Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear physics detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The polarization sensitivity of GRETINA

Compton polarimeters have played an important role in the study of nuclear structure physics, but have often been limited in their applications because of relatively low -ray detection efficiency. With the advent of -ray tracking detector arrays, which feature nearly solid angle coverage and the ability to identify the location of Compton-scattering events to within a few millimeters, this limitation can be overcome. Here we present a characterization of the performance of the Gamma Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter using the 24 Mg(p,p') reaction at 2.45 MeV proton energy. We also discuss a new capability added to the simulation package UCGretina to simulate the emission of polarized photons, and compare it to the measured data. Lastly, we use these simulations to predict the performance of the Gamma Ray Energy Tracking Array (GRETA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Near Detectors for a Neutrino Factory

The baseline design for a Neutrino Factory includes the need for one or more near detectors.The near detectors must be designed to carry out measurements essential to the sensitivity of the oscillation-physics program. In addition, the intense neutrino beam delivered by the Neutrino Factory makes it possible to carry out a unique neutrino-physics program at the near detectors. This program includes fundamental electroweak and QCD physics. The near detector must also be capable of searching for new physics, for example by detecting tau-leptons which are particularly sensitive probes of non-standard interactions at source and at detection. This paper is extracted from the Near Detector chapter of the Neutrino Factory Interim Design Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Fission Investigation with Twin Ionization Chamber

The purpose of the present paper was to report the recent results, obtained in development of digital pulse processing mathematics for prompt fission neutron (PFN) investigation using twin ionization chamber (TIC) along with fast neutron time-of-flight detector (ND). Due to well known ambiguities in literature (see refs. [4, 6, 9 and 11]), concerning a pulse induction on TIC electrodes by FF ionization, we first presented detailed mathematical analysis of fission fragment (FF) signal formation on TIC anode. The analysis was done using Ramo-Shockley theorem, which gives relation between charged particle motion between TIC electrodes and so called weighting potential. Weighting potential was calculated by direct numerical solution of Laplace equation (neglecting space charge) for the TIC geometry and ionization, caused by FF. Formulae for grid inefficiency (GI) correction and digital pulse processing algorithms for PFN time-of-flight measurements and pulse shape analysis are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY07 Final Report for Calibration Systems

Remote infrared (IR) sensing provides a valuable method for detection and identification of materials associated with nuclear proliferation. Current challenges for remote sensors include minimizing the size, mass, and power requirements for cheaper, smaller, and more deployable instruments without affecting the measurement performance. One area that is often overlooked is sensor calibration design that is optimized to minimize the cost, size, weight, and power of the payload. Yet, an on-board calibration system is essential to account for changes in the detector response once the instrument has been removed from the laboratory. The Calibration Systems project at Pacific Northwest National Laboratory (PNNL) is aimed towards developing and demonstrating compact quantum cascade (QC) laser-based calibration systems for infrared sensor systems in order to provide both a spectral and radiometric calibration while minimizing the impact on the instrument payload. In FY05, PNNL demonstrated a multi-level radiance scheme that provides six radiance levels for an enhanced linearity check compared to the currently accepted two-point scheme. PNNL began testing the repeatability of this scheme using a cryogenically cooled, single-mode quantum cascade laser (QCL). A cyclic variation in the power was observed that was attributed to the thermal cycling of the laser's dewar. In FY06, PNNL continued testing this scheme and installed an auxiliary liquid nitrogen reservoir to limit the thermal cycling effects. Although better repeatability was achieved over a longer time period, power fluctuations were still observed due to the thermal cycling. Due to the limitations with the cryogenic system, PNNL began testing Fabry-Perot QCLs that operate continuous-wave (cw) or quasi-cw at room temperature (RT) in FY06. PNNL demonstrated a multi-level scheme that provides five radiance levels in 105 seconds with excellent repeatability. We have continued testing this repeatability in FY07. A burn-in effect appears in which the power increases over a certain time period. Repeatability better than 1%, however, is demonstrated for most of the radiance levels after this initial burn-in. In FY06, PNNL also began investigating a fiber-coupled RT QCL for a compact IR calibration source. PNNL demonstrated a uniform beam profile by measuring a time-averaged response and modulating the fiber optic with a motor to minimize the effects of speckle. In FY07, PNNL examined the power stability of fiber-coupled QCLs. Feedback appears to degrade the stability so that anti-reflective coatings for fibers may be essential. In FY07, PNNL continued to investigate the stability of room temperature QCLs as well as the measurement technique to provide a quantitative estimate for the measurement uncertainty. We designed and built a custom environmental enclosure to reduce the measurement uncertainty. After an initial burn-in, we have achieved uncertainties better than 0.1% for data collected over almost 100 hours of operation. We also built a bench-top system to demonstrate how the QC laser can be used to calibrate a microbolometer array and illustrated the importance of a multi-point calibration.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Partial wave analysis of 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓 and cross section measurement of 𝑒 + ⁢𝑒 − → 𝜋 ± ⁢𝑍 𝑐 ⁢(3900) ∓ from 4.1271 to 4.3583 GeV

