Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “oriented attachment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

Circular orientation fluorescence emitter imaging (COFEI) of rotational motion of motor proteins

Single-molecule fluorescence polarization technique has been utilized to detect structural changes in biomolecules and intermolecular interactions. Here we developed a single-molecule fluorescence polarization measurement system, named circular orientation fluorescence emitter imaging (COFEI), in which a ring pattern of an acquired fluorescent image (COFEI image) represents an orientation of a polarization and a polarization factor. Rotation and pattern change of the COFEI image allow us to find changes in the polarization by eye and further values of the parameters of a polarization are determined by simple image analysis with high accuracy. We validated its potential applications of COFEI by three assays: 1) Detection of stepwise rotation of F{sub 1}-ATPase via single quantum nanorod attached to the rotary shaft γ; 2) Visualization of binding of fluorescent ATP analog to the catalytic subunit in F{sub 1}-ATPase; and 3) Association and dissociation of one head of dimeric kinesin-1 on the microtubule during its processive movement through single bifunctional fluorescent probes attached to the head. These results indicate that the COFEI provides us the advantages of the user-friendly measurement system and persuasive data presentations.

60 APPLIED LIFE SCIENCES↗

Internal strain gradients quantified in bone under load using high-energy X-ray scattering.

High-energy synchrotron X-ray scattering (>60 keV) allows noninvasive quantification of internal strains within bone. In this proof-of-principle study, wide angle X-ray scattering maps internal strain vs position in cortical bone (murine tibia, bovine femur) under compression, specifically using the response of the mineral phase of carbonated hydroxyapatite. The technique relies on the response of the carbonated hydroxyapatite unit cells and their Debye cones (from nanocrystals correctly oriented for diffraction) to applied stress. Unstressed, the Debye cones produce circular rings on the two-dimensional X-ray detector while applied stress deforms the rings to ellipses centered on the transmitted beam. Ring ellipticity is then converted to strain via standard methods. Strain is measured repeatedly, at each specimen location for each applied stress. Experimental strains from wide angle X-ray scattering and an attached strain gage show bending of the rat tibia and agree qualitatively with results of a simplified finite element model. At their greatest, the apatite-derived strains approach 2500 {micro}{var_epsilon} on one side of the tibia and are near zero on the other. Strains maps around a hole in the femoral bone block demonstrate the effect of the stress concentrator as loading increased and agree qualitatively with the finite element model. Experimentally, residual strains of approximately 2000 {micro}{var_epsilon} are present initially, and strain rises to approximately 4500 {micro}{var_epsilon} at 95 MPa applied stress (about 1000 {micro}{var_epsilon} above the strain in the surrounding material). The experimental data suggest uneven loading which is reproduced qualitatively with finite element modeling.

59 BASIC BIOLOGICAL SCIENCES↗

Reverse Launch Abort System Parachute Architecture Trade Study

This study investigated a potential Launch Abort System (LAS) Concept of Operations and abort parachute architecture. The purpose of the study was to look at the concept of jettisoning the LAS tower forward (Reverse LAS or RLAS) into the free-stream flow rather than after reorienting to a heatshield forward orientation. A hypothesized benefit was that due to the compressed timeline the dynamic pressure at main line stretch would be substantially less. This would enable the entry parachutes to be designed and sized based on entry loading conditions rather than the current stressing case of a Pad Abort. Ultimately, concerns about the highly dynamic reorientation of the CM via parachutes, and the additional requirement of a triple bridle attachment for the RLAS parachute system, overshadowed the potential benefits and ended this effort.

Litton, Daniel K.↗

Metal Patch Antenna

Disclosed herein is a patch antenna comprises a planar conductive patch attached to a ground plane by a support member, and a probe connector in electrical communication with the conductive patch arranged to conduct electromagnetic energy to or from the conductive patch, wherein the conductive patch is disposed essentially parallel to the ground plane and is separated from the ground plane by a spacing distance; wherein the support member comprises a plurality of sides disposed about a central axis oriented perpendicular to the conductive patch and the ground plane; wherein the conductive patch is solely supported above the ground plane by the support member; and wherein the support member provides electrical communication between the planer conductive patch and the ground plane.

