Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “information commons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Enhanced Multi-Dimensional Inversion Through Target-Specific Inversion Parameter Bounds With an Application to Crosswell Electromagnetic for Sequestration Monitoring

In geophysical inversions, lower and upper model parameter bounds are a means of solution stabilization. Further, constraints that intend to let only geologically plausible inverse solutions pass are amenable to lower and upper bounds. Reliable prior information is paramount to construct such bound constraints. It is common practice to narrow and widen bound intervals for regions of, respectively, more and less certain prior information. Contrary to this practice, we experiment with widened bound intervals in zones that are poorly resolved by a given survey configuration but where prior information would suggest structural anomalies of interest. The purpose of enlarged parameter bounds that correlate spatially with predefined targets is to let the inversion explore a larger solution space, thus increasing the potential to resolve otherwise hidden anomalies. Application of the method is based on a carbon-sequestration baseline (pre-injection) crosswell electromagnetic (EM) field survey at the Containment and Monitoring Institute Field Research Station (Alberta, Canada), where impeded measurements led to generally reduced sensitivities for the interwell region. Synthetic-data proofs of concept use augmented bounds designed to boost the resolution of artificial plume targets, indicating an enhanced illumination compared to constant bounds. Comparative field data inversions with spatially variable bounds constructed from prior resistivity and velocity information highlight non-horizontal baseline structures.

3-D electrical resistivity imaging↗

A Common Lunar Lander (CLL) for the Space Exploration Initiative

Information is given in viewgraph form on the Artemis project, a plan to establish a permanent base on the Moon. Information includes a summary of past and future events, the program rationale, a summary of potential payloads, the physical characteristics of experiments, sketches of equipment, design study objectives, and details of such payloads as the Geophysical Station Network, teleoperated rovers, astronomical telescopes, a Moon-Earth radio interferometer, very low frequency radio antennas, the Lunar Polar Crater Telescope, Lunar Resource Utilization Experiments, and biological experiments.

Bailey, Stephen↗

Commercial Smallsat Data Acquisition Program: Airbus U.S. Synthetic Aperture Radar Quality Assessment Summary

Quality assessment of the Airbus X-band Synthetic Aperture Radar (SAR) satellite products was conducted by the Commercial Smallsat Data Acquisition (CSDA) program’s radar subject matter experts, following the Joint NASA/ESA (European Space Agency) assessment draft guidelines. All three Airbus SAR spacecraft (TerraSAR-X, TanDEM-X, and PAZ) are based on the TerraSAR-X platform, and each have an active phased array antenna that is 4.8 x 0.7 m in the along-track and cross-track dimensions, respectively. TerraSAR-X and TanDEM-X are in a helical orbit, creating a bistatic imaging geometry, in addition to being capable of independent monostatic observations. The PAZ mission follows TerraSAR-X and TanDEM-X in the same 11-day orbit with a 5.5-day lag. TerraSAR-X and TanDEM-X are designed, developed, and operated through a Public-Private Partnership, while PAZ is a dual-use mission (civil and defense agencies), funded and owned by the Spanish Ministry of Defense and managed by Hisdesat (Hisdesat Servicios Estratégicos, S.A.), a Spanish private communications company. The assessment presented in this document is divided into two main parts: documentation review and the assessment of test datasets. The documentation review in sections 2.1 through 2.4 includes the assessment of the Airbus documentation provided to the CSDA evaluation team. The grading of these documents is given in columns 1-4 of the maturity matrix shown in section 1.1. Section 2.5 summarizes the evaluation performed by NASA using the data purchased through the CSDA program. The grading for this is given in the last column of the maturity matrix. Section 3 provides more detailed explanations on the methods and the results of the data analysis performed by NASA. Only the documents provided by Airbus for the evaluation were considered for the review. Additional documentation with more detailed description of the calibration and validation procedures may be available online but were not considered for this evaluation. The product information provided in the available documentation (RD-1, RD-2) and the product metadata together provided adequate information to work with the data. The product details in the metadata included the required information to work with the data in the common XML file format. Metrological traceability documentation was not provided to CSDA. All relevant characterization of the SAR system and data were provided, and the metadata include all relevant ancillary information. Documentation provided to CSDA included limited pre-flight and post-launch calibration information.

