Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Microscopic Visualization of Cell-Cell Adhesion Complexes at Micro and Nanoscale

Considerable progress has been made in our knowledge of the morphological and functional varieties of anchoring junctions. Cell-cell adhesion contacts consist of discrete junctional structures responsible for the mechanical coupling of cytoskeletons and allow the transmission of mechanical signals across the cell collective. The three main adhesion complexes are adherens junctions, tight junctions, and desmosomes. Microscopy has played a fundamental role in understanding these adhesion complexes on different levels in both physiological and pathological conditions. In this review, we discuss the main light and electron microscopy techniques used to unravel the structure and composition of the three cell-cell contacts in epithelial and endothelial cells. It functions as a guide to pick the appropriate imaging technique(s) for the adhesion complexes of interest. We also point out the latest techniques that have emerged. At the end, we discuss the problems investigators encounter during their cell-cell adhesion research using microscopic techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrasonic imaging in liquid sodium

The fourth generation of nuclear reactor can use liquid sodium as the core coolant. When the reactor is operating, sodium temperatures can reach up to 600 deg. C. During maintenance periods, when the reactor is shut down, the coolant temperature is reduced to 200 deg. C. Because molten sodium is optically opaque, ultrasonic imaging techniques are developed for maintenance activities. Under-sodium imaging aims at i) checking the health of immersed structures. It should also allow ii) to assess component degradation or damage as cracks and shape defects as well as iii) the detection of lost objects. The under-sodium imaging system has to sustain high temperature (up to 300 deg. C) and hostility of the sodium environment. Furthermore, specific constraints such as transducers characteristics or the limited sensor mobility in the reactor vessel have to be considered. This work focuses on developing a methodology for detecting damages such as crack defects with ultrasound devices. Surface-breaking cracks or deep cracks are sought in the weld area, as welds are more subject to defects. Traditional methods enabled us to detect emerging cracks of submillimeter size with sodium-compatible high-temperature transducer. The presented approach relies on making use of prior knowledge about the environment through the implementation of differential imaging and time-reversal techniques. Indeed, this approach allows to detect a change by comparison with a reference measurement and by focusing back to any change in the environment. It is a means of analysis and understanding of the physical phenomena making it possible to design more effective inspection strategies. Difference between the measured signals reveals the acoustic field scattered by a perturbation (a crack for instance), which may occur between periodical measurements. The imaging method relies on the adequate combination of two computed ultrasonic fields, one forward and one adjoint. The adjoint field, which carries the information about the defects, is analogous to a time-reversal operation. One of the interests of the presented method is that the time-reversal operation is not done experimentally but numerically. Numerical simulations have been carried out to validate the practical relevance of this approach. The preliminary numerical results show a nice agreement between the guessed and the actual positions of the defect. After water-tests, in sodium-tests must be done in order to validate the water/sodium transposition. For this purpose, an under-sodium device is under development, which can move the transducers with four degrees of freedom in a 1.5 m{sup 3} sodium pot. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EUV photolithography mask inspection using Fourier ptychography

Fourier ptychography is a computational imaging techniques that combines various full-field coherent images acquired under varied illumination angles and combined to yield a angular spectrum with a large synthetic numerical aperture and non-interferometric phase information. We present here the implementation of this technique in a full-field soft x-ray microscope designed to emulate modern EUV lithography tools imaging conditions, and we show that this technique can be used for the study of EUV photomasks. The technique allows us to quantitatively characterize phase defects (predominant in EUV lithography), to study new mask designs made of phase structures, to study sub-resolution assist features and extend the resolution of the microscope down to 26-nm, correspond to the N1 technology node.