Chamberlain, Neil F.↗

Triboionization: a Novel Ionization Method by Peeling of Cohesive Substances for Mass Spectrometry

A novel ionization/sampling method termed triboionization was developed. Triboionization is an ionization method that only uses cohesive substances, such as food wrap or sticky tape, and does not require an electrode, electric power supply, heat source, light source, radiation, or gas, unlike most other conventional ambient ionization methods. In this study, the sample compound attached to adhesive tape or plastic wrap was quickly peeled off at a distance of approximately 2 cm from the atmospheric interface of a mass spectrometer. All of the five types of food wrap and 13 types of adhesive tape tested successfully ionized caffeine. Nine out of ten model compounds were detected as the corresponding molecular ions in the positive or negative mode by this ionizing contrivance using an oriented polypropylene adhesive tape. The detected molecular ions were typically protonated molecules or sodium adducts in the positive mode or deprotonated molecules in the negative mode. The elemental compositions of the observed ions were confirmed within 5 ppm by high-resolution mass spectrometry. The triboionization phenomenon was considered to depend on physical and electronic events caused by peeling off a cohesive substance. Triboionization is able to provide a compact ion source using only mechanical mechanisms. Additionally, triboionization allows sticky tape to be used as a convenient sampling device for surface analysis. .

74 ATOMIC AND MOLECULAR PHYSICS↗

High resolution Fourier interferometer-spectrophotopolarimeter

A high-resolution Fourier interferometer-spectrophotopolarimeter is provided using a single linear polarizer-analyzer the transmission axis azimuth of which is positioned successively in the three orientations of 0 deg, 45 deg, and 90 deg, in front of a detector; four flat mirrors, three of which are switchable to either of two positions to direct an incoming beam from an interferometer to the polarizer-analyzer around a sample cell transmitted through a medium in a cell and reflected by medium in the cell; and four fixed focussing lenses, all located in a sample chamber attached at the exit side of the interferometer. This arrangement can provide the distribution of energy and complete polarization state across the spectrum of the reference light entering from the interferometer; the same light after a fixed-angle reflection from the sample cell containing a medium to be analyzed; and the same light after direct transmission through the same sample cell, with the spectral resolution provided by the interferometer.

Fymat, A. L.↗

Vanguard Satellite Spin-Reduction Mechanism

The Cloud Cover Satellite flown in Vanguard vehicles SLV-3 and SLV-4 required a spin rate of 55 r.p.m. when entering orbit. Since the third-stage rocket was spin-stabilized in flight, and because other considerations required that the satellite remain attached long enough to acquire more than the desired 55 r.p.m., a satellite spin-reduction mechanism was developed. Although the mechanisms functioned properly in both flights, the desired spin rate was not achieved owing to uncontrollable flight effects. These effects make the prediction of satellite spin rates after a long pre-separation coasting period extremely difficult. To meet future requirements a control system is needed which can orient a payload according to a predetermined scheme and maintain that orientation for the desired period.

Baumann, Robert C.↗

SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system safer than before.

60 APPLIED LIFE SCIENCES↗

Notched fatigue of single crystal PWA 1480 at turbine attachment temperatures

The focus is on the lower temperature, uncoated and notched features of gas turbine blades. Constitutive and fatigue life prediction models applicable to these regions are being developed. Fatigue results are presented which were obtained thus far. Fatigue tests are being conducted on PWA 1480 single crystal material using smooth strain controlled specimens and three different notched specimens. Isothermal fatigue tests were conducted at 1200, 1400, and 1600 F. The bulk of the tests were conducted at 1200 F. The strain controlled tests were conducted at 0.4 percent per second strain rate and the notched tests were cycled at 1.0 cycle per second. A clear orientation dependence is observed in the smooth strain controlled fatigue results. The fatigue lifes of the thin, mild notched specimens agree fairly well with this smooth data when elastic stress range is used as a correlating parameter. Finite element analyses were used to calculate notch stresses. Fatigue testing will continue to further explore the trends observed thus far. Constitutive and life prediction models are being developed.

Meyer, T. G.↗

Binding and Inactivation Mechanism of a Humanized Fatty Acid Amide Hydrolase by [alpha]-Ketoheterocycle Inhibitors Revealed from Cocrystal Structures

The cocrystal X-ray structures of two isomeric {alpha}-ketooxazole inhibitors (1 (OL-135) and 2) bound to fatty acid amide hydrolase (FAAH), a key enzymatic regulator of endocannabinoid signaling, are disclosed. The active site catalytic Ser241 is covalently bound to the inhibitors electrophilic carbonyl groups, providing the first structures of FAAH bound to an inhibitor as a deprotonated hemiketal mimicking the enzymatic tetrahedral intermediate. The work also offers a detailed view of the oxyanion hole and an exceptional 'in-action' depiction of the unusual Ser-Ser-Lys catalytic triad. These structures capture the first picture of inhibitors that span the active site into the cytosolic port providing new insights that help to explain FAAH's interaction with substrate leaving groups and their role in modulating inhibitor potency and selectivity. The role for the activating central heterocycle is clearly defined and distinguished from that observed in prior applications with serine proteases, reconciling the large electronic effect of attached substituents found unique to this class of inhibitors with FAAH. Additional striking active site flexibility is seen upon binding of the inhibitors, providing insights into the existence of a now well-defined membrane access channel with the disappearance of a spatially independent portion of the acyl chain-binding pocket. Finally, comparison of the structures of OL-135 (1) and its isomer 2 indicates that they bind identically to FAAH, albeit with reversed orientations of the central activating heterocycle, revealing that the terminal 2-pyridyl substituent and the acyl chain phenyl group provide key anchoring interactions and confirming the distinguishing role of the activating oxazole.

