Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “life testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings

A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for the four actuators on one shuttle, each with a 2-bearing shaft assembly, established a reliability level of 96.9 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.

Oswald, Fred B.↗

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

Wear Mechanisms in Electron Sources for Ion Propulsion, 1: Neutralizer Hollow Cathode

Upon the completion of two long-duration life tests of a 30-cm ion engine, the orifice channel of the neutralizer hollow cathode was eroded away to as much as twice its original diameter. Whereas the neutralizer cathode orifice opened significantly, no noticeable erosion of the discharge cathode orifice was observed. Noquantitative explanation of these erosion trends has been established since the completion of the two life tests. A two-dimensional model of the partially ionized gas inside these devices has been developed and applied to the neutralizer hollow cathode. The numerical simulations show that the main mechanism responsible for the channel erosion is sputtering by Xe+. These ions are accelerated by the sheath along the channel and bombard the surface with kinetic energy/charge of about 17 V at the beginning of cathode life. The density of the ions inside the neutralizer orifice is computed to be as high as 2.1 x 10(sup 22) m(sup -3). Because of the 3.5-times larger diameter of the discharge cathode orifice, the ion density inside the orifice is more than 40 times lower and the sheath drop 7 V lower compared with the values in the neutralizer. At these conditions, Xe+ can cause no significant sputtering of the surface.

ionized gas↗

Effect of Post-HALT Annealing on Leakage Currents in Solid Tantalum Capacitors

Degradation of leakage currents is often observed during life testing of tantalum capacitors and is sometimes attributed to the field-induced crystallization in amorphous anodic tantalum pentoxide dielectrics. However, degradation of leakage currents and the possibility of annealing of degraded capacitors have not been investigated yet. In this work the effect of annealing after highly accelerated life testing (HALT) on leakage currents in various types of solid tantalum capacitors was analyzed. Variations of leakage currents with time during annealing at temperatures from 125 oC to 180 oC, thermally stimulated depolarization (TSD) currents, and I-V characteristics were measured to understand the conduction mechanism and the reason for current degradation. Annealing resulted in a gradual decrease of leakage currents and restored their initial values. Repeat HALT after annealing resulted in reproducible degradation of leakage currents. The observed results are explained based on ionic charge instability (drift/diffusion of oxygen vacancies) in the tantalum pentoxide dielectrics using a modified Schottky conduction mechanism.

Teverovsky, Alexander↗

Stress Testing of Chip Aluminum Polymer Capacitors

Layered aluminum polymer capacitors (APC) may be viable replacements to current chip tantalum capacitors due to their lower ESR, weight, and smaller size. So far, there is a lack of information regarding the reliability of these parts. Available technical literature is mostly related to the effect on humidity. Although APCs have a limited moisture resistance, it may be contained to the level sufficient for space applications. In this work, seven types of commercial APCs manufactured by four vendors and rated to voltages from 6.3 to 35 V were used to evaluate reliability of the parts under environmental stresses and highly accelerated life tests. Characteristics of the parts, including breakdown voltages, the level of anomalous charging currents (ACC), capacitance, DF, ESR and leakage currents were measured in the process of storage at high-temperatures (from 100 to 150 °C) and high humidity at 85 °C. Monitored highly accelerated life tests have been carried out at temperatures of 85 °C and 125 °C and voltages varying from 1.2 to 1.9 times the rated voltage. Degradation processes and reliability of APCs have been analyzed and compared to polymer tantalum capacitors.

