Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Experimental Investigation of a Multiplex Fuel Injector Module With Discrete Jet Swirlers for Low Emission Combustors

A low-NOx emissions combustor concept has been demonstrated in flame-tube tests. A lean-direct injection (LDI) concept was used where the fuel is injected directly into the flame zone and the overall equivalence ratio of the mixture is lean. The LDI concept described in this report is a multiplex fuel injector module containing multipoint fuel injection tips and multi-burning zones. The injector module comprises 25 equally spaced injection tips within a 76 by 76 mm area that fits into the flame-tube duct. The air swirlers were made from a concave plate on the axis of the fuel injector using drilled holes at an angle to the axis of the fuel injector. The NOx levels were quite low and are greater than 70 percent lower than the 1996 ICAO standard. At an inlet temperature of 810 K, inlet pressure of 2760 kPa, pressure drop of 4 percent and a flame temperature of 1900 K with JP8 fuel, the NOx emission index was 9. The 25-point injector module exhibited the most uniform radial distribution of fuel-air mixture and NOx emissions in the flame tube when compared to other multipoint injection devices. A correlation is developed relating the NOx emissions to inlet temperature, inlet pressure, equivalence ratio and pressure drop.

Tacina, Robert↗

Human sympathetic and vagal baroreflex responses to sequential nitroprusside and phenylephrine

We evaluated a method of baroreflex testing involving sequential intravenous bolus injections of nitroprusside followed by phenylephrine and phenylephrine followed by nitroprusside in 18 healthy men and women, and we drew inferences regarding human sympathetic and vagal baroreflex mechanisms. We recorded the electrocardiogram, photoplethysmographic finger arterial pressure, and peroneal nerve muscle sympathetic activity. We then contrasted least squares linear regression slopes derived from the depressor (nitroprusside) and pressor (phenylephrine) phases with 1) slopes derived from spontaneous fluctuations of systolic arterial pressures and R-R intervals, and 2) baroreflex gain derived from cross-spectral analyses of systolic pressures and R-R intervals. We calculated sympathetic baroreflex gain from integrated muscle sympathetic nerve activity and diastolic pressures. We found that vagal baroreflex slopes are less when arterial pressures are falling than when they are rising and that this hysteresis exists over pressure ranges both below and above baseline levels. Although pharmacological and spontaneous vagal baroreflex responses correlate closely, pharmacological baroreflex slopes tend to be lower than those derived from spontaneous fluctuations. Sympathetic baroreflex slopes are similar when arterial pressure is falling and rising; however, small pressure elevations above baseline silence sympathetic motoneurons. Vagal, but not sympathetic baroreflex gains vary inversely with subjects' ages and their baseline arterial pressures. There is no correlation between sympathetic and vagal baroreflex gains. We recommend repeated sequential nitroprusside followed by phenylephrine doses as a simple, efficientmeans to provoke and characterize human vagal and sympathetic baroreflex responses.

NASA Discipline Cardiopulmonary↗

Swift Follow-Up Observations of Candidate Gravitational-Wave Transient Events

We present the first multi-wavelength follow-up observations of two candidate gravitational-wave (GW) transient events recorded by LIGO and Virgo in their 2009-2010 science run. The events were selected with low latency by the network of GW detectors (within less than 10 minutes) and their candidate sky locations were observed by the Swift observatory (within 12 hr). Image transient detection was used to analyze the collected electromagnetic data, which were found to be consistent with background. Off-line analysis of the GW data alone has also established that the selected GW events show no evidence of an astrophysical origin; one of them is consistent with background and the other one was a test, part of a "blind injection challenge." With this work we demonstrate the feasibility of rapid follow-ups of GW transients and establish the sensitivity improvement joint electromagnetic and GW observations could bring. This is a first step toward an electromagnetic follow-up program in the regime of routine detections with the advanced GW instruments expected within this decade. In that regime, multi-wavelength observations will play a significant role in completing the astrophysical identification of GW sources. We present the methods and results from this first combined analysis and discuss its implications in terms of sensitivity for the present and future instruments.