Batuhan Osmanoglu↗

A Principled Framework to Assess the Information-Theoretic Fitness of Brain Functional Sub-Circuits

In systems and network neuroscience, many common practices in brain connectomic analysis are often not properly scrutinized. One such practice is mapping a predetermined set of sub-circuits, like functional networks (FNs), onto subjects’ functional connectomes (FCs) without adequately assessing the information-theoretic appropriateness of the partition. Another practice that goes unchallenged is thresholding weighted FCs to remove spurious connections without justifying the chosen threshold. This paper leverages recent theoretical advances in Stochastic Block Models (SBMs) to formally define and quantify the information-theoretic fitness (e.g., prominence) of a predetermined set of FNs when mapped to individual FCs under different fMRI task conditions. Our framework allows for evaluating any combination of FC granularity, FN partition, and thresholding strategy, thereby optimizing these choices to preserve the important topological features of the human brain connectomes. By applying to the Human Connectome Project with Schaefer parcellations at multiple levels of granularity, the framework showed that the common thresholding value of 0.25 was indeed information-theoretically valid for group-average FCs, despite its previous lack of justification. Our results pave the way for the proper use of FNs and thresholding methods, and provide insights for future research in individualized parcellations.

Duong-Tran, Duy (ORCID:0009000944967575)↗

Evaluating the ProtoDUNE-SP Detector Performance to Measure a 6 GeV/c Positive Kaon Inelastic Cross Section on Argon

The ProtoDUNE Single-Phase Liquid Argon Time Projection Chamber \\ (ProtoDUNE-SP LArTPC) is a prototype for the Deep Underground Neutrino Experiment (DUNE), a future long-baseline neutrino oscillation experiment. Based at the CERN Neutrino Platform, ProtoDUNE-SP LArTPC collected data from a charged test beam in the fall of 2018. It then took data of cosmic-ray muons from November 2018 to the summer of 2020. The main goals of the prototype were to measure parameters related to charged particle passage in argon and evaluate the performance of the detector to inform future DUNE Far Detector development. The test beam provided kaons, pions, muons, protons, and electrons to the detector. These particles represent common final state particles in neutrino interactions, therefore providing information to DUNE on modeling charged particles in argon for its neutrino physics program. In addition to neutrino physics, DUNE has proposed an analysis using the DUNE Far Detector module to set limits for proton decay through the decay channel $p\rightarrow K^++\bar{\nu}$. This measurement would require information on kaons in argon, providing ProtoDUNE-SP LArTPC another opportunity to aid DUNE. This thesis describes the calibration of ProtoDUNE-SP and its detector performance, which serves as a benchmark for the performance of the DUNE Far Detector modules. A specific calibration highlighted is the evaluation of the liquid argon purity in the detector. These measurements use cosmic-ray muons reconstructed in the detector that are calibrated and matched to data from scintillator strips external to the TPC, known as the Cosmic Ray Tagger (CRT). The thesis will discuss the algorithms to match the data between the ProtoDUNE-SP LArTPC and the CRT and discuss the liquid argon purity measurements using one of the algorithms. Data sets of calibrated tracks measured the liquid argon contamination as consistently below 100 ppt oxygen equivalent. After these discussions on the ProtoDUNE-SP LArTPC detector, the thesis will present an evaluation of the inclusive inelastic, sometimes referred to as a reactive, cross section on argon of kaons from the ProtoDUNE-SP test beam with an average momentum of 6 GeV/c.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ModuleOT: A Hardware Security Module for Operational Technology: Preprint

With increasing penetration levels of distributed energy resources (DERs) on the distribution grid, as well as new technological advancements in the cyber space, new cyberattack vectors are being introduced, and the available attack surface is constantly increasing. Despite this increasing risk, the standard IEEE 1547-2018 does not yet recommend cybersecurity measures for DERs. To address this and to better protect data on the distribution grid - from the standpoints information security as well as operational security - ModuleOT has been developed. The module aims to significantly reduce cyberattack vectors by improving data privacy for user applications. This is accomplished by performing the core functions of encryption, authentication, authorization, certificate management, and user access control. The module integrates a custom security application with hardware cryptographic acceleration. The application secures all communications using Transmission Control Protocol over Internet Protocol (TCP/IP). These include the three most commonly used communications protocols for power systems information exchange: Modbus, Distributed Network Protocol 3 (DNP3), and Smart Energy Profile 2.0 (SEP2.0). These three protocols are also supported by IEEE 1547-2018 for all DER devices. This paper tests the data encryption/decryption feature on a physical networking test bed with emulated Modbus devices reporting grid data and presents the results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Sequence Analysis of Multidrug-Resistant IncA/C Plasmids from Salmonella enterica

