Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

All-optical control of charge transfer and interlayer excitons in transition metal dichalcogenide heterostructures

An all-optical approach to control interlayer charge transfer and interlayer exciton dynamics is demonstrated using transition metal dichalcogenide heterostructures of MoSe 2 /MoS 2 and MoSe 2 /WS 2 as examples. In the three-pulse pump-probe experiments, a control pulse injects photocarriers and produces an electric field due to the interlayer charge separation. A pump pulse excites new carriers and their dynamics under the influence of the control-injected carriers and field is time-resolved by measuring differential reflectance of a third probe pulse. In MoSe 2 /MoS 2 , the interlayer electron transfer time from MoSe 2 to MoS 2 decreases with increasing the control-injected carrier density and electric field. The dipole moment of the interlayer excitons is reduced by the control pulse, which can be utilized for ultrafast and all-optical control of interlayer excitons. The recombination of the interlayer excitons is enhanced by the control pulse, which increases the spatial overlap of the electron and hole wave functions. The effect of the control pulse on the interlayer excitons is confirmed in the MoSe 2 /WS 2 heterostructure, although its effect on the electron transfer time is not resolvable. Furthermore, these results reveal useful information to understand and control interlayer charge transfer dynamics and provide tools for ultrafast manipulation of electrons in van der Waals heterostructures.

36 MATERIALS SCIENCE↗

A 40 Gbps Optical Transceiver for Particle Physics Experiments

We present the design and the test results of a quad-channel optical transceiver module (QTRx) possibly for future particle physics experiments. The transmitters of QTRx, each at 10 Gbps, are based on a Quad-channel VCSEL Diode array Driver (QLDD) and 1 x 4 VCSEL array. The receivers of QTRx, with data rates of 2.56 Gbps or 10 Gbps per channel, are based on a Quad-channel Trans-Impedance and limiting Amplifier (QTIA) and 1 x 4 photodiode array of GaAs or InGaAs. QTRx is 20 mm x 10 mm x 5 mm and couples to an MT fiber connector. Test results indicate that QTRx achieves the design goals with a power consumption of 124 mW per transmitter channel at 10 Gbps and 120 mW at 2.56 Gbps for the receiver channel with an on-chip charge pump. The sensitivities of QTIA are -17 dBm at 2.56 Gbps and -8 dBm at 10 Gbps, respectively. Further improvements with a gold-finger interface and a more compact optical lens are being designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Symmetry-protected electronic metastability in an optically driven cuprate ladder

Optically excited quantum materials exhibit non-equilibrium states with remarkable emergent properties, but these phenomena are usually transient, decaying on picosecond timescales and limiting practical applications. Advancing the design and control of non-equilibrium phases requires the development of targeted strategies to achieve long-lived, metastable phases. Here, in this study, we report the discovery of symmetry-protected electronic metastability in the model cuprate ladder Sr 14 Cu 24 O 41 . Using femtosecond resonant X-ray scattering and spectroscopy, we show that this metastability is driven by a transfer of holes from chain-like charge reservoirs into the ladders. This ultrafast charge redistribution arises from the optical dressing and activation of a hopping pathway that is forbidden by symmetry at equilibrium. Relaxation back to the ground state is, hence, suppressed after the pump coherence dissipates. Our findings highlight how dressing materials with electromagnetic fields can dynamically activate terms in the electronic Hamiltonian, and provide a rational design strategy for non-equilibrium phases of matter.

36 MATERIALS SCIENCE↗

A new capability for investigating the structure and dynamics of liquids at high pressures

Water and aqueous solutions are critical to many areas of science and technology. As a result, tremendous effort has been devoted to understanding them in detail. Despite over a century of research, fundamental questions about water and aqueous solutions remain unanswered. However, an intriguing possibility – that liquid water can exist in two thermodynamically distinct states – has emerged as the most likely explanation. The problem is that experimental confirmation of this hypothesis requires experiments on water at high pressures and low temperatures, conditions in which liquid water only exists briefly before turning into crystalline ice. This project investigated the feasibility of developing a new capability for study water and aqueous solutions under these challenging conditions. The physical constraints, such as the timescales for crystallization and thermal diffusion in supercooled water, were evaluated along with their impact on the design criteria for the instrument. Several basic design options were considered that could meet the technical requirements. The options were also evaluated with respect to their use of commercially available equipment versus the need for custom designs or in-house development. The project identified two viable options to pursue. The first option would use a high-pressure syringe pump in conjunction with fused silica (or sapphire) capillaries. The second option would use a diamond anvil cell. These options can both be used with optical spectroscopies, such as Raman or Infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective Detection in Impulsive Low-Frequency Raman Imaging Using Shaped Probe Pulses