Evans, P. A.↗

Model-Based Verification and Validation of Spacecraft Avionics

Verification and Validation (V&V) at JPL is traditionally performed on flight or flight-like hardware running flight software. For some time, the complexity of avionics has increased exponentially while the time allocated for system integration and associated V&V testing has remained fixed. There is an increasing need to perform comprehensive system level V&V using modeling and simulation, and to use scarce hardware testing time to validate models; the norm for thermal and structural V&V for some time. Our approach extends model-based V&V to electronics and software through functional and structural models implemented in SysML. We develop component models of electronics and software that are validated by comparison with test results from actual equipment. The models are then simulated enabling a more complete set of test cases than possible on flight hardware. SysML simulations provide access and control of internal nodes that may not be available in physical systems. This is particularly helpful in testing fault protection behaviors when injecting faults is either not possible or potentially damaging to the hardware. We can also model both hardware and software behaviors in SysML, which allows us to simulate hardware and software interactions. With an integrated model and simulation capability we can evaluate the hardware and software interactions and identify problems sooner. The primary missing piece is validating SysML model correctness against hardware; this experiment demonstrated such an approach is possible.

MBV&V↗

Computational Flow Field in Energy Efficient Engine (EEE)

In this paper, preliminary results for the recently-updated Open National Combustion Code (Open NCC) as applied to the EEE are presented. The comparison between two different numerical schemes, the standard Jameson-Schmidt-Turkel (JST) scheme and the advection upstream splitting method (AUSM), is performed for the cold flow and the reacting flow calculations using the RANS. In the cold flow calculation, the AUSM scheme predicts a much stronger reverse flow in the central recirculation zone. In the reacting flow calculation, we test two cases: gaseous fuel injection and liquid spray injection. In the gaseous fuel injection case, the overall flame structures of the two schemes are similar to one another, in the sense that the flame is attached to the main nozzle, but is detached from the pilot nozzle. However, in the exit temperature profile, the AUSM scheme shows a more uniform profile than that of the JST scheme, which is close to the experimental data. In the liquid spray injection case, we expect different flame structures in this scenario. We will give a brief discussion on how two numerical schemes predict the flame structures inside the EEE using different ways to introduce the fuel injection.

CFD↗

Assessing mechanical response of CO 2 storage into a depleted carbonate reef using a site-scale geomechanical model calibrated with field tests and InSAR monitoring data

Geomechanical risks of injection have raised concerns regarding secure CO 2 storage. In this work, a combined monitoring and modeling approach is used to assess the stress changes and surface uplift associated with CO 2 injection into a depleted carbonate reef of the Michigan basin. A site-scale geomechanical model is built by assigning mechanical properties of formations using well-log and experimental data. Gravity load is applied to the model to estimate the vertical component of stress as well as different lateral boundary displacement scenarios to estimate horizontal stresses. We used a poroelastic pressure-dependent model (instead of a linear elastic mechanical earth model) to calibrate initial stresses using hydraulic fracture test data measured at depleted reservoir status. Multi-phase fluid flow-geomechanical simulations are performed to estimate the poroelastic response during (1) primary depletion (2) field-scale CO 2 injection phase (3) a hypothetical forecast scenario in which well bottom hole pressure (BHP) reach 45000 KPa. The predicted surface uplift is less than 1 mm at the end of the field-scale CO 2 injection phase which is in good agreement with Interferometric Synthetic Aperture Radar (InSAR) uplift measurement. Although the InSAR data shows an insignificant uplift, hydromechanical modeling of injection shows that CO 2 injection still causes reservoir deformation emphasizing the role of carbonate overburden and reservoir formation mechanical properties and limited size of reef on diminishing the surface deformation. Modeling indicates poroelastic response of caprock matters to estimate uplift. The lower permeability of the top two layers provides additional barrier to large uplift. Also, history of subsidence due to production should be accounted to predict uplift due to a follow up injection correctly. This report shows the significance of combining a calibrated geomechanical model with field measured stresses and monitoring data to be used as a tool to ensure the safety of CO 2 storage.