Determinants of multidrug resistance (MDR) are often encoded on mobile elements, such as plasmids, transposons, and integrons, which have the potential to transfer among foodborne pathogens, as well as to other virulent pathogens, increasing the threats these traits pose to human and veterinary health. Our understanding of MDR among Salmonella has been limited by the lack of closed plasmid genomes for comparisons across resistance phenotypes, due to difficulties in effectively separating the DNA of these high-molecular weight, low-copy-number plasmids from chromosomal DNA. To resolve this problem, we demonstrate an efficient protocol for isolating, sequencing and closing IncA/C plasmids from Salmonella sp. using single molecule real-time sequencing on a Pacific Biosciences (Pacbio) RS II Sequencer. We obtained six Salmonella enterica isolates from poultry, representing six different serovars, each exhibiting the MDR-Ampc resistance profile. Salmonella plasmids were obtained using a modified mini preparation and transformed with Escherichia coli DH10Br. A Qiagen Large-Construct kitTM was used to recover highly concentrated and purified plasmid DNA that was sequenced using PacBio technology. These six closed IncA/C plasmids ranged in size from 104 to 191 kb and shared a stable, conserved backbone containing 98 core genes, with only six differences among those core genes. The plasmids encoded a number of antimicrobial resistance genes, including those for quaternary ammonium compounds and mercury. We then compared our six IncA/C plasmid sequences: first with 14 IncA/C plasmids derived from S. enterica available at the National Center for Biotechnology Information (NCBI), and then with an additional 38 IncA/C plasmids derived from different taxa. These comparisons allowed us to build an evolutionary picture of how antimicrobial resistance may be mediated by this common plasmid backbone. Our project provides detailed genetic information about resistance genes in plasmids, advances in plasmid sequencing, and phylogenetic analyses, and important insights about how MDR evolution occurs across diverse serotypes from different animal sources, particularly in agricultural settings where antimicrobial drug use practices vary.

59 BASIC BIOLOGICAL SCIENCES↗

Relations between information system engineering and software engineering

This paper examines some of the relations between information system engineering and software engineering. A model for the development process of an information system is presented that focuses on problems common to both disciplines. The concepts of complexity, multiplicity of view, distortion in communication, and concurrency and iteration in implementation are treated. A set of design constructs for the description of an information system is presented. The role of project management is treated. The issue of how to characterize requirements analysis is answered by making it a design activity from the point of view of a user of the product system.

Callender, E. D.↗

Clinical pharmacology information in regulatory submissions and labeling: A comparative analysis of orphan and non-orphan drugs approved by the FDA

Clinical pharmacology is an integral discipline supporting the development, regulatory evaluation, and clinical use of drugs for the treatment of both common and rare diseases. Here, we evaluated the recommendations and information available from select clinical pharmacology studies in the therapeutic product labeling of new molecular entities (NMEs) approved from 2017 to 2019 for both common and rare diseases. A total of 151 NMEs, including 72 orphan and 79 non-orphan drugs, were analyzed for recommendations and information available related to food–drug interaction, drug–drug interaction, renal impairment, hepatic impairment, QT assessment, and human radiolabeled mass balance studies using data collected from the original labeling and other regulatory documents. The analysis showed no statistically significant difference in the recommendations between orphan and non-orphan drugs except for renal impairment related recommendations in section 8 of the labeling. Although not significant, fewer hepatic impairment labeling recommendations were available for orphan drugs when compared with non-orphan drugs. At the time of initial approval, 79 postmarketing requirements (PMRs) and postmarketing commitments (PMCs) for 33 orphan drugs and 39 PMRs and PMCs for 19 non-orphan drugs were established; with most difference observed for drug–drug interaction, hepatic impairment, and QT assessment. Overall, although there was a trend for more labeling recommendations and fewer postmarketing studies and clinical trials for non-orphan drugs, there appeared to be no substantial differences in how these select clinical pharmacology studies are leveraged during the development and approval of orphan and non-orphan drugs.

