Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Field study of group effects on the pullout capacity of “deep” helical piles in sand

This paper presents the results of a field load test program used to investigate group effects on the pullout capacity of single-helix “deep” helical piles/anchors in sand. The high tensile capacity and silent installation of helical piles has given them serious consideration as an alternative to conventional deep foundations and anchors for offshore renewable energy structures. New offshore applications may consider the use of groups of helical piles to resist structural loads. Group interaction effects are known to occur in helical piles, but there is a scarcity of field data on groups in sands under tensile loading. This study involved the installation and load testing of single-helix 152mm diameter round shaft piles and pile groups embedded in sand to depths of 12 and 18 helix diameters below the ground surface. The study was designed to explore the effects of close pile spacing, group configuration (i.e., number of piles), and soil strength (i.e., friction angle) as interpreted from cone penetration test (CPT) resistance. The results showed group efficiencies ranging from about 0.6 to 1.0 at a horizontal spacing of 2 to 3 times the helix diameter in sands with friction angles of about 39° to 44°. The data from this study may also be useful for validation of numerical models for analysis of helical pile group interactions.

Engineering↗

Battery Electrolyte Design for Electric Vertical Takeoff and Landing (eVTOL) Platforms

Here, the development of robust and high-performance battery systems is crucial for the advancement of Electric Vertical Takeoff and Landing (eVTOL) vehicles for urban air mobility. This study evaluates the performance of different lithium-ion battery chemistries under Electric Vertical Takeoff and Landing (eVTOL) load profiles. The actual flight data coupled with physical models is used to create discharge profiles for testing on developed lithium-ion cells for eVTOLs. The performance of a standard liquid electrolyte (1.2 M LiPF 6 in EC:EMC), labeled Gen-2, is benchmarked and compared with a fast-charging electrolyte (1.2 M LiFSI in EC:EMC), labeled XFC. Cell analysis involves the use of various techniques, such as impedance spectroscopy, polarization curves, and capacity retention measurements. Capacity retention is stable for both systems over 500 cycles, but unique discharge capacity trends are observed for different mission segments. During the initial takeoff hover stages, Gen-2 electrolytes experience substantial voltage fade, while XFC electrolytes maintain consistent behavior. In general, the Gen-2 electrolyte demonstrated lower discharge overpotentials and higher decay during cycling compared to the XFC electrolyte. This work highlights the complexity of eVTOL battery behavior and provides insights into battery system design, contributing to the advancement of battery energy storage solutions for urban air mobility.

25 ENERGY STORAGE↗

BeyondPlanck: V. Minimal ADC Corrections for Planck LFI

We describe the correction procedure for Analog-to-Digital Converter (ADC) differential non-linearities (DNL) adopted in the Bayesian end-to-end BEYONDPLANCK analysis framework. This method is nearly identical to that developed for the official Planck Low Frequency Instrument (LFI) Data Processing Center (DPC) analysis, and relies on the binned rms noise profile of each detector data stream. However, rather than building the correction profile directly from the raw rms profile, we first fit a Gaussian to each significant ADC-induced rms decrement, and then derive the corresponding correction model from this smooth model. The main advantage of this approach is that only samples which are significantly affected by ADC DNLs are corrected, as opposed to the DPC approach in which the correction is applied to all samples, filtering out signals not associated with ADC DNLs. The new corrections are only applied to data for which there is a clear detection of the non-linearities, and for which they perform at least comparably with the DPC corrections. Out of a total of 88 LFI data streams (sky and reference load for each of the 44 detectors) we apply the new minimal ADC corrections in 25 cases, and maintain the DPC corrections in 8 cases. All these corrections are applied to 44 or 70 GHz channels, while, as in previous analyses, none of the 30 GHz ADCs show significant evidence of non-linearity. By comparing the BEYONDPLANCK and DPC ADC correction methods, we estimate that the residual ADC uncertainty is about two orders of magnitude below the total noise of both the 44 and 70 GHz channels, and their impact on current cosmological parameter estimation is small. However, we also show that non-idealities in the ADC corrections can generate sharp stripes in the final frequency maps, and these could be important for future joint analyses with the Planck High Frequency Instrument (HFI), Wilkinson Microwave Anisotropy Probe (WMAP), or other datasets. We therefore conclude that, although the existing corrections are adequate for LFI-based cosmological parameter analysis, further work on LFI ADC corrections is still warranted.