42 ENGINEERING↗

Modeling of three-dimensional mixing and reacting ducted flows

A computer code based on a finite-element solution algorithm is developed to perform an analytical investigation on the turbulent mixing and reaction of hydrogen jets injected from multiple orifices transverse and parallel to a supersonic airstream. A laser optical cavity flow field was also analyzed to demonstrate the generality of the proposed model. Computational results provide a three-dimensional description of velocity, temperature, and species-concentration fields downstream of injection. Major conclusions are that the analysis has immediate utility in evaluating the mixing effectiveness of transverse H2 injection data since it has been tested in its ability to model this type of data and that turbulent mixing length theory, constant effective Prandtl number, and a Lewis number of unity provide reasonable agreement with transverse H2 injection data downstream of the near-injection region. Efforts are presently being directed toward using the code in modeling laser and scramjet data for a wide range of flow conditions.

Zelazny, S. W.↗

BurstCube: Behind the Scenes of a Do-No-Harm I&T Production

BurstCube is one of the most recent 6-U CubeSats built and developed by NASA Goddard Spaceflight Center (GSFC). As an astrophysics mission, BurstCube will be a rapid detection alert end-to-end mission system for short astrophysical gamma-ray bursts with the aim of increasing the chance of coincident detection of gamma-ray bursts. In addition, the mission is intended to augment the current fleet of gamma-ray astronomy satellites. The payload instrument includes 4 scintillator heads read out by arrays of silicon photomultipliers which will detect short astrophysical gamma-ray bursts. BurstCube provides a high field of view previously unavailable to larger missions and is intended to provide rapid alerts for follow up observations with other assets, increasing the chance of a coincident detection of an event. From the design to the integration and test phases, the project aimed to provide realistic test plans and stimulus to help verify and validate reachable areas of this innovative payload/instrument system and even spacecraft performance. Typical robust integration and test phases for space missions are unaligned with the budget and risk postures of small satellite or CubeSat missions, often designated as “Do No Harm” projects where the primary requirement is not harming the host platform or other payloads. Despite this status, CubeSats are complex missions that mix new and prior technologies. Integration and test for these missions requires responsible engineering, creative collaboration, and careful observation to deliver a reliable mission. This paper will provide an overview of the payload instrument and mission system, areas of injected automation (current and future), environmental testing results, and lessons learned during the integration and test phase.

CubeSats↗

Laboratory simulations of the Viking Labeled Release experiment - Kinetics following second nutrient injection and the nature of the gaseous end product

Injection of (C-14)-labeled nutrient onto Mars soil produced an evolution of C-14 gas in the Viking Labeled Release (LR) experiment. However, a second injection of nutrient seven days later was followed by an abrupt diminution of the amount of radioactive gas in the test cell. Simulation experiments performed in the LR Test Standards Module (TSM) have yielded a plausible explanation for this diminution. Radioactive carbon gases were injected into the TSM test cell in the presence and absence of two Mars analog soils. After equilibration, water was injected and its effect observed. The results indicate that the flight data following second nutrient injection can be explained on a physico-chemical basis involving a carbon dioxide/water/soil equilibrium in the test cell. The results also suggest that the gaseous end product of the Labeled Release reaction on Mars is more likely carbon dioxide than carbon monoxide.

Levin, G. V.↗

From ETROC to VTROC

The Endcap Timing ReadOut Chip (ETROC) is designed to process LGAD signals with time resolution down to about 40-50ps per hit, to reach 30-35ps per track with two detector layers. The ETROC2 is the first full size (16x16) prototype design and is fully compatible with the final chip specifications in terms of functionality. The ETROC2 has been extensively tested recently. In this talk, the testing results of the ETROC2 will be presented first, including performance study using charge injection, laser and beam, as well as TID testing and wafer probe testing to study the yield. In addition, future challenges of precision position and timing ASIC design will be discussed, based on what we have learned from the ETROC development, and how the challenges could be addressed in the VTROC, Vertically integrated Timing ReadOut chip (funded as SBIR phase 2) for precision position and timing detector R&D.

