Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “issues management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Optimizing Information Automation Using a New Method Based on System-Theoretic Process Analysis: Tool Development and Method Evaluation

This report is an update to a prior report that describes progress and findings for a program of research supporting the design and optimization of information automation systems for nuclear power plants. Much of the domestic nuclear fleet is currently focused on modernizing technologies and processes, including transitioning toward digitalization in the control room and throughout the plant, along with a greater interest in the use of automation, artificial intelligence, robotics, and other emerging technologies. While there are significant opportunities to apply these technologies toward greater plant safety, efficiency, and overall cost-effectiveness, optimizing their design and avoiding potential safety and performance risks depends on ensuring that human performance-related organizational and technical design issues are identified and addressed early in the design process. This report describes modeling tools and techniques, based on sociotechnical systems theory, to support these design goals and their application in the current research effort. The report is primarily intended for senior nuclear energy stakeholders, including regulators, corporate management, and senior plant management. We have developed and employed a method to design an optimized information automation ecosystem (IAE) based on the systems-theoretic constructs underlying sociotechnical systems theory in general and the Systems-Theoretic Accident Modeling and Processes (STAMP) approach in particular. We argue that an IAE can be modeled as an interactive information control system whose behavior can be understood in terms of dynamic control, feedback, and communication relationships amongst the system’s technical and organizational components. We have employed two STAMP-based tools in this effort. The first is Causal Analysis based on STAMP (CAST), an accident and incident analysis technique that was used to examine a performance- and safety-related incident at an industry partner’s plant involving the unintentional activation of an emergency diesel generator. This analysis provided insight into the behavior of the plant’s current information control structure within the context of a specific, significant event. The second tool is Systems Theoretic Process Analysis (STPA) which is a proactive risk analysis tool used to examine existing and potential, planned sociotechnical systems. STPA was used to identify risk factors in the current design of a generic nuclear power plant (NPP) preventive maintenance system. Our analyses focused on identifying near-term system improvements and longer-term design requirements for an optimized IAE system. CAST analysis findings indicate an important underlying contributor to the incident under investigation, and a significant risk to information automation system performance, was perceived time and schedule pressure, which exposed weaknesses in interdepartmental coordination between and within responsible plant organizations and challenged the resilience of established plant processes, until a human caused the eventual event. These findings are discussed in terms of their risk to overall system performance and their implications for information automation system resilience and brittleness. STPA findings exposed several areas of concern in the design of current preventive maintenance systems. We also present two preliminary information automation models. The proactive issue resolution (PIR) model is a test case of an information automation concept with significant near-term potential for application and subsequent reduction in significant plant events. The IAE model is a more general representation of a broader, plantwide information automation system and represents an end-state vision for our work. From our results, we have generated an initial set of preliminary system-level requirements and safety constraints for these models. We have also focused on early development of easy to learn, easy to use “transportable” tools for sociotechnical systems analysis. We intend these to be used by NPP personnel as a means of gaining reliable and relatively quick insight into (1) sociotechnical systems factors impacting incidents and accidents, (2) potential sociotechnical risk factors in existing or planned system designs, and (3) potential weaknesses in a system’s safety and/or information control structure. We conclude the report with a set of summary recommendations, a discussion of planned and potential follow-on research and development, and a draft list of system-level requirements and safety constraints for optimized information automation systems.

99 GENERAL AND MISCELLANEOUS↗

EVs-at-RISC: A Secure and Resilient Interoperable SCM Control System Architecture for Electric Vehicle’s-at-Scale (Final Technical Report)

The EVs-at-RISC project was a five-year research, development, and demonstration initiative to create foundational tools for utility-scale fleet aggregation and Smart Charge Management (SCM) of Electric Vehicles (EV), Electric Vehicle Charging Infrastructure (EVCI), and related Distributed Energy Resources (DER). Rather than seeking to develop and demonstrate highly perfected SCM algorithms and control strategies, this project instead focused on creating foundational software solutions that enable unprecedented digital interoperability across the communications technologies and vendor platforms used to manage EV , EVCI, and DER, as well as existing energy management infrastructure operated by utilities, grid operators, and aggregators. This project then extends these novel interoperability capabilities to develop and deploy powerful middleware abstractions across grid edge networks and EVCI/DER fleet aggregations incorporating modern software tools and best practices, such as CI/CD, to bring the immense capabilities of infrastructure-as-code and policy-as-code to modern grid edge network environments. This addresses the foremost systemic issues preventing realization of any net operational benefits from scaled deployment of behind-the-meter EV, EVCI, and DER assets in electric power grids and markets today. The results of this approach and project unlock massive potential for new SCM capabilities to be easily prototyped, evaluated, and deployed at-scale within the existing grid edge network infrastructure and EVCI/DER technology ecosystem. The EVs-at-RISC project achieves this by extending Open Field Message Bus (OpenFMB), a conceptual model for digital interoperability and distributed intelligence in traditional front-of-meter utility SCADA networks, validating our hypothesis that OpenFMB could be similarly used to solve systemic digital interoperability issues in behind-the-meter environments and unlock real-world utility-scale SCM capabilities without requiring any new proprietary vendor solutions or significant infrastructure reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Energy Research Institute for India and the United States (SERIIUS): Lessons and Results from a Binational Consortium

