Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance loss rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Oxidation of CS2 and COS - sources for atmospheric SO2

The oxidation of COS and CS2 by reaction with hydroxyl radicals is investigated as a possible source of atmospheric SO2 in remote marine regions. Calculations of the vertical profiles of SO2 were performed based on a one-dimensional photochemical model of the formation and destruction of SO2 by various processes for observed O3, CO, CH4 and H2O profiles at 15 deg S. Variations in the rate of SO2 destruction, the chosen deposition velocity and the loss due to aerosols are shown to lead to similar SO2 profiles, which indicate higher mixing ratios at high altitude, while the oxidation of dimethyl sulfide or hydrogen sulfide can not account for the profiles observed. Possible diffuse sources of CS2 and COS are indicated, and it is concluded that the oxidation of COS and possibly CS2 may provide an explanation for the existence of a uniform background level of SO2.

Logan, J. A.↗

Fluid-electrolyte shifts and thermoregulation - Rest and work in heat with head cooling

The effects of head cooling on thermoregulation and associated plasma fluid and electrolyte shifts during rest and submaximal exercise in the heat are investigated. Thermoregulatory responses and plasma volume were measured in four male subjects fitted with liquid-cooled neoprene headgear during 60 min of rest, 60 min of ergometer exercise at 45% maximal oxygen uptake and 30 min of recovery in the supine position at 40.1 C and 40% relative humidity. It is found that, compared to control responses, head cooling decreased thigh sweating and increased mean skin temperature at rest and attenuated increases in thigh sweating, heart rate, rectal temperature and ventilation during exercise. During recovery, cooling is observed to facilitate decreases in sweat rate, heart rate, rectal temperature and forearm blood flow and enhance the increase in average temperature. Cooling had no effect on plasma protein, osmotic or electrolyte shifts, and decreased plasma volume losses. The findings indicate the effectiveness of moderate head cooling for the improvement of human performance during exercise in heat.

Greenleaf, J. E.↗

Wake Steering Wind Farm Control With Preview Wind Direction Information: Preprint

Wake steering is a wind farm control strategy in which upstream turbines operate with a yaw misalignment to deflect their wakes away from downstream turbines, yielding a net power gain for the wind plant. But the inability of wake steering controllers to perfectly track the wind direction leads to suboptimal performance. In this paper, we propose the use of preview wind direction measurements upstream of the turbine to improve controller performance by anticipating wind direction changes. Further, data from an operational wind plant are used to determine realistic preview measurement accuracy. Using the FLORIS engineering wind farm control tool, we compare the performance of standard and preview-enabled baseline and wake steering control for a two-turbine array during below-rated operation. Assuming perfect preview information, preview-based wake steering increases energy production by the equivalent of 9.5% of the baseline wake losses, compared to a wake loss recovery of 5.6% with standard wake steering. However, when realistic measurement accuracy is included, the preview-based controller provides no advantage over standard control, motivating the need for more sophisticated control and wind direction forecasting strategies.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Identification of Cardiometabolic Vulnerabilities Caused by Effects of Synergistic Stressors that are Commonly Encountered During Space Missions

Microgravity is a physiologically challenging state even when at rest. Astronauts experience additional physical and mental stresses, such as prolonged exertion, sleep loss and circadian misalignment, that could impact cardiovascular function. The main goals of this four year NASA project are to characterize the independent and synergistic effects on cardiovascular and immune function of: (1) circadian misalignment; (2) sleep loss; and (3) varied physical and mental stressors, mimicking some of the synergistic stressors experienced by astronauts. Sixteen healthy volunteers, aged 35-55 years, will be studied with standardized behavioral stressors occurring across all circadian phases, both with and without accruing sleep loss, achieved via two 11-day "forced desynchrony" protocols performed in each subject (randomized, within-subject design), where wake periods are advanced 4-h each "day" (i.e. recurring 20-h "days"). One protocol permits 8.33 h sleep opportunity per 20-h "day" (=10 h sleep per 24-h), and the other permits 5 h sleep per 20-h "day" (=6 h sleep per 24-h; matching the reported sleep duration of astronauts). In both protocols, subjects will perform a standardized stress battery including a cognitively challenging task; bicycle exercise, and passive 60deg head up tilt. Outcome variables include blood pressure, heart rate, arrhythmia frequency, cardiac vagal tone (from heart rate variability), sympathetic activity (catecholamines), and endothelial function. Additional measures of cardiac function (echocardiography), responses to a passive 80deg head up tilt, maximal oxygen uptake, and immune function will be assessed at the beginning and at the end of each protocol (i.e., without and with sleep loss, and before and after circadian misalignment). We hope to identify the relative impact on cardiovascular risk markers of varied behavioural stressors while subjects experience circadian misalignment and sleep loss, mimicking some of the synergistic stressors experienced by astronauts. Supported by NASANNX1 OAR 1 OG.

