Development of an Adaptive Droop Control Method for Interconnected Lunar DC Microgrids Using Power Hardware-in-the-Loop

NASA’s Artemis Program outlines the need for a habitat capable of sustaining human life as well as mining and producing raw materials on the lunar surface. This mission is viewed as a means towards deeper space exploration, with plans for reaching Mars and beyond. Human presence on the moon is not possible without the ability to generate and distribute energy, namely electricity, through a network of energy sources, loads, and power converters called a microgrid. Multiple microgrids can be deployed on the moon based on location and need. Separate microgrids will require interconnection to increase resiliency and reliability given the mission’s high criticality. A method for adaptive control over power converters connecting two dc microgrids is proposed. A simulation is modeled after the lunar power system with two approaches to power converter droop control, allowing for a more flexible and adaptive microgrid architecture. Further experiments are conducted using the control methods in a power hardware-in-the-loop test environment to study the performance of hardware converter control used in this application.

dc microgrid↗

Thermion: Verification of a thermionic heat pipe in microgravity

The Idaho National Engineering Laboratory (INEL) is conducting intensive research in the design and development of a small excore heat-pipe-thermionic space nuclear reactor power system (SEHPTR). The SEHPTR spacecraft will be able to supply 40 kW of power in any given orbit. The key components in this reactor are the thermionic heat pipes. The heat pipes have two major functions: (1) to convert heat energy into electrical energy, and (2) to radiate the excess heat to space. Thermionic power conversion is the process of converting heat energy into electrical energy with no moving parts. Heat is applied to the cathode surface. This heat will boil off electrons that will jump across the gap to the cooler surface of the anode, which will cause a potential difference between the two plates and induce a current through the load. Thermionic power conversion is incorporated as part of the heat pipe. The heat pipe, which is being developed by Thermacore Inc., is actually two heat pipes. It uses a radial heat pipe, called the emitter, and an axial heat pipe collector. The emitter heat pipe will pass the heat from the nuclear core to the cathode surface. The collector heat pipe keeps the anode surface cooler by transferring the heat from the anode surface and radiating it to space.

Source record↗

Microgrid for Lunar Surface Power

Sustained lunar surface operations will require access to continuous and highly reliable power to support mission needs and an ability to evolve and grow over time (years). The first initial loads that arrive on the lunar surface will contain their own dedicated power sources. Over time, as the lunar surface operations and power demands grow, these individual power loads will require more power than can be generated with any single power device. This demand drives the need for inter-connecting loads and power devices to share power between them, resulting in a micro-grid. One advantage of developing a lunar surface micro-grid is that it will allow lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient and required. The micro-grid concept also provides another benefit of affording the ability to increase overall system reliability by integrating dissimilar power generation and energy storage devices together, for example modifying the power generation strategy to include both solar arrays and nuclear. This talk provides an overview of NASA’s interest in developing a lunar microgrid and provides areas where external entities can play a role in developing futuristic power needs.

Jeffrey Csank↗

Artificial Intelligence Techniques in Smart Grid: A Survey

The smart grid is enabling the collection of massive amounts of high-dimensional and multi-type data about the electric power grid operations, by integrating advanced metering infrastructure, control technologies, and communication technologies. However, the traditional modeling, optimization, and control technologies have many limitations in processing the data; thus, the applications of artificial intelligence (AI) techniques in the smart grid are becoming more apparent. This survey presents a structured review of the existing research into some common AI techniques applied to load forecasting, power grid stability assessment, faults detection, and security problems in the smart grid and power systems. It also provides further research challenges for applying AI technologies to realize truly smart grid systems. Finally, this survey presents opportunities of applying AI to smart grid problems. The paper concludes that the applications of AI techniques can enhance and improve the reliability and resilience of smart grid systems.

energy systems↗

Power Management Solution for Growing Loads at Airport Rental Facilities

Growing electrical loads across airport facilities could expand beyond local grid capacities. Coordinating flexible loads with generation and storage assets can reduce coincident peaks, mitigate costly upgrades, and reduce electricity costs. This report outlines how The Athena Team has developed a suite of tools, resources, and solutions to leverage load flexibility with energy assets to harness this value potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research on stability and uniformity of multi-wavelength Brillouin-erbium fiber laser based on FWM

