Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

PAREX, A numerical Code for process design and integration

The modeling approach for process design is illustrated in this paper by the work done to qualify the PAREX code to design the flow sheet of a uranium/plutonium splitting operation in a pulsed column. The different flow sheet experimentations are presented along with the simulation results. The qualified code has been successfully used to design the flow sheet of this operation in the first purification cycle of UP2-800 plant at La Hague. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Invited Article: Coherent imaging using seeded free-electron laser pulses with variable polarization: First results and research opportunities

FERMI-Elettra, the first vacuum ultraviolet and soft X-ray free-electron laser (FEL) using by default a 'seeded' scheme, became operational in 2011 and has been opened to users since December 2012. The parameters of the seeded FERMI FEL pulses and, in particular, the superior control of emitted radiation in terms of spectral purity and stability meet the stringent requirements for single-shot and resonant coherent diffraction imaging (CDI) experiments. The advantages of the intense seeded FERMI pulses with variable polarization have been demonstrated with the first experiments performed using the multipurpose experimental station operated at the diffraction and projection imaging (DiProI) beamline. The results reported here were obtained with fixed non-periodic targets during the commissioning period in 2012 using 20-32 nm wavelength range. They demonstrate that the performance of the FERMI FEL source and the experimental station meets the requirements of CDI, holography, and resonant magnetic scattering in both multi- and single-shot modes. Moreover, we present the first magnetic scattering experiments employing the fully circularly polarized FERMI pulses. The ongoing developments aim at pushing the lateral resolution by using shorter wavelengths provided by double-stage cascaded FERMI FEL-2 and probing ultrafast dynamic processes using different pump-probe schemes, including jitter-free seed laser pump or FEL-pump/FEL-probe with two color FEL pulses generated by the same electron bunch.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging of Calibrated Defects in Additively Manufactured Materials: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. Currently, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. As a solution to NDE of AM, we are developing pulsed thermal imaging which is non-contact, one-sided, and scalable to arbitrary size and shape of the AM parts. Pulsed thermography (PT) system utilizes a high intensity flash lamp to rapidly heat surface of sample, and a high sensitivity fast-frame megapixel infrared (IR) camera to capture data of surface temperature variations. The acquired data cube consists of a stack of surface temperature images taken at different times. Information about material internal defects is extracted by analyzing the data cube. This report provides results of preliminary performance evaluation of pulsed thermal imaging capability in detection of imprinted flaws in AM metallic structures. The flaws were introduced into AM parts as imprinted hemispherical low density regions, consisting of trapped un-sintered metallic powder. Specimens for developed for this study consisted of AM stainless steel 316 and Inconel 718 plates. The diameters of imprinted defects varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. Pulsed thermal tomography (PTT) processes the measured data cube to obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. PTT has been previously used in imaging of similar size flat bottom hole (FBH) simulated defects in stainless steel 316 and Inconel 718 specimens. In the study involving AM specimens, PTT imaging results have shown that 1mm-diameter defects located 1mm and 2mm below the surface of specimens were detectable. Larger size defects were detectable at greater depth. We also explored an alternative approach to detection of material flaws in PT data cube, which is using neural learning-based approach to blind source separation. Detection of small material defects requires finding features in the data cube which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with phtotothermics, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

36 MATERIALS SCIENCE↗

Heat Loss Correction Factor for Fireball Yield Measurements

Fireball yield calculations are performed using Taylor’s radius equation. However, at early times, the x-ray diffusion process has a significant effect on the size of the fireball, and at late times the shock wave degenerates into an acoustic wave. Thus, earlier research determined that the range of validity for Taylor’s equation was in the scaled time regime of 0.004–0.008 s. So, when performing a yield calculation, the only values that are analyzed are those that lie within that range of validity. While Taylor’s equations offer an approximation of the scaled yield, they also rely on several assumptions. For example, the equations assume that the shock wave is adiabatic, when, in fact, the first light pulse on the nuclear test films, which occurs as the shock wave is forming, suggests that the shock wave is not adiabatic. Furthermore, the amount of heat loss from the shock wave that occurs prior to the scaled time regime of 0.004–0.008 s can change significantly as a function of air density. This may cause the shock wave radius to be smaller relative to the assumed adiabatic shock wave. Therefore, the objective of this project was to determine the correction factor for heat transfer, which should be applied in order to produce a more accurate approximation of the weapon’s yield.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Structure and Dynamics of Polysulfide Clusters in a Nonaqueous Solvent Mixture of 1,3-Dioxolane and 1,2-Dimethoxyethane

