Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Development of high field SQUID magnetometer for magnetization studies up to 7 T and temperatures in the range from 4.2 to 300 K

We present the design, fabrication, integration, testing, and calibration of a high field superconducting quantum interference device (SQUID) magnetometer. The system is based on dc SQUID sensor with flux locked loop readout electronics. The design is modular and all the subsystems have been fabricated in the form of separate modules in order to simplify the assembly and for ease of maintenance. A novel feature of the system is that the current induced in the pickup loop is distributed as inputs to two different SQUID sensors with different strengths of coupling in order to improve the dynamic range of the system. The SQUID magnetometer has been calibrated with yttrium iron garnet (YIG) sphere as a standard reference material. The calibration factor was determined by fitting the measured flux profile of the YIG sphere to that expected for a point dipole. Gd{sub 2}O{sub 3} was also used as another reference material for the calibration and the effective magnetic moment of the Gd{sup 3+} could be evaluated from the temperature dependent magnetization measurements. The sensitivity of the system has been estimated to be about 10{sup -7} emu at low magnetic fields and about 10{sup -5} emu at high magnetic fields {approx}7 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metrology and Characterization Challenges for Emerging Research Materials and Devices

The International Technology Roadmap for Semiconductors (ITRS) Emerging Research Materials (ERM) and Emerging Research Devices (ERD) Technology Workgroups have identified materials and devices that could enable continued increases in the density and performance of future integrated circuit (IC) technologies and the challenges that must be overcome; however, this will require significant advances in metrology and characterization to enable progress. New memory devices and beyond CMOS logic devices operate with new state variables (e.g., spin, redox state, etc.) and metrology and characterization techniques are needed to verify their switching mechanisms and scalability, and enable improvement of operation of these devices. Similarly, new materials and processes are needed to enable these new devices. Additionally, characterization is needed to verify that the materials and their interfaces have been fabricated with required quality and performance.

36 MATERIALS SCIENCE↗

Novel 4{pi} Detection System for the Measurement of the {sup 6}Li(n,{alpha}){sup 3}H Reaction Cross Section

A dedicated one-dimensional Time Projection Chamber (1D-TPC) was designed and produced at IRMM to determine the {sup 6}Li(n,{alpha}){sup 3}H cross section in the 0.4-2.8 MeV energy range, aiming at 5% accuracy. The basic TPC components were a twin gridded ionisation chamber (GIC) with interwired electrodes and fast digitisation of the anode and cathode signals. The energy of both reaction products emitted from a thin {sup 6}LiF sample at the common TPC cathode was measured. A Kr(97%)CO{sub 2}(3%) mixture was used as the detector gas at a pressure up to 3.5 bar. A {sup 238}U sample mounted on the cathode of an ionisation chamber without grid was used as the neutron flux monitor. Special care was taken to reduce the experimental sources of uncertainty. The beam-monitor {sup 238}U sample was characterised at IRMM by low-geometry {alpha}-counting with an accuracy of 0.1%. A {sup 6}Li sample was produced at IRMM by vacuum evaporation of {sup 6}LiF onto transparent aluminium backing. The number of {sup 6}Li atoms will be measured via Thermal Neutron Depth Profiling with an expected accuracy of 2% with respect to an IRMM Standard Reference Material. First test measurements were performed using a monoenergetic neutron beam produced by the T(p,n){sup 3}He reaction at the IRMM 7 MV Van de Graaff accelerator. The experimental method and preliminary results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural characterization of Bi{sub 2}Te{sub 3} and Sb{sub 2}Te{sub 3} as a function of temperature using neutron powder diffraction and extended X-ray absorption fine structure techniques

