Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mathematical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Mathematical simulation of the amplification of 1790-nm laser radiation in a nuclear-excited He – Ar plasma containing nanoclusters of uranium compounds

The possibility of applying dusty active media in nuclearpumped lasers has been considered. The amplification of 1790-nm radiation in a nuclear-excited dusty He – Ar plasma is studied by mathematical simulation. The influence of nanoclusters on the component composition of the medium and the kinetics of the processes occurring in it is analysed using a specially developed kinetic model, including 72 components and more than 400 reactions. An analysis of the results indicates that amplification can in principle be implemented in an active laser He – Ar medium containing 10-nm nanoclusters of metallic uranium and uranium dioxide. (lasers)

74 ATOMIC AND MOLECULAR PHYSICS↗

A Note on the Nomenclature in Neutron Multiplicity Mathematics

The purpose of this technical note is to consolidate the notations used for describing parameters that pertain to neutron multiplicity mathematics relevant to various applications including nonproliferation, international safeguards, and criticality safety among others. The nomenclatures used in these techniques vary widely depending on the origin of the work and their applications. We aim here to consolidate many of the previously used notations in a single document to enhance past, present, and future technical exchanges pertaining to neutron multiplicity. This will help avoid confusion in future publications and will facilitate wider application-independent advancements and utility of peer-reviewed findings. A brief introduction and history of neutron multiplicity counting is presented, followed by a summary of commonly used techniques in a variety of different applications. In each section, we present the notations used in previous publications for the reader’s reference.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mathematical modelling of the concave front in the adjacent high explosive detonation problem

This study presents an analysis of the transition-zone in adjacent high explosive (HE) detonation problems which uses a $D, 𝜅, \dot{D}$ relationship, where $D$ is the detonation front-normal velocity, 𝜅 is the detonation front curvature and $\dot{D}$ is the time derivative of detonation front-normal velocity. Our approach extends the traditional $(D, 𝜅)$ model to accurately predict the behaviour of both diverging and converging detonation shock fronts. Our findings affirm that a hyperbolic type of front evolution equation, enhanced with wave acceleration, provides a robust framework for modelling complex shock front dynamics in HE materials. This approach not only captures the natural effects of straightness and boundary slope jumps in the transition-zone but also bridges the gap between mathematical predictions and experimental observations, offering insights into the behaviour of both diverging and converging detonation propagations in a homogeneous HE.

acceleration↗

Mathematical solutions in internal dose assessment: A comparison of Python-based differential equation solvers in biokinetic modeling

Abstract In biokinetic modeling systems employed for radiation protection, biological retention and excretion have been modeled as a series of discretized compartments representing the organs and tissues of the human body. Fractional retention and excretion in these organ and tissue systems have been mathematically governed by a series of coupled first-order ordinary differential equations (ODEs). The coupled ODE systems comprising the biokinetic models are usually stiff due to the severe difference between rapid and slow transfers between compartments. In this study, the capabilities of solving a complex coupled system of ODEs for biokinetic modeling were evaluated by comparing different Python programming language solvers and solving methods with the motivation of establishing a framework that enables multi-level analysis. The stability of the solvers was analyzed to select the best performers for solving the biokinetic problems. A Python-based linear algebraic method was also explored to examine how the numerical methods deviated from an analytical or semi-analytical method. Results demonstrated that customized implicit methods resulted in an enhanced stable solution for the inhaled 60 Co (Type M) and 131 I (Type F) exposure scenarios for the inhalation pathway of the International Commission on Radiological Protection (ICRP) Publication 130 Human Respiratory Tract Model (HRTM). The customized implementation of the Python-based implicit solvers resulted in approximately consistent solutions with the Python-based matrix exponential method ( expm ). The differences generally observed between the implicit solvers and expm are attributable to numerical precision and the order of numerical approximation of the numerical solvers. This study provides the first analysis of a list of Python ODE solvers and methods by comparing their usage for solving biokinetic models using the ICRP Publication 130 HRTM and provides a framework for the selection of the most appropriate ODE solvers and methods in Python language to implement for modeling the distribution of internal radioactivity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ionization detail parameters and cluster dose: a mathematical model for selection of nanodosimetric quantities for use in treatment planning in charged particle radiotherapy

