Improving accuracy of electron density measurement in the presence of metallic implants using orthovoltage computed tomography

The goal of this study was to evaluate the improvement in electron density measurement and metal artifact reduction using orthovoltage computed tomography (OVCT) imaging compared with conventional kilovoltage CT (KVCT). For this study, a bench-top system was constructed with adjustable x-ray tube voltage up to 320 kVp. A commercial tissue-characterization phantom loaded with inserts of various human tissue substitutes was imaged using 125 kVp (KVCT) and 320 kVp (OVCT) x rays. Stoichiometric calibration was performed for both KVCT and OVCT imaging using the Schneider method. The metal inserts--titanium rods and aluminum rods--were used to study the impact of metal artifacts on the electron-density measurements both inside and outside the metal inserts. It was found that the relationships between Hounsfield units and relative electron densities (to water) were more predictable for OVCT than KVCT. Unlike KVCT, the stoichiometric calibration for OVCT was insensitive to the use of tissue substitutes for direct electron density calibration. OVCT was found to significantly reduce metal streak artifacts. Errors in electron-density measurements within uniform tissue substitutes were reduced from 42% (maximum) and 18% (root-mean-square) in KVCT to 12% and 2% in OVCT, respectively. Improvements were also observed inside the metal implants. For the detectors optimized for KVCT, the imaging dose is almost doubled for OVCT for the image quality comparable to KVCT. OVCT may be a good option for high-precision radiotherapy treatment planning, especially for patients with metal implants and especially for charged particle therapy, such as proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A New Flow-Through Balance for Retropropulsion Testing

Supersonic retropropulsion is believed to be an enabling technology for large-scale human Mars lander vehicle concepts. Ground testing of such vehicles requires the development of new flow-through wind tunnel balances because no suitable balances exist. A new flow-through balance is designed that employs membranes in place of bellows, which have historically been used, and that passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure supersonic retropropulsion performance of powered descent vehicles.

Flow through balance↗

Simultaneous inner-and outer-sphere arsenate adsorption on corundum and hematite.

The ability to predict the fate and transport of arsenic in aquatic environments, its impact on water quality and human health, and the performance and cost-effectiveness of water treatment systems relies on understanding how it interacts with solid surfaces. In situ resonant surface X-ray scattering measurements of arsenate adsorption at pH 5 in 0.01 M NaCl on corundum and hematite (012) surfaces demonstrate that arsenate surface complexation is unexpectedly bimodal, adsorbing simultaneously as inner- and outer-sphere species. In addition, this bimodal behavior is found to be independent of the total arsenate solution concentration, and thus surface coverage, over the range of 10{sup -6} to 10{sup -3} M. Alternative mechanisms to produce the observed As distributions, such as arsenate dimerization or surface precipitation of an aluminum or ferric arsenate, are inconsistent with the experimentally-determined total and As-specific density profiles. Based on the location of the outer-sphere arsenate in relation to the surfaces studied, possible binding mechanisms include electrostatic attraction, hydrogen bonding to surface oxygen functional group, and configurational stabilization by interfacial water. Although the observation of outer-sphere arsenate surface complexes on a metal oxide surface is unprecedented, it is unclear if such species were absent in previous molecular-scale studies, as it is difficult for methods commonly used to investigate the mechanisms of arsenate adsorption to conclusively identify or rule out the presence of outer-sphere species when inner-sphere species are also present.

08 HYDROGEN↗

Innovative Patient Room Lighting System with Integrated Spectrally Adaptive Control