The structure of Bi{sub 2}Te{sub 3} (Seebeck coefficient Standard Reference Material (SRM™ 3451)) and the related phase Sb{sub 2}Te{sub 3} have been characterized as a function of temperature using the neutron powder diffraction (NPD) and the extended X-ray absorption fine structure (EXAFS) techniques. The neutron structural studies were carried out from 20 K to 300 K for Bi{sub 2}Te{sub 3} and from 10 K to 298 K for Sb{sub 2}Te{sub 3}. The EXAFS technique for studying the local structure of the two compounds was conducted from 19 K to 298 K. Bi{sub 2}Te{sub 3} and Sb{sub 2}Te{sub 3} are isostructural, with a space group of R3{sup ¯}m. The structure consists of repeated quintuple layers of atoms, Te2-M-Te1-M-Te2 (where M = Bi or Sb) stacking along the c-axis of the unit cell. EXAFS was used to examine the bond distances and static and thermal disorders for the first three shells of Bi{sub 2}Te{sub 3} and Sb{sub 2}Te{sub 3} as a function of temperature. The temperature dependencies of thermal disorders were analyzed using the Debye and Einstein models for lattice vibrations. The Debye and Einstein temperatures for the first two shells of Bi{sub 2}Te{sub 3} are similar to those of Sb{sub 2}Te{sub 3} within the uncertainty in the data. However, the Debye and Einstein temperatures for the third shell of Bi-Bi are significantly lower than those of the third shell of Sb-Sb. The Einstein temperature for the third shell is consistent with a soft phonon mode in both Bi{sub 2}Te{sub 3} and Sb{sub 2}Te{sub 3}. The lower Einstein temperature of Bi-Bi relative to Sb-Sb is consistent with the lower value of thermal conductivity of Bi{sub 2}Te{sub 3} relative to Sb{sub 2}Te{sub 3}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Safety assessment of historical masonry churches based on pre-assigned kinematic limit analysis, FE limit and pushover analyses

This study presents some results of a comprehensive numerical analysis on three masonry churches damaged by the recent Emilia-Romagna (Italy) seismic events occurred in May 2012. The numerical study comprises: (a) pushover analyses conducted with a commercial code, standard nonlinear material models and two different horizontal load distributions; (b) FE kinematic limit analyses performed using a non-commercial software based on a preliminary homogenization of the masonry materials and a subsequent limit analysis with triangular elements and interfaces; (c) kinematic limit analyses conducted in agreement with the Italian code and based on the a-priori assumption of preassigned failure mechanisms, where the masonry material is considered unable to withstand tensile stresses. All models are capable of giving information on the active failure mechanism and the base shear at failure, which, if properly made non-dimensional with the weight of the structure, gives also an indication of the horizontal peak ground acceleration causing the collapse of the church. The results obtained from all three models indicate that the collapse is usually due to the activation of partial mechanisms (apse, façade, lateral walls, etc.). Moreover the horizontal peak ground acceleration associated to the collapse is largely lower than that required in that seismic zone by the Italian code for ordinary buildings. These outcomes highlight that structural upgrading interventions would be extremely beneficial for the considerable reduction of the seismic vulnerability of such kind of historical structures.

42 ENGINEERING↗

Azimuthal anisotropy of the scattered radiation in grazing incidence X-ray fluorescence

The Compton and elastic scattering radiations are the major contributor to the spectral background of an x-ray fluorescence spectrum, which eventually limits the element detection sensitivities of the technique to µg/g (ppm) range. In the present work, we provide a detail mathematical descriptions and show that how polarization properties of the synchrotron radiation influence the spectral background in the x-ray fluorescence technique. We demonstrate our theoretical understandings through experimental observations using total x-ray fluorescence measurements on standard reference materials. Interestingly, the azimuthal anisotropy of the scattered radiation is shown to have a vital role on the significance of the x-ray fluorescence detection sensitivities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local phonon mode in thermoelectric Bi{sub 2}Te{sub 2}Se from charge neutral antisites