Alexander Teverovsky↗

Testing and Life Prediction for Composite Rotor Hub Flexbeams

A summary of several studies of delamination in tapered composite laminates with internal ply-drops is presented. Initial studies used 2D FE models to calculate interlaminar stresses at the ply-ending locations in linear tapered laminates under tension loading. Strain energy release rates for delamination in these laminates indicated that delamination would likely start at the juncture of the tapered and thin regions and grow unstably in both directions. Tests of glass/epoxy and graphite/epoxy linear tapered laminates under axial tension delaminated as predicted. Nonlinear tapered specimens were cut from a full-size helicopter rotor hub and were tested under combined constant axial tension and cyclic transverse bending loading to simulate the loading experienced by a rotorhub flexbeam in flight. For all the tested specimens, delamination began at the tip of the outermost dropped ply group and grew first toward the tapered region. A 2D FE model was created that duplicated the test flexbeam layup, geometry, and loading. Surface strains calculated by the model agreed very closely with the measured surface strains in the specimens. The delamination patterns observed in the tests were simulated in the model by releasing pairs of MPCs along those interfaces. Strain energy release rates associated with the delamination growth were calculated for several configurations and using two different FE analysis codes. Calculations from the codes agreed very closely. The strain energy release rate results were used with material characterization data to predict fatigue delamination onset lives for nonlinear tapered flexbeams with two different ply-dropping schemes. The predicted curves agreed well with the test data for each case studied.

Murri, Gretchen B.↗

Degradation of Leakage Currents and Reliability Prediction for Tantalum Capacitors

Two types of failures in solid tantalum capacitors, catastrophic and parametric, and their mechanisms are described. Analysis of voltage and temperature reliability acceleration factors reported in literature shows a wide spread of results and requires more investigation. In this work, leakage currents in two types of chip tantalum capacitors were monitored during highly accelerated life testing (HALT) at different temperatures and voltages. Distributions of degradation rates were approximated using a general log-linear Weibull model and yielded voltage acceleration constants B = 9.8 +/- 0.5 and 5.5. The activation energies were Ea = 1.65 eV and 1.42 eV. The model allows for conservative estimations of times to failure and was validated by long-term life test data. Parametric degradation and failures are reversible and can be annealed at high temperatures. The process is attributed to migration of charged oxygen vacancies that reduce the barrier height at the MnO2/Ta2O5 interface and increase injection of electrons from the MnO2 cathode. Analysis showed that the activation energy of the vacancies' migration is ~ 1.1 eV.

acceleration factors↗

Qualification of the Flight Heaters for the NEXT-C Hollow Cathodes

After successful validation of the design, swaged cathode heaters have been delivered by the NASA Glenn Research Center to Aerojet Rocketdyne for the fabrication of the NEXT-C ion thruster. NASA Glenn Research Center re-established and validated process controls as well as completed cyclic life testing of development heaters. Following an extensive requalification program, fabrication of a flight batch of heaters was executed using the qualified process controls. Of the 28 heaters fabricated in this flight batch, a set of six heaters were acceptance and cyclic tested to verify conformance with operational requirements. Upon completion of 200 percent of the NEXT-C cyclic requirement, the heater batch was certified by NASA for use in the flight hollow cathodes. Nine heaters from the batch of 28 were provided to Aerojet Rocketdyne in early 2018 for cathode fabrication. This paper summarizes the acceptance and cyclic life testing of the flight heaters and preliminary findings of post-test analyses.

Arthur, Neil↗

Qualification of the Flight Heaters for the NEXT-C Hollow Cathodes

After successful validation of the design, swaged cathode heaters have been delivered by the NASA Glenn Research Center to Aerojet Rocketdyne for the fabrication of the NEXT-C ion thruster . NASA Glenn Research Center re-established and validated process controls as well as completed cyclic life testing of development heaters. Following an extensive requalification program, fabrication of a flight batch of heaters was executed using the qualified process controls. Of the 28 heaters fabricated in this flight batch, a set of six heaters were acceptance and cyclic tested to verify conformance with operational requirements. Upon completion of 200 percent of the NEXT-C cyclic requirement, the heater batch was certified by NASA for use in the flight hollow cathodes. Nine heaters from the batch of 28 were provided to Aerojet Rocketdyne in early 2018 for cathode fabrication. This paper summarizes the acceptance and cyclic life testing of the flight heaters and preliminary findings of post-test analyses.