Abstract Objective . To propose a mathematical model for applying ionization detail (ID), the detailed spatial distribution of ionization along a particle track, to proton and ion beam radiotherapy treatment planning (RTP). Approach . Our model provides for selection of preferred ID parameters ( I p ) for RTP, that associate closest to biological effects. Cluster dose is proposed to bridge the large gap between nanoscopic I p and macroscopic RTP. Selection of I p is demonstrated using published cell survival measurements for protons through argon, comparing results for nineteen I p : N k , k = 2, 3, …, 10, the number of ionizations in clusters of k or more per particle, and F k , k = 1, 2, …, 10, the number of clusters of k or more per particle. We then describe application of the model to ID-based RTP and propose a path to clinical translation. Main results . The preferred I p were N 4 and F 5 for aerobic cells, N 5 and F 7 for hypoxic cells. Significant differences were found in cell survival for beams having the same LET or the preferred N k . Conversely, there was no significant difference for F 5 for aerobic cells and F 7 for hypoxic cells, regardless of ion beam atomic number or energy. Further, cells irradiated with the same cluster dose for these I p had the same cell survival. Based on these preliminary results and other compelling results in nanodosimetry, it is reasonable to assert that I p exist that are more closely associated with biological effects than current LET-based approaches and microdosimetric RBE-based models used in particle RTP. However, more biological variables such as cell line and cycle phase, as well as ion beam pulse structure and rate still need investigation. Significance . Our model provides a practical means to select preferred I p from radiobiological data, and to convert I p to the macroscopic cluster dose for particle RTP.

Engineering↗

A mathematical model to systematically align superconducting radio frequency cavities employing the serial robot kinematic theory

In Superconducting Radio Frequency (SRF) cryomodules, precise alignment of cavities is necessary to ensure high beam quality and to increase the overall energetic efficiency. In the SSR1 (Single Spoke Resonator 1) cryomodule, the cavities are aligned using a system of seven screws which allows to control five Degree of Freedoms (DOFs). The relation between the rotation of each screw and the movement of the cavity is non-linear, thus the aligning process, currently based on a trial-and-error procedure, can be time consuming and affected by human error. In this paper the design of an alignment mathematical model, based on the serial robot kinematic, is described and tested on a SSR1 cavity. Furthermore, the goal of the proposed model is to give a step by step operational procedure that bring the SSR1 cavity to a desired location reducing the uncertainties related to the current operator-driven alignment process.

43 PARTICLE ACCELERATORS↗

Hearing shapes of drums: Mathematical and physical aspects of isospectrality

In a celebrated paper ''Can one hear the shape of a drum?'' M. Kac [Am. Math. Monthly 73, 1 (1966)] asked his famous question about the existence of nonisometric billiards having the same spectrum of the Laplacian. This question was eventually answered positively in 1992 by the construction of noncongruent planar isospectral pairs. This review highlights mathematical and physical aspects of isospectrality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Induced Eddy Currents in Simple Conductive Geometries: Mathematical Formalism Describes the Excitation of Electrical Eddy Currents in a Time-Varying Magnetic Field

In this paper, a complete mathematical formalism is introduced to describe the excitation of electrical eddy currents due to a time-varying magnetic field. The process works by applying a quasistatic approximation to Ampere's law and then segregating the magnetic field into impressed and induced terms. The result is a nonhomogeneous vector Helmholtz equation that can be analytically solved for many practical geometries. Four demonstration cases are then solved under a constant excitation field over all space—an infinite slab in one dimension, a longitudinal cylinder in two dimensions, a transverse cylinder in two dimensions, and a sphere in three dimensions. Numerical simulations are also performed in parallel with analytic computations, all of which verify the accuracy of the derived expressions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-C-BRE-03: Dual Compartment Mathematical Modeling of Glioblastoma Multiforme (GBM)