Impulsive stimulated Raman scattering (ISRS) using a single short femtosecond pump pulse to excite molecular vibrations offers an elegant pump-probe approach to perform vibrational imaging below 200 cm –1 . One shortcoming of ISRS is its inability to offer vibrational selectivity as all the vibrational bonds whose frequencies lie within the short pump-pulse bandwidth are excited. To date, several coherent control techniques have been explored to address this issue and selectively excite a specific molecular vibration by shaping the pump pulse. There has not been any systematic work that reports an analogous shaping of the probe pulse to implement preferential detection. In this work, we focus on vibrational imaging and report vibrational selective detection by shaping the probe pulse in time. Here, we demonstrate numerically and experimentally two pulse-shaping strategies with one functioning as a vibrational notch filter and the other functioning as a vibrational low-pass filter. This enables fast (25 μs/pixel) and selective hyperspectral imaging in the low-frequency regime (< 200 cm –1 ).

74 ATOMIC AND MOLECULAR PHYSICS↗

Gallium-doped zinc oxide: nonlinear reflection and transmission measurements and modeling in the ENZ region

Abstract Strong nonlinear materials have been sought after for decades for applications in telecommunications, sensing, and quantum optics. Gallium-doped zinc oxide is a II–VI transparent conducting oxide that shows promising nonlinearities similar to indium tin oxide and aluminum-doped zinc oxide for the telecommunications band. Here we explore its nonlinearities in the epsilon near zero (ENZ) region and show n 2,eff values on the order of 4.5 × 10 −3 cm 2 GW −1 for IR pumping on 200–300 nm thin films. Measuring nonlinear changes in transmission and reflection with a white light source probe in the near-IR while exciting in the near-IR provides data in both time and wavelength. Three films varying in thickness, optical loss, and ENZ crossover wavelength are numerically modeled and compared to experimental data showing agreement for both dispersion and temporal relaxation. In addition, we discuss optimal excitation and probing wavelengths occur around ENZ for thick films but are red-shifted for thin films where our model provides an additional degree of freedom to explore. Obtaining accurate nonlinear measurements is a difficult and time-consuming task where our method in this paper provides experimental and modeled data to the community for an ENZ material of interest.

Ball, Adam (ORCID:0000000318167813)↗

Effect of elastic anisotropy on thermally induced distortions of a laser beam in single cubic syngony crystals with radial cooling. Part I

We have studied thermally induced distortions of a beam in single cubic syngony crystals of all symmetry groups with an anisotropic elastic stiffness tensor. The arithmetic mean and the difference between the thermally induced phase incursions of eigenpolarisations, as well as the angle of incidence of these polarisations, are calculated for a long rod and a thin disk with radial cooling under uniform volume pumping of the active element. The position of the specific crystal orientations unrelated to its symmetry elements is investigated. The effective values of the thermo-optical constant Q in two specific orientations, as well as the thermo-optical constant P in an arbitrary orientation, are found. (invited paper)

36 MATERIALS SCIENCE↗

Dispersion-engineered χ(2) nanophotonics: a flexible tool for nonclassical light

Abstract This article reviews recent progress in quasi-phasematched χ ( 2 ) nonlinear nanophotonics, with a particular focus on dispersion-engineered nonlinear interactions. Throughout this article, we establish design rules for the bandwidth and interaction lengths of various nonlinear processes, and provide examples for how these processes can be engineered in nanophotonic devices. In particular, we apply these rules towards the design of sources of non-classical light and show that dispersion-engineered devices can outperform their conventional counterparts. Examples include ultra-broadband optical parametric amplification as a resource for measurement-based quantum computation, dispersion-engineered spontaneous parametric downconversion as a source of separable biphotons, and synchronously pumped nonlinear resonators as a potential route towards single-photon nonlinearities.

Jankowski, Marc (ORCID:0000000318457415)↗

Three-dimensional reconstruction of THz near-fields from a LiNbO3 optical rectification source

Terahertz (THz) generation by optical rectification in LiNbO3 (LN) is a widely used technique for generating intense THz radiation. The spatiotemporal characterization of THz pulses from these sources is currently limited to far-field methods. While simulations of tilted pulse front THz generation have been published, little work has been done to measure the near-field properties of the THz source. A better understanding of the THz near-field properties will improve optimization of THz generation efficiency, transport, and coupling. We demonstrate a technique for quantitative spatiotemporal characterization of single-cycle strong-field THz pulses with 2-D near-field electro-optic imaging. We have reconstructed the full temporal 3D THz near-field and shown how the phase front can be tailored by controlling the incident pump pulse.