Ruger, M.↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

The Effect of Inverse Compton Losses on Particle Acceleration in Three-dimensional Relativistic Reconnection

Relativistic magnetic reconnection is a key mechanism for dissipating magnetic energy and accelerating particles in astrophysics. In the absence of radiative cooling, recent particle-in-cell (PIC) simulations have shown that high-energy particles gain most of their energy in the upstream region, during a short-lived “free phase” where they meander between the two sides of the layer; when they get captured/trapped by the downstream flux ropes, they undergo a “trapped phase,” where no significant energization occurs. Here, we perform a suite of 3D PIC simulations of relativistic reconnection, including inverse Compton (IC) losses in the weakly cooled regime in which the radiation-reaction-limited Lorentz factor γrad exceeds the magnetization σ. We show that electron cooling losses do not appreciably alter the reconnection rate, the structure of the layer, and the physics of particle acceleration in the free phase, so the spectrum of free electrons is dN free /dγ ∝ γ −1 , as in the uncooled case. The spectrum of trapped electrons above the cooling break γcool (in the range γ cool < γ < γ rad ) is dN/dγ ∝ γ −3 , steeper than the scaling dN/dγ ∝ γ −2 of uncooled simulations. This confirms that no significant particle energization occurs during the trapped phase. Our results validate the model by Zhang et al. for particle acceleration in 3D relativistic reconnection, and imply that radiative emission models of reconnection-powered astrophysical sources should employ a two-zone structure that differentiates between free, rapidly accelerating particles and trapped, passively cooling particles.

79 ASTRONOMY AND ASTROPHYSICS↗

A study of NASA occupational injuries and property damage at Goddard Space Flight Center, Langley Research Center and Headquarters

Analysis of NASA's accident/injury/illness and health data was performed. The analysis included: (1) an on-site study of the existing data; (2) evaluation of the findings to develop criteria for the subsequent implementation of safety and health standards; (3) preparation of a graphical loss control assessment; and (4) recommendations to reduce accident rates.

Source record↗

Io escape and ionization of atmospheric gases

Exploratory model calculations for the Io atomic oxygen cloud have provided two-dimensional sky-plane intensities for the 6300 A, 1304 A and 880 A lines, where volume excitation and ionization rates are determined by impact collisions with Io plasma torus electrons. Comparison of model results with observations at 6300 A suggests an isotropic oxygen flux from Io of about 1.5x109 atoms 1 sq cm/sec. The effects of including a neutral sulfur cloud and also of including charge exchange reactions between plasma torus ions and neutral OI and SI were evaluated to be significant and were roughly estimated to increase the required oxygen flux to 1.2 x 10 to the 10th atoms/sq cm/sec. In addition, increases in the estimates for the ion loading, cloud mass loss, plasma mass loading and ion energy input rates were also made. Model calculations for an Io sulfur cloud, excluding charge exchange reactions but assuming an SI flux of 7.5 x 10 to the 8th atoms/sq cm/sec (i.e., half of the oxygen flux), were also performed and provided sky plane intensities for a number of visible and IR emission lines.