Local modes caused by defects play a significant role in the thermal transport properties of thermoelectrics. Of particular interest are charge-neutral defects that suppress thermal conductivity, without significantly reducing electrical transport. Here, we report a temperature dependent Raman study that identifies such a mode in a standard thermoelectric material, Bi{sub 2}Te{sub 2}Se. One of the modes observed, whose origin has been debated for decades, was shown most likely to be an antisite defect induced local mode. The anomalous temperature independent broadening of the local mode is ascribed to the random arrangement of Se atoms. The temperature renormalization of all modes is well explained by an anharmonic model–Klemens's model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal expansion of LaB 6 from 298 to 998 K

We propose LaB 6 as a temperature calibration standard for high-temperature (HT) X-ray diffractometry owing to its high temperature stability. Such HT applications require a reliable HT lattice parameter or, equivalently, peak position data, which have not been readily accessible to the diffraction community to date. As such, the thermal expansion behavior of NIST SRM 660a LaB6 was assessed in the temperature range 298–998 K using HT Bragg–Brentano parafocusing θ:θ X-ray diffractometry in conjunction with Rietveld analysis. Data were collected in the 2θ range 20–150° at a data collection rate of 0.5° θ min −1 in air and at 1 atm. The temperature was stepped in 50 K increments. The cubic unit-cell lattice parameter [a(T)] of LaB 6 in Å was found to vary as a(T) = 4.15678 (±0.00001) + Ξ(T − 298 K) + Ψ(T − 298 K) 2 , where Ξ = 2.4645 × 10 −5 (±4.8904 × 10 −8 ) Å K −1 and Ψ = 1.0325 × 10 −8 (±6.7376 × 10 −11 ) Å K −1 . The isobaric volume thermal expansion coefficient (TEC) was obtained as α V P = (5.9291 × 10 −6 ) + (4.9680 × 10 −9 )(T − 298 K) K −1 , from which the corresponding linear TEC was obtained as α L P = (1.9764 × 10 −6 ) + (1.6560 × 10 −9 )(T − 298 K) K −1 . The 3 × 3 matrix representations of the single-crystal isobaric linear TEC and the volume expansivity were obtained for the cubic crystal class to which LaB 6 belongs. Also, the temperature dependence of the lattice parameter data of this study was compared with past landmark studies on LaB 6 by Dutchak et al. [Inorg. Mater. (1972), 8, 1877–1880] and Aivazov et al. [Inorg. Mater. (1979), 15, 1015–1016].

LaB6 standard material↗

Microbial processing of plant remains is co-limited by multiple nutrients in global grasslands

Microbial processing of aggregate-unprotected organic matter inputs is key for soil fertility, long-term ecosystem carbon and nutrient sequestration and sustainable agriculture. In this work, we investigated the effects of adding multiple nutrients (nitrogen, phosphorus and potassium plus nine essential macro- and micro-nutrients) on decomposition and biochemical transformation of standard plant materials buried in 21 grasslands from four continents. Addition of multiple nutrients weakly but consistently increased decomposition and biochemical transformation of plant remains during the peak-season, concurrent with changes in microbial exoenzymatic activity. Higher mean annual precipitation and lower mean annual temperature were the main climatic drivers of higher decomposition rates, while biochemical transformation of plant remains was negatively related to temperature of the wettest quarter. Nutrients enhanced decomposition most at cool, high rainfall sites, indicating that in a warmer and drier future fertilized grassland soils will have an even more limited potential for microbial processing of plant remains.

59 BASIC BIOLOGICAL SCIENCES↗

In Situ Oxygen Isotope Determination in Serpentine Minerals by SIMS: Addressing Matrix Effects and Providing New Insights on Serpentinisation at Hole BA1B (Samail ophiolite, Oman)