Purpose: To explore the aggressive recurrence and radioresistence of GBM with a dual compartment tumor survival mathematical model based on intrinsic tumor heterogeneity, cancer stem cells (CSC) and differentiated cancer cells (DCC). Methods: The repopulation and differentiation responses to radiotherapy of a solid tumor were simulated using an Ordinary Differential Equation (ODE). To obtain the tumor radiobiological parameters, we assumed that a tumor consists of two subpopulations, each with its distinctive linear quadratic parameters. The dual compartment cell survival model was constructed as SF(D)=F × exp(-α{sub 1} D-β{sub 1}D{sup 2}) + (1-F) × exp(-α{sub 2}D-β{sub 2}D{sup 2}) for a single fraction of treatment, with F as the fraction of CSC, and α and β describing the radiological properties of each population. Robust least square fitting was performed on clonogenic survival data from one GBM (U373MG) and one NSCLC (H460) cell line. The fit parameters were then used in the ODE model to predict treatment outcome of various treatment schemes. Results: The fit parameters from GBM cell survival data were (F, α{sub 1}, β{sub 1}, α{sub 2}, β{sub 2})=(0.0396, 0.0801, 0.0006, 0.1363, 0.0279), exhibiting two populations with distinctive radiological properties, CSC more radioresistant than DCC. The GBM cell line exhibited significantly poorer tumor control than its single compartment model prediction and NSCLC, which responded well to hypofrationation. The increased radioresistance was due to rapid regrowth of the DCC compartment triggered by its depletion while maintaining a viable CSC population. The rapid regrowth can be reduced by treating dose fractions ≤ 2 Gy with a prolonged treatment period. Conclusion: The interaction between a radioresistant CSC compartment and DCC compartment can explain the poor clinical outcome of GBM after radiotherapy despite dose escalation and hypofractionation attempts. Lower dose fractions result in better treatment outcome but still eventually recurs. Dose escalation beyond 100 Gy and/or differentiation therapy will be vital in achieving GBM tumor control.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-05: 4Ï€ Non-Coplanar Radiotherapy: From Mathematical Modeling to Clinical Implementation

Purpose: To develop and clinically implement 4π radiotherapy, an inverse optimization platform that maximally utilizes non-coplanar intensity modulated radiotherapy (IMRT) beams to significantly improve critical organ sparing. Methods: A 3D scanner was used to digitize the human and phantom subject surfaces, which were positioned in the computer assisted design (CAD) model of a TrueBeam machine to create a virtual geometrical model, based on which, the feasible beam space was calculated for different tumor locations. Beamlets were computed for all feasible beams using convolution/superposition. A column generation algorithm was employed to optimize patient specific beam orientations and fluence maps. Optimal routing through all selected beams were calculated by a level set method. The resultant plans were converted to XML files and delivered to phantoms in the TrueBeam developer mode. Finally, 4π plans were recomputed in Eclipse and manually delivered to recurrent GBM patients. Results: Compared to IMRT utilizing manually selected beams and volumetric modulated arc therapy plans, markedly improved dosimetry was observed using 4π for the brain, head and neck, liver, lung, and prostate patients. The improvements were due to significantly improved conformality and reduced high dose spillage to organs mediolateral to the PTV. The virtual geometrical model was experimentally validated. Safety margins with 99.9% confidence in collision avoidance were included to the model based model accuracy estimates determined via 300 physical machine to phantom distance measurements. Automated delivery in the developer mode was completed in 10 minutes and collision free. Manual 4 π treatment on the GBM cases resulted in significant brainstem sparing and took 35–45 minutes including multiple images, which showed submillimeter cranial intrafractional motion. Conclusion: The mathematical modeling utilized in 4π is accurate to create and guide highly complex non-coplanar IMRT treatments that consistently and significantly outperform human-operator-created plans. Deliverability of such plans is clinically demonstrated. This work is funded by Varian Medical Systems and the NSF Graduate Research Fellowship DGE-1144087.

60 APPLIED LIFE SCIENCES↗

SU-F-E-20: A Mathematical Model of Linac Jaw Calibration Integrated with Collimator Walkout

Purpose: Accurate jaw calibration is possible, but it does not necessarily achieve good junctions because of collimator rotation walkout. We developed a mathematical model seeking to pick an origin for calibration that minimizes the collimator walkout effect. Methods: We use radioopaque markers aligned with crosshair on the EPID to determine the collimator walkout at collimator angles 0°, 90° and 270°. We can accurately calibrate jaws to any arbitrary origin near the radiation field centre. While the absolute position of an origin moves with the collimator walkout, its relative location to the crosshair is an invariant. We studied two approaches to select an optimal origin. One approach seeks to bring all three origin locations (0°–90°–270°) as close as possible by minimizing the perimeter of the triangle formed by these points. The other approach focuses on the gap for 0°–90° junctions. Results: Our perimeter cost function has two variables and non-linear behaviour. Generally, it does not have zero-perimeter-length solution which leads to perfect jaw matches. The zero solution can only be achieved, if the collimator rotates about a single fixed axis. In the second approach, we can always get perfect 0°–0° and 0°–90° junctions, because we ignore the 0°–270° situation. For our TrueBeams, both techniques for selecting an origin improved junction dose inhomogeneities to less than ±6%. Conclusion: Our model considers the general jaw matching with collimator rotations and proposes two potential solutions. One solution optimizes the junction gaps by considering all three collimator angles while the other only considers 0°–90°. The first solution will not give perfect matching, but can be clinically acceptable with minimized collimator walkout effect, while the second can have perfect junctions at the expense of the 0°–270° junctions. Different clinics might choose between these two methods basing on their clinical practices.