60 APPLIED LIFE SCIENCES↗

Cyber security analysis testbed : combining real, emulation, and simulation.

Cyber security analysis tools are necessary to evaluate the security, reliability, and resilience of networked information systems against cyber attack. It is common practice in modern cyber security analysis to separately utilize real systems of computers, routers, switches, firewalls, computer emulations (e.g., virtual machines) and simulation models to analyze the interplay between cyber threats and safeguards. In contrast, Sandia National Laboratories has developed novel methods to combine these evaluation platforms into a hybrid testbed that combines real, emulated, and simulated components. The combination of real, emulated, and simulated components enables the analysis of security features and components of a networked information system. When performing cyber security analysis on a system of interest, it is critical to realistically represent the subject security components in high fidelity. In some experiments, the security component may be the actual hardware and software with all the surrounding components represented in simulation or with surrogate devices. Sandia National Laboratories has developed a cyber testbed that combines modeling and simulation capabilities with virtual machines and real devices to represent, in varying fidelity, secure networked information system architectures and devices. Using this capability, secure networked information system architectures can be represented in our testbed on a single, unified computing platform. This provides an 'experiment-in-a-box' capability. The result is rapidly-produced, large-scale, relatively low-cost, multi-fidelity representations of networked information systems. These representations enable analysts to quickly investigate cyber threats and test protection approaches and configurations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Comprehensive, Quantitative Risk Assessment of CO 2 Geologic Sequestration (Final Technical Report)

A Quantitative Failure Modes and Effects Analysis (QFMEA) was developed to conduct comprehensive, quantitative risk assessments on CO 2 capture, transportation, and sequestration or use in deep saline aquifers, enhanced oil recovery operations, or enhanced coal bed methane operations. The model identifies and characterizes potential risks; identifies the likely failure modes, causes, effects and methods of detection; lists possible risk prevention and risk mitigation steps; estimates potential damage recovery costs, mitigation costs and costs savings resulting from mitigation; and ranks (prioritizes) risks according to the probability of failure, the severity of failure, the difficulty of early failure detection and the potential for fatalities. The QFMEA model generates the necessary information needed for effective project risk management. Diverse project information can be integrated into a concise, common format that allows comprehensive, quantitative analysis, by a cross-functional team of experts, to determine: What can possibly go wrong? How much will damage recovery cost? How can it be prevented or mitigated? What is the cost savings or benefit of prevention or mitigation? Which risks should be given highest priority for resolution? The QFMEA model can be tailored to specific projects and is applicable to new projects as well as mature projects. The model can be revised and updated as new information comes available. It accepts input from multiple sources, such as literature searches, site characterization, field data, computer simulations, analogues, process influence diagrams, probability density functions, financial analysis models, cost factors, and heuristic best practices manuals, and converts the information into a standardized format in an Excel spreadsheet. Process influence diagrams, geologic models, financial models, cost factors and an insurance schedule were developed to support the QFMEA model. Comprehensive, quantitative risk assessments were conducted on three (3) sites using the QFMEA model: (1) SACROC Northern Platform CO 2 -EOR Site in the Permian Basin, Scurry County, TX, (2) Pump Canyon CO 2 -ECBM Site in the San Juan Basin, San Juan County, NM, and (3) Farnsworth Unit CO 2 -EOR Site in the Anadarko Basin, Ochiltree County, TX. The sites were sufficiently different from each other to test the robustness of the QFMEA model.

54 ENVIRONMENTAL SCIENCES↗

Multifidelity deep operator networks for data-driven and physics-informed problems

Operator learning for complex nonlinear systems is increasingly common in modeling multi-physics and multi-scale systems. However, training such high-dimensional operators requires a large amount of expensive, high-fidelity data, either from experiments or simulations. In this work, we present a composite Deep Operator Network (DeepONet) for learning using two datasets with different levels of fidelity to accurately learn complex operators when sufficient high-fidelity data is not available. Additionally, we demonstrate that the presence of low-fidelity data can improve the predictions of physics-informed learning with DeepONets. We demonstrate the new multi-fidelity training in diverse examples, including modeling of the ice-sheet dynamics of the Humboldt glacier, Greenland, using two different fidelity models and also using the same physical model at two different resolutions.

