Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final report: Insights from ARM observations into aerosol processing and transport by extratropical cyclones and aerosol effects on cyclone clouds

This project advanced understanding of aerosol–cloud interactions in extratropical cyclones using observations from the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) observatory and ACE-ENA field campaigns, along with satellite datasets and numerical modeling. We have quantified the susceptibility of frontal clouds to aerosols, showing that this susceptibility is similar to that in non-frontal clouds despite substantial (factor 2) differences in droplet concentrations between these cloud types, and also significant differences in cloud albedo. A key finding was that Aitken-mode (here, 60-100nm diameter) aerosols play a disproportionately important role in droplet activation in frontal clouds, and concentrations of these particles are frequently strongly biased in climate models. Activation of aerosols depends strongly on updraft speeds, and via collaboration with Argonne National Laboratory we contributed to quantifying these better with the ARM radar wind profiler at the ENA site. Our studies in the North Atlantic have analogs in the Southern Ocean, and to draw these out we examined data from the MARCUS and SOCRATES field campaigns. We identified new particle formation within extratropical cyclones as a potentially important source of cloud condensation nuclei in these pristine marine environments. By combining ARM observations with perturbed parameter ensemble simulations, we demonstrated that surface observations can effectively constrain aerosol–cloud adjustments and reduce uncertainty in simulated cloud liquid water path responses by approximately 15%, yielding stronger constraints on historical aerosol cooling effects. The work further established precipitation processes as a dominant control on aerosol–cloud interactions and Earth system predictability.

Gordon, Hamish [Department of Chemical Engineering↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗

Growth of Nanocrystal Superlattices from Liquid Crystals

The growth of superlattices (SLs) made from self-assembled nanocrystals (NCs) is a powerful method for creating new materials and gaining insight into fundamental molecular dynamics. Previous explorations of NCSL syntheses have mostly compared them to crystallization. However, NCSL synthesis has not broadly shown cooling crystallization from saturated solutions as a reversible crystallization–dissolution process. We demonstrate the reversible growth of NCSLs by dispersing NCs in liquid crystal (LC) “smart solvents,” and harnessing the transitions between the isotropic and nematic phases of the LCs. The growth mode and morphology can be tuned. Furthernore, this process is a model platform for studying crystallization and demonstrates great potential in manufacturing NCSLs as colloidal crystals through liquid-phase epitaxy or colloidal synthesis.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design and Analysis of the Open-Surface Slow Li Flow Divertor and Comparison to the Fast Li Flow Divertor

In the ongoing U.S. project, “Liquid Metal Plasma Facing Components,” sponsored by the U.S. Department of Energy, efforts have been taken to develop two open-surface divertor designs for the Fusion Nuclear Science Facility using liquid lithium (Li) as a heat and particle flux removal media. The main focus of this study is the design and analysis of a slow (~1 mm/s) and thin (<1 mm) open-surface Li flow divertor with a Li-cooled substrate, which is then compared with an earlier design of a fast (up to 10 m/s) and thick (~0.5 cm) Li flow divertor with the substrate cooled with helium. The slow Li flow divertor design is based on the original LiWall concept developed at the Princeton Plasma Physics Laboratory. Such a thin and slow Li layer can remove the particle flux by reducing the recycling flux, while the heat flux is removed mainly through the heat sink located beneath. In the present study, the heat sink is provided through a Li cooling flow inside the substrate of reduced activation ferritic/martensitic steel. By performing a multiphysics analysis with COMSOL that included liquid-metal magnetohydrodynamics (MHD), heat transfer, and structural mechanics, the impact of various factors on the divertor heat removal capability, such as Li flow velocity, MHD effects, and inlet velocity boundary condition, were examined. Based on comparisons of the two divertor designs, it was shown that the fast-flow divertor significantly outperformed the slow-flow design, whose heat removal capability was limited to ~1 to 2 MW/m2.

Jiang, Yuchen [ORNL] (ORCID:0000000283280284)↗

Structural changes across thermodynamic maxima in supercooled liquid tellurium: a water-like scenario

Liquid polymorphism is an intriguing phenomenon which has been found in a few single-component systems, the most famous being water. By supercooling liquid Te to more than 130 K below its melting point and performing simultaneous small-angle and wide-angle X-ray scattering measurements, we observe clear maxima in its thermodynamic response functions around 615 K, suggesting the possible existence of liquid polymorphism. A close look at the underlying structural evolution shows the development of intermediate-range order upon cooling, most strongly around the thermodynamic maxima, which we attribute to bond-orientational ordering. The striking similarities between our results and those of water, despite the lack of hydrogen-bonding and tetrahedrality in tellurium, indicate that water-like anomalies may be a general phenomenon among liquid systems with competing bond- and density-ordering.