In this paper, we experimentally and theoretically investigate the stability and uniformity of multi-wavelength Brillouin-erbium fiber laser based on four-wave mixing (FWM). Multi-wavelength generation is limited by cross-gain saturation between different wavelengths from homogeneous broadening of erbium-doped fiber. Modeling coupled-mode equation for FWM and analyzing the influence of FWM on multi-wavelength generation. 16 orders Brillouin Stokes (BS) waves with a wavelength spacing of 0.084 nm are obtained experimentally within a 3 dB bandwidth by the FWM effect in a 100 m highly nonlinear fiber (HNLF), power distribution of each laser is uniform and peak power fluctuation is less than 1.184 dB within a 10 dB bandwidth, the outputs exhibit good time stability and uniformity. Compared with the same configuration, the laser without HNLF has only 9 orders stable BS waves within 3 dB bandwidth, and high-order Stokes wave shows significant waveform jitter and power fluctuation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fuel cell powerplant operation in Apollo spacecraft.

Primary electrical power for loads in the Apollo Command and Service Modules is furnished by a system of three fuel cell powerplants. The powerplants convert cryogenic hydrogen and oxygen into direct current. Water formed in the fuel cell reactions is supplied to the spacecraft for crew use. Waste heat is rejected through a coolant loop to a spacecraft radiator. The ability of the fuel cell to meet its voltage-power requirements and to control its own operating temperature under the environmental extremes of launch, ascent, earth orbit, translunar flight, and lunar orbit was demonstrated on successively more difficult missions leading up to the first lunar landing.

Ching, A. C.↗

Physics-Informed Sparse Gaussian Process for Probabilistic Stability Analysis of Large-Scale Power System with Dynamic PVs and Loads

This work proposes a physics-informed sparse Gaussian process (SGP) for probabilistic stability assessment of large-scale power systems in the presence of uncertain dynamic PVs and loads. The differential and algebraic equations considering uncertainties from dynamic PVs and loads are reformulated to a nonlinear mapping relationship that allows the application of SGP. Thanks to the nonparametric characteristic of Gaussian process, the proposed framework does not require distributions of uncertain inputs and this distinguishes it from existing approaches. As the original Gaussian process is not scalable to large-scale systems with high dimensional uncertain inputs, this paper develops the SGP with a stochastic variational inference technique. It leads to approximately two orders of complex reduction. A data pre-processing step is also introduced to tackle the coexistence of stable and unstable cases by sample clustering and constructing separate SGPs. The probabilistic transient stability index is analyzed to assess system stability under different uncertain dynamics loads and PVs. Comparisons are performed with the sampling-based, the polynomial chaos expansion-based, and traditional Gaussian process-based methods on the modified IEEE 118-bus and Texas 2000-bus systems under various scenarios, including different levels of uncertainties and the existence of nonlinear correlations among dynamic PVs. The impacts of data quality and quantity issues are also investigated. It is shown that the proposed SGP achieves significantly improved computational efficiency while maintaining high accuracy with a limited number of data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Generation and Load Forecasting for Adjuntas PR Community Microgrids