97 MATHEMATICS AND COMPUTING↗

A parametric SPICE model for the simulation of spark gap switches

The use of SPICE-based software for the simulation of pulsed power systems—even large complex systems—has become commonplace in the pulsed power community. This is in contrast to earlier work in the field that relied on specially developed simulation codes such as Sandia’s Screamer or the Navy Research Lab’s Bertha, which natively incorporated models for common pulsed power components such as spark gap switches. Unlike these programs, SPICE programs provide a simple and familiar user interface and wide availability. However, SPICE programs do not include realistic models for key pulsed power circuit devices—including the spark gap switch. While simple switch models do exist in SPICE programs, these can only crudely approximate the behavior of a spark gap. This effort focuses on developing an SPICE circuit model for a gas-filled spark gap switch that is physically realistic while being simple enough to permit simulations to run in reasonable times on typical personal computers. Detailed information is provided for implementation in two common versions of SPICE: LTspice and Orcad PSPICE. Adaptation to other SPICE programs is possible with minimal modification. The model is intended as a design tool that uses physical parameters as inputs to connect it directly to the development of useable pulsed power systems. Data collected from the operation of a high-pressure pulsed-charged switch and a complete 12-stage Marx generator have been used to demonstrate the implementation and accuracy of the model over a wide range of parameters.

Pouncey, J. Cameron (ORCID:0000000153500816)↗

Bringing "Scientific Expeditions" into the Schools

Schools can obtain scientific information over the information superhighway. However, information suppliers use formats that permit access and analysis by the "least common denominator" tools for access and analysis. The result: most sources of dynamic representations of science are in the format of flat movies. We can shorten the time to get the "scientific expeditions" into schools and provide a unifying focus to vendors and information suppliers by establishing a target and goals for the "least common denominator" for tools to be used to access and analyze information over the information superhighway.

Watson, Val↗

Image gathering and coding for digital restoration: Information efficiency and visual quality

Image gathering and coding are commonly treated as tasks separate from each other and from the digital processing used to restore and enhance the images. The goal is to develop a method that allows us to assess quantitatively the combined performance of image gathering and coding for the digital restoration of images with high visual quality. Digital restoration is often interactive because visual quality depends on perceptual rather than mathematical considerations, and these considerations vary with the target, the application, and the observer. The approach is based on the theoretical treatment of image gathering as a communication channel (J. Opt. Soc. Am. A2, 1644(1985);5,285(1988). Initial results suggest that the practical upper limit of the information contained in the acquired image data range typically from approximately 2 to 4 binary information units (bifs) per sample, depending on the design of the image-gathering system. The associated information efficiency of the transmitted data (i.e., the ratio of information over data) ranges typically from approximately 0.3 to 0.5 bif per bit without coding to approximately 0.5 to 0.9 bif per bit with lossless predictive compression and Huffman coding. The visual quality that can be attained with interactive image restoration improves perceptibly as the available information increases to approximately 3 bifs per sample. However, the perceptual improvements that can be attained with further increases in information are very subtle and depend on the target and the desired enhancement.

Huck, Friedrich O.↗

Integrating Empirical-Modeling Approaches to Improve Understanding of Terrestrial Ecology Processes