Wojdyla, Antoine↗

Complex Spiral Structure in the HD 100546 Transitional Disk as Revealed by GPI and MagAO

We present optical and near-infrared high-contrast images of the transitional disk HD 100546 taken with the Magellan Adaptive Optics system (MagAO) and the Gemini Planet Imager (GPI). GPI data include both polarized intensity and total intensity imagery, and MagAO data are taken in Simultaneous Differential Imaging mode at H α . The new GPI H -band total intensity data represent a significant enhancement in sensitivity and field rotation compared to previous data sets and enable a detailed exploration of substructure in the disk. The data are processed with a variety of differential imaging techniques (polarized, angular, reference, and simultaneous differential imaging) in an attempt to identify the disk structures that are most consistent across wavelengths, processing techniques, and algorithmic parameters. The inner disk cavity at 15 au is clearly resolved in multiple data sets, as are a variety of spiral features. While the cavity and spiral structures are identified at levels significantly distinct from the neighboring regions of the disk under several algorithms and with a range of algorithmic parameters, emission at the location of HD 100546 “ c ” varies from point-like under aggressive algorithmic parameters to a smooth continuous structure with conservative parameters, and is consistent with disk emission. Features identified in the HD 100546 disk bear qualitative similarity to computational models of a moderately inclined two-armed spiral disk, where projection effects and wrapping of the spiral arms around the star result in a number of truncated spiral features in forward-modeled images.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing RHESSI X-ray Imaging

RHESSI X-ray imaging is possible with angular resolution as fine as 2 arcsec (FWHM) at energies from as low as 3 keV to >100 keV. However, taking full advantage of this capability has proven to be challenging given the Fourier-transform imaging technique that is used, specific instrumental considerations that must be taken into account, and the many different options of the available image reconstruction algorithms. Such considerations as the best reconstruction algorithm to use, the optimal weighting of the different Fourier components, deciding between short image integration times and rapid imaging cadence, the different energy ranges covered by the 9 detectors, the effect of pulse pile-up and albedo, etc. must all be taken into account in obtaining and interpreting RHESSI X-ray images. This poster describes different techniques for optimizing the image reconstruction depending on the science objectives - identifying compact or extended sources, searching for source motion, obtaining the best photometry, determining the believability of different features in an image, etc. The emphasis is on making full use of data from all the RHESSI detectors, including the ones behind the finest grids when warranted by the source structure. This is the case for the hard X-ray emission along the ribbons of the flare on 2005 May 13 reported by Liu et al. (2007) and this event will be used as an example.

Dennis, Brian R.↗

SU-D-201-03: Imaging Cellular Pharmacokinetics of 18F-FDG in Inflammatory/Stem Cells

Purpose: Atherosclerosis is a progressive inflammatory condition that underlies coronary artery disease (CAD)—the leading cause of death in the USA. Thus, understating the metabolism of inflammatory cells can be a valuable tool for investigating CAD. To the best of our knowledge, we are the first to successfully investigate the pharmacokinetics of [18F]fluoro-deoxyglucose (18F-FDG) uptake in a single macrophages and compared with induced pluripotent stem cells (iPSCs) and mesenchymal stem cells (MSCs) with a novel imaging technique, radioluminescence microscopy, initially developed for cancer imaging. Methods: Live cells were cultured sparsely on Matrigel in a glass-bottom dish and starved for 1 hour before incubation with 250 microCi of 18F-FDG for 45 minutes. Excess radiotracer was removed using DMEM medium without glucose. Before imaging, DMEM (1 mL) was added to the cell culture and a 100 microm-thin CdWO4 scintillator plate was placed on top of the cells. Light produced following beta decay was imaged with a highly sensitive inverted microscope (LV200, Olympus) fitted with a 40x/1.3 high-NA oil objective, and an EM-CCD camera. The images were collected over 18,000 frames with 4×4 binning (1200 MHz EM Gain, 300ms exposure). Custom-written software was developed in MATLAB for image processing (Figure 1). For statistical analysis 10 different region-of-interests (ROIs) were selected for each cell type. Results: Figures 2A–2B show bright-field/fusion images for all three different cell types. The relationship between cell-to-cell comparisons was found to be linear for macrophages unlike iPSCs and MSCs, which were best fitted with moving or rolling average (Figure 2C). The average observed decay of 18F-FDG in a single cell of MSCs per second (0.067) was 20% and 36% higher compared to iPSCs (0.054) and macrophages (0.043), respectively (Figure 2D). Conclusion: MSCs was found to be 2–3x more sensitive to glucose molecule despite constant parameters for each cell type examined.