Molecular clustering and associated dynamic processes of lithium polysulfide species were unraveled using classical molecular dynamics and ab initio metadynamics calculations. The spectroscopic signatures of polysulfide clusters were analyzed using a multimodal analysis including experimental and computational nuclear magnetic resonance (NMR) and X-ray absorption spectroscopies. Lithium polysulfide solutes (Li 2 S 4 , Li 2 S 6 , and Li 2 S 8 ) and their mixtures in a 1,3-dioxolane and 1,2-dimethoxyethane (DOL/DME) solvent undergo aggregation driven by intramolecular lithium–sulfur (Li–S) interactions, leading to distributions of cluster sizes, which could critically influence the functioning of lithium–sulfur batteries. Representative polysulfide clusters with systematic increases in molecular size were extracted from the classical molecular dynamics trajectories for subsequent structural and spectroscopic property calculations using density functional theory analysis. Structural analysis of these clusters reveals progressively decreasing solvent involvement in Li+ coordination varying from Li 2 S 4 to Li 2 S 8 , with more pronounced variation and changes in DME compared with those in DOL. These observations are reflected in the analysis of the experimental and theoretical 7 Li and 17 O NMR chemical shifts and pulsed field gradient-NMR diffusion measurements. A comparison of experimental and theoretical S K-edge X-ray absorption near edge spectra shows that relatively large lithium sulfide chain clusters are likely to occur in the DOL/DME-solvated lithium sulfide systems. Ab initio metadynamics simulations and NMR analysis indicate that Li + solvated by only the solvent can occur through Li + dissociation from sulfide chains. However, the occurrence of “sulfide-free” Li + is a minor mechanism compared with the dynamic aggregation and shuttling processes of polysulfide solvates in DOL/DME-based electrolytes of Li–S batteries. Overall, atomistic insights gained about clustering and lithium exchange dynamics will be critical for the predictive understanding of the polysulfide shuttling and nucleation process that dictates the Li–S battery performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating the performance of an ion luminescence probe as a multichannel fast-ion energy spectrometer using pulse height analysis

We investigate the capability of a fast-ion luminescent probe to operate as a pulse height ion energy analyzer. An existing high sensitivity system has been reconfigured as a single channel ion detector with an amplifier to give a bandwidth comparable to the phosphor response time. A digital pulse processing method has been developed to determine pulse heights from the detector signal so as to obtain time-resolved information on the ion energy distribution of the plasma ions lost to the wall of the TJ-II stellarator. Finally, the potential of this approach for magnetic confined fusion plasmas is evaluated by studying representative TJ-II discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e crystal calorimeter

The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $\mu^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021. The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates %\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{\mu e} = \frac{\mu^- + A(Z,N) \to e^- +A(Z,N)}{\mu^- + A(Z,N) \to \nu_{\mu} ^- +A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). This will improve the current limit of four order of magnitudes with respect to the previous best experiment. Mu2e complements and extends the current search for $\mu \to e \gamma$ decay at MEG as well as the direct searches for new physics at the LHC. The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons ($\sim 10^{10} \mu/$ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controllable generation of reactive oxygen species by femtosecond-laser irradiation

Femtosecond lasers have been advancing Biophotonics research in the past two decades with multiphoton microscopy, microsurgery, and photodynamic therapy. Nevertheless, laser irradiation is identified to bring photodamage to cells via reactive oxygen species (ROS) generation with unclear mechanism. Meanwhile, currently in biological researches, there is no effective method to provide controllable ROS production precisely, which originally is leaked from mitochondria during respiration and plays a key role in a lot of important cellular processes and cellular signaling pathways. In this study, we show the process of how the tightly focused femtosecond-laser induces ROS generation solely in mitochondria at the very beginning and then release to cytosol if the stimulus is intense enough. At certain weak power levels, the laser pulses induce merely moderate Ca{sup 2+} release but this is necessary for the laser to generate ROS in mitochondria. Cellular original ROS are also involved with a small contribution. When the power is above a threshold, ROS are then released to cytosol, indicating photodamage overwhelming cellular repair ability. The mechanisms in those two cases are quite different. Those results clarify parts of the mechanism in laser-induced ROS generation. Hence, it is possible to further this optical scheme to provide controllable ROS generation for ROS-related biological researches including mitochondrial diseases and aging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing a laser shockwave model for characterizing diffusion bonded interfaces