Recent decades have seen tremendous increases in the quantity of empirical ecological data collected by individual investigators, as well as through research networks such as FLUXNET (Baldocchi et al., 2001). At the same time, advances in computer technology have facilitated the development and implementation of large and complex land surface and ecological process models. Separately, each of these information streams provides useful, but imperfect information about ecosystems. To develop the best scientific understanding of ecological processes, and most accurately predict how ecosystems may cope with global change, integration of empirical and modeling approaches is necessary. However, true integration - in which models inform empirical research, which in turn informs models (Fig. 1) - is not yet common in ecological research (Luo et al., 2011). The goal of this workshop, sponsored by the Department of Energy, Office of Science, Biological and Environmental Research (BER) program, was to bring together members of the empirical and modeling communities to exchange ideas and discuss scientific practices for increasing empirical - model integration, and to explore infrastructure and/or virtual network needs for institutionalizing empirical - model integration (Yiqi Luo, University of Oklahoma, Norman, OK, USA). The workshop included presentations and small group discussions that covered topics ranging from model-assisted experimental design to data driven modeling (e.g. benchmarking and data assimilation) to infrastructure needs for empirical - model integration. Ultimately, three central questions emerged. How can models be used to inform experiments and observations? How can experimental and observational results be used to inform models? What are effective strategies to promote empirical - model integration?

54 ENVIRONMENTAL SCIENCES↗

TH-E-18A-01: Developments in Monte Carlo Methods for Medical Imaging

Monte Carlo simulation methods are widely used in medical physics research and are starting to be implemented in clinical applications such as radiation therapy planning systems. Monte Carlo simulations offer the capability to accurately estimate quantities of interest that are challenging to measure experimentally while taking into account the realistic anatomy of an individual patient. Traditionally, practical application of Monte Carlo simulation codes in diagnostic imaging was limited by the need for large computational resources or long execution times. However, recent advancements in high-performance computing hardware, combined with a new generation of Monte Carlo simulation algorithms and novel postprocessing methods, are allowing for the computation of relevant imaging parameters of interest such as patient organ doses and scatter-to-primaryratios in radiographic projections in just a few seconds using affordable computational resources. Programmable Graphics Processing Units (GPUs), for example, provide a convenient, affordable platform for parallelized Monte Carlo executions that yield simulation times on the order of 10{sup 7} xray/ s. Even with GPU acceleration, however, Monte Carlo simulation times can be prohibitive for routine clinical practice. To reduce simulation times further, variance reduction techniques can be used to alter the probabilistic models underlying the x-ray tracking process, resulting in lower variance in the results without biasing the estimates. Other complementary strategies for further reductions in computation time are denoising of the Monte Carlo estimates and estimating (scoring) the quantity of interest at a sparse set of sampling locations (e.g. at a small number of detector pixels in a scatter simulation) followed by interpolation. Beyond reduction of the computational resources required for performing Monte Carlo simulations in medical imaging, the use of accurate representations of patient anatomy is crucial to the virtual generation of medical images and accurate estimation of radiation dose and other imaging parameters. For this, detailed computational phantoms of the patient anatomy must be utilized and implemented within the radiation transport code. Computational phantoms presently come in one of three format types, and in one of four morphometric categories. Format types include stylized (mathematical equation-based), voxel (segmented CT/MR images), and hybrid (NURBS and polygon mesh surfaces). Morphometric categories include reference (small library of phantoms by age at 50th height/weight percentile), patient-dependent (larger library of phantoms at various combinations of height/weight percentiles), patient-sculpted (phantoms altered to match the patient's unique outer body contour), and finally, patient-specific (an exact representation of the patient with respect to both body contour and internal anatomy). The existence and availability of these phantoms represents a very important advance for the simulation of realistic medical imaging applications using Monte Carlo methods. New Monte Carlo simulation codes need to be thoroughly validated before they can be used to perform novel research. Ideally, the validation process would involve comparison of results with those of an experimental measurement, but accurate replication of experimental conditions can be very challenging. It is very common to validate new Monte Carlo simulations by replicating previously published simulation results of similar experiments. This process, however, is commonly problematic due to the lack of sufficient information in the published reports of previous work so as to be able to replicate the simulation in detail. To aid in this process, the AAPM Task Group 195 prepared a report in which six different imaging research experiments commonly performed using Monte Carlo simulations are described and their results provided. The simulation conditions of all six cases are provided in full detail, with all necessary data on material composition, source, geometry, scoring and other parameters provided. The results of these simulations when performed with the four most common publicly available Monte Carlo packages are also provided in tabular form. The Task Group 195 Report will be useful for researchers needing to validate their Monte Carlo work, and for trainees needing to learn Monte Carlo simulation methods. In this symposium we will review the recent advancements in highperformance computing hardware enabling the reduction in computational resources needed for Monte Carlo simulations in medical imaging. We will review variance reduction techniques commonly applied in Monte Carlo simulations of medical imaging systems and present implementation strategies for efficient combination of these techniques with GPU acceleration. Trade-offs involved in Monte Carlo acceleration by means of denoising and “sparse sampling” will be discussed. A method for rapid scatter correction in cone-beam CT (<5 min/scan) will be presented as an illustration of the simulation speeds achievable with optimized Monte Carlo simulations. We will also discuss the development, availability, and capability of the various combinations of computational phantoms for Monte Carlo simulation of medical imaging systems. Finally, we will review some examples of experimental validation of Monte Carlo simulations and will present the AAPM Task Group 195 Report. Learning Objectives: Describe the advances in hardware available for performing Monte Carlo simulations in high performance computing environments. Explain variance reduction, denoising and sparse sampling techniques available for reduction of computational time needed for Monte Carlo simulations of medical imaging. List and compare the computational anthropomorphic phantoms currently available for more accurate assessment of medical imaging parameters in Monte Carlo simulations. Describe experimental methods used for validation of Monte Carlo simulations in medical imaging. Describe the AAPM Task Group 195 Report and its use for validation and teaching of Monte Carlo simulations in medical imaging.