59 BASIC BIOLOGICAL SCIENCES↗

The Dynamics of 1, 3 diphenylpropane Tethered to the Interior Pore Surfaces of MCM-41

The diffusive motions of covalently tethered 1, 3 diphenylpropane (DPP) via a silyl-aryl-ether linkage in the mesopores of MCM-41 were studied by quasielastic neutron scattering. The geometric effect of pore radius was investigated with samples having pores that ranged from 1.6 to 3.0 nm in diameter and highest achievable DPP grafting density. The effect of molecular crowding was investigated in 3.0 nm diameter pores for surface coverage ranging from 0.60 to 1.61 DPP/nm2. Temperature dependence was determined for large pore diameter samples from 240 K to 370 K. As the DPP molecules remain attached over this entire temperature range, data were analyzed in terms of a model of localized diffusion inside a sphere. Only the motions of the DPP hydrogen atoms were considered because of the high sensitivity of neutron scattering to the presence of hydrogen. As atoms far from the attachment point have a greater range of motion than those nearer the tether, the radius of the sphere limiting the motion of individual hydrogen atoms was allowed to increase based on the atom s distance from the tether point. Both smaller pore diameters and higher DPP surface coverage resulted in larger amplitude motion while the diffusion coefficient was greatest in the largest pores at highest surface coverage. These observations support a model where the DPP molecules prefer an orientation allowing close proximity to the MCM-41 pore surface and are forced into the pore interior by either the steric effect of small pore diameter or by increased competition for surface area at high molecule surface coverage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Surface Sampling Techniques for the Canister Deposition Field Demonstration (FY22 Update)

This report describes the proposed surface sampling techniques and plan for the multi-year Canister Deposition Field Demonstration (CDFD). The CDFD is primarily a dust deposition test that will use three commercial 32PTH2 NUHOMS welded stainless steel storage canisters in Advanced Horizontal Storage Modules, with planned exposure testing for up to 10 years at an operating ISFSI site. One canister will be left at ambient condition, unheated; the other two will have heaters to achieve canister surface temperatures that match, to the degree possible, spent nuclear fuel (SNF) loaded canisters with heat loads of 10 kW and 40 kW. Surface sampling campaigns for dust analysis will take place on a yearly or bi-yearly basis. The goal of the planned dust sampling and analysis is to determine important environmental parameters that impact the potential occurrence of stress corrosion cracking on SNF dry storage canisters. Specifically, measured dust deposition rates and deposited particle sizes will improve parameterization of dust deposition models employed to predict the potential occurrence and timing of stress corrosion cracks on the stainless steel SNF canisters. The size, morphology, and composition of the deposited dust and salt particles will be quantified, as well as the soluble salt load per unit area and the rate of deposition, as a function of canister surface temperature, location, time, and orientation. Previously, a preliminary sampling plan was developed, identifying possible sampling locations on the canister surfaces and sampling intervals; possible sampling methods were also described. Further development of the sampling plan has commenced through three different tasks. First, canister surface roughness, a potentially important parameter for air flow and dust deposition, was characterized at several locations on one of the test canisters. Second, corrosion testing to evaluate the potential lifetime and aging of thermocouple wires, spot welds, and attachments was initiated. Third, hand sampling protocols were developed, and initial testing was carried out. The results of those efforts are presented in this report. The information obtained from the CDFD will be critical for ongoing efforts to develop a detailed understanding of the potential for stress corrosion cracking of SNF dry storage canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring the Mineral Composition, Structure, and Function of a Freshwater Bivalve Adhesive

Abstract Etheria elliptica is a freshwater oyster that produces an adhesive that hardens underwater, allowing them to attach to other oysters, rocks, wood, and other natural substrates, producing complex oyster bed communities. Despite the importance of the adhesive in oyster bed formation, little is known about its chemical composition, structure, or mechanical properties. Through a combination of scanning electron microscopy (SEM), x‐ray photoemission electron microscopy (X‐PEEM), infrared (IR) spectroscopy, microhardness testing, and nanoindentation, it is found that the oyster adhesive consists entirely of aragonite nanoparticles that clump together into crystallites of varied shape, size, and orientation. The crystallite clumping density varies from the exterior of the adhesive to the interior, with the adhesive closest to the prismatic layer generally being denser. With this variation in density comes a variation in material properties with the exterior adhesive layer being softer and more flexible and the interior adhesive layer being harder and less elastic, or more similar to the prismatic and nacre shell structures produced by the E. elliptica . The resultant material exhibits varied materials properties, despite similar mineral composition.