Smyth, W. H.↗

Preliminary Effect of Synthetic Vision Systems Displays to Reduce Low-Visibility Loss of Control and Controlled Flight Into Terrain Accidents

An experimental investigation was conducted to study the effectiveness of Synthetic Vision Systems (SVS) flight displays as a means of eliminating Low Visibility Loss of Control (LVLOC) and Controlled Flight Into Terrain (CFIT) accidents by low time general aviation (GA) pilots. A series of basic maneuvers were performed by 18 subject pilots during transition from Visual Meteorological Conditions (VMC) to Instrument Meteorological Conditions (IMC), with continued flight into IMC, employing a fixed-based flight simulator. A total of three display concepts were employed for this evaluation. One display concept, referred to as the Attitude Indicator (AI) replicated instrumentation common in today's General Aviation (GA) aircraft. The second display concept, referred to as the Electronic Attitude Indicator (EAI), featured an enlarged attitude indicator that was more representative of a glass display that also included advanced flight symbology, such as a velocity vector. The third concept, referred to as the SVS display, was identical to the EAI except that computer-generated terrain imagery replaced the conventional blue-sky/brown-ground of the EAI. Pilot performance parameters, pilot control inputs and physiological data were recorded for post-test analysis. Situation awareness (SA) and qualitative pilot comments were obtained through questionnaires and free-form interviews administered immediately after the experimental session. Initial pilot performance data were obtained by instructor pilot observations. Physiological data (skin temperature, heart rate, and muscle flexure) were also recorded. Preliminary results indicate that far less errors were committed when using the EAI and SVS displays than when using conventional instruments. The specific data example examined in this report illustrates the benefit from SVS displays to avoid massive loss of SA conditions. All pilots acknowledged the enhanced situation awareness provided by the SVS display concept. Levels of pilot stress appear to be correlated with skin temperature measurements.

Glaab, Louis J.↗

The Q weak high performance LH 2 target

A high-power liquid hydrogen target was built for the Jefferson Lab Q weak experiment, which measured the tiny parity-violating asymmetry in $\vec{e}$ p scattering at an incident energy of 1.16 GeV, and a Q 2 = 0.025 GeV 2 . To achieve the luminosity of 1.7 x 10 39 cm -2 s -1 , a 34.5 cm- long target was used with a beam current of 180 μA. The ionization energy-loss deposited by the beam in the target was 2.1 kW. The target temperature was controlled to within ±0.02 K and the target noise (density fluctuations) near the experiment's beam helicity- reversal rate of 960 Hz was only 53 ppm. The 58 liquid liter target achieved a head of 11.4 m (7.6 kPa) and a mass flow of 1.2 ± 0.3 kg/s (corresponding to a volume flow of 17.4 ± 3.8 l/s) at the nominal 29 Hz rotation frequency of the recirculating centrifugal pump. We describe aspects of the design, operation, and performance of this target, the highest power LH2 target ever used in an electron scattering experiment to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Drought conditioning of rhizosphere microbiome influences maize water use traits

Background and Aims: Beneficial plant–microbe interactions can improve plant performance under drought; however, we know less about how drought-induced shifts in microbial communities affect plant traits. Methods: We cultivated Zea mays in fritted clay with soil microbiomes originating from contrasting environments (agriculture or forest) under two irrigation treatments (well-watered or water limited). Using this design, we investigated whether water conditioning was carried forward through the microbiome to affect a subsequent plant cohort that was subjected to either a well-watered or water limited treatment. Results: Regardless of the microbiome-origin, plants inoculated with a microbiome from a water limited legacy had traits that allowed them to avoid stress but conserve water. They produced longer roots to explore soil, generated greater soil dissolved organic carbon, potentially stimulating the microbiome, and slower soil water content loss during drought. A well-watered legacy resulted in plants that delayed permanent stomatal closure and higher photosynthetic nitrogen use efficiency. In plants with a forest-originated microbiome, a well-watered legacy and water treatment also resulted in higher rates of photosynthesis and stomatal conductance. Conclusion: These results demonstrate that soil microbiomes can be developed to influence plant drought performance, impacting crop resilience, using short-term microbial conditioning.