60 APPLIED LIFE SCIENCES↗

SU-F-T-414: Mathematical Formulation of Gantry Starting Angle for Right Medial Tangential Arc in Left Intact Partial Breast Irradiation Using Volumetric Modulated Arc Therapy (VMAT)

Purpose: To choose appropriate gantry starting angle for partial left breast irradiation using volumetric modulated arc therapy (VMAT). Methods: A random patient of left breast carcinoma was selected for this study. The slice which was selected for this mathematical formulation was having maximum breast thickness and maximum medial and lateral tangential distance. After this appropriate isocenter was chosen on that CT slice. The distances between various points were measured by the measuring tool in Monaco 5.00.04. Using the various trigonometric equations, a final equation was derived which shows the relationship between Gantry start angle, isocenter Location and tissue thickness. Results: The final equation for gantry start for right medial tangential arc is given asStarting angle = 270°+tan^(−1)(sin(θ)/(x-1/x-2 +cosθ))The above equation was tested for 10 cases and it was found to be appropriate for all the cases. Conclusion: Gantry starting angle for partial arc irradiation depends upon Breast thickness, Distance between Medial and lateral tangent and isocenter location.

60 APPLIED LIFE SCIENCES↗

Mathematical simulation and X-ray diffraction investigation of the crystal structure of 1-phenyl-1-tert-butyl-3-methyl-1,3-dihydroisobenzofuran

An algorithm for using a priori generation of crystal structures by the discrete modeling method for the interpretation of data obtained from single-crystal X-ray diffraction experiments is considered. The crystal structure of 1-phenyl-1-tert-butyl-3-methyl-1,3-dihydroisobenzofuran is mathematically simulated using the discrete modeling of molecular packings and studied by X-ray diffraction. The simulation is performed for two isomers of the initial chemical compound that are possible from the viewpoint of the mechanism of the chemical reaction used in the synthesis of this compound. Appropriate models that can serve as starting models for solving and refining the crystal structure with the use of X-ray diffraction data are chosen from a complete set of calculated structural models in accordance with specific criteria. The structure is solved using a starting model calculated using the discrete modeling method and refined by the full-matrix least-squares procedure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oscillation phenomena and experimental determination of exact mathematical stability zones for magneto-conductivity in metals having complicated Fermi surfaces

We consider the problem of exact experimental determination of the boundaries of Stability Zones for magneto-conductivity in normal metals in the space of directions of magnetic field B. As can be shown, this problem turns out to be nontrivial since the exact boundaries of Stability Zones are in fact unobservable in direct measurements of conductivity. However, this problem can be effectively solved with the aid of the study of oscillation phenomena (cyclotron resonance, quantum oscillations) in normal metals, which reveal a singular behavior on the mathematical boundary of a Stability Zone.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review—Development of Highly Active and Durable Hybrid Compressive Platinum Lattice Catalysts for Polymer Electrolyte Membrane Fuel Cells: Mathematical Modeling and Experimental Work

This review provides a comprehensive overview on the development of highly active and durable platinum catalysts with ultra-low Pt loadings for polymer electrolyte membrane fuel cells (PEMFCs) through a combined mathematical modeling and experimental work. First, simulation techniques were applied to evaluate the validity of the Tafel approximation for the calculation of the mass activity (MA) and specific activity (SA). A one-dimensional agglomeration model was developed and solved to understand the effects of exchange current density, porosity, agglomerate size, Nafion ® film thickness, and Pt loading on the MA and SA. High porosity (> 60%) and agglomerations at high Pt loadings cause the loss of the Tafel approximation and consequently the decrease in MA and SA. A new structure parameter was introduced to estimate the real porous structure using the fractal theory. The volumetric catalyst density was corrected by the fractal dimension (measured by Hg porosimetry), which gave a good agreement with the experimental values. The loading-dependent Tafel equation was then derived, which contains both the utilization and the non-linear scaling factor. Second, activated carbon composite support (ACCS) with optimized surface area, porosity, pore size, and pore size distribution was developed. The hydrophilic/hydrophobic ratio, structural properties (amorphous/crystalline ratio), and the number of active sites were optimized through metal-catalyzed pyrolysis. Stability of ACCS and Pt/ACCS were evaluated using an accelerated stress test (AST). The results indicated that Pt/ACCS showed no significant loss of MA and power density after 5,000 cycles at 1.0–1.5 V, while the commercial Pt/C catalysts showed drastic losses of MA and power density. Finally, monolayers of compressed Pt (core–shell-type Pt 3 Co 1 ) catalysts were structured by diffusing Co atoms (previously embedded in ACCS) into Pt. Compressive Pt lattice (Pt * ) catalysts were synthesized through an annealing procedure developed at the University of South Carolina (USC). The Pt * /ACCS catalyst showed high initial power density (rated) of 0.174 g Pt kW −1 and high stability (24 mV loss) at 0.8 A cm −2 after 30,000 cycles (0.6–1.0 V). The outstanding performance of Pt * /ACCS is due to the synergistic effect of ACCS and compressive Pt * lattice.