36 MATERIALS SCIENCE↗

Porous mesh manifold for enhanced boiling performance

High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wick assisted embedded evaporative cooling of motors

A cooling system for an electric motor that includes a stator having a plurality of slot windings and a rotor, coaxial with the stator, having a plurality of magnets, includes a coolant inlet to the motor and a coolant outlet from the motor. A coolant pathway is in fluid communication with the inlet and the outlet. Heat is transferable from the slot windings to the coolant pathway. A coolant flows through the coolant pathway and is in a liquid phase as it enters the coolant inlet, changing into a gaseous phase as heat is transferred to the coolant from the slot windings. A cooling loop is in fluid communication with the coolant inlet and the coolant outlet. The cooling loop cools the coolant so that substantially all of the coolant is in the liquid phase when it enters the coolant inlet.

Joshi, Yogendra K.↗

Nuclear Safety [Vol. 33, No. 4, October-December 1992]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 499 Technical Note: Nuclear Regulatory Commission’s Examination Question Bank System, C. L Jensen and N. L. Skinner; 506 Report on the Specialists’ Meeting on Passive and Active Safety Features of Liquid-Metal Fast Breeder Reactors Organized by the International Atomic Energy Agency at Oarai Engineering Centre of Power Reactor and Nuclear Development Corporation, Japan, November 5-7,1991, S. R. Paranjpe; ACCIDENT ANALYSIS: 514 A Review of Hydrogen Production During Melt/Water Interaction in LWRs, D. F. Fletcher, B. D. Turland, and S. P. A. Lawrence; 535 A Review of the U 3 0 8 -Al Reaction as a Potential Heat Source in Research and Test Reactor Accidents, J. L. Snelgrove; CONTROL AND INSTRUMENTATION: 543 Multilevel Interfaces for Power Plant Control Rooms II: A Preliminary Design Space, K. J. Vicente; DESIGN FEATURES: 549 Twenty-Second DOE/NRC Nuclear Air Cleaning and Treatment Conference, R. R. Bellamy, D. W. Moeller, and M. W. First; 562 Book Review: Safety Assessment of Unit 5 (WWER-440/W-213) of the Greifswald Nuclear Power Station, M. H. Fontana; WASTE AND SPENT FUEL MANAGEMENT: 576 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver; OPERATING EXPERIENCES: 586 Analysis of Corrective Actions Applied to Nuclear Power Plant Operations, A. E. Cross; 593 Reactor Shutdown Experience, Compiled by J. W. Cletcher; 596 Operating U.S. Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver; 609 Non-Commercial Power Operating Experience; 614 World Nuclear Performance, Compiled by M. D. Muhlheim; RECENT DEVELOPMENTS: 623 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 635 Reports, Standards, and Safety Guides, D. S. Queener; 639 Proposed Rule Changes as of June 30, 1992; ANNOUNCEMENTS: 513 Fourth International Conference on Nuclear Fuel Reprocessing and Waste Management RECOD '94; 585 International Topical Meeting on Advanced Reactors Safety; 622 International Workshop on Implementation of ALARA at Nuclear Power Plants; 648 Short Course on Nuclear Criticality Safety; 648 8th Topical Meeting on Problems in Reactor Physics MEPhi-VOLGA-93; 643 The Authors; 646 Reviewers of Nuclear Safety, Vol. 33

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unraveling the formation mechanism of NaCoPO 4 polymorphs