Liu, Ted↗

Understanding syringeability and injectability of high molecular weight PEO solution through time-dependent force-distance profiles

Opioid medications play a vital role in treating moderate to severe pain. Unfortunately, many drug misusers and abusers attempt to alter the formulations or properties of these drugs by manipulation, (e.g., crushing, chewing, smoking, snorting, injecting). The intravenous (IV) route is most dangerous to abusers, as the drugs directly enter the circulatory system and produce intense euphoria. To obtain a full understanding of the impact of syringe factors (e.g., needle gauge size, needle length, syringe barrel size), on the ease of injection, we undertook a comprehensive assessment of syringeability and injectability of manipulated abuse-deterrent formulations (ADFs). A texture analyzer-based testing method was developed for the measurement of the resistance force of pulling, holding, and pushing phases of injections. Results showed that the finer needle gauge sizes required higher injection force to withdraw drug solutions. In addition, the syringed liquid volume was highly dependent on needle gauge size, holding time, and sample viscosity. In most cases, a lower needle gauge number and a longer holding time increased the syringed volume. Needle length was highly correlated to injection force (R 2 = 0.99). Using longer needles to inject drug solution requires greater force. Furthermore, large barrel size was correlated to pushing force (R 2 = 0.99); thus, increasing the difficulty of pushing the plunger of a large syringe with one hand. Lastly, relationships between injection force, sample viscosity, and testing conditions were elucidated using a mathematical model, which could be used in the future to assess and predict injection force of solution samples.

60 APPLIED LIFE SCIENCES↗

Spike-Nosed Bodies and Forward Injected Jets in Supersonic Flow

The paper contains new numerical simulation and experimental test results of blunt body drag reduction using thin spikes mounted in front of a body and one- or two-phase jets injected against a supersonic flow. Numerical simulations utilizing the NASA CFL3D code were conducted at the Hampton University Fluid Mechanics and Acoustics Laboratory (FM&AL) and experimental tests were conducted using the facilities of the IM/MSU Aeromechanics and Gas Dynamics Laboratory. Previous results were presented at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference. Those results were based on some experimental and numerical simulation tests for supersonic flow around spike-nosed or shell-nosed bodies, and numerical simulations were conducted only for a single spike-nosed or shell-nosed body at zero attack angle, alpha=0. In this paper, experimental test results of gas, liquid and solid particle jet injection against a supersonic flow are presented. In addition, numerical simulation results for supersonic flow around a multiple spike-nosed body with non-zero attack angles and with a gas and solid particle forward jet injection are included. Aerodynamic coefficients: drag, C(sub D), lift, C(sub L), and longitudinal momentum, M(sub z), obtained by numerical simulation and experimental tests are compared and show good agreement.

Gilinsky, M.↗

Spike-Nosed Bodies and Forward Injected Jets in Supersonic Flow

The paper contains new numerical simulation and experimental test results of blunt body drag reduction using thin spikes mounted in front of a body and one- or two-phase jets injected against a supersonic flow. Numerical simulations utilizing the NASA CFL3D code were conducted at the Hampton University Fluid Mechanics and Acoustics Laboratory (FM&AL) and experimental tests were conducted using the facilities of the IM/MSU Aeromechanics and Gas Dynamics Laboratory. Previous results were presented at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference. Those results were based on some experimental and numerical simulation tests for supersonic flow around spike-nosed or shell-nosed bodies, and numerical simulations were conducted only for a single spike-nosed or shell-nosed body at zero attack angle, alpha = 0 degrees. In this paper, experimental test results of gas, liquid and solid particle jet injection against a supersonic flow are presented. In addition, numerical simulation results for supersonic flow around a multiple spike-nosed body with non-zero attack angles and with a gas and solid particle forward jet injection are included. Aerodynamic coefficients: drag, C (sub D), lift, C(sub L), and longitudinal momentum, M(sub z), obtained by numerical simulation and experimental tests are compared and show good agreement.

Gilinsky, M.↗

Forecasting induced seismicity in Oklahoma using machine learning methods

Oklahoma earthquakes in the past decade have been mostly associated with wastewater injection. Here we use a machine learning technique—the Random Forest to forecast induced seismicity rate in Oklahoma based on injection-related parameters. We split the data into training (2011.01–2015.05) and test (2015.06–2020.12) periods. The model forecasts seismicity rate during the test period based on input features, including operational parameters (injection rate and pressure), geological information (depth to basement), and modeled pore pressure and poroelastic stress. The results show overall good match with observed seismicity rate (adjusted R 2 of 0.75). The model shows that pore pressure rate and poroelastic stressing rates are the two most important features in forecasting. The absolute values of pore pressure and poroelastic stress, and the injection rate itself, are less important than the stressing rates. These findings further emphasize that temporal changes of stressing rates would lead to significant changes in seismicity rates.