79 ASTRONOMY AND ASTROPHYSICS↗

Sizing Considerations for EV Dynamic Wireless Charging Systems with Integrated Energy Storage

Roadways with dynamic wireless charging systems (DWCS) enable charge-sustaining in-motion EV charging, which can reduce charging idle time while increasing range capabilities. Spatially distributed transmitter coils are controlled in response to traffic load that varies significantly minute to minute with high power levels, very short charging time, and low system utilization like wind turbine power. Traffic load estimation and localized analysis may guide effective sizing and topology adoption for feasible and scalable DWCS deployment. DWCS traffic load approximation is reviewed with measured Automated Traffic Recorder (ATR) data and statistical distributions being used to create a synthetic load analyzed using proposed metrics quantifying system utilization over time. Lumped coil section segmentation is compared between second-based distance and spatial density analysis methods, offering 17-27% greater system utilization. A peak load shifting method is proposed for traffic redirection across two tracks with optional BESS integration increasing system utilization by 50-60% depending on time-based and power reserve-based sizing and control.

Lewis, Donovin D.↗

IDAES Enterprise: Generation Expansion Planning with Enhanced Requirements for Capacity Adequacy Under Renewable Intermittency

Achieving net zero carbon emissions likely requires future power systems to integrate new, flexible energy technologies to accommodate higher levels of capacity from variable renewable energy sources. To determine the optimal deployment of new electricity capacity and to study the likelihood of deployments of new energy technologies, an expansion planning model has been developed as part of the IDAES-Enterprise suite of grid models. The Generation Expansion Planning (GEP) model is a multi-period model in which investment decisions occur yearly, and a Unit Commitment (UC) problem is examined on an hourly timescale. To reduce computational complexity of the GEP model, the UC problem is solved for average “representative days” which leaves out extreme, but relatively common, scenarios in which low renewable generation occurs, leaving the system with inadequacy in capacity. The IDAES-Enterprise GEP model has been modified to include these extreme scenarios while keeping the model reasonably tractable. Specifically, a lazy constraint technique was implemented to check for capacity adequacy on an hourly basis over a large data set of aligned load-wind-solar profiles. As a vast majority of the capacity constraints will not be violated, the technique lowers computational expense by searching for violated capacity constraints over an “iterative manner,” adding those infeasible constraints back into the model. Results on a test case of the Southwest Power Pool shows that the lazy constraint technique significantly reduces retirements and increases installments of natural gas combined cycles and flexible natural gas units. It also reduces some retirements of coal units. These modifications provide a more reasonable estimation of required dispatchable power generation capacity to ensure feasibility during peak net load.