60 APPLIED LIFE SCIENCES↗

High rate studies of the ATLAS sTGC detector and optimization of the filter circuit on the input of the front-end amplifier

Abstract The Large Hadron Collider (LHC) at CERN is expected to be upgraded to the High-Luminosity LHC (HL-LHC) by 2029 and achieve instantaneous luminosity around 5–7.5 × 10 34 cm -2 s -1 . This represents a more than 3–4 fold increase in the instantaneous luminosity compared to what has been achieved in Run 2. The New Small Wheel (NSW) upgrade is designed to be able to operate efficiently in this high background rate environment. In this article, we summarize multiple performance studies of the small-strip Thin Gap Chamber (sTGC) at high rate using nearly final front-end electronics. We demonstrate that the efficiency versus rate distribution can be well described by an exponential decay with electronics dead-time being the primary cause of loss of efficiency at high rate. We then demonstrate several methods that can decrease the electronics dead-time and therefore minimize efficiency loss. One such method is to install either a pi-network input filter or pull-up resistor to minimize the charge input into the amplifier. We optimized the pi-network capacitance and pull-up resistor resistance using the results from our measurements. The results shown here were not only critical to finalizing the components on the front-end board, but also are critical for setting the optimal operating parameters of the sTGC detector and electronics in the ATLAS cavern.

Instruments & Instrumentation↗

Some examples of image warping for low vision prosthesis

NASA has developed an image processor, the Programmable Remapper, for certain functions in machine vision. The Remapper performs a highly arbitrary geometric warping of an image at video rate. It might ultimately be shrunk to a size and cost that could allow its use in a low-vision prosthesis. Coordinate warpings have been developed for retinitis pigmentosa (tunnel vision) and for maculapathy (loss of central field) that are intended to make best use of the patient's remaining viable retina. The rationales and mathematics are presented for some warpings that we will try in clinical studies using the Remapper's prototype.

Juday, Richard D.↗

Stratospheric Heterogeneous Chemistry and Microphysics: Model Development, Validation and Applications

The objectives of this project are to: define the chemical and physical processes leading to stratospheric ozone change that involve polar stratospheric clouds (PSCS) and the reactions occurring on the surfaces of PSC particles; study the formation processes, and the physical and chemical properties of PSCS, that are relevant to atmospheric chemistry and to the interpretation of field measurements taken during polar stratosphere missions; develop quantitative models describing PSC microphysics and heterogeneous chemical processes; assimilate laboratory and field data into these models; and calculate the extent of chemical processing on PSCs and the impact of specific microphysical processes on polar composition and ozone depletion. During the course of the project, a new coupled microphysics/physical-chemistry/ photochemistry model for stratospheric sulfate aerosols and nitric acid and ice PSCs was developed and applied to analyze data collected during NASA's Arctic Airborne Stratospheric Expedition-II (AASE-II) and other missions. In this model, detailed treatments of multicomponent sulfate aerosol physical chemistry, sulfate aerosol microphysics, polar stratospheric cloud microphysics, PSC ice surface chemistry, as well as homogeneous gas-phase chemistry were included for the first time. In recent studies focusing on AASE measurements, the PSC model was used to analyze specific measurements from an aircraft deployment of an aerosol impactor, FSSP, and NO(y) detector. The calculated results are in excellent agreement with observations for particle volumes as well as NO(y) concentrations, thus confirming the importance of supercooled sulfate/nitrate droplets in PSC formation. The same model has been applied to perform a statistical study of PSC properties in the Northern Hemisphere using several hundred high-latitude air parcel trajectories obtained from Goddard. The rates of ozone depletion along trajectories with different meteorological histories are presently being systematically evaluated to identify the principal relationships between ozone loss and aerosol state. Under this project, we formulated a detailed quantitative model that predicts the multicomponent composition of sulfate aerosols under stratospheric conditions, including sulfuric, nitric, hydrochloric, hydrofluoric and hydrobromic acids. This work defined for the first time the behavior of liquid ternary-system type-1b PSCS. The model also allows the compositions and reactivities of sulfate aerosols to be calculated over the entire range of environmental conditions encountered in the stratosphere (and has been incorporated into a trajectory/microphysics model-see above). Important conclusions that derived from this work over the last few years include the following: the HNO3 content of liquid-state aerosols dominate PSCs below about 195 K; the freezing of nitric acid ice from sulfate aerosol solutions is likely to occur within a few degrees K of the water vapor frost point; the uptake and reactions of HCl in liquid aerosols is a critical component of PSC heterogeneous chemistry. In a related application of this work, the inefficiency of chlorine injection into the stratosphere during major volcanic eruptions was explained on the basis of nucleation of sulfuric acid aerosols in rising volcanic plumes leading to the formation of supercooled water droplets on these aerosols, which efficiently scavenges HCl via precipitation.