Existing frameworks to forecast time-series photovoltaic (PV) output power and consumer load for microgrid operations and controls assume a near-continuous availability of real-time input features from the field assets such as PV inverters, energy meters, and weather station. These incoming data points are used to periodically retrain models and update forecast snapshots over a moving horizon window, be it one hour-ahead, one-day ahead, or one-week ahead. However, such frameworks are not resilient to disruptions in data availability caused by losses in communications between the field sensors and data loggers. Hence, there is a need for programs that assume no availability of real-time microgrid asset data and still make reliable forecasts that can be used for decision-making. Such programs would be apt to function in extreme weather events such as hurricanes and would use lightweight recursive time-series models to independently forecast solar irradiance and ambient temperature, then compute PV power from those forecasts, as well as independently forecast consumer load. The codebase performs forecasting for the scenario of when the microgrid does not have a reliable access to forecasts or real-time observations of solar irradiance (I) and ambient temperature (AT) and load (Load) to be able to adequately forecast, in real-time, the PV power production or a business' load. In this case, using historical values of PV power and load, a univariate forecasting of generation and consumption are respectively made. The use-case in particular has two sub-scenarios: one, a normal 7-day ahead forecast where the unavailability of real-time data is assumed due to infrastructure issues such as loss of communication or sensor maintenance or service downtimes. Whereas a hurricane-caused unavailability of real-time data requires a second model trained specifically on historical hurricane days to be able to capture the extreme day behavior of generation in particular, and load if applicable. A gradient boosted regression tree comprises an ensemble of additive models that map between the input of historical values (be it irradiance, temperature, or load) and their corresponding output forecasts of a given horizon such that the individual learner predictions are summed up over the total number of such learners in the ensemble to produce an aggregate forecast. A weighting mechanism is applied to the training data in each iteration, where actual and forecast values are compared to penalize incorrect forecasts by increasing the weight and reducing it to reward correct forecasts. The code's benefits are that it: (a) accounts for a contingency where communication loss renders newly measured real-time data unavailable for model tuning and snapshot updates; (b) presents blind forecasting that recursively determines the next time-step value in a horizon using the forecast of the same attribute from a prior step; and (c) employs lightweight models that, once trained, can reliably generalize for different horizons, which make them suitable for enhancing the resilience of field microgrids prone to extreme events that encounter disruptions to data availability.

Sundararajan, Aditya [Oak Ridge National Laborator↗

Review of wake management techniques for wind turbines

Summary The progression of wind turbine technology has led to wind turbines being incredibly optimized machines often approaching their theoretical maximum production capabilities. When placed together in arrays to make wind farms, however, they are subject to wake interference that greatly reduces downstream turbines' power production, increases structural loading and maintenance, reduces their lifetimes, and ultimately increases the levelized cost of energy. Development of techniques to manage wakes and operate larger and larger arrays of turbines more efficiently is now a crucial field of research. Herein, four wake management techniques in various states of development are reviewed. These include axial induction control, wake steering, the latter two combined, and active wake control. Each of these is reviewed in terms of its control strategies and use for power maximization, load reduction, and ancillary services. By evaluating existing research, several directions for future research are suggested.

17 WIND ENERGY↗

EVs@Scale: NextGen Profiles EVSE Characterization 2025

As part of the U.S. DOE EVs@Scale consortium, the Next-Generation Profiles (NextGen Profiles [NGP]) project presents analysis and results from the characterization of high-power conductive and wireless charging infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. Electric Vehicle Service Equipment (EVSE) characterization involves testing over a wide range of DC charging currents and voltages during nominal and off-nominal conditions. This testing allows for a better understanding of the impact that high-power charging will have on the electric grid. A common set of standard test plans, procedures, and data requirements were applied to the characterization in this document with minor updates and improvements. This report covers all conductive characterization activities performed between October 2024 and September 2025 on the Delta Electronics 350KW Electric Vehicle Charging System, consisting of power cabinet model EIDN-U350KTA01 and dispenser model EIDD-U350SSUUAEG-350.Key Findings include: Output regulation, Efficiency and power factor, Load management, Grid Resilience, Smart Charge Management (SCM) performance, Thermal control system performance, Multi-port simultaneous charging performance, and Selected performance comparisons with other EVSEs characterized in the NextGen Profiles project. Hot and cold temperature testing was not conducted on the Delta 350KW due to laboratory limitations. Future research could include continued testing the Delta hardware under off-nominal temperature conditions including multi-port/multi-session simultaneous charge testing, in addition to collecting data on other high-power conductive chargers to augment.