The ability to constrain the petrogenesis of multiple serpentine generations recorded at the microscale is crucial for estimating the extent and conditions of modern versus fossil serpentinisation in ophiolites. To address matrix bias effects during oxygen isotope analysis by SIMS, we present the first investigation analysing antigorite in the compositional range Mg# = 77.5–99.5 mole %, using a CAMECA IMS–1280 secondary ion mass spectrometer. Spot–to–spot homogeneity is ≤ 0.5‰ (2s) for the new antigorite reference materials. The relative bias between antigorite reference materials with different Mg/Fe ratios is described by a second order polynomial, and a maximum difference in bias of ~ 1.8‰ was measured for Mg# ~ 78 to 100. We observed a bias up to ~ 1.0‰ between lizardite and antigorite attributed to their different crystal structure. Orientation effects up to ~ 1‰ were observed in chrysotile. The new analytical protocol allowed the identification of oxygen isotope zoning up to ~ 7‰ in serpentine minerals from two serpentinites recovered from an area of active serpentinisation in the Samail ophiolite. Furthermore in situ analysis is capable of resolving isotopic heterogeneity that may directly reflect changes in the physical and chemical conditions of multiple serpentinisation events in the Samail ophiolite.

47 OTHER INSTRUMENTATION↗

Ultra-trace determination of Strontium-90 in environmental soil samples from Qatar by collision/reaction cell-inductively coupled plasma mass spectrometry (CRC-ICP-MS/MS)

Because of the very low level of {sup 90}Sr in the environmental soil samples and its determination by beta counting may take several weeks, we developed a procedure for ultra-trace determination of {sup 90}Sr using collision reaction cell-inductively coupled plasma tandem mass spectrometry (CRC-ICP-MS/MS, Agilent 8800). Soil samples were dried at 105 deg. C and then heated in a furnace at 550 deg. C to remove any organics present. 500 g of each soil samples were aliquoted into 2000 ml glass beakers. Each Soils samples were soaked in 2 ppm Sr solution carrier to allow determination of chemical yield. The solid to liquid ratio was 1:1. Finally the soil samples were dried at 105 deg. C. Five hundred milliliters concentrated nitric acid and 250 ml hydrochloric acid volumes were added on 500 g soil samples. The samples were digested on hot plate at 80 deg. C to prevent spraying with continuous manual mixing. The leachate solution was separated. The solids were rinsed with 500 ml deionized water, warmed on a hot plate and the leachate plus previous leachate were filtered and the total volume was reduced to 500 ml by evaporation. Final leachate volume was transferred to a centrifuge tubes. The centrifuge tubes were centrifuged at 3,500 rpm for 10 min. The leachate was transferred to a 1 L beaker and heated on a hot plate to evaporate the leachate to dryness. The reside was re-dissolved in 100 ml of 2% HNO{sub 3} and reduced by evaporation to 10 mL. The solution was measured directly by CRC-ICP-MS/MS by setting the first quadruple analyzer to m/z 90 and introducing oxygen gas into the reaction cell for elimination isobar interference from zirconium-90. The method was validated by measurements of standard reference materials and applied on environmental soil samples. The overall time requirement for the measurement of strontium-90 by CRC-ICP-MS/MS is 2 days, significantly shorter than any radioanalytical protocol currently available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-CD-207B-11: Multi-Vendor Phantom Study of CT Lung Density Metrics: Is a Reproducibility of Less Than 1 HU Achievable?