Turco, Richard P.↗

Development and Experimental Evaluation of Passive Fuel Cell Thermal Control

To provide uniform cooling for a fuel cell stack, a cooling plate concept was evaluated. This concept utilized thin cooling plates to extract heat from the interior of a fuel cell stack and move this heat to a cooling manifold where it can be transferred to an external cooling fluid. The advantages of this cooling approach include a reduced number of ancillary components and the ability to directly utilize an external cooling fluid loop for cooling the fuel cell stack. A number of different types of cooling plates and manifolds were developed. The cooling plates consisted of two main types; a plate based on thermopyrolytic graphite (TPG) and a planar (or flat plate) heat pipe. The plates, along with solid metal control samples, were tested for both thermal and electrical conductivity. To transfer heat from the cooling plates to the cooling fluid, a number of manifold designs utilizing various materials were devised, constructed, and tested. A key aspect of the manifold was that it had to be electrically nonconductive so it would not short out the fuel cell stack during operation. Different manifold and cooling plate configurations were tested in a vacuum chamber to minimize convective heat losses. Cooling plates were placed in the grooves within the manifolds and heated with surface-mounted electric pad heaters. The plate temperature and its thermal distribution were recorded for all tested combinations of manifold cooling flow rates and heater power loads. This testing simulated the performance of the cooling plates and manifold within an operational fuel cell stack. Different types of control valves and control schemes were tested and evaluated based on their ability to maintain a constant temperature of the cooling plates. The control valves regulated the cooling fluid flow through the manifold, thereby controlling the heat flow to the cooling fluid. Through this work, a cooling plate and manifold system was developed that could maintain the cooling plates within a minimal temperature band with negligible thermal gradients over power profiles that would be experienced within an operating fuel cell stack.

Fuel Cells↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Suppression of toroidal Alfvén eigenmodes by the electron cyclotron current drive in KSTAR plasmas

Advanced operation scenarios such as high poloidal beta ( β P ) or high q min are promising concepts to achieve the steady-state high-performance fusion plasmas. However, those scenarios are prone to substantial Alfvénic activity, causing fast-ion transport and losses. Recent experiments with the advanced operation scenario on KSTAR tokamak have shown that the electron cyclotron current drive (ECCD) is able to mitigate and suppress the beam-ion driven toroidal Alfvén eigenmodes (TAEs) for over several tens of global energy confinement time. Co-current directional intermediate off-axis ECCD lowers the central safety factor slightly and tilts the central q -profile shape so that the continuum damping in the core region increases. Besides, the rise of central plasma pressure and increased thermal-ion Landau damping contribute to TAE stabilization. While the TAEs are suppressed, neutron emission rate and total stored energy increase by approximately 45% and 25%, respectively. Fast-ion transport estimated by TRANSP calculations approaches the classical level during the TAE suppression period. Substantial reduction in fast-ion loss and neutron deficit is also observed. Subsequently, enhancement of fast-ion confinement by suppressing the TAEs leads to an increase of non-inductive current fraction and will benefit the sustainment of the long-pulse high-performance discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