Liu, Peng↗

Comparison of aircraft measurements during GoAmazon2014/5 and ACRIDICON-CHUVA

The indirect effect of atmospheric aerosol particles on the Earth's radiation balance remains one of the most uncertain components affecting climate change throughout the industrial period. The large uncertainty is partly due to the incomplete understanding of aerosol–cloud interactions. One objective of the GoAmazon2014/5 and the ACRIDICON (Aerosol, Cloud, Precipitation, and Radiation Interactions and Dynamics of Convective Cloud Systems)-CHUVA (Cloud Processes of the Main Precipitation Systems in Brazil) projects was to understand the influence of emissions from the tropical megacity of Manaus (Brazil) on the surrounding atmospheric environment of the rainforest and to investigate its role in the life cycle of convective clouds. During one of the intensive observation periods (IOPs) in the dry season from 1 September to 10 October 2014, comprehensive measurements of trace gases and aerosol properties were carried out at several ground sites. In a coordinated way, the advanced suites of sophisticated in situ instruments were deployed aboard both the US Department of Energy Gulfstream-1 (G1) aircraft and the German High Altitude and Long-Range Research Aircraft (HALO) during three coordinated flights on 9 and 21 September and 1 October. Here, we report on the comparison of measurements collected by the two aircraft during these three flights. Such comparisons are challenging but essential for assessing the data quality from the individual platforms and quantifying their uncertainty sources. Similar instruments mounted on the G1 and HALO collected vertical profile measurements of aerosol particle number concentrations and size distribution, cloud condensation nuclei concentrations, ozone and carbon monoxide mixing ratios, cloud droplet size distributions, and downward solar irradiance. We find that the above measurements from the two aircraft agreed within the measurement uncertainties. The relative fraction of the aerosol chemical composition measured by instruments on HALO agreed with the corresponding G1 data, although the total mass loadings only have a good agreement at high altitudes. Furthermore, possible causes of the discrepancies between measurements on the G1 and HALO are examined in this paper. Based on these results, criteria for meaningful aircraft measurement comparisons are discussed.

47 OTHER INSTRUMENTATION↗

Supply Chain for Photovoltaics in the United States: 2024 in Review

Solar photovoltaic (PV) and battery energy storage system (BESS) technologies are two immediately available options for meeting U.S. electricity demands, which are increasing due to expansion of loads from end uses including data centers, buildings, vehicles, and factories. Globally, PV and BESS supply chains are dominated by products manufactured in China and elsewhere by Chinese companies. However, U.S. PV and BESS manufacturing have recently grown, with some capacity in each step of the PV supply chain, albeit not enough to currently meet demand with domestic manufacturing alone. This study analyzes U.S. PV supply chains and costs in 2024, for the crystalline silicon and cadmium telluride module supply chains. The full report additionally addresses the PV balance of system, inverter and BESS supply chains. The study concludes with an analysis of technology installation trends, government support for domestic manufacturing, manufacturing jobs, and the domestic content of PV systems installed in the United States in 2024.

14 SOLAR ENERGY↗

An Approach to Data Management Planning for Protected Data Projects

This report describes what is required in a data management plan for data that needs to be protected in some fashion. Here we provide an overview of what a data manager should consider, including the data ingestion and various extract-transform-load processes, metadata considerations and documentation, to what might need to be accounted for in the event of data loss. In addition, this report includes two appendices: forms that, when filled out, make the user compliant with DOE data management requirements as well as additional requirements for handling protected data at ORNL.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Enhanced Hanford Low-Activity Waste Glass Property Data Development: Phase 2

The U.S. Department of Energy’s (DOE) Office of River Protection (ORP) requested Pacific Northwest National Laboratory (PNNL) to support the River Protection Project vitrification in an effort to support operations upon completion of startup activities (DOE 2012). This work was performed under the PNNL project titled “ORP Glass Support Work.” One task of this project—Enhanced Hanford Waste Glass Models—is the subject of this report. A previous task focused on generating property-composition data and models for the Hanford site low-activity waste (LAW) glasses with lower waste loadings, which are relevant to the commissioning of the LAW vitrification facility. The current task has the long-term objective of expanding the Hanford site LAW glass database and property composition models for the balance of the Hanford site tank waste treatment and immobilization mission. During the balance of the mission, LAW glasses with higher waste loadings will be produced. This report presents the glass compositions and glass property data developed in Phase 2 of the enhanced Hanford LAW glass property data development effort. When this effort is complete, enhanced LAW glass property models will be developed. Section 1.1 summarizes the status of the LAW glass composition regions and waste loading constraints prior to the data development effort documented in this report. Section 1.2 summarizes the LAW Phase 2 glass composition region and test matrix. Section 1.3 documents the quality assurance program used in performing the work discussed in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Boundary Microgrids Under Privatization Considerations