Based on 12.0 fb −1 of 𝑒 + ⁢𝑒 − collision data samples collected by the BESIII detector at center-of-mass energies from 4.1271 to 4.3583 GeV, a partial wave analysis is performed for the process 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓. The cross sections for the subprocesses 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝑍 𝑐 ⁢(3900) − + c.c. → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓, 𝑓 0 ⁡(980)⁢(→ 𝜋 + ⁢𝜋 − )⁢𝐽/𝜓, and (𝜋 + ⁢𝜋 − ) S−wave⁢ 𝐽/𝜓 are measured for the first time. The mass and width of the 𝑍 𝑐 ⁢(3900) ± are determined to be 3884.6 ± 0.7 ± 3.3 MeV/𝑐 2 and 37.2 ± 1.3 ± 6.6 MeV, respectively. The first errors are statistical and the second systematic. The final state (𝜋 + ⁢𝜋 − ) S−wave ⁢𝐽/𝜓 dominates the process 𝑒 + ⁢𝑒 − → 𝜋 + ⁢𝜋 − ⁢𝐽/𝜓. By analyzing the cross sections of 𝜋 ±⁢ 𝑍 𝑐 ⁢(3900) ∓ and 𝑓 0 ⁡(980)⁢𝐽/𝜓, 𝑌⁡(4220) has been observed. Its mass and width are determined to be 4225.7 ± 4.1 ± 3.4 MeV/𝑐 2 and 57.5 ± 9.4 ± 12.1 MeV, respectively.

lepton colliders↗

The GDR Gamma Decay of Nuclei Under Extreme Conditions

The measurements of the gamma decay from the giant dipole resonance (GDR) at finite temperature and far from stability is used to obtain information on the properties of the nucleus. The study of the gamma decay from the giant dipole resonance (GDR) at finite temperature and far from stability allows to obtain information on the properties of nuclei in different regimes. Exclusive measurements of gamma-decays with fusion reactions were made at LNL (INFN) and GSI in order to address 2 different physical problems. First, the measurement of the temperature dependence of the GDR width up to T = 4 MeV in the mass region A = 130 will be shown together with its interpretation in terms of thermal shape fluctuations calculations. Secondly, the search for the pygmy dipole resonance in neutron rich {sup 68}Ni nucleus produced by fragmentation at GSI will be presented. Coulomb excitation at 600 MeV/nucleon was employed and the gamma-rays were detected with the RISING array.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of IAEA Environmental Samples for Plutonium and Uranium by ICP/MS in Support Of International Safeguards

A method for the separation and determination of total and isotopic uranium and plutonium by ICP-MS was developed for IAEA samples on cellulose-based media. Preparation of the IAEA samples involved a series of redox chemistries and separations using TRU® resin (Eichrom). The sample introduction system, an APEX nebulizer (Elemental Scientific, Inc), provided enhanced nebulization for a several-fold increase in sensitivity and reduction in background. Application of mass bias (ALPHA) correction factors greatly improved the precision of the data. By combining the enhancements of chemical separation, instrumentation and data processing, detection levels for uranium and plutonium approached high attogram levels.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Reflected Neutron Effects in Multiplicity Measurements of Bare HEU Assemblies

In a passive multiplicity characterization of highly enriched uranium (HEU) assemblies, fission chains are initiated by the characteristically fast neutrons from spontaneous fission of 238 U and 235 U as well as cosmic-ray spallation neutrons. Active interrogation of HEU uses other physical mechanisms for starting chains by inducing fission from high-energy neutrons, high-energy gamma-rays, delayed neutrons, or thermal neutrons. In all cases a contribution to the initiation of fission chains is the reflection of neutrons that initially escape the assembly and re-enter it after undergoing some scattering. The reflected neutron flux is geometry dependent and a combination of fast and thermal energies. The reflected thermal neutron contribution occurs hundreds of microseconds after the beginning of the fission chain and can be distinguished from the cosmic-ray spallation neutrons unrelated to fission chains, resulting in an HEU detection signature with high signal-to-noise. However, the reflected thermal neutron flux can be eliminated with an efficient thermal neutron absorber to investigate reflected neutron effects. In this paper, active and passive multiplicity measurements with HEU oxide assemblies of up to 16 kg of fuel pins and HEU metal assemblies of up to five 18 kg storage castings are reported. Each case demonstrates the differences in HEU signature when a borated thermal neutron absorber is present and shows the various detectable signatures with 3He proportional counters, the standard detector for differential die-way and neutron multiplicity measurements, and liquid scintillators, a detector capable of operating on the timescale of fission chains.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Cost CE-NMR with Microcoils for Chemical Detection