In December of 2013, the U.S. Department of Energy’s SSL R&D Program released a Funding Opportunity Announcement (FOA), that for the first time, contained opportunities for comprehensive application-specific system development. The FOA included opportunities for two applications, one of which was a Patient Room. Philips Lighting Research North America, submitted a proposal for the Patient Room application, and was selected for the complete project award. The award amount was for $497,127, with a Philips Research co-funding commitment 165,709 dollars. The total project value was 662,836 dollars. This project sought to redefine lighting for the patient room application. The goal was to deliver an innovative LED patient suite (patient room and bathroom) lighting system solution that was 40% more energy-efficient than traditional fluorescent incumbent technologies, and would meet all the visual and non-visual needs of patients, caregivers and visitors, and improve the patient experience. State-of-the-art multichannel LED platforms and control technologies that would provide spectral tuning and become part of an intelligent, connected lighting system drove the solution. The project was scoped into four main task areas that included a) System Concept Creation, b) Identification of the Luminaire Portfolio, c) Development of the Connected Lighting Infrastructure, and d) System Performance Validation. Each of the four main tasks were completed and validated extensively over the course the 2 ½ year project. The system concept was created by first developing a lighting design that demonstrated best practices for patient room lighting – illuminance and uniformity for task performance, reduced glare, and convenient controls, in addition to giving patients control over the lighting in their environment. A framework was defined to deliver circadian support via software behaviors. Through that process luminaires were identified from the Philips portfolio that were adaptable – by their form, dimensions, and optical materials – to mix multicolor LED platforms uniformly and deliver target design lumen levels. The Blue Sky luminaire was selected for the patient bed area to give the illusion of skylight while providing white light on the patient bed. Luminaires used existing 2-channel tunable white LED boards, and newly developed 4-channel LED boards. Red-Orange, Blue, Green, and Blue-shifted Yellow LED chips were selected based on spectral characteristics and their ability to produce high quality white light. 4-channel Power over Ethernet (PoE) drivers were developed and firmware written so they would communicate with both 2- and 4-channel boards. These components formed the backbone of the connected lighting infrastructure. Software, flexible and nuanced in its complexity, was written to set behaviors for myriad lighting scenes in the room throughout the 24 hour day – and all could be overridden by manual controls. This included a dynamic tunable white program, three color changing automatic programs that simulated degrees of sunrise to sunset palettes, and an amber night lighting system that offered visual cues for postural stability to minimize the risk of falls. All programs were carefully designed to provide visual comfort for all occupants, support critical task performance for staff, and to support the patient’s 24hr rhythms. A full scale mockup room was constructed in the Philips Cambridge Lab. The lighting system was installed, tested and functionality demonstrated to ensure smooth operation of system components – luminaires, drivers, PoE switches, wall controls, patient remote, and daylight and occupancy sensors. How did the system perform? It met visual criteria, confirmed by calculations, simulations and measurements in the field. It met non-visual criteria, confirmed by setting circadian stimulus (CS) targets and performing calculations using the calculator developed by the Lighting Research Center. Finally, human factors validation studies were conducted to gain insight from real end users in the healthcare profession; surveys were administered, data analyzed, and audio comments captured. The general consensus was positive, with requests to pilot the system in their hospitals. The importance of the research completed under this grant is that it allowed the exploration and development of a unique lighting system, one that would deliver a blend of visual and non-visual criteria in patient room design for today’s healthcare environment. The research investigated the area of multichannel LED technology, multichannel Power over Ethernet (PoE) drivers and their integration with automatic and manual controls as a system – uncovering and meeting challenges along the way. It married visual needs of patients and staff with support for 24 hour rhythms, placing value on the wellbeing of the patient – while successfully saving energy over incumbent technologies. Indications are that the market is ready and willing to invest – multiple healthcare facilities are in line to pilot this system, recognizing its value beyond energy to patient and staff well-being. Its value to the public can best be expressed by a patient support coordinator who, after spending several hours in the room being immersed in the lighting, analyzing all its features, commented: “This re-writes lighting for healthcare”.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Influence of visual and motion cues on manual lateral stabilization

The ability of humans to detect and control their own lateral acceleration was measured by means of a closed-loop nulling task. Wide-field moving visual cues enhanced the operator's performance in nulling self-motion, especially at lower frequencies. Even visual cues, fixed relative to the operator, resulted in performance improvement relative to self-motion nulling in the dark. Describing function (frequency response) data was obtained for random acceleration conditions consisting of the visual field fixed relative to the laboratory, fixed relative to the subject, moving at constant velocity relative to the subject, and in the dark. The describing function data was corrected for the dynamics of operator manual control strategy. The resulting frequency responses were used to develop a linear model of self-motion detection which required a lead term of 1.5 rad/s to be added to the existing model in order to match the higher sensitivity at higher frequencies.