Purpose: To standardize the calibration procedures of CT lung density measurements using low-density reference foams in a phantom, and to demonstrate a reproducibility of less than 1 HU for lung equivalent foam densities measured across CT vendor platforms and protocols. Methods: A phantom study was conducted on CT scanner models from 4 vendors at 100, 120, and 135/140 kVp and 1.5, 3, and 6 mGy dose settings, using a lung density phantom containing air, water, and 3 reference foams (indirectly calibrated) with discrete densities simulating a 5-cm slice of the human chest. Customized segmentation software was used to analyze the images and generate a mean HU and variance for each of the density for the 22 vendor/protocols. A 3-step calibration process was devised to remove a scanner-dependent parameter using linear regression of the HU value vs the relative electron density. The results were mapped to a single energy (80 keV) for final comparison. Results: The heterogeneity across vendor platforms for each density assessed by a random effects model was reduced by 50% after re-calibration, while the standard deviation of the mean HU values also improved by about the same amount. The 95% CI of the final HU value was within +/−1 HU for all 3 reference foam densities. For the backing lung foam in the phantom (served as an “unknown”), this CI is +/− 1.6 HU. The kVp and dose settings did not appear to have significant contributions to the variability. Conclusion: With the proposed calibration procedures, the inter-scanner reproducibility of better than 1 HU is demonstrated in the current phantom study for the reference foam densities, but not yet achieved for a test density. The sources of error are being investigated in the next round of scanning with a certified Standard Reference Material for direct calibration. Fain: research funding from GE Healthcare to develop pulmonary MRI techniques. Hoppel: employee of Toshiba Medical Research Institute USA/financial interest with GE Healthcare. M. Fuld: employee of Siemens Healthcare for medical device equipment and software. This project is supported partially by RSNA QIBA Concept Award (Fain), NIH/NIBIB, HHSN268201300071C (Y).

60 APPLIED LIFE SCIENCES↗

Algorithms in Diffraction Profile Analysis

This chapter introduces several approaches to crystallographic structure refinement from diffraction profile data including the Rietveld method, global optimization methods, and Bayesian modeling. First, the Rietveld method and related nonlinear least squares approaches to analyzing diffraction profiles are briefly discussed. We then review the most common algorithms within global optimization as alternative methods of structure solution: grid search, simulated annealing, and genetic algorithms. As the Rietveld method is the standard tool for analyzing diffraction profile data, we catalogue its challenges and limitations. A Bayesian approach to diffraction profile analysis is presented as an alternative, along with several sampling algorithms including Gibbs sampling, variants of Metropolis sampling, Hamiltonian Monte Carlo, and approximate Bayesian computing. These sampling algorithms are applied to the fitting of a neutron diffraction profile from a National Institute of Standards and Technology silicon standard reference material, and their results are compared.

Singh, Susheela↗

Radiative cooling textiles using industry-standard particle-free nonporous micro-structured fibers

Abstract Thermal radiation is a major dissipative pathway for heat generated by the human body and offers a significant thermoregulation mechanism over a wide range of conditions. We could use this in garment design to enhance personal cooling, which can improve the wearing comfort of garments or even result in energy savings in buildings. At present, however, radiative cooling has received insufficient attention in commercial design and production of textiles for wearable garments. Textiles that efficiently transmit the radiative heat were recently demonstrated, but either do not utilize standard weaving and knitting processes for wearable garments or require substantial process modifications. Here, we demonstrate the design and implementation of large-scale radiative cooling textiles for localized cooling management and enhanced thermal comfort using industry-standard particle-free nonporous micro-structured fibers that are fully compatible with standard textile materials and production methods. The micro-structured fibers, yarns and fabrics are part of a hierarchical photonic structure design that renders the textiles highly infrared transparent (up to > 0.8) while assuring visual opacity (up to 0.99). We design radiative cooling textiles with first-principles electromagnetic methods and fabricate them using commercial textile materials and formation facilities. Our “fabless” approach is confirmed by very good quantitative agreement between design and measurements. The resulting fabrics exhibit wearability properties expected of wearable textiles, and lower skin temperature by ≥ 3 °C compared to conventional textiles, which offers the potential for > 30 % energy savings in buildings and increases wearing comfort by significantly reducing the reliance on latent heat dissipation for thermoregulation.

Catrysse, Peter B.↗

Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report

A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on the SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.