25 ENERGY STORAGE↗

High Performance Computing Peak Shaving for Microreactor Operation

There are multiple nuclear microreactors currently under development that are designed to provide autonomous power for as many as ten or more years without refueling and are designed to power high performance computing (HPC) datacenters. But the load-follow speeds for a nuclear microreactor will be much slower than grid power and slower than the power variance typical of a HPC system. HPC datacenters experience peak power load variance driven by several factors ranging from the operation of cooling systems to remove heat from the servers to supporting a wide range of user application workflows and architectures each with different power signatures. One mechanism to support the limited load-follow of a microreactor is peak shaving where an energy storage mechanism is used to shed peak load and reduce significant power variance. This work explores peak electrical load shaving using uninterruptible power supply (UPS) systems designed for HPC support in the context of peak shaving when operating using a nuclear microreactor with a load-follow limited to 10% of load per minute. Using a self contained HPC datacenter complete with stand-alone cooling system and provisioned with an x86 cluster, an ARM cluster, and a graphics processing unit (GPU) cluster, peak shaving for microreactor operation using the UPS battery backup is explored while running two classes of typical HPC user applications. HPC architecture suitability for microreactor operation under this type of peak shaving is examined.

97 MATHEMATICS AND COMPUTING↗

Economic viability of using thermal energy storage for flexible carbon capture on natural gas power plants

Fossil fuel-based power plants generate 80% of the electricity in the United States and provide a reliable generation source for both base and peak power demands. These plants are expected to adapt to changes in environmental policies that will require carbon management with carbon capture and storage (CCS) representing a possible solution. Current solvent-based CCS has a detrimental impact on a power plant's performance due to large heat loads required for carbon capture solvent regeneration. This parasitic load restricts the power plant's output and operation flexibility. Therefore, this study evaluates the feasibility of using thermal storage technologies for natural gas combined cycle (NGCC) power plants coupled with CCS to minimize the impact of solvent regeneration and enable the plant to operate at peak power output. Thermal storage can minimize the impact of CCS on the power plant by providing the heat load required for solvent regeneration during times of peak demand which will allow the plant to operate unrestricted and at full power. In total, fifteen unique thermal storage configurations were evaluated from three thermal storage categories: Brayton cycle heat pump, vapor compression heat pump, and heat recovery steam generator steam extraction for storage. The viability of these systems was determined by evaluating each configuration on thousands of real-world Locational Marginal Pricing (LMP) profiles from the New York Independent System Operator and California Independent System Operator electricity markets using a techno-economic analysis. Afterwards, results were compared to the performance of a base power plant (NGCC with CCS and no thermal storage) to determine the impact of thermal storage on power plant economics. Overall, six of the thermal storage configurations performed better than base CCS enabled power plant on between 11.5% and 38.7% of the LMP signals evaluated. The best performing configuration was a vapor compression heat pump that used flue gas as the working fluid and had both hot and cold thermal storage units. This configuration performed better than the base CCS power plant on 38.7% of the LMP profiles. The results of this study show thermal storage can mitigate the economic impact of carbon capture solvent regeneration on NGCC power plants. Discussion focuses on the impact of electricity pricing on the optimal thermal storage system, the advantages and disadvantages of the systems evaluated, and identifies limitations with the study.

25 ENERGY STORAGE↗

Spacecraft power system architecture to mitigate spacecraft charging effects

A power system architecture for a spacecraft and a method of a power supply for a spacecraft are presented which take advantage of the reduced plasma interaction associated with positive ground high voltage photovoltaic arrays and provide a negative ground power supply for electrical loads of the spacecraft. They efficiently convert and regulate power to the load bus and reduce power system mass and complexity. The system and method ground the positive terminal of the solar arrays to the spacecraft hull, and using a power converter to invert the electric sign, permit a negative ground for the electrical distribution bus and electrical components. A number of variations including a load management system and a battery management system having charging and recharging devices are presented.