Gabriel, Annika↗

Long interior carrier lifetime in selective-area InAs nanowires on silicon

Catalyst-free, position-controlled indium arsenide (InAs) nanowires (NWs) of variable diameters were grown on Si (111) by selective-area epitaxy (SAE). Ultrafast pump-probe spectroscopy was conducted, from which carrier recombination mechanisms on the NW surface and interior were resolved and characterized. NWs grown using SAE demonstrated high optical quality, showing minority carrier lifetimes more than two-fold longer than that of the randomly-positioned (RP) NWs. The extracted SAE-InAs NW interior recombination lifetime was found to be as long as 7.2 ns , 13X longer than previous measurements on RP-NWs; and the surface recombination velocity 4154 cm · s - 1 . Transmission electron microscopy revealed a high density of stacking defects within the NWs, suggesting that interior recombination lifetime can be further increased by improving NW interior crystalline quality.

36 MATERIALS SCIENCE↗

CMOS photonic integrated source of broadband polarization-entangled photons

We showcase a fully on-chip CMOS-fabricated silicon photonic integrated circuit employing a bidirectionally pumped microring and polarization splitter-rotators tailored for the generation of broadband (>9 THz), high-fidelity (90–98%) polarization-entangled photons. Spanning the optical C+L-band and producing over 116 frequency-bin pairs on a 38.4-GHz-spaced grid, this source is ideal for flex-grid wavelength-multiplexed entanglement distribution in multiuser networks.

42 ENGINEERING↗

Robust In-Situ Strain Measurements to Monitor CO 2 Storage

The goal of this project was to develop and demonstrate robust instrumentation to monitor the in-situ strain tensor in order to improve the reliability and security of CO 2 storage in geologic formations. We met the original goals of the project and the major overarching accomplishment is the advancement of strain tensor monitoring from an intriguing concept to a commercially available technology with a solid foundation of novel instruments supported by theoretical analyses and validation experiments. The main accomplishments of the project are summarized below. We designed, built and evaluated nine new optical fiber strainmeters and tiltmeters using Michelson interferometers to measure deformation with ultra-high resolution at both shallow and deep point locations in the subsurface. These are the robust strainmeters that motivated the title of the project. We designed, built and evaluated a novel method of measuring distributed strain in optical fibers with nanostrain resolution, and cm-scale location, and sampling into the seismic band. The new method is called Coherence-length-gated Microwave Photonics Interfereometry (CMPI). CMPI technology has advantages over existing commercial DAS and DSS methods. We developed and demonstrated capabilities to deploy instruments in the field and used them to measure strain caused by ambient signals like barometric pressure and tides, as well as induced signals like surface loading and pore pressure changes from pumping tests. We deployed a working strainmeter at 1,700 ft depth, slightly above an active reservoir. This is to our knowledge the greatest depth a strainmeter has been deployed and the techniques we used can readily be extended to greater depths. Optical fiber borehole tensor strainmeter techology was advanced from a TRL 4 at the start, to a TRL of 7 at the conclusion of the project. The project included advances in simulations and theoretical analyses. We developed and demonstrated a computational workflow that uses machine learning to reduce the computational requirements and make it practical to use Bayesian inversion to solve large numerical poroelastic analyses needed to interpret strain tensor field data. We evaluated the strain tensor fields and time series that would be caused by leaks of CO 2 or other fluids from reservoirs. These simulations demonstrated that signals from leaks could be measured with instruments developed for the project, opening a potentially new method for ensuring storage security. We showed that strains in caprock can be used to estimate pressure in a reservoir. This avoids the need to drill monitoring wells into the reservoir, and it expands the capabilities of monitoring in the caprock. The project includes a derivation and application of a novel analytical solution to the strains in the vicinity of a pressurized poroelastic inclusion. This solution explains field data measured during injeciton tests at the North Avant Field, and it will simplify future interpretation of strain tensor data. The project included a broad range of experiments, and of the most significant is the characterization of the strain tensor at an array three strainmeters during six injection tests at the North Avant Field, Oklahoma. This demonstrated repeatability of the strain signal measured by the new instruments developed for the project, and it showed similarities between the strain signal at shallow depths and pressure in the underlying reservoir. We also demonstrated that useful strain data can be measured at reservoir depths. This confirms that strain tensor data can be measured throughout the caprock over a reservoir. The project demonstrated the feasibility of using the strain tensor and distributed strain measured in caprock during a variety of different well tests where the pumping rate was constant, sinusoidal and positive, or a periodic square wave with zero net rate. This further strengthens the validity of using strain data to characterize reservoirs and aquifers. We also demonstrated that strain caused be fluctuations of air pressure and water pressure in the vadose zone can be measured and interpreted, suggesting that high resolution distributed strain measurements hold promise for monitoring the vadose zone. The project partially supported nine graduate students in the Environmental Engineering, Hydrogeology, Electrical Engineering programs at Clemson University. The research was described in nine journal papers, 23 talks and conference abstracts. Additional journal papers are in preparation. A new company called Tensora was started to provide strainmeter technology for commercial applications.