60 APPLIED LIFE SCIENCES↗

Computerized image processing at JPL.

Digital imaging techniques used in sinusoidal frequency response modification with or without computer control and display on operator console

IMAGING TECHNIQUE↗

Technology for Elevated Temperature Tests of Structural Panels

A technique for full-field measurement of surface temperature and in-plane strain using a single grid imaging technique was demonstrated on a sample subjected to thermally-induced strain. The technique is based on digital imaging of a sample marked by an alternating line array of La2O2S:Eu(+3) thermographic phosphor and chromium illuminated by a UV lamp. Digital images of this array in unstrained and strained states were processed using a modified spin filter. Normal strain distribution was determined by combining unstrained and strained grid images using a single grid digital moire technique. Temperature distribution was determined by ratioing images of phosphor intensity at two wavelengths. Combined strain and temperature measurements demonstrated on the thermally heated sample were DELTA-epsilon = +/- 250 microepsilon and DELTA-T = +/- 5 K respectively with a spatial resolution of 0.8 mm.

Thornton, E. A.↗

A High Performance Image Data Compression Technique for Space Applications

A highly performing image data compression technique is currently being developed for space science applications under the requirement of high-speed and pushbroom scanning. The technique is also applicable to frame based imaging data. The algorithm combines a two-dimensional transform with a bitplane encoding; this results in an embedded bit string with exact desirable compression rate specified by the user. The compression scheme performs well on a suite of test images acquired from spacecraft instruments. It can also be applied to three-dimensional data cube resulting from hyper-spectral imaging instrument. Flight qualifiable hardware implementations are in development. The implementation is being designed to compress data in excess of 20 Msampledsec and support quantization from 2 to 16 bits. This paper presents the algorithm, its applications and status of development.

Yeh, Pen-Shu↗

Bridging Nano- and Microscale X-Ray Tomography for Battery Research by Leveraging Artificial Intelligence

X-ray computed tomography (CT) is a non-destructive imaging technique in which contrast originates from the materials' absorption coefficient. The recent development of laboratory nanoscale CT (nano-CT) systems has pushed the spatial resolution for battery material imaging to voxel sizes of 50 nm, a limit previously achievable only with synchrotron facilities. Given the non-destructive nature of CT, in situ and operando studies have emerged as powerful methods to quantify morphological parameters, such as tortuosity factor, porosity, surface area and volume expansion, during battery operation or cycling. Combined with artificial intelligence and machine learning analysis techniques, nano-CT has enabled the development of predictive models to analyse the impact of the electrode microstructure on cell performances or the influence of material heterogeneities on electrochemical responses. In this Review, we discuss the role of X-ray CT and nano-CT experimentation in the battery field, discuss the incorporation of artificial intelligence and machine learning analyses and provide a perspective on how the combination of multiscale CT imaging techniques can expand the development of predictive multiscale battery behavioural models.

diagnostics↗

A digital scene matching technique for geometric image correction and autonomous navigation

A technique is described for precise registration of two images of the same area, taken under different conditions. The technique, called AUTO-MATCH, involves digital preprocessing of the images to extract edge contours, followed by a correlation of corresponding edge end points. The availability of an array of endpoints makes possible subpixed registration accuracy. The technique is applied to a system for assessment of geometric image quality, to be installed at NASA-Goddard. This system measures the registration vectors over an array of window pairs from LANDSAT images, so as to determine the distortion between them. Similar measurements could be used to infer relative positioning of the spacecraft. The technique is considered for updating the inertial navigation systems of missiles or aircraft. Scene matching between an image obtained aboard the vehicle and a stored reference can eliminate the drift of an inertial platform in order to demonstrate this capability in real time. A laboratory demonstration of AUTO-MATCH is described.