Understanding speciation in solids and solutions is important for environmental and toxicological purposes. Capillary electrophoresis (CE) is a simple rapid separation technique that can be used to identify species in solution. CE is particularly is well suited for rapid separations of metal containing samples. Direct on-capillary measurement of metal compound speciation can be obtained with nuclear magnetic resonance (NMR). The development of a low-cost microcoil CE-NMR system for in situ characterization of samples of interest is discussed. High precision laser lithography is used to produce copper sputtered microcoils that have comparable resistivity and quality factors to that of hand wound microcoils. A portable NMR system coupled with a CE system has the potential to identify chemical species in aqueous solutions. In addition, transient isotachophoresis can separate and pre-concentrate samples of interest to obtain separate chemical peaks for speciation by online NMR analysis. We are developing separation assays to determine the speciation of chemical complexes in solutions with minimal perturbation to the original sample equilibrium. On-line NMR measurements will be made downstream of the UV detector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lessons Learned In Developing The VACIS Products

SAIC's development of VACIS provides useful 'lessons learned' in bridging the gap from an idea to a security or contraband detection product. From a gamma densitometer idea for solving a specific Customs Service (CS) requirement (detection of drugs in near-empty tanker trucks) in mid-1990's, SAIC developed a broad line of vehicle and cargo inspections systems (over 500 systems deployed to date) based on a gamma-ray radiographic imaging technique. This paper analyzes the reasons for the successful development of VACIS and attempts to identify ''lessons learned'' useful for future security and contraband detection product developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Source Characterization. Year 2 of 3 Summary

The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comment on 'Time modulation of K-shell electron capture decay rates of H-like heavy ions at GSI experiments.'

A Comment on the Letter by A.N. Ivanov and P. Kienle, Physical Review Letters volume 103, Issue 6, 062502 (2009). The authors of the Letter offer a Reply to experimental data at GSI, the rates of the number of daughter ions, produced by the nuclear K shell electron capture decays of the H-like heavy ions with one electron in the K shell, such as {sup 140}Pr{sup 58+}, {sup 142}Pm{sup 60+}, and {sup 122}I{sup 52+}, are modulated in time with periods T{sub EC} of the order of a few seconds, obeying an A scaling T{sub EX}=A/20 s, where A is the mass number of the mother nuclei, and with amplitudes a{sub d {sup EC}}{approx}0.21. We show that these data can be explained in terms of the interference of two massive neutrino mass eigenstates. The appearance of the interference term is due to overlap of massive neutrino mass eigenstate energies and of the wave functions of the daughter ions in two-body decay channels, caused by the energy and momentum uncertainties introduced by time differential detection of the daughter ions in GSI experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Antenna arrays for neutrino mass measurements with cyclotron radiation emission spectroscopy

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurements of kinetic energies of charged particles, pioneered by the Project 8 experiment to measure the neutrino mass using the tritium end-point method. It was recently employed for the first time to measure the molecular tritium spectrum and place a limit on the neutrino mass using a cubic-centimeter-scale detector. Future direct neutrino mass experiments are developing the technique to overcome the systematic and statistical limitations of current detectors. Here, this paper describes one such approach, namely the use of antenna arrays for CRES in free space. Phenomenology, detector design, simulation, and performance estimates are discussed, culminating with an example design with a projected sensitivity of 𝑚 𝛽 < ⁢0.04 eV/𝑐 2 . Prototype antenna array measurements are also shown for a demonstrator-scale setup as a benchmark for the simulation. By consolidating these results, this paper serves as a comprehensive reference for the development and performance of antenna arrays for CRES.

Physics - Nuclear physics and radiation physics↗

Nuclear-spin optical rotation in xenon

We report that the nuclear-spin optical rotation (NSOR) effect, which has potential applications in correlated nuclear-spin-resonance optical spectroscopy, has previously been explored experimentally and theoretically in liquid Xe. Calculations of the Xe NSOR constant are very challenging because the result is sensitive to correlations, relativistic effects, and the choice of basis, with strong cancellation between contributions from lowest and remaining states. The relativistic configuration-interaction many-body-theory approach, presented here, is promising because this approach has been successful in predicting various properties of noble-gas atoms, such as energies, oscillator strengths (OSs), Verdet constants, and photoionization cross sections. However, correlations become stronger along the sequence of noble-gas atoms and the theoretical accuracy in Xe is not as high as, for example, in neon and argon. To improve the accuracy of the Xe Verdet and NSOR constants, which are calculated as explicit sums over the excited states, theoretical values for the several lowest levels are replaced with empirical values of energies, OSs, and hyperfine structure constants. We found that the Xe Verdet constant is in excellent agreement with accurate measurements. To take into account liquid effects, empirical data for energy shifts were also used to correct the NSOR constant. In conclusion, the resulting Xe NSOR constant is in a good agreement with experiment, although the liquid-state effect is treated quite approximately.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Event-by-event direction reconstruction of solar neutrinos in a high light-yield liquid scintillator

The direction of individual B 8 solar neutrinos has been reconstructed using the SNO + liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils

A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ∼4 keV showed sensitivity to ∼20 keV nuclear recoils with no observable bubble nucleation by 𝛾-ray interactions. Here, this paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ∼1 keV nuclear recoils while remaining insensitive to bubble nucleation by 𝛾-rays. A data-driven calibration of the chamber’s nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by 𝛾-ray-induced Auger cascades, with a limit of <1.1 ×10 −6 set at 0.50 keV, the lowest thermodynamic threshold explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