01 COAL, LIGNITE, AND PEAT↗

Passively pumped, polycrystalline ceramic high and ultra-high vacuum chambers

A sealed, passively pumped, polycrystalline ceramic vacuum chamber and method for fabricating the chamber are disclosed. The body of the vacuum chamber is made from a polycrystalline ceramic, for example, alumina. The vacuum chamber includes one or more windows made from a transparent ceramic, for example, sapphire, to accommodate optical access, while remaining amorphous-glass free to minimize or eliminate helium permeation. The vacuum chamber components are joined via laser welding or furnace brazing and the completed chamber is bakeable at temperatures up to 400° C. The vacuum chamber can operate at high or ultra-high vacuum pressures for an extended period through the use of one or more getter-based pumps. The vacuum chamber may include one or more atomic sources depending upon the application.

Walker, Charles A.↗

Time-Evolving Chirality Loss in Molecular Photodissociation Monitored by X-ray Circular Dichroism Spectroscopy

In this work, the ultrafast photoinduced chirality loss of 2-iodobutane is studied theoretically by time- and frequency-resolved X-ray circular dichroism (TRXCD) spectroscopy. Following an optical excitation, the iodine atom dissociates from the chiral center, which we capture by quantum non-adiabatic molecular dynamics simulations. At variable time delays after the pump, the resonant X-ray pulse selectively probes the iodine and carbon atom involved in the chiral dissociation through a selected core-to-valence transition. The TRXCD signal at the iodine L 1 edge accurately captures the timing of C–I photodissociation and thereby chirality loss, c.a 70 fs. The strong electric dipole–electric quadrupole (ED–EQ) response makes this signal particularly sensitive to vibronic coherence at the high X-ray regime. At the carbon K-edges, the signals monitor the molecular chirality of the 2-butyl radical photoproduct and the spin state of the iodine atom. The ED–EQ response is masked under the strong electric dipole-magnetic dipole response, making this signal intuitive for the electronic population. The evolution of the core electronic states and its chiral sensitivity is discussed. Overall, the element-specific TRXCD signal provides a detailed picture of molecular dynamics and offers a unique sensitive window into the time-dependent chirality of molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast signatures of spin and orbital order in antiferromagnetic α-Sr2CrO4

Abstract The antiferromagnetic Mott insulator α -Sr 2 CrO 4 possesses multiple spin and orbital ordered phases, but their unique interplay is still relatively unexplored. Here, we used femtosecond optical spectroscopy to study ultrafast spin and orbital ordering dynamics in α -Sr 2 CrO 4 through their non-equilibrium response to photoexcitation. By varying the pump photon energy, we selectively drove inter-site spin hopping between neighboring Cr t 2 g orbitals and charge transfer-type transitions between oxygen 2 p and Cr e g orbitals. The resulting transient reflectivity dynamics revealed temperature-dependent anomalies across the Néel temperature for spin ordering as well as the transition temperatures linked to different types of orbital order. Our results reveal distinct relaxation timescales for spin and orbital orders in α -Sr 2 CrO 4 and provide experimental evidence for the phase transition at T O , possibly related to antiferro-type orbital ordering.

36 MATERIALS SCIENCE↗

Decreasing the amplitude of macroscopic quantum fluctuations in the case of transient SRS

It is shown experimentally that, under the conditions of transient stimulated Raman scattering, pumping by two successive orthogonally polarised laser pulses makes it possible to reduce the amplitude of macroscopic quantum energy fluctuations of a Stokes pulse by a factor of 4 in comparison with single-shot pumping. An energy dispersion of 0.9 % for the first Stokes component is obtained in hydrogen at a relative energy dispersion of ytterbium laser pulses of 0.4 %. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical device for in-line and real-time monitoring of microorganisms

A multi-wavelength laser diode based optical sensor system capable of monitoring the dynamics and physiological changes of a microorganism culture in real-time. The microorganism culture from a microorganism production chamber is pumped to a flow chamber. Laser diodes emit light at certain wavelengths through the flow chamber, which is sensed by photodiodes. A laser control circuitry is operatively connected to the laser diodes and a signal conditioning circuitry is operatively connected to the photodiodes. A microprocessor reads and records voltage signals corresponding to the wavelengths. A data acquisition system converts said voltage signals into measurements of biological parameters, which are displayed on a graphical user interface and allow a user to monitor the measurements in real time.

47 OTHER INSTRUMENTATION↗