The US National Nuclear Security Agency has a Global Threat Reduction Initiative (GTRI) with the goal of reducing the worldwide use of high-enriched uranium (HEU). A salient component of that initiative is the conversion of research reactors from HEU to low enriched uranium (LEU) fuels. An innovative fuel is being developed to replace HEU in high-power research reactors. The new LEU fuel is a monolithic fuel made from a U-Mo alloy foil encapsulated in Al-6061 cladding. In order to support the fuel qualification process, the Laser Shockwave Technique (LST) is being developed to characterize the clad-clad and fuel-clad interface strengths in fresh and irradiated fuel plates. LST is a non-contact method that uses lasers for the generation and detection of large amplitude acoustic waves to characterize interfaces in nuclear fuel plates. However, because the deposition of laser energy into the containment layer on a specimen's surface is intractably complex, the shock wave energy is inferred from the surface velocity measured on the backside of the fuel plate and the depth of the impression left on the surface by the high pressure plasma pulse created by the shock laser. To help quantify the stresses generated at the interfaces, a finite element method (FEM) model is being utilized. This paper will report on initial efforts to develop and validate the model by comparing numerical and experimental results for back surface velocities and front surface depressions in a single aluminum plate representative of the fuel cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental demonstration of enhanced self-amplified spontaneous emission by photocathode temporal shaping and self-compression in a magnetic wiggler

In this paper we demonstrate experimentally the generation of attosecond soft X-ray free-electron laser (XFEL) pulses based on a novel approach to enhanced self-amplfied spontaneous emission. Instead of utilizing an external laser, we shape the electron beam at the cathode by laser pulse stacking. We enhance the high-current spike in the beam profile through a self-compression process which uses short-range coherent synchrotron radiation in a wiggler and a downstream magnetic chicane. The undulator taper is then matched with the energy chirp along the beam for attosecond XFEL generation. Start-to-end simulations are performed to demonstrate the proposed method. The measured spectra suggest that a ~250 as pulse duration is achieved at ~940 eV in the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

History of HERMES III Diode to Z-Pinch Breakthrough and Beyond (learning about Pulsed Power and Z-Pinch ICF)

HERMES III and Z are two flagship accelerators of Sandia s pulsed-power program developed to generate intense ɤ-ray fields for the study of nuclear radiation effects, and to explore high energy-density physics (including the production of intense x-ray fields for Inertia Confinement Fusion [ICF]), respectively. A diode at the exit of HERMES III converts its 20-MeV electron beam into ɤ-rays. In contrast, at the center of Z, a z-pinch is used to convert its 20-MA current into an intense burst of x-rays. Here the history of how the HERMES III diode emerged from theoretical considerations to actual hardware is discussed. Next, the reverse process of how the experimental discovery of wire-array stabilization in a z-pinch, led to a better theory of wire-array implosions and its application to one of the ICF concepts on Z--the DH (Dynamic Hohlraum) is reviewed. Lastly, the report concludes with how the unexpected axial radiation asymmetry measured in the DH is understood. The first discussion illustrates the evolution of physics from theory-to-observation-to-refinement. The second two illustrate the reverse process of observation-to-theory-to-refinement. The histories are discussed through the vehicle of my research at Sandia, illustrating the unique environment Sandia provides for personal growth and development into a scientific leader.

Sanford, Thomas William Lou↗

Impact of f-element complexation on the radiolytic robustness of separations ligands