Fire Safety↗

Analysis of dose rates to O-ring and membrane for SAVY-4000 container

New generation standard nuclear material containers (NG SNMC aka SAVY 4000) have been designed for storage of various actinide materials whose specific activity is less than or equal to that of heat source plutonium (13.4 Ci/g). The containers also have a limiting decay heat of 25 W. The objective of this analysis is to determine the maximum absorbed dose rate delivered to the Viton o-ring and to the Teflon filter membrane located in the container’s lid under these activity and decay heat constraints. Previous analysis conducted in 2011 showed that the dose rate to the o-ring is higher for the 1-Quart container as compared to the 3-Quart container for the maximum material loading at the density of 3 g cm -3 for all material compositions studied given the size constraints of each container. Ratios of dose rates to the o-ring for the 1-Quart container as compared to the 3-Quart container are summarized in Table 1. In addition, the dose rate to the Teflon filter membrane is 3.4 times higher for the 1-Quart container with MT52+Am as compared to the 3-Quart container with MT52+Am. Thus only the 1-Quart container is analyzed in this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Source Recertification, Refurbishment, and Transfer Logistics

The 2012 Gap Analysis of Department of Energy Radiological Sealed Sources, Standards, and Materials for Safeguards Technology Development report, and the subsequent Reconciliation of Source Needs and Surpluses across the U.S. Department of Energy National Laboratory Complex report, resulted in the identification of 33 requests for nuclear or radiological sealed sources for which there was potentially available, suitable material from within the U.S. Department of Energy (DOE) complex to fill the source need. Available, suitable material was defined by DOE laboratories as material slated for excess, or that required recertification or refurbishment before being used for safeguards technology development. This report begins by outlining the logistical considerations required for the shipment of nuclear and radiological materials between DOE laboratories. Then, because of the limited need for transfer of matching sources, the report also offers considerations for an alternative approach – the shipment of safeguards equipment between DOE laboratories or technology testing centers. Finally, this report addresses repackaging needs for the two source requests for which there was available, suitable material within the DOE complex.

Logistics↗

Testing of Alternative Abrasives for Water-Jet Cutting at C Tank Farm

Legacy waste from defense-related activities at the Hanford Site has predominantly been stored in underground tanks, some of which have leaked; others may be at risk to do so. The U.S. Department of Energy’s goal is to empty the tanks and transform their contents into more stable waste forms. To do so requires breaking up, and creating a slurry from, solid wastes in the bottoms of the tanks. A technology developed for this purpose is the Mobile Arm Retrieval System. This system is being used at some of the older single shell tanks at C tank farm. As originally planned, access ports for the Mobile Arm Retrieval System were to be cut using a high- pressure water-jet cutter. However, water alone was found to be insufficient to allow effective cutting of the steel-reinforced tank lids, especially when cutting the steel reinforcing bar (“rebar”). The abrasive added in cutting the hole in Tank C-107 was garnet, a complex natural aluminosilicate. The hardness of garnet (Mohs hardness ranging from H 6.5 to 7.5) exceeds that of solids currently in the tanks, and was regarded to be a threat to Hanford Waste Treatment and Immobilization Plant systems. Olivine, an iron-magnesium silicate that is nearly as hard as garnet (H 6.5 to 7), has been proposed as an alternative to garnet. Pacific Northwest National Laboratory proposed to test pyrite (FeS 2 ), whose hardness is slightly less (H 6 to 6.5) for 1) cutting effectiveness, and 2) propensity to dissolve (or disintegrate by chemical reaction) in chemical conditions similar to those of tank waste solutions. Cutting experiments were conducted using an air abrader system and a National Institute of Standards and Technology Standard Reference Material (SRM 1767 Low Alloy Steel), which was used as a surrogate for rebar. The cutting efficacy of pyrite was compared with that of garnet and olivine in identical size fractions. Garnet was found to be most effective in removing steel from the target; olivine and pyrite were less effective, but about equal to each other. The reactivity of pyrite, compared to olivine and garnet, was studied in high-pH, simulated tank waste solutions in a series of bench-top experiments. Variations in temperature, degree of agitation, grain size, exposure to air, and presence of nitrate and nitrite were also studied. Olivine and garnet showed no sign of dissolution or other reaction. Pyrite was shown to react with the fluids in even its coarsest variation (150-1000 μm). Projected times to total dissolution for most experiments range from months to ca. 12 years, and the strongest control on reaction rate is the grain size.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