Tisdale, G. E.↗

A Two-Tier Convolutional Neural Network for Combined Detection and Segmentation in Biological Imagery

Deep learning techniques have been useful for modern microscopy imaging techniques to further study and analyze biological structures and organs. Convolutional neural networks (CNN) have improved 2D object detection, localization, and segmentation. For imagery containing biological structures with depth, it is especially desirable to perform these tasks in 3D. Traditionally, performing these tasks simultaneously in 3D has proven to be computationally expensive. Currently available methodologies thus largely work to segment 3D objects from 2D images (without context from captured 3D volumes). In this work, we present a novel approach to perform fast and accurate localization, detection, and segmentation of volumes containing cells. Specifically, in our method, we modify and tune two state-of-the-art CNNs, namely 2D YOLOv2 and 3D U-Net, and combine them with a new fusion and image processing algorithms. Annotated volumes in this space are limited, and we have created synthetic data that mimics actual structures for training and testing our proposed approach. Promising results on this test data demonstrate the value of the technique and offers a methodology for 3D cell analysis in real microscopy imagery.

Ziabari, Amir↗

Characterization of Apollo Regolith by X-Ray and Electron Microbeam Techniques: An Analog for Future Sample Return Missions

The Apollo missions collected 382 kg of rock and regolith from the Moon; approximately 1/3 of the sample mass collected was regolith. Lunar regolith consists of well mixed rocks, minerals, and glasses less than 1-centimeter n size. The majority of most surface regolith samples were sieved into less than 1, 1-2, 2-4, and 4-10- millimiter size fractions; a portion of most samples was re-served unsieved. The initial characterization and classification of most Apollo regolith particles was done primarily by binocular microscopy. Optical classification of regolith is difficult because (1) the finest fraction of the regolith coats and obscures the textures of the larger particles, and (b) not all lithologies or minerals are uniquely identifiable optically. In recent years, we have begun to use more modern x-ray beam techniques [1-3], coupled with high resolution 3D optical imaging techniques [4] to characterize Apollo and meteorite samples as part of the curation process. These techniques, particularly in concert with SEM imaging of less than 1-millimeter regolith grain mounts, allow for the rapid characterization of the components within a regolith.

Zeigler, Ryan A.↗

A Novel 24 GHz One-Shot, Rapid and Portable Microwave Imaging System

Development of microwave and millimeter wave imaging systems has received significant attention in the past decade. Signals at these frequencies penetrate inside of dielectric materials and have relatively small wavelengths. Thus. imaging systems at these frequencies can produce images of the dielectric and geometrical distributions of objects. Although there are many different approaches for imaging at these frequencies. they each have their respective advantageous and limiting features (hardware. reconstruction algorithms). One method involves electronically scanning a given spatial domain while recording the coherent scattered field distribution from an object. Consequently. different reconstruction or imaging techniques may be used to produce an image (dielectric distribution and geometrical features) of the object. The ability to perform this accurate~v and fast can lead to the development of a rapid imaging system that can be used in the same manner as a video camera. This paper describes the design of such a system. operating at 2-1 GHz. using modulated scatterer technique applied to 30 resonant slots in a prescribed measurement domain.

Ghasr, M. T.↗

STEM Characterization of Dislocation Loops in Irradiated FCC Alloys

In this study, we demonstrate the methodology systematically developed for dislocation loop (perfect and faulted loops) imaging and analysis in irradiated face-centered-cubic (FCC) alloys using scanning transmission electron microscopy (STEM). On-zone [001] STEM imaging was identified as the preferred choice for its accuracy and effectiveness based on the comparison with other dislocation loop imaging techniques including: (i) on-zone STEM imaging using other major low-index zone axes, (ii) kinematic two-beam conditions bright field imaging near the [001] zone axis in conventional TEM (CTEM) mode, and (iii) Rel-Rod CTEM dark-field (DF) imaging near the [011] zone axis. The effect of STEM collection angle on the contrast formation of dislocation loops was also investigated. The developed method was confirmed by imaging all populations of perfect and faulted loops of types a/2$\langle$110$\rangle${110} and a/3$\langle$111$\rangle${111} found in an ion irradiated Ni40Fe40Cr20 alloy. The proposed STEM-based technique can easily identify said loops with a size greater than 10 nm without any assumptions such as those commonly made using the conventional Rel-Rod CTEM-DF technique. The recommended methodology in this study is developed as a quick and convenient tool that can be generally applied to irradiated FCC-based materials due to their common crystallography.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