Microgrids have physical, electrical, and logical (data, network, and ownership) boundaries. To power unserved customer loads during an outage, microgrids can extend the traditional operational boundaries. This can become complex when considering microgrid-to-microgrid (M2M) interactions where sensitive information such as competitive microgrid operational data is not shared. This work proposes an optimization method coordinated between microgrid controllers and distribution management systems that limits data sharing. The method involves a competitive bidding strategy that maximizes unserved load coverage while minimizing resource utilization and sensitive operational data sharing among entities. The work is validated on a two-microgrid system with photovoltaic and energy storage systems and curves of load derived from real world residential buildings datasets. Results show that the proposed method, when applied for three distinct use cases of energy storage sufficiency to cover the predefined boundary and/or the expanded boundary, can successfully select and bid the available load coverage.

Starke, Michael [ORNL] (ORCID:0000000221211195)↗

CoREC: Scalable and Resilient In-memory Data Staging for In-situ Workflows

The dramatic increase in the scale of current and planned high-end HPC systems is leading new challenges, such as the growing costs of data movement and IO, and the reduced mean time between failures (MTBF) of system components. In-situ workflows, i.e., executing the entire application workflows on the HPC system, have emerged as an attractive approach to address data-related challenges by moving computations closer to the data, and staging-based frameworks have been effectively used to support in-situ workflows at scale. However, the resilience of these staging-based solutions has not been addressed, and they remain susceptible to expensive data failures. Furthermore, naive use of data resilience techniques such as n-way replication and erasure codes can impact latency and/or result in significant storage overheads. In this article, we present CoREC, a scalable and resilient in-memory data staging runtime for large-scale in-situ workflows. CoREC uses a novel hybrid approach that combines dynamic replication with erasure coding based on data access patterns. It also leverages multiple levels of replications and erasure coding to support diverse data resiliency requirements. Furthermore, the article presents optimizations for load balancing and conflict-avoiding encoding, and a low overhead, lazy data recovery scheme. We have implemented the CoREC runtime and have deployed with the DataSpaces staging service on leadership class computing machines and present an experimental evaluation in the article. Here, the experiments demonstrate that CoREC can tolerate in-memory data failures while maintaining low latency and sustaining high overall storage efficiency at large scales.

97 MATHEMATICS AND COMPUTING↗

Assessing uncertainty in the timing of energy use during cost-optimal distributed energy technology selection and sizing

This paper empirically derives uncertainty ranges in cost-optimal solar PV and storage sizing by comparing results from the REopt Lite optimization platform from metered data and a set of simulated Department of Energy Commercial Reference Building (CRB) profiles at 65 sites. We find load profile shape alone does not explain a site’s optimal configurations (i.e., PV, Storage, PV and Storage, No System). Still, load profile shape does introduce uncertainty to optimal PV and storage capacities. Across all cases where PV is part of an optimal configuration, we find the average ratio of power capacities derived from metered loads to capacities derived from CRB profiles to be 0.97 (and as high as 1463), where 1 would be a perfect match in system size. For storage, the ratio is 1.6 (and as high as 42). We also assess how, in the absence of complete metered data, a CRB profile can be selected that would be expected to yield the most similar solar PV and storage capacities. From those metrics that can be available from billing data (i.e., peak demand, monthly load totals), we find that uncertainty is most reduced by selecting the CRB’s with an annual peak occurring at the most similar time, or those with the lowest average root mean square error (RMSE) among monthly peak loads. This research can help improve the implementation and interpretation of results derived from simulated load profiles and is an important next step in advancing smart grid solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Leveraging In-Network Computing and Programmable Switches for Streaming Analysis of Scientific Data

With the emergence of programmable network devices that match the performance of fixed function devices, several recent projects have explored in-network computing, where the processing that is traditionally done outside the network is offloaded to the network devices. In-network computing has typically been applied to network functions (e.g., load balancing, NAT, and DNS), caching, data reduction/aggregation, and coordination/consensus functions. In some cases it has been used to accelerate stream-processing tasks that involve small payloads and simple operations. In this work we focus on leveraging in-network computing for stream processing of scientific datasets with large payloads that require complex operations such as floating-point computations and logarithmic functions. We demonstrate in-network computing for a real-world scientific application performing streaming normalization of a 2-D image from a light source experiment. We discuss the challenges we encountered and potential approaches to address them.