Phosphate compounds are one of the attractive classes of cathodes for their potential application in rechargeable Na-ion batteries (NIBs) due to their high insertion voltages and stabilities. Unlike olivine-LiMPO 4 (M = Fe, Mn, Co, Ni) cathodes, maricite-NaMPO 4 phases are electrochemically inactive due to lack of sodium diffusion channels. Interestingly, cobalt bearing compounds exhibit rich polymorphism (α-, β-, ABW- and Red-NaCoPO 4 ). However, the preparation of NaCoPO 4 single phases is challenging due to their closer enthalpies of formation. In this study, we have attempted to understand the formation mechanism of NaCoPO 4 polymorphs during solid state reaction using two different cobalt precursors (Co(OH) 2 and CoCO 3 ). The temperature dependent in-situ powder X-ray Diffraction (PXRD) studies showed the formation of β-NaCoPO 4 at a much lower temperature compared to the one reported in the literature, whilst we have discovered a new high temperature polymorph gamma-NaCoPO 4 . The choice of precursors was also found to be important for the preparation of ABW-NaCoPO 4 , i.e., the rapid decomposition of Co(OH) 2 has resulted in its formation whilst the high stability of CoCO 3 prohibited the same. The order of the formation of the NaCoPO 4 polymorphs during heating was found to be ABW→β→α →$\gamma$. During normal cooling, gamma-NaCoPO 4 transformed primarily into alpha-polymorph whilst quenching in liquid N-2 resulted in the formation of β-NaCoPO 4 The as-synthesized beta- and ABW-NaCoPO 4 phases exhibited high sodium (de)-intercalation voltages (similar to 4.2 and 4.5 V vs. Na + /Na 0 , respectively), albeit with limited reversible capacities. This study is expected to open new avenues to harvest metastable polymorphs based on other transition metals (Fe, Mn and Ni).

25 ENERGY STORAGE↗

Numerical implementation of the MOOSE subchannel module (SCM) algorithm

The subchannel module of moose (SCM), previously referred to as Pronghorn-SC, is a subchannel code designed to resolve single-phase flow fields and calculate the relevant flow variables, in nuclear reactor fuel-pin assemblies. The assemblies it models are: water-cooled, with bare fuel-pins in a square ducted, quadrilateral lattice and liquid-metal/water-cooled, with bare/wire-wrapped fuel pins in a hexagonal ducted, triangular lattice. Previous publications have presented the development, validation and verification of SCM. This work presents an comparative overview of the different solvers implemented within SCM. This includes the solver algorithm description, and a performance comparison. The two test cases chosen to demonstrate the solver performance were taken from the PSBT enthalpy mixing benchmark and the ORNL-19 pin benchmark.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

High resolution diagnostic tools for superconducting radio frequency cavities

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 –10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two high-resolution diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system, which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. This setup has a spatial resolution of ~ 13 μm in the azimuthal direction and ~ 1 cm along the cavity contour. The second setup is a stationary, combined magnetic and temperature mapping system, which uses anisotropic magnetoresistance sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. This system has a spatial resolution of 5 mm close to the iris and 11 mm at the equator. Initial results show a non-uniform distribution of trapped flux on the cavities’ surfaces, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A scanning quantum cryogenic atom microscope at 6 K

The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) is a quantum sensor in which a quasi-1D quantum gas images electromagnetic fields emitted from a nearby sample. We report improvements to the microscope. Cryogen usage is reduced by replacing the liquid cryostat with a closed-cycle system and modified cold finger, and cryogenic cooling is enhanced by adding a radiation shield. The minimum accessible sample temperature is reduced from 35~K to 5.7~K while maintaining low sample vibrations. A new sample mount is easier to exchange, and quantum gas preparation is streamlined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Q-dependent collective relaxation dynamics of glass-forming liquid Ca0.4K0.6(NO3)1.4 investigated by wide-angle neutron spin-echo

Abstract The relaxation behavior of glass formers exhibits spatial heterogeneity and dramatically changes upon cooling towards the glass transition. However, the underlying mechanisms of the dynamics at different microscopic length scales are not fully understood. Employing the recently developed wide-angle neutron spin-echo spectroscopy technique, we measured the Q -dependent coherent intermediate scattering function of a prototypical ionic glass former Ca 0.4 K 0.6 (NO 3 ) 1.4 , in the highly viscous liquid state. In contrast to the structure modulated dynamics for Q < 2.4 Å −1 , i.e., at and below the structure factor main peak, for Q > 2.4 Å −1 , beyond the first minimum above the structure factor main peak, the stretching exponent exhibits no temperature dependence and concomitantly the relaxation time shows smaller deviations from Arrhenius behavior. This finding indicates a change in the dominant relaxation mechanisms around a characteristic length of 2π/(2.4 Å −1 ) ≈ 2.6 Å, below which the relaxation process exhibits a temperature independent distribution and more Arrhenius-like behavior.

42 ENGINEERING↗