Impact of f-element complexation on the radiolytic robustness of separations ligands Gregory P. Horne, Makayla R. Baxter, Corey D. Pilgrim, Travis S. Grimes, Center for Radiation Chemistry Research, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID, 83415, USA Cristian Celis Barros, Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306, USA. E-mail: ccelisbarros@fsu.edu Andrew R. Cook, Department of Chemistry, Brookhaven National Laboratory, Upton, New York, 11973, USA Stephen P. Mezyk, Department of Chemistry and Biochemistry, California State University Long Beach, 1250 Bellflower Boulevard, Long Beach, California, 90840-9507, USA The effects of ionizing radiation are ubiquitous throughout all aspects of a nuclear fuel cycle. However, the complexity and intensity of these effects are greatest during the management of used nuclear fuel, owing to the presence of a wide spectrum of radionuclides from neutron capture and fission processes. With regards to used nuclear fuel (UNF) reprocessing, radiation-induced processes typically promote the destruction of active compounds (e.g., complexants and additives) with the concomitant formation of potentially detrimental degradation products and corresponding changes in physical and chemical properties, which ultimately impact the effectiveness and longevity of a given reprocessing system. Concerning UNF complexants, radiation chemistry studies have historically focused on their radiation robustness in the absence of the metal ions they were designed to selectively complex. This knowledge gap is worrisome as previous studies on aqueous phase complexants have demonstrated significant changes in radiolytic behavior upon metal ion complexation.1-4 More recently, the rate of reaction of the n-dodecane radical cation—believed to be the major organic phase radiation-induced transient species responsible for complexant radiolysis in n-dodecane based solvent systems—with hexa-n-octylnitrilo-triacetamide (HONTA) was shown to increase by an order-of-magnitude upon complexation of europium or americium.5 These findings have significant implications on the projected longevity of complexants in UNF reprocessing solvent systems. Consequently, a thorough understanding of metal ion complexation effects on the radiolytic integrity of UNF complexants is essential to evaluate their potential for process application. Presented here are two recent studies from the Idaho National Laboratory Center for Radiation Chemistry Research group that demonstrate the various impacts of f-element complexation (uranium, americium, and lanthanides) on the radiolytic integrity (gamma and electron pulse) of tributyl phosphate (TBP), N,N-di-(2-ethylhexyl)butyramide (DEHBA), N,N-di-2-ethylhexylisobutryamide (DEHiBA), and 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP]) under UNF reprocessing conditions. References 1) Bhattacharyya and Kundu, Int. J. Radiat. Phys. Chem., 1971, 3, 1. 2) Kundu and Matuura, Int. J. Radiat. Phys. Chem., 1975, 7, 565. 3) Ilan and Czapski, Biochimica et Biophysica Acta, 1977, 498, 386. 4) Buettner, Doherty, and Patterson, Fed. Euro. Biochem. Soc., 1983, 158 (1), 143. 5) Toigawa, Peterman, Meeker, Grimes, Zalupski, Mezyk, Cook, Yamashita, Kumagai, Matsumura, Horne, PCCP, 2021, 23, 1343.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Diverse methods of analyzing neutron detector signal for power monitoring in commercial fast reactors

In a fast reactor, the measurement of instantaneous power, accurately at any point of time is of prime importance. To control the reactor power within its design limit for safe operation, measurement of power and safety functions operated by different systems based on power is required. This is done with neutron detectors from which signal come as current pulses in random following Poisson distribution. Due to heavy overlap, individual pulse counting is extremely difficult beyond certain frequency. So to count pulses in the detector output in a given length of time, which will be measure of power in the reactor, indirect method of signal processing is applied here. After applying signal processing methods on the detector output, linear relation is established between maximum amplitude of absolute of FFT (Fast Fourier Transform) of the signal and no of pulses in a given length of time of the signal i.e. rate of arrival of pulses to the detector. This linear relation is verified in different ways i.e. with simulated fixed rate of arrival of the pulses, random rate of arrival of the pulses and with neutron detector simulator output. The paper explains various stages of development and testing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Synthesis and characterization of nanoapatites organofunctionalized with aminotriphosphonate agents

Organofunctionalized apatite nanoparticles were prepared using a one step process involving dissolution/precipitation of natural phosphate rock and covalent grafting of nitrilotris(methylene)triphosphonate (NTP). The synthesized materials were characterized by Brunauer-Emmett-Teller (BET) surface measurement, thermogravimetry, inductively coupled plasma emission spectroscopy (ICP-ES), elemental analysis, multinuclear solid state cross-polarization/magic angle spinning (CP/MAS) and single-pulse NMR spectroscopy, transmission electron microscopy (TEM) and energy dispersive X-ray analysis (EDXA). After grafting BET measurements yielded particle specific surface areas ranging from 88 to 193 m{sup 2} g{sup -1} depending on the grafted phosphonate. The results show that the surfaces of the nanoapatite particles can be covered with functional groups bound through a variable number of R-P-O-Ca bonds to render them organoapatites. - Graphical Abstract: Hydroxyapatite in the form of naturally occurring phosphate rock is converted in the presence of nitrilotris(methylene)triphosphonate (NTP) to high surface area apatite nanoparticles (dimensions measured by TEM) with NTP-functionalized surfaces. Highlights: Black-Right-Pointing-Pointer Surface functionalized hydroxyapatite nanoparticles are prepared from natural phosphate rock in a one-step process. Black-Right-Pointing-Pointer Covalent grafting of amine phosphonates to the nanoparticle surface is simultaneously accomplished by the presence of the organic molecules in the solution. Black-Right-Pointing-Pointer Mesoporous particles of high surface area are created. Black-Right-Pointing-Pointer Surface coverage is controlled by the concentration of amine phosphonate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation study of a 'fission electron-collection' neutron detector