Sankaran, Ganesh↗

Virtual sensing of wind turbine hub loads and drivetrain fatigue damage, Virtuelle Sensoren für die Messung von Hauptwellenlasten und Ermüdungsschäden im Antriebstrang von Windenergieanlagen

Abstract: This paper presents a Digital Twin for virtual sensing of wind turbine aerodynamic hub loads, as well as monitoring the accumulated fatigue damage and remaining useful life in drivetrain bearings based on measurements of the Supervisory Control and Data Acquisition (SCADA) and the drivetrain condition monitoring system (CMS). The aerodynamic load estimation is realized with data-driven regression models, while the estimation of local bearing loads and damage is conducted with physics-based, analytical models. Field measurements of the DOE 1.5 research turbine are used for model training and validation. The results show low errors of 6.4% and 1.1% in the predicted damage at the main and the generator side high-speed bearing respectively. Zusammenfassung: In diesem Aufsatz wird ein digitaler Zwilling für Windenergieanlagen vorgestellt, welcher die virtuelle Erfassung der Hauptwellenlasten und die Zustandsüberwachung von Ermüdungschäden und der verbleibende Nutzungsdauer der Antriebsstranglager ermöglicht. Der digital Zwilling nutzt Messdaten des Supervisory Control and Data Acquisition (SCADA) Systems und des Zustandsüberwachungssystems des Antriebsstranges (CMS). Die Berechnung der Hauptwellenlasten ist mit datenbasierten Regressionsmodellen umgesetzt, während die Berechnung der Lagerkräfte und der Ermüdungsschaden mit physikbasierten Modelle durchgeführt wird. Für die Modellentwicklung und -validierung werden Feldmessdaten der DOE 1.5MW Turbine eingesetzt. Die Abweichungen in den Ermüdungsschäden am Hauptwellenlager und am Generatorwellenlager betragen lediglich 6,4% beziehungsweise 1,1%.

17 WIND ENERGY↗

Concurrent Relaxation through Accelerated Deep Learning

CRADL captures performance metrics of machine learning algorithms operating on mesh data from multiphysics codes This proxy application is a tool to explore scalability of inference on HPC platforms, and also gather performance metrics for inference on new machine learning specific hardware. CRADL is designed to give users as fine a control as possible over an inference simulation. Users may select the number of cycles, amount of data, and batch size to pass to the accelerator of choice. Additionally the user may select a number of performance optimization libraries and flags. CRADL comes packaged with a repository of anonymized multi-physics simulation data, as well as a pretrained model for inference. The code allows a user to load their own pre-trained model and data if they wish. The code can operate in multiple parallelization schemes, with performance enhancing options such as half-precision libraries, PyTorch benchmarking, and pinned memory with non-blocking data transfers.

Zieb, KristoferJ.↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

Verification Problems for Smooth Step Amplitude Load Curves in DYNA3D/Paradyn

This report documents the addition of three new verification tests in the LOADCURVE directory of the DYNA3D/Paradyn Software Quality Assurance test suite. Each test consists of a single element, where the velocities of each node are specified by either the newly added smooth step tabular load curve or another load curve option. The first test assesses the initialization and interpolation of the newly inputted load curve option through tabulated abscissa-ordinate pairs of data. The second test uses the same set of abscissa-ordinate data points and applies offset and scaling parameters available within the load curve definition. The third test defines the smooth step load curve in an original input deck, and assesses its correct redefinition using a restart file. The simulation velocities are compared to their true values at discrete points in time, and each test is verified up to numerical precision. These results confirm that the smooth step load curve option is functioning correctly and as intended.

97 MATHEMATICS AND COMPUTING↗