This book describes the development, functioning, and results of a successful binational program to promote significant scientific advances in Earth-abundant photovoltaics (PV) and concentrated solar power (CSP), advanced process/manufacturing technologies, multiscale modeling and reliability testing, and analysis of integrated solar energy systems. SERIIUS is a consortium between India and the United States dedicated to developing new solar technologies and assessing their potential impact in the two countries. The consortium consists of nearly 50 institutions including academia, national laboratories, and industry, with the goal of developing significant new technologies in all areas of solar deployment. In addition, the program focused on workforce development through graduate students, post-doctoral students, and an international exchange program. Particular emphasis was placed on the following efforts: creating disruptive technologies in PV and CSP through high-impact fundamental and applied research and development (R&D); identifying and quantifying the critical technical, economic, and policy issues for solar energy development and deployment in India; overcoming barriers to technology transfer by teaming research institutions and industry in an effective project structure; building a new platform for binational collaboration using a formalized R&D project structure, along with effective management, coordination, and decision processes; creating a sustainable network and workforce development program from which to build large collaborations and fostering a collaborative culture and outreach programs. This includes using existing and new methodologies for collaboration based on advanced electronic and web-based communication to facilitate functional international teams. The book summarizes the general lessons learned from these experiences.

14 SOLAR ENERGY↗

Field Demonstration of Residential DER Service-Oriented Load Participation

Amidst a concerning surge in power consumption during peak hours, coupled with heightened power grid instability, and driven by a growing demand for electricity, aggregations of Distributed Energy Resource are becoming a viable means for providing essential reliability services.Electric utility companies have proactively implemented Demand Response programs for decades. These programs employ Direct Load Control methods to enhance power grid stability, achieved by controlling customers’ Distributed Energy Resource during peak hours to reduce power consumption. However, a notable drawback of Direct Load Control has been high unenrollment rates of DR program participants due to customer discomfort.Therefore, the underlying issue of over-consumption persists. To address these concerns, this paper introduces a Service-Oriented Load Participation approach to providing grid services such as Demand Response. Leveraging a Service-Oriented Architecture, this method offers the advantage of efficient service management and provisioning within the system. The SOLP approach not only aims to reduce power consumption but also to maintain customer satisfaction by ensuring a comfortable grid service experience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Timeouts Best Practices

This study investigates common timeouts encountered in the electric vehicle (EV) charging communications process. Many different timeouts are defined within the EV charging communications protocols. These timeouts can either be a fixed value or a defined range of values. In both cases, the timeout defines the duration of time for which one or both parties in the communications session are expected to wait for some action or process to complete before terminating the charge attempt. These timeout-based terminations are intended to prevent the charging process from becoming stuck indefinitely in any particular step. These terminations also enable a retry of the terminated charging session to begin. However, misaligned timeout values can have a significant negative impact on the user experience. Premature termination of charging sessions due to inappropriate timeout settings can lead to charging failures, causing inconvenience, wasted time, and frustration for users. These disruptions can degrade the overall user experience, making it essential to carefully manage and align timeout values with the relevant actions and processes to ensure reliable and satisfactory EV charging sessions. The core objective of this study is to boost reliability and enhance user experience by conducting a thorough review of timeout-based issues in EV charging and delivering a set of recommendations to modify these existing timeouts. These recommendations are informed by feedback gathered from multiple EV charging partners. This document is intended to inform electric vehicle supply equipment (EVSE) and EV manufacturers, EV charging infrastructure developers, and policymakers responsible for designing and implementing EV charging protocols and systems.