58 GEOSCIENCES↗

Effect of water injection on nitric oxide emissions of a gas turbine combustor burning natural gas fuel

The effect of direct water injection on the exhaust gas emissions of a turbojet combustor burning natural gas fuel was investigated. The results are compared with the results from similar tests using ASTM Jet-A fuel. Increasing water injection decreased the emissions of oxides of nitrogen (NOX) and increased the emissions of carbon monoxide and unburned hydrocarbons. The greatest percentage decrease in NOX with increasing water injection was at the lowest inlet-air temperature tested. The effect of increasing inlet-air temperature was to decrease the effect of the water injection. The reduction in NOX due to water injection was almost identical to the results obtained with Jet-A fuel. However, the emission indices of unburned hydrocarbons, carbon monoxide, and percentage nitric oxide in NOX were not.

Marchionna, N. R.↗

Autogenic-feedback training exercise is superior to promethazine for control of motion sickness symptoms

Motion sickness symptoms affect approximately 50% of the crew during space travel and are commonly treated with intramuscular injections of promethazine. The purpose of this paper is to compare the effectiveness of three treatments for motion sickness: intramuscular injections (i.m.) of promethazine, a physiological training method (autogenic-feedback training exercise [AFTE]), and a no-treatment control. An earlier study tested the effects of promethazine on cognitive and psychomotor performance and motion sickness tolerance in a rotating chair. For the present paper, motion sickness tolerance, symptom reports, and physiological responses of these subjects were compared to matched subjects selected from an existing database who received either AFTE or no treatment. Three groups of 11 men, between the ages of 33 and 40 years, were matched on the number of rotations tolerated during their initial rotating-chair motion sickness test. The motion sickness test procedures and the 7-day interval between tests were the same for all subjects. The drug group was tested under four treatment conditions: baseline (no injections), a 25 mg dose of promethazine, a 50 mg dose of promethazine, and a placebo of sterile saline. AFTE subjects were given four 30-minute AFTE sessions before their second, third, and fourth motion sickness tests (6 hours total). The no-treatment control subjects were only given the four rotating-chair tests. Motion sickness tolerance was significantly increased after 4 hours of AFTE when compared to either 25 mg (p < 0.00003) or 50 mg (p < 0.00001) of promethazine. The control and promethazine groups did not differ. AFTE subjects reported fewer or no symptoms at higher rotational velocities than subjects in the control or promethazine groups. The primary physiological effect of promethazine was an inhibition of skin conductance level. The AFTE group showed significantly less heart rate and skin conductance variability during motion sickness tests administered after training.

Clinical Trial↗

Static Flow Characteristics of a Mass Flow Injecting Valve

A sleeve valve is under development for ground-based forced response testing of air compression systems. This valve will be used to inject air and to impart momentum to the flow inside the first stage of a multi-stage compressor. The valve was designed to deliver a maximum mass flow of 0.22 lbm/s (0.1 kg/s) with a maximum valve throat area of 0.12 sq. in (80 sq. mm), a 100 psid (689 KPA) pressure difference across the valve and a 68 F, (20 C) air supply. It was assumed that the valve mass flow rate would be proportional to the valve orifice area. A static flow calibration revealed a nonlinear valve orifice area to mass flow relationship which limits the maximum flow rate that the valve can deliver. This nonlinearity was found to be caused by multiple choking points in the flow path. A simple model was used to explain this nonlinearity and the model was compared to the static flow calibration data. Only steady flow data is presented here. In this report, the static flow characteristics of a proportionally controlled sleeve valve are modelled and validated against experimental data.

Mattern, Duane↗

Charge injection device evaluation hardware

A microprocessor based system which provides maximum testing flexibility via software reconfiguration is described. This system has the capability to evaluate a charge injection device (CID) and to characterize its performance. The construction and operation of the CID offer advantages over the various CCD configurations available. These advantages include a less sophisticated manufacturing process, no images smearing during readout, high transfer efficiencies, and high resistance to blooming due to optical overload.

Source record↗