25 ENERGY STORAGE↗

Mathematical Model for Li-S Cell with Shuttling-Induced Capacity Loss Approximation

Lithium sulfur (Li-S) batteries have the potential to outperform the current lithium ion batteries and transform the technology of the future. However, dissolution, diffusion, and shuttling of the dissolved polysulfides result in parasitic reactions and substantial capacity loss. To provide a better understanding of the shuttling process, a 1D porous electrode mathematical model has been developed in this paper. An approximation method is used to account for the shuttling-induced capacity loss by adding an extra source/sink term in the material balance equations for the species involved in the parasitic reactions. Shuttling constants used in the source terms can be determined by fitting the model predictions to the experimental measurements. Here, the results showed that by including the approximation method, the model was able to predict the active material loss and the continuous decrease of volume fractions of Li 2 S on the cathode surface. The model sheds light on the capacity loss mechanism occurring inside the cell as a result of the shuttling of polysulfides.

25 ENERGY STORAGE↗

Localized Corrosion: Passive Film Breakdown vs. Pit Growth Stability: Part IV. The Role of Salt Film in Pit Growth: A Mathematical Framework

In Part II of this series, a framework for pit stability established, and it was expanded in Part III to describe salt film formation in pits. It was shown that a salt film was not required for pit stabilization; it is just a consequence of a pit achieving diffusion-controlled growth. A salt film can form on the surface of both metastable and stable pits when the maximum pit dissolution current density, i diss,max , exceeds the diffusion-limited current density, i lim . Based on this clarifying framework, this paper shows mathematically that the main function of a salt film is to adjust the actual potential at pit surface by regulating its thickness, thus to restrict the anodic dissolution rate of pit surface metal at the value of diffusion-limited current density. As a result, the film thickness will respond to any changes in the applied potential, temperature, pit depth, ohmic potential drop in the solution and perforation radius of the pit cover. Additionally, the pit stability criteria that have been discussed previously in the literature are reinterpreted using the new framework, and they are unified by the critical temperatures, potentials and pit depths for pit stabilization and salt film formation proposed in Part III.

36 MATERIALS SCIENCE↗

Mathematical Modeling of Electrochemical Flow Capacitors

Electrochemical flow capacitors (EFCs) for grid-scale energy storage are a new technology that is beginning to receive interest. Prediction of the expected performance of such systems is important as modeling can be a useful avenue in the search for design improvements. Models based off of circuit analogues exist to predict EFC performance, but these suffer from deficiencies (e.g. a multitude of fitting constants that are required and the ability to analyze only one spatial direction at a time). In this paper mathematical models based off of three-dimensional macroscopic balances (similar to models for porous electrodes) are reported. Unlike existing three-dimensional porous electrode-based approaches for modeling slurry electrodes, advection (i.e., transport associated with bulk fluid motion) of the overpotential is included in order to account for the surface charge at the interface between flowing particles and the electrolyte. Doing so leads to the presence of overpotential boundary layers that control the performance of EFCs. These models were used to predict the charging behavior of an EFC under both flowing and non-flowing conditions. Agreement with experimental data was good, including proper prediction of the steady-state current that is achieved during charging of a flowing EFC. (C) The Author(s) 2015. Published by ECS. This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives 4.0 License (CC BY-NC-ND, http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reuse, distribution, and reproduction in any medium, provided the original work is not changed in any way and is properly cited. For permission for commercial reuse, please email: oa@electrochem.org. All rights reserved.

Hoyt, NC↗