33 ADVANCED PROPULSION SYSTEMS↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lessons Learned for Responsible Use of Cloud in the Cirrus Project, Following the CrowdStrike Outage Event

A disruption in CrowdStrike’s Falcon cybersecurity platform on July 19th, 2024, caused worldwide chaos. This event highlights the imperative need for cloud security measures for networks that are critically reliant on cloud technology. This incident negatively impacted air travel, government networks, and critical infrastructure sectors such as hospitals and financial institutions. While no electric utilities had a physical impact, and few had an IT impact, there were issues created by loss of cloud services, and other interrelated industries. For utilities and energy distribution organizations, understanding and mitigating these risks is essential. The Cirrus tool offers a strategic solution engineered to weave cloud integration seamlessly into the fabric of operational management, thereby enhancing resilience and streamlining efficiency in the face of digital challenges.

25 ENERGY STORAGE↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Effects of canopy midstory management and fuel moisture on wildfire behavior

Abstract Increasing trends in wildfire severity can partly be attributed to fire exclusion in the past century which led to higher fuel accumulation. Mechanical thinning and prescribed burns are effective techniques to manage fuel loads and to establish a higher degree of control over future fire risk, while restoring fire prone landscapes to their natural states of succession. However, given the complexity of interactions between fine scale fuel heterogeneity and wind, it is difficult to assess the success of thinning operations and prescribed burns. The present work addresses this issue systematically by simulating a simple fire line and propagating through a vegetative environment where the midstory has been cleared in different degrees, leading to a canopy with almost no midstory, another with a sparse midstory and another with a dense midstory. The simulations are conducted for these three canopies under two different conditions, where the fuel moisture is high and where it is low. These six sets of simulations show widely different fire behavior, in terms of fire intensity, spread rate and consumption. To understand the physical mechanisms that lead to these differences, detailed analyses are conducted to look at wind patterns, mean flow and turbulent fluxes of momentum and energy. The analyses also lead to improved understanding of processes leading to high intensity crowning behavior in presence of a dense midstory. Moreover, this work highlights the importance of considering fine scale fuel heterogeneity, seasonality, wind effects and the associated fire-canopy-atmosphere interactions while considering prescribed burns and forest management operations.

54 ENVIRONMENTAL SCIENCES↗

Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds (Annual Status Report FY 2022)

This annual review provides the projected dose estimates of radionuclide inventories disposed in the active 200 West Area Low-Level Waste Burial Grounds (LLBGs) since September 26, 1988. These estimates are calculated using the original dose methodology developed in the performance assessment (PA) analysis (WHC-EP-0645). The estimates are compared with the performance objectives defined in U.S. Department of Energy requirements (DOE O 435.1 and its companion documents DOE M 435.1-1 and DOE-STD-5002-2017). All performance objectives are currently satisfied, and operational waste acceptance criteria (HNF-EP-0063) and waste acceptance practices continue to be sufficient to maintain compliance with performance objectives. Inventory estimates and associated dose estimates from future waste disposal actions are unchanged from previous years’ evaluations that indicate potential impacts well below performance objectives; therefore, future compliance with DOE O 435.1 is expected. Within the active burial grounds, low-level and mixed low-level waste currently may be disposed only in two lined trenches in the 218-W-5 Burial Ground (Trenches 31 and 34) until they are either filled or a decision is made to close these trenches. Some mixed low-level waste is also disposed at the Environmental Restoration Disposal Facility in the 200 West Area (which is covered under a separate PA). During this (fiscal year 2022) reporting period (October 1, 2021, through September 30, 2022), waste was disposed to the 200 West Area LLBGs. Continued groundwater monitoring of the 200 West Area LLBGs indicates no groundwater contamination due to LLBG waste. Current assumptions about future land use at the Hanford Site are consistent with PA analysis assumptions of a postclosure facility that will not be degraded by human activity. The LLBGs are in an area identified for waste management and containment of residual contamination (DOE/EIS-0391). The current closure plan for the LLBGs (DOE/RL-2000-70) estimates that the 200 West LLBGs will be closed in the 2050 timeframe. The Disposal Authorization Statement, other technical basis documents, and the radioactive waste management basis are of continued adequacy to meet the performance objectives of DOE O 435.1. Overall, there are no substantive changes to primary PA assumptions and no changes to the PA analysis conclusion; therefore, compliance with DOE O 435.1 and the Disposal Authorization Statement is maintained. A new PA to evaluate the long-term impacts of three disposal trenches that are currently active within the 200 East and 200 West Areas (Trench 94 in the 200 East Area and Trenches 31 and 34 in the 200 West Area) was initiated in fiscal year 2019 and completed in fiscal year 2022. Corrective actions addressing 3 key issues and 31 secondary issues identified during the review process were developed and submitted to the Low-Level Waste Disposal Facility Federal Review Group Co-Chairs for review and approval. This PA provides additional technical basis for the continued adequacy of the existing Operating Disposal Authorization Statement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid Power Purchase Agreements for Flexible 24/7 Energy Delivery – A Comprehensive Review of Current Practices and Research Pathways