60 APPLIED LIFE SCIENCES↗

Standardizng Data

To enable the rational design of nanomaterials for improved efficacy and safety, it is critical to understand and exploit the physicochemical properties that drive biological behavior (Morris, 2010). Data mining and computer simulation are essential for deriving information about nanomaterial behavior; however, the datasets needed to support such studies are sparse and stored across a variety of repositories and resources. Schrurs and Lison (2012) have expressed the need for more coherence and structure in the conduct of nanotechnology research. Additionally, the lack of common reporting standards and non-uniformity of information reported have proven to be significant barriers to such data sharing and re-use. The Nanotechnology Working Group (Nano WG), of the US National Institutes of Health National Cancer Informatics Program, has been focused on addressing these barriers. The Nano WG - which includes representatives from over 20 organizations including government agencies, academia, industry, standards organizations, and alliances -has developed ISA-TAB-Nano (Thomas et al, 2013), a general framework for representing and integrating diverse types of data related to the description and characterization of nanomaterials. Recognizing that nanoparticle characterization studies have many of the same challenges as ‘omics-based assays, the Nano WG joined the ISA Commons (Sansone et al., 2012) to leverage lessons learned in ‘omics data sharing. The ISA Commons community brings together 50 collaborators at over 30 scientific organizations around the globe, including regulatory and industrial participants in an increasingly diverse set of life science domains. At the core of the ISA Commons is the ISA metadata tracking framework which forms the basis for the ISA-TAB-Nano extension. The extension of the ISA framework to nanotechnology domain illustrates the power of a synergistic approach that seeks the interoperability of data across multiple research disciplines. To increase adoption, especially in the commercial arena from vendors and manufactures, the ISA-Tab-Nano data-sharing specification has also been submitted for consideration as a standard to the American Society for Testing and Materials (ASTM). Delivering a community-driven specification is only the first phase of the process. To be useful and used, ISA-TAB-Nano must be implemented by tools and databases to assist researchers in reporting their data accordingly, shielding them from unnecessary complexity. Our next step is to extend the open source ISA Software Suite to provide user-oriented tools for the collection, curation, and storage of data compliant with the ISA-TAB-Nano specification. Future work will also focus on the application of the ISA-TAB-Nano format to support emerging standards on minimal information about nanomaterials in biological research (Ostraat et al, 2012; MinChar). ISA-TAB-Nano development is a community-driven effort and we welcome new contributions, collaborations and domain expertise. We invite researchers, software developers, vendors, and other stakeholders to work with us to implement the ISA-Tab-Nano format in their existing systems and research. Likewise, we welcome engagement of regulators, funding agencies, editors, and other policy makers to discuss how this standard can be used to facilitate the sharing and reuse of nanotechnology data across a wide range of disciplines. More information about the ISA-TAB-Nano project can be found online at https://wiki.nci.nih.gov/display/ICR/ISA-TAB-Nano.

informatics↗