, is that these photons have the highest value only if they are delivered to the right place in the correct quantity. This means that there is often substantial economic value in the high quality distribution of light. This problem is discussed from a very general perspective, in order to show the role of general optical films for manipulating light. The underlying physics at work in such films is described, and examples of common optical light distribution films are provided.

Whitehead, Lorne A.↗

High-speed volumetric two-photon fluorescence imaging of neurovascular dynamics

Abstract Understanding the structure and function of vasculature in the brain requires us to monitor distributed hemodynamics at high spatial and temporal resolution in three-dimensional (3D) volumes in vivo. Currently, a volumetric vasculature imaging method with sub-capillary spatial resolution and blood flow-resolving speed is lacking. Here, using two-photon laser scanning microscopy (TPLSM) with an axially extended Bessel focus, we capture volumetric hemodynamics in the awake mouse brain at a spatiotemporal resolution sufficient for measuring capillary size and blood flow. With Bessel TPLSM, the fluorescence signal of a vessel becomes proportional to its size, which enables convenient intensity-based analysis of vessel dilation and constriction dynamics in large volumes. We observe entrainment of vasodilation and vasoconstriction with pupil diameter and measure 3D blood flow at 99 volumes/second. Demonstrating high-throughput monitoring of hemodynamics in the awake brain, we expect Bessel TPLSM to make broad impacts on neurovasculature research.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Three Body Decays in Quasi-Real Photoproduction

This thesis presents preliminary measurements of the moments of angular distribution for the K?K+ mesonic final state using a quasi-real, linearly polarised photon. Two of the main points of focus for this analysis were the development of the formalism for photoproduced vector-pseudoscalar decay and the tools by which the analysis was carried out. The formalism described how the moments of angular distribution could be extracted from the angular decay variables, and how they related to resonance decays in terms of partial waves. In extracting the moments, it was found that adapted Markov Chain Monte Carlo (MCMC) methods proved to be more effective in terms of extracting results from the data compared to the sole use of gradient descent based fitting algorithms. These measurements are complementary to other decay channels and production mechanisms, with the global aim of probing the existence of exotic mesons. Data from this analysis was taken by the CLAS collaboration at the Thomas Jefferson National Accelerator Facility (JLab) by scattering from a liquid hydrogen target using a 10.6 GeV electron. This work was done within the MesonEx program at CLAS12 that aims to map the spectrum of mesons, and in doing so, gain a greater understanding of Quantum ChromoDynamics (QCD) and the strong force.

Wishart, Robert↗

Maximizing quantum enhancement in axion dark matter experiments

We provide a comprehensive comparison of linear amplifiers and microwave photon counters in axion dark matter experiments. The study is done assuming a range of realistic operating conditions and detector parameters, over the frequency range between 1 and 30 GHz. As expected, photon counters are found to be advantageous under low background, at high frequencies (𝜈 >5 GHz), if they can be implemented with robust wide-frequency tuning or a very low dark count rate. Additional noteworthy observations emerging from this study include: (1) an expanded applicability of off-resonance photon background reduction, including the single-quadrature state squeezing, for scan rate enhancements; (2) a much broader appeal for operating the haloscope resonators in the overcoupling regime, up to 𝛽 ∼10; (3) the need for a detailed investigation into the cryogenic and electromagnetic conditions inside haloscope cavities to lower the photon temperature for future experiments; (4) the necessity to develop a distributed network of coupling ports in high-volume axion haloscopes to utilize these potential gains in the scan rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photonuclear tomography in ultraperipheral heavy-ion collisions

We present a theoretical investigation of photonuclear tomography as a novel technique for probing the internal structure of nuclei. In this approach, ultraperipheral heavy-ion collisions (UPCs) serve as a source of intense fluxes of virtual photons, which induce coherent production of vector mesons. By analyzing the probabilities and cross sections of these photon-induced processes, we propose a methodology for reconstructing the spatial distribution of nucleons within the nucleus. Our framework provides a systematic way to access information on the nuclear geometry probed in UPCs, offering new opportunities for studies of nuclear structure using particle production as a probe. Numerical calculations for selected examples illustrate the feasibility and potential of this method.

particle & resonance production↗

Miniaturized integrated spectrometer using a silicon ring-grating design

We introduce and experimentally demonstrate a miniaturized integrated spectrometer operating over a broad bandwidth in the short-wavelength infrared (SWIR) spectrum that combines an add-drop ring resonator narrow band filter with a distributed Bragg reflector (DBR) based broadband filter realized in a silicon photonic platform. The contra-directional coupling DBR filter in this design consists of a pair of waveguide sidewall gratings that act as a broadband filter (i.e., 3.9 nm). The re-directed beam is then fed into the ring resonator which functions as a narrowband filter (i.e., 0.121 nm). In this scheme the free spectral range (FSR) limitation of the ring resonator is overcome by using the DBR as a filter to isolate a single ring resonance line. The overall design of the spectrometer is further simplified by simultaneously tuning both components through the thermo-optic effect. Moreover, several ring-grating spectrometer cells with different central wavelengths can be stacked in cascade in order to cover a broader spectrum bandwidth. This can be done by centering each unit cell on a different center wavelength such that the maximum range of one-unit cell corresponds to the minimum range of the next unit cell. This configuration enables high spectral resolution over a large spectral bandwidth and high extinction ratio (ER), making it suitable for a wide variety of applications.