Arthur, Neil↗

QualifiCation of the Flight Heaters for the NEXT-C Hollow Cathodes

After successful validation of the design, swaged cathode heaters have been delivered by the NASA Glenn Research Center to Aerojet Rocketdyne for the fabrication of the NEXT-C ion thruster . NASA Glenn Research Center re-established and validated process controls as well as completed cyclic life testing of development heaters. Following an extensive requalification program, fabrication of a flight batch of heaters was executed using the qualified process controls. Of the 28 heaters fabricated in this flight batch, a set of six heaters were acceptance and cyclic tested to verify conformance with operational requirements. Upon completion of 200 percent of the NEXT-C cyclic requirement, the heater batch was certified by NASA for use in the flight hollow cathodes. Nine heaters from the batch of 28 were provided to Aerojet Rocketdyne in early 2018 for cathode fabrication. This paper summarizes the acceptance and cyclic life testing of the flight heaters and preliminary findings of post-test analyses.

Arthur, Neil↗

Storage Stability and Improvement of Intermediate Moisture Foods

Shelf life tests are used to estimate the rate of nonenzymatic browning; however, controlling the reducing sugar levels below 23:1 molar ratio to amines, slows the rate. In addition, liquid glycols surpress browning. The protozoan Tetrahymena pyriformis W can be used to estimate nutrition losses during browning. At high temperatures (80 to 120 C) used in processing intermediate moisture foods (IMF), vitamin C destruction shifts to a zero order mechanism. BHA and BHT are the most effective antioxidants against rancidity. In shelf life testing however, 45 C should be the maximum temperature used. Water binding agents are studied. The five isotherms of thirteen humectants were determined. The results show that neither the method of addition nor sequence of addition affects the a sub u lowering ability of these humectants. Results were used to formulate shelf stable IMF processed cheese foods with at least four months shelf life.

Labuza, T. P.↗

Extended Performance 8-cm Mercury Ion Thruster

A slightly modified 8-cm Hg ion thruster demonstrated significant increase in performance. Thrust was increased by almost a factor of five over that of the baseline thruster. Thruster operation with various three grid ion optics configurations; thruster performance as a function of accelerator grid open area, cathode baffle, and cathode orifice size; and a life test of 614 hours at a beam current of 250 mA (17.5 mN thrust) are discussed. Highest thruster efficiency was obtained with the smallest open area accelerator grid. The benefits in efficiency from the low neutral loss grids were mitigated, however, by the limitation such grids place on attainable ion beam current densities. The thruster components suffered negligible weight losses during a life test, which indicated that operation of the 8-cm thruster at extended levels of thrust and power is possible with no significant loss of lifetime.

Mantenieks, M. A.↗

Benchmark notch test for life prediction

Aircraft gas turbine engine components are subjected to severe stress, temperature, and environmental conditions. Economic and reliabilty demands have prompted inordinate effort in development of analytic methods to predict stresses and strains in aircraft engines. There remains, however, the need to check or verify these analytical methodologies against actual experimental data measurements. The laser interferometric strain displacement gage was recognized as having the potential to accomplish this task and was employed in this program. The actual strains incurred at the root of a discontinuity in cyclically loaded test samples subjected to inelastic deformation at high temperature where creep deformation readily occur were measured. The steady-state, cyclic stress-strain response at the root of the discontinuity in the tested samples was analyzed for comparison with the measured results. A comprehensive set of local notch root strain measurements for a variety of load patterns in an Inconel 718 notch specimen at 649 C (1200 F) was obtained and documented using the laser interferometric strain displacement gage.