In this work, a 'fission electron-collection' neutron detector was studied using the Monte Carlo method. The detector consists of two metal electrodes mounted in a vacuum, named coated and collection electrodes, respectively. The first electrode is coated with triuranium octoxide. The detector uses the 'fission electron-collection' technique, which does not need an intermediate material but directly collects electrons from the coating. Such a detector can realize a flat energy response and a fast time response, both of which are important in the fluence measurement of pulsed neutron sources. In this paper, the physical processes of detection are presented, as well as Monte Carlo simulation studies using the Geant4 toolkit. From the results, the sensitivity of the detector is approximately 1.5 x 10{sup -21} [C/(n/cm{sup 2})], and the FWHM of response function is 2.5 nanoseconds. Additionally, the characterization of escaping electrons is also presented, and the sensitivity of the detector is determined for various coating thicknesses. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transition between inverse and direct energy cascades in multiscale optical turbulence

Transition between inverse and direct energy cascades in multiscale optical turbulence. Multiscale turbulence naturally develops and plays an important role in many fluid, gas, and plasma phenomena. Statistical models of multiscale turbulence usually employ Kolmogorov hypotheses of spectral locality of interactions (meaning that interactions primarily occur between pulsations of comparable scales) and scale-invariance of turbulent pulsations. However, optical turbulence described by the nonlinear Schrodinger equation exhibits breaking of both the Kolmogorov locality and scale-invariance. A weaker form of spectral locality that holds for multi-scale optical turbulence enables a derivation of simplified evolution equations that reduce the problem to a single scale modeling. We present the derivation of these equations for Kerr media with random inhomogeneities. Then, we find the analytical solution that exhibits a transition between inverse and direct energy cascades in optical turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined Assay Systems for the Characterisation of Historical ILW at of the Dounreay Shaft and Silo-18140

In 1955 the Dounreay nuclear power development establishment was created on the northern coast of Scotland primarily to pursue the UK Government policy of developing Fast Breeder Reactor (FBR) technology. The site operated then by the United Kingdom Atomic Energy Authority (UKAEA) saw the development, test and operation of 3 nuclear reactors, two of them FBRs, alongside fabrication and reprocessing facilities for the FBR fuel elements. From the late 1950's until 1977 Intermediate Level radioactive Waste (ILW) generated on site was disposed of into a 65 m deep, 4.6 m diameter shaft. In January 1977, an explosion thought to be caused by hydrogen generated from sodium and potassium wastes reacting with water occurred in the upper part of the shaft, thus stopping any further waste disposal. A second ILW storage facility, the ILW-Silo, started operation in 1971 to deal with the increasing volume of intermediate level waste generated on site in the mid-1960's and continued receiving waste until 1998. The decommissioning of the Shaft and Silo facilities is a challenging engineering task due to the complexity and potential hazards linked with the retrieval and handling of historical waste. Following recovery it is intended to shred the majority of the waste and load it into 200-l assay drums. Sludges would be separated and solidified within a special annulus drum to make them suitable for assay. To support the decommissioning strategies put forward by Dounreay Site Restoration Limited (DSRL), Mirion Technologies Canberra UK Ltd have designed and completed the manufacture of a pair of combined non-destructive waste assay (NDA) systems. The two identical automated ILW counters are intended to provide a means to characterise the waste materials by performing active and passive neutron measurement as well as segmented high resolution gamma spectrometry (HRGS) of 200-l sacrificial waste drums. The active neutron technique is based on the Differential Die Away (DDA) technique using a pulsed Deuterium-Tritium neutron generator to interrogate fissile material present in the waste. The active neutron measurements support, as well as the passive neutron coincidence measurements, a matrix correction capability by use of an Add-a-Source mechanism. The publication will describe in broad lines the approach proposed by DSRL in the processing of the waste retrieved from both the Shaft and Silo facilities. It will also present a description of the overall design of the NDA counters, illustrating how the measurements to be performed will allow DSRL to safely characterise the retrieved waste materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