42 ENGINEERING↗

Beam Commissioning Result of Polarized Target at SpinQuest

SpinQuest is a fixed-target experiment at Fermilab to measure the Drell-Yan process using transversely polarized NH$_3$ and ND$_3$ targets and unpolarized 120-GeV proton beam. In the Drell-Yan process, a quark in one scattering hadron and an anti-quark in the other hadron annihilate into a virtual photon and then decay into a muon (lepton) pair. The angular distribution of final-state muon pairs with respect to the target polarization is sensitive to the Sivers function of light antiquarks in the nucleon, which is one of the eight Transverse Momentum Dependent (TMD) parton distribution functions. The intensity of the proton beam is as high as $10^{12}$ protons/second, in order to accumulate the required statistics of Drell-Yan events. The polarized target system at SpinQuest has been carefully designed to accommodate such a high beam intensity. It is equipped with an evaporation refrigerator with a cooling power of around 5 W at 1 K. The target temperature is maintained at 1 K even under heat load caused by the proton beam and the DNP microwave. The target system and the spectrometer were commissioned with the proton beam from May through July 2024. The experimental setup of SpinQuest and the performance of the target system during the beam commissioning is reported.

Nakano, Kenichi [Virginia U.]↗

Selected Theoretical Studies Group contributions to the 14th International Cosmic Ray conference

The galactic distribution of H2 was studied through gamma radiation and through X-ray, optical, and infrared absorption measurements from SAS-2 and other sources. A comparison of the latitude distribution of gamma-ray intensity with reddening data shows reddening data to give the best estimate of interstellar gas in the solar vicinity. The distribution of galactic cosmic ray nucleons was determined and appears to be identical to the supernova remnant distribution. Interactions between ultrahigh energy cosmic-ray nuclei and intergalactic photon radiation fields were calculated, using the Monte Carlo method.

Source record↗

Compton scattering of microwave background radiation by gas in galaxy clusters

Based on data on the X-ray spectrum of the Coma cluster, interpreted as thermal bremsstrahlung, the expected brightness depletion from Compton scattering of the microwave background in the direction of the cluster is computed. The calculated depletion is about one-third that recently observed by Gull and Northover, and the discrepancy is discussed. In comparing the observed microwave depletion in the direction of other clusters which are X-ray sources it is found that there is no correlation with the cluster X-ray luminosity. Consequently, the microwave depletion observations cannot yet be taken as good evidence for a thermal bremsstrahlung origin for the X-ray emission. The perturbation from Compton scattering of photons on the high-frequency (Wien) tail of the blackbody distribution is computed and found to be much larger than predicted in previous calculations. In the Wien tail the effect is a relative increase in the blackbody intensity that is appreciably greater in magnitude than the depletion in the Rayleigh-Jeans domain.

Gould, R. J.↗

Nucleon-nucleus interactions from JACEE

Results on hadron-nucleus interactions from the Japanese-American Cooperation Emulsion Experiment experiment are presented. Angular distributions for charged particles, and angular and transverse momentum spectra for photons have been measured for a sample of events with sigma epsilon sub gamma. Results on central rapidity density and transverse energy flow are discussed.

Burnett, T. H.↗

Detection of a flaring low-energy gamma-ray source

We report the detection of a flaring gamma-ray source by the University of New Hampshire (UNH) balloon-borne coded aperture gamma-ray telescope (DGT) on 1984 October 2. The source was detected at the significance level of 7.2 sigma over the energy range 160-2000 keV. The intensity in the range (160-200) keV was 1.1 Crab. The best-fit position of the source is given by R.A. = 3h 25.8m and Decl. = 67 deg 653 min and is located in the constellation of Camelopardia. The source was visible within the Field of View (FOV) of the telescope for approximately = 2 hr and exhibited signs of flaring. The derived photon spectrum can be equally fitted by an optically thin bremsstrahlung distribution of kT approximately = 52 keV or a power law of the form, dN(E)/dE = 3.7 x 10(exp -6) (E/400)(exp -4.5) photons/sq cm/keV. We compare its spectral characteristics ad energy output to various types of fast X-ray transients. No measurable flux could be detected from CG 135+1, the COS B source which was in the FOV and therefore, we present 2 sigma upper flux limits on its spectral emission over the energy range 160 keV to 9.3 MeV.

Bhattacharya, Dipen↗