Power Purchase Agreements (PPAs) are becoming increasingly preferred among large energy consumers, such as data centers, to secure cost-effective energy and meet accelerating demand growth. Traditionally, variable renewable energy (VRE)-based PPAs operate on a pay-as-produced basis, balancing supply and demand for a relatively longer duration (e.g., annually). However, the focus is shifting toward matching supply and demand on an hourly basis to fully meet energy needs. This shift requires the integration of flexible energy resources, such as hydropower, thermal generation, and energy storage, to complement VRE sources like wind and solar, forming the foundation for 24/7 PPA. This work contributes by: (i) reviewing emerging market trends and current practices in PPA procurement, supported by data on PPA prices and technology portfolios; (ii) synthesizing the existing literature on modeling approaches for contract pricing, quantities, hybrid resource procurement, and risk management in 24/7 PPA design, while identifying key research gaps; and (iii) proposing an integrated 24/7 PPA design framework along with two contracting mechanisms from the perspectives of both PPA providers and consumers. The proposed framework highlights critical modeling challenges, risk-allocation issues, and future research opportunities for 24/7 PPA design.

24/7↗

Data-Driven Modeling of a High Capacity Cryogenic System for Control Optimization

The Cryogenic Moderator System (CMS) is responsible for maintaining a steady flow of cold neutrons for numerous physics experiments at the Spallation Neutron Source (SNS) in Oak Ridge National Laboratory (ORNL). Sudden losses in beam power, known as beam trips, cause a major disturbance to the CMS due to large step changes in cooling demands. Ongoing efforts on upgrading the neutron beam power from 1.4 to 2.0MW are expected to generate larger transients that can further strain the CMS subsystems if they are not properly controlled. To manage such disturbances, four flow valves and one electric heater are adjusted by five decentralized proportional-integral-derivative (PID) controllers. However, the original PID gains were calibrated empirically based only on tracking performance and not based on disturbance rejection. To address this issue without compromising current CMS operations, a control-oriented model was developed to recalibrate the PID controllers offline. The zero-dimensional (0-D) model was based on simple physics-based principles and data-driven system identification techniques. The CMS was broken into several subsystems for analysis, each of which corresponds to a parametric model tied to the thermodynamic states of the working fluid. The model parameters were identified using the nonlinear least squares method where the residuals were calculated from available sensor data. Simulation results show that the proposed model can capture the dynamics of the CMS at steady state and during beam trips.

Maldonado Puente, Bryan↗

Enabling Sustainable Lithium-Ion Battery Manufacturing via Recycling

With millions of electric vehicles set to hit the road, challenges arise with both the access to a reliable supply of critical raw materials and management of spent Li-ion batteries that once powered those vehicles. From a circular economy perspective, it is critical to develop cost-effective and environmentally sustainable recycling technologies to manage end-of-life batteries and reintroduce the recovered materials into the supply chain to maintain a secure and healthy battery ecosystem. In this chapter, an overview of the current state of battery recycling is discussed by analyzing recycling’s benefits, key issues, and recycling strategies including pyrometallurgy, hydrometallurgy, and direct recycling. We also compare those recycling processes and highlight the direct recycling strategy by analyzing its benefits, working principles, and challenges. Direct recycling is still in the development stage and some recent advancements are discussed.

Bai, Yaocai↗

Analyzing School Bus Electrification in Richmond, Virginia

School buses are an essential component of the transportation infrastructure, serving as a lifeline for students across the globe. However, the widespread use of diesel school buses has raised concerns about the health impact on millions of students exposed to harmful emissions daily. Recognizing this issue, school districts worldwide are urgently seeking cleaner energy alternatives. Electric school buses emerge as an environmentally friendly and sustainable option, fostering a healthier environment for both students and communities. However, school bus electrification faces the challenges of high upfront cost, cumbersome charging management, and constraints from power grids. To help school bus operators address those challenges, this study presents a data-driven analysis for school bus electrification. This study considered a real-world school bus system in Richmond, VA, and developed a mathematical programming model to analyze the system design, charging strategies, and charging load profiles for the electrification scenario. The study evaluated different charging strategies based on model outcomes, aiming to optimize efficiency and effectiveness. Ultimately, this research generated electric school bus charging demand profiles under various scenarios, shedding light on the feasibility and implications of transitioning to electric-powered school buses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Post-Closure Inspection and Monitoring Report for Surface Corrective Action Unit 417 at the Central Nevada Test Area, Nevada, Site