Manner, David B.↗

Hybrid Power Management-Based Vehicle Architecture

Hybrid Power Management (HPM) is the integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications (s ee figure). The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The basic vehicle architecture consists of a primary power source, and possibly other power sources, that provides all power to a common energy storage system that is used to power the drive motors and vehicle accessory systems. This architecture also provides power as an emergency power system. Each component is independent, permitting it to be optimized for its intended purpose. The key element of HPM is the energy storage system. All generated power is sent to the energy storage system, and all loads derive their power from that system. This can significantly reduce the power requirement of the primary power source, while increasing the vehicle reliability. Ultracapacitors are ideal for an HPM-based energy storage system due to their exceptionally long cycle life, high reliability, high efficiency, high power density, and excellent low-temperature performance. Multiple power sources and multiple loads are easily incorporated into an HPM-based vehicle. A gas turbine is a good primary power source because of its high efficiency, high power density, long life, high reliability, and ability to operate on a wide range of fuels. An HPM controller maintains optimal control over each vehicle component. This flexible operating system can be applied to all vehicles to considerably improve vehicle efficiency, reliability, safety, security, and performance. The HPM-based vehicle architecture has many advantages over conventional vehicle architectures. Ultracapacitors have a much longer cycle life than batteries, which greatly improves system reliability, reduces life-of-system costs, and reduces environmental impact as ultracapacitors will probably never need to be replaced and disposed of. The environmentally safe ultracapacitor components reduce disposal concerns, and their recyclable nature reduces the environmental impact. High ultracapacitor power density provides high power during surges, and the ability to absorb high power during recharging. Ultracapacitors are extremely efficient in capturing recharging energy, are rugged, reliable, maintenance-free, have excellent lowtemperature characteristic, provide consistent performance over time, and promote safety as they can be left indefinitely in a safe, discharged state whereas batteries cannot.

Eichenberg, Dennis J.↗

On-Chip Batteries as Distributed Energy Sources in Heterogeneous 2.5D/3D Integrated Circuits

Energy efficiency in digital systems faces challenges due to the constraints imposed by small-scale transistors. Moreover, the growing demand for portable consumer electronics necessitates the use of compact energy sources. To address these challenges, heterogeneous 3D IC technology has emerged as a promising solution for the former. Regarding the latter, we propose the concept of distributed batteries within a heterogeneous 3D IC. This approach involves utilizing multiple smaller batteries with different specifications among different modules of 3D ICs. This approach optimizes performance and overcomes limitations associated with both 3D ICs and conventional power delivery methods. Distributed batteries play a vital role in effectively managing the heat generated by energy sources and modules within a 3D IC. Furthermore, they contribute to achieving a uniform distribution of heat throughout the entire structure, which ultimately ensures the optimal performance of the batteries and modules. The simulation results indicate a 40 percent enhancement in achieving a more even distribution of generated heat. Additionally, the proposed distributed battery techniques improve power delivery, enhance reliability, and enable optimized voltage regulation while improving efficiency. In addition to the primary benefits, alternative configurations of the proposed approach can offer extra energy storage capacity and act as efficient electromagnetic shields, resulting in an impressive reduction of external electromagnetic noises by 60 dB.

47 OTHER INSTRUMENTATION↗

Single Axis Flywheel IPACS @1300W, 0.8 N-m

NASA Glenn Research Center is developing flywheels for space systems. A single axis laboratory version of an integrated power and attitude control (IPACs) system has been experimentally demonstrated. This is a significant step on the road to a flight qualified three axes IPACS system. The presentation outlines the flywheel development process at NASA GRC, the experimental hardware and approach, the IPACS control algorithm that was formulated and the results of the test program and then proposes a direction for future work. GRC has made progress on flywheel module design in terms of specific energy density and capability through a design and test program resulting in three flywheel module designs. Two of the flywheels are used in the 1D-IPACS experiment with loads and power sources to simulate a satellite power system. The system response is measured in three power modes: charge, discharge, and charge reduction while simultaneously producing a net output torque which could be used for attitude control. Finally, recommendations are made for steps that should be taken to evolve from this laboratory demonstration to a flight like system.

Jansen, Ralph↗

Overload protection system for power inverter

An overload protection system for a power inverter utilized a first circuit for monitoring current to the load from the power inverter to detect an overload and a control circuit to shut off the power inverter, when an overload condition was detected. At the same time, a monitoring current inverter was turned on to deliver current to the load at a very low power level. A second circuit monitored current to the load, from the monitoring current inverter, to hold the power inverter off through the control circuit, until the overload condition was cleared so that the control circuit may be deactivated in order for the power inverter to be restored after the monitoring current inverter is turned off completely.

Nagano, S.↗