Modeling structural damping for solids having distinct shear and dilatational loss factors
For steady state time harmonic problems (rigid format 8), the NASTRAN program as currently configured treats internal structural damping through the introduction of a single structural element damping coefficient that typically is viewed as the ratio of the complex to real modulus of elasticity. For problems dealing with two or three dimensional dynamic linear viscoelasticity (e.g. a Kelvin-Voigt viscoelastic model), the present NASTRAN capability cannot directly handle this situation wherein two independent damping coefficients are required to properly model the dissipation phenomenon. A technique is presented whereby the user can adapt the standard versions of NASTRAN (without resorting to either DMAP and/or FORTRAN coding changes) for the purpose of treating this class of problem.