A far ultraviolet photometer for space research
Far UV photometer for space research, isolating specific bands by combining spectral response of individual solar blind photocathodes with thin metallic films transmission qualities
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Far UV photometer for space research, isolating specific bands by combining spectral response of individual solar blind photocathodes with thin metallic films transmission qualities
Transmission and reflection light losses are reduced by introducing light into end-window of device at an angle large enough to normal so total internal reflection occurs at both photocathode-vacuum and window-air interfaces.
Utilization of optical enhancement techniques prevents loss of light by reflections at the photocathode of a photomultiplier and increases signal detection sensitivity.
The engineering development of the SEC vidicon as an astronomical sensor has continued in parallel with its operational use. One scientific application was the six hour exposure of the quasar PHL-957 at the Coude spectrograph of the 200-inch Hale telescope. The developmental effort includes both the enhancement of the basic attributes that make the SEC an appropriate sensor, namely, high quantum efficiency, low threshold, and long integration; as well as work to broaden its scientific usefulness, such as the development of a MgF2 photocathode window for vacuum ultraviolet sensitivity, and a permanent magnet focus design for thermal compatibility with proposed large space telescopes. Additional details on the characteristics of the SEC tube are discussed, as well as plans to make a larger and higher resolution version.
Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. The performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode is discussed. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope 2 for direct high resolution imagery is also discussed. The paper also discusses the large space telescope image sensor requirements and the development of a larger television tube for this mission.
Princeton Observatory has been working for several years under NASA sponsorship to develop television type sensors to use in place of photographic film for space astronomy. This paper discusses the performance of an SEC-vidicon with a 25 mm x 25 mm active area, MgF2 window, and bi-alkali photocathode. Results from ground based use on the Coude spectrograph of the 200-inch Hale telescope are included. The intended use of this tube in an echelle spectrograph sounding rocket payload and on Stratoscope II for direct high resolution imagery is also discussed. The paper also discusses the Large Space Telescope image sensor requirements and the development of a larger television tube for this mission.
Performance characteristics of Bendix type BX 8025-4522 proximity focused image tubes for ultraviolet to visible light conversion are presented. Quantum efficiency, resolution, background, geometric distortion, and environmental test results are discussed. The converters use magnesium fluoride input windows with Cs - Te photocathodes, and P-11 phosphors on fiber optic output windows.
A technique was developed for improving the precision of laser ranging measurements of ground-to-satellite distances. The method employs a mode-locked laser transmitter and utilizes an image converter tube equipped with deflection plates in measuring the time of flight of the laser pulse to a distant retroreflector and back. Samples of the outgoing and returning light pulses are focussed on the photocathode of the image converter tube, whose deflection plates are driven by a high-voltage 120 MHz sine wave derived from a very stable oscillator. From the relative positions of the images produced at the output phosphor by the two light pulses, it is possible to make a precise determination of the fractional amount by which the time of flight exceeds some large integral multiple of the period of the deflection sinusoid.
Capabilities and limitations of infrared imaging systems are discussed, and a real-time simulator for image data systems is described. Ultrahigh resolution electronic imaging and storage with the return beam vidicon is treated, and a description is given of an electron-lens for opaque photocathodes. Ground surveillance with an active low light level TV, digital processing of Mariner 9 TV data, image enhancement by holography, and application of data compression techniques to spacecraft imaging systems are given attention. Individual items are announced in this issue.
Performance characteristics of Bendix type BX08025-4522 proximity-focussed vacuum-ultraviolet to visible-light image converters are presented. The converters are to be used with SEC vidicons as detectors for an echelle spectrograph on the International Ultraviolet Explorer astronomical satellite. Magnesium fluoride input windows with Cs-Te photocathodes are used in the converters, with P-11 phosphors on the fiber optic output windows. Quantum efficiencies, modulation transfer function, background, geometric distortion, and environmental test results are presented for the wavelength region from 1150 to 3500 A.-
The papers presented at the symposium are given which deal with the present state of sensors, as may be applicable to the Large Space Telescope (LST) program. Several aspects of sensors are covered including a discussion of the properties of photocathodes and the operational imaging camera tubes.
The digital system is described and compared to other sensor systems. The digicon system starts with a photocathode, has magnetic focusing of the accelerated photoelectrons, and the electrons hit an array of solid-state diodes. These characteristics, however, are the only ones which are applicable to both the digicon and the other systems. With the digicon system, instead of attempting to read the resulting charges on the diodes by probing electrons, or by a charge transfer out, an actual physical wire is connected to each separate diode. This provides a huge advantage in improved signal-to-noise ratio.
An improved vidicon image sensor for space astronomy applications is developed that features reliably sealed ultraviolet transmitting windows and achieves acceptable photocathode quantum efficiency on these MgF2 windows. New preamplifier designs improve the dynamic range by reduction of the readout noise.
The fluorescence and phosphorescence of photomultiplier window materials under electron irradiation were investigated using a Sr-90/Y-90 beta emitter as the electron source. Spectral emission curves of UV grade, optical grade, and electron-irradiated samples of MGF2 and LiF, CaF2, BaF2, sapphire, fused silica, and UV transmitting glasses were obtained over the spectral range of 200 nm to 650 nm. Fluorescence yields, expressed as the number of counts in a solid angle of 2 pi steradian per 1MeV of incident electron energy deposited, were determined on these materials utilizing photomultiplier tubes with cesium telluride, bialkali, and trialkali (S-20) photocathodes, respectively.
Performance characteristics of Bendix type BX 8025-4522 proximity focused image tubes for UV to visible light conversion are presented. Quantum efficiency, resolution, background, geometric distortion, and environmental test results are discussed. The converters use magnesium fluoride input windows with Cs-Te photocathodes and P-11 phosphors on fiber optic output windows.
The NASA Balloon-borne Ultraviolet Stellar Spectrometer (BUSS) which is carried to an altitude of 40 km by a 15 million cubic foot balloon for night-time observations of ultraviolet stellar spectra is discussed. The BUSS optical system, comprising an 0.40 m aperture Cassegrain telescope and an Ebert-Fastie spectrometer, points at various selected stars and focuses a portion of their spectra on the photocathode of an image dissector tube. The spectral region between 2,775 Angstroms and 2,825 Angstroms is sampled by the detector at 0.25 Angstroms increments using photon counting techniques. The pointing system for the payload uses a pair of orthogonal magnetometers which sense the earth's magnetic field for an aximuth reference, and a platform potentiometer for an elevation reference. This pointing system places the target star within the 3x1 degree field of view of an outer optical star tracker. The outer star tracker is then used to point the entire instrument to within one arc minute of the target star.
The feasibility is examined of increasing the effectiveness of the scintillation and Cerenkov counters through improving light collection of the recorded radiation on the photoelectric cathode of the photomultiplier. An example of how to select a detector of the directional plexiglas Cerenkov counter is given. Also presented are experimentally obtained amplitude distributions during the recording of cosmic ray muons. The necessity to obtain agreement between the characteristic spectrum of the photocathode of the photomultiplier and the spectrum of the recorded radiation is stressed.
The report describes two designs are reported of gas threshold Cerenkov counters for recording electrons of primary cosmic rays without recording protons. Also presented are design and technological measures which ensure maximum light collection of the Cerenkov radiation originating on the photocathode of the photomultiplier inside the radiator. The dependence of the reflection factor on the length of the light wave for different coatings is shown as well as for the throughput of the different optical materials employed. A range of methods for determining the efficiency of the counters during the recording of cosmic ray nucons and ways of increasing it further are given.