Domas, P. A.↗

Evaluation of Aluminum Polymer Capacitors for Space Applications

Layered aluminum polymer capacitors (APC) may be viable replacements to currently used chip tantalum capacitors due to their lower ESR, weight, and smaller size. So far, there is a lack of information regarding the reliability of these parts. Available technical literature is mostly related to the effect of humidity. Although APCs have a limited moisture resistance, it may be contained to the level sufficient for space applications. This work analyzes construction and characteristics of seven types of commercial APCs manufactured by four vendors and rated to voltages from 6.3 to 35 V were analyzed. Their reliability under environmental stresses and highly accelerated life tests was assessed in the range of temperatures and voltages to determine reliability acceleration factors. For this purpose, characteristics of the parts, including breakdown voltages, the level of anomalous charging currents (ACC), capacitance, DF, ESR and leakage currents were measured in the process of storage at high-temperatures (from 100 to 150 °C) and high humidity at 85 °C. Monitored highly accelerated life tests have been carried out at temperatures of 85 °C and 125 °C and voltages varying from 1.2 to 1.9 times the rated voltage. Degradation processes and reliability of APCs have been compared to polymer tantalum capacitors.

Alexander A Teverovsky↗

Johnson Space Center's regenerative life support systems test bed

The Regenerative Life Support System (RLSS) Test Bed at NASA's Johnson Space Center is an atmospherically closed, controlled environment facility for the evaluation of regenerative life support systems using higher plants in conjunction with physicochemical life support systems. When completed, the facility will be comprised of two large scale plant growth chambers, each with approximately 10 m(exp 2) growing area. One of the two chambers, the Variable Pressure Growth Chamber (VPGC), will be capable of operating at lower atmospheric pressures to evaluate a range of environments that may be used in Lunar or Martian habitats; the other chamber, the Ambient Pressure Growth Chamber (APGC) will operate at ambient atmospheric pressure. The root zone in each chamber will be configurable for hydroponic or solid state media systems. Research will focus on: (1) in situ resource utilization for CELSS systems, in which simulated lunar soils will be used in selected crop growth studies; (2) integration of biological and physicochemical air and water revitalization systems; (3) effect of atmospheric pressure on system performance; and (4) monitoring and control strategies.

Henninger, Donald L.↗

Solutions for discharge chamber sputtering and anode deposit spalling in small mercury ion thrusters

Proposed solutions to the problems of sputter erosion and sputtered material spalling in the discharge chamber of small mercury ion thrusters are presented. The accelerated life test evaluated three such proposed solutions: (1) the use of tantalum as a single low sputter yield material for the exposed surfaces of the discharge chamber components subject to sputtering, (2) the use of a severely roughened anode surface to improve the adhesion of the sputter-deposited coating, and (3) the use of a wire cloth anode surface in order to limit the size of any coating flakes which might spall from it. Because of the promising results obtained in the accelerated life test with anode surfaces roughened by grit-blasting, experiments were carried out to optimize the grit-blasting procedure. The experimental results and an optimal grit-blasting procedure are presented.

Power, J. L.↗

Development of a short pulsed solid propellant plasma thruster

The experimental results are summarized that were obtained in the development of a Teflon solid propellant pulsed plasma thruster. The feasibility was established of storing and feeding solid propellant in the form of an open circular loop into an operational thruster. This technique was verified to be practical by feeding over 20 inches of Teflon into a micro-thruster over an accumulated life test of 1858 hours. High energy density capacitors were evaluated under vacuum conditions when the capacitor is coupled directly to a plasma thruster. Numerous early capacitor failures were encountered. It was concluded that essentially all of the failures encountered in a vacuum environment are due to an internal electrical breakdown that will occur inside a capacitor that is not truly hermetically sealed. A steady input power significantly in excess of 130 watts can safely be tolerated if heat conduction can be provided to a sink whose temperature is about 16 C. A vacuum life test of the capacitor bank was carried out while discharging into a milli-lb. (milli-Newton) type pulsed plasma thruster. More than 1500 hours of vacuum testing of this milli-Newton type system has been accumulated without any capacitor problems. Recommendations are made for future capacitor designs.

Guman, W. J.↗