This report documents the biennial postclosure site inspections conducted in June 2018 at the surface Corrective Action Unit (CA U) 417 at the Central Nevada Test Area, Nevada, Site. The UC-I, UC-3, and UC-4 sites are inspected every 2 years, in accordance with the Post-Closure Monitoring Plan provided in the CAU 417 Closure Report published in 2001. The requirements for postclosure monitoring have been modified over the years through negotiations with the Nevada Division of Environmental Protection (NDEP). Modifications were documented through three separate Records of Technical Change to the Closure Report, which were approved by NDEP in 2003, 2011, and 2015. The UC-1, UC-3, and UC-4 sites were all observed as being in good condition during the 2018 inspections. A few minor cracks on the UC-1 Central Mud Pit cover were repaired during the UC- I inspection. A concrete monument at the northeast corner of Mud Pit U3E at the UC-3 site had some damage near the top of the monument, but the damage has not impacted the functionality of the monument or survey pin on top of the monument. No issues were identified at the UC-4 site. No maintenance or additional repair activities are recommended at the UC-1, UC-3, and UC-4 sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Problems of Nuclear Technology and Radiation Safety

This work discusses ethical issues arising in the course of the development of nuclear technologies and related issues of radiation safety. Attention is paid to ethical dilemmas and proposed solutions. The author suggests a critical analysis of the relevant discussions, conducted, first of all, in the English-language literature, and muses on the specifics associated with their transfer to the Russian context. This study considers ethical problems arising in context of the depletion of uranium resources and nuclear waste management and including the inevitable risks for the present and future generations, such as inter- and intragenerational justice (Gardiner's problem) and the problem of the identity of future generations (Parfit’s problem); problems of collectivity and individuality in the assessment of permissible radiation doses for workers at nuclear enterprises and the population associated with the need to combine deontological and utilitarian approaches in the practice of radiation protection. The author demonstrates cultural differences in attitudes towards the safety of the current and future generations of the population of countries and regions and the associated ambiguities in the choice of technology for nuclear reactors, long-term disposal or processing of nuclear waste; double standards in ensuring the radiation safety of personnel of nuclear facilities and the population; ethical problems of risk compensation to workers of radiation-hazardous production facilities; issues of gender differences in sensitivity to radiation exposure, gender equality and discrimination in relation to access to the labor market in the nuclear industry. The article elucidates the importance of socio-humanitarian discussion of the ethical problems of nuclear technologies and radiation safety Such debates currently are almost absent in the Russian-language philosophical literature, despite its exceptional importance due to both the level of development of nuclear energy in Russia and the potential risks that these technologies pose to current and future generations of both employees of nuclear facilities and the population of the country, neighboring countries, and the world. The purpose of this article, thus, is to initiate such a discussion.

ethics of science and technology↗

Hydropower representation in water and energy system models: a review of divergences and call for reconciliation

Abstract Reservoir-based hydropower systems represent key interactions between water and energy systems and are being transformed under policy initiatives driven by increasing water and energy demand, the desire to reduce environmental impacts, and interacting effects of climate change. Such policies are often guided by complex system models, whereby divergence in system representations can potentially translate to incompatible planning outcomes, thereby undermining any planning that may rely on them. We review different approaches and assumptions in hydropower representation in water and energy systems. While the models and issues are relevant globally, the review focuses on applications in California given its extensive development of energy and water models for policy planning, but discusses the extent to which these observations apply to other regions. Structurally, both water-driven and energy-driven management models are similar. However, in energy models, hydropower is often represented as a single-priority output. Water management models typically allocate water for competing priorities, which are generally uninformed by dynamic electricity load demand, and often result in a lower priority for hydropower. In water models, constraints are increasingly resolved for non-energy components (e.g. inflow hydrology and non-energy water demand); few analogues exist for energy models. These limitations may result in inadequate representations of each respective sector, and vastly different planning outcomes for the same facilities between the two different sectors. These divergent modeling approaches manifest themselves in California where poorly reconciled outcomes may affect decisions in hydropower licensing, electricity grid flexibility and decarbonization, and planning for environmental water. Fully integrated water-energy models are computationally intensive and specific to certain regions, but better representation of each domain in respective efforts would help reconcile divergences in planning and management efforts related to hydropower across energy and water systems.

Rheinheimer, David E. (ORCID:0000000315259069)↗