Chemistry↗

Optimization of space structures

Computational methods for the design of structures for specified transient response, truss beam units with specified attached vibration absorbers, and laminates for structural components of large space structures are examined. Equations for the measurement of structural stiffness that are maximized for a specific total mass and that will reduce the structural weight are presented. A model for a cantilevered space truss beam of a specific mass and with a specified tip vibration absorber is explained. Design criteria of the laminates include minimizing the weight as well as frequency, buckling, and global stiffness constraints. Other variables include orientation of the lamina and the thickness of each layer.

Reiss, R.↗

Gravity-Independent Mobility and Drilling on Natural Rock using Microspines

To grip rocks on the surfaces of asteroids and comets, and to grip the cliff faces and lava tubes of Mars, a 250 mm diameter omni-directional anchor is presented that utilizes a hierarchical array of claws with suspension flexures, called microspines, to create fast, strong attachment. Prototypes have been demonstrated on vesicular basalt and a'a lava rock supporting forces in all directions away from the rock. Each anchor can support >160 N tangent, >150 N at 45?, and >180 N normal to the surface of the rock. A two-actuator selectively- compliant ankle interfaces these anchors to the Lemur IIB robot for climbing trials. A rotary percussive drill was also integrated into the anchor, demonstrating self-contained rock coring regardless of gravitational orientation. As a harder- than-zero-g proof of concept, 20mm diameter boreholes were drilled 83 mm deep in vesicular basalt samples, retaining a 12 mm diameter rock core in 3-6 pieces while in an inverted configuration, literally drilling into the ceiling.

climbing mechanisms↗

Backbone Stitching in Bottlebrush Copolymer Mesodomains and the Impact of Side Chain Crystallization

We synthesized bottlebrush statistical copolymers (BSCPs) having poly­(ethylene oxide) (PEO) and poly­(dimethylsiloxane) (PDMS) side chains attached to a polynorbornene backbone. Small-angle X-ray scattering analysis showed that for densely grafted BSCPs, the scattering length density gradually transitions between the PEO and PDMS domains. For loosely grafted BSCPs, the polymer backbone formed a distinct mesodomain, with a lower electron and mass density than both the PEO and PDMS domains. The bottlebrush backbone essentially “stitches” the PEO and PDMS side chains, looping back and forth from the PEO to PDMS domains with the backbone segments oriented normal to the domain interfaces. Self-consistent field theory (SCFT) calculations validated the stitching of the backbone driven by the microphase separation of PEO and PDMS, along with a strong segmental order of the side chains in the melt. The reduced birefringence upon PEO crystallization suggests the disruption of the strong segmental order by the crystallization. Both the static intrinsic and the form birefringences of the BSCPs decreased upon PEO crystallization. Solid-state NMR confirmed the rigidity of PEO crystallites and the bottlebrush backbone. Self-assembly of BSCPs containing polyhedral oligomeric silsesquioxane (POSS) pendent groups was also evaluated by X-ray scattering, showing the formation of lamellar microdomains that inhibited POSS crystallization.

Hu, Mingqiu↗

Influence of LC Content on the Phase Structures of Side-Chain Liquid

We report the phase structures of a series of poly(styrene-block-{l_brace}3'-[4-(4-n-dodecyloxybenzoyloxy)benzoyloxy]-4-(12-methacryloyloxydodecyloxy)benzoyloxybiphenyl{r_brace}) (PS-b-PMAC) side-chain liquid crystalline block copolymers (SC LCBCP). The SC liquid crystalline polymer was formed by side attaching a bent-core mesogen to the polymer backbone using a 12-carbon spacer. The phase structure of the high and low fPMAC samples were investigated using differential scanning calorimetry, small-angle and wide-angle X-ray scattering, and transmission electron microscopy techniques. The PS coil block and PMAC LC block phase separate into a lamellar morphology in all of the samples investigated (volume fraction of PMAC fPMAC 0.31-0.65). However, both the LC phase and the orientation of the hierarchical structure under mechanical shear showed strong dependence on the LC content. Samples having a high fPMAC (0.5-0.65) showed a SmC2 LC phase (Smectic C denotes the LC molecules are tilted with respect to the layer normal, and 2 represents a bilayered structure), similar to that observed in PMAC homopolymers. Upon mechanical shear, these smectic layers oriented parallel to the shear plane and the BCP lamellae oriented perpendicular to the shear plane with the layer normal parallel to the vorticity direction. In samples having a lower fPMAC, the BCP lamellae laid parallel to the shear plane and the LC phase structure in these samples was columnar rectangular. A detailed structural and morphological study will be reported.

36 MATERIALS SCIENCE↗