Huang, J.-K.↗

Blood biochemical and cellular changes during decompression and simulated extravehicular activity

Blood biochemical and cellular parameters were measured in human subjects before and after exposure to a decompression schedule involving 6 h of oxygen prebreathing. The exposure was designed to simulate extravehicular activity for 6 h (subjects performed exercise while exposed to 29.6 kPa). There were no significant differences between blood samples from subjects who were susceptible (n = 11) versus those who were resistant (n = 27) to formation of venous gas emboli. Although several statistically significant (P less than 0.05) changes in blood parameters were observed following the exposure (increases in white blood cell count, prothrombin time, and total bilirubin, and decreases in triglycerides, very-low-density lipoprotein cholesterol, and blood urea nitrogen), the changes were small in magnitude and blood factor levels remained within normal clinical ranges. Thus, the decompression schedule used in this study is not likely to result in blood changes that would pose a threat to astronauts during extravehicular activity.

Decompression Sickness/blood/etiology/prevention &↗

Summary of Martian Dust Filtering Challenges and Current Filter Development

Traditional air particulate filtering in manned spaceflight (Apollo, Shuttle, ISS, etc.) has used cleanable or replaceable catch filters such as screens and High-Efficiency Particulate Arrestance (HEPA) filters. However, the human mission to Mars architecture will require a new approach. It is Martian dust that is the particulate of concern but the need also applies to particulates generated by crew. The Mars Exploration Program Analysis Group (MEPAG) high-lighted this concern in its Mars Science, Goals, Objectives, Investigations and Priorities document [7], by saying specifically that one high priority investigation will be to "Test ISRU atmospheric processing systems to measure resilience with respect to dust and other environmental challenge performance parameters that are critical to the design of a full-scale system." By stating this as high priority the MEPAG is acknowledging that developing and adequately verifying this capability is critical to success of a human mission to Mars. This architecture will require filtering capabilities that are highly reliable, will not restrict the flow path with clogging, and require little to no maintenance. This paper will summarize why this is the case, the general requirements for developing the technology, and the status of the progress made in this area.

O'Hara, William J., IV↗

Implementation of Software Tools for Hybrid Control Rooms in the Human Systems Simulation Laboratory

The Institute for Energy Technology (IFE) and Idaho National Laboratory have designed, implemented, tested and installed a functioning prototype of a set of large screen overview and procedure support displays for the Generic Pressurized Water Reactor (GPWR) simulator in the U.S. Department of Energy’s Human Systems Simulation Laboratory. The overview display is based on IFE’s extensive experiences with large screen overview displays in the Halden Man-Machine Laboratory (HAMMLAB), and presents the main control room indicators on a combined three-screen display. The procedure support displays are designed and implemented to provide a compact but still comprehensive overview of the relevant process measurements and indicators to support operators' good situational awareness during the performance of various types of procedures and plant conditions.

97 MATHEMATICS AND COMPUTING↗

Scientific/Technical Report Bioenergetics Research Initiative Award number-DE-FG02-05ER64092

General Project Overview and Final Technical Report This equipment grant was utilized to enhance the infrastructure of the Human Performance Laboratory at Ball State University. The laboratories primary focus is human based exercise physiology conducting research in the areas of sports performance, aging and exercise, unloading (space flight and bed rest), pediatric exercise and clinical exercise physiology. The main equipment supported by this grant was an ultrasound unit for cardiac and skeletal muscle imaging at the whole organ level, microscope system for micro imaging of skeletal muscle tissue, running treadmill for energy expenditure assessment, autoclave for sterilization, and upgrade to our dual x–ray absorptiometry (DEXA) system that was utilized for body composition measurements. The equipment was involved in several human metabolic and skeletal muscle research projects as highlighted above. In particular, this equipment served a support role for other large–scale clinical projects funded by the National Institutes of Health (NIH), National Aeronautics and Space Administration (NASA), and corporate sponsors.

59 BASIC BIOLOGICAL SCIENCES↗

Short Period Fluctuations in Intelligence Final Report

The problem of isolating fluctuations in intellectual function is one that has long intrigued both psychologists and non-psychologists, We are all aware of our own short-period physiological, mood and motivational changes and many believe that their intelligence must undergo similar change. 1965 for a recent review) does not provide support for this kind of argu- ment. It indicates that measures of intelligence - -at least those intended for use with people other than infants --are usually highly stable over both short and rather extended periods of time: the changes which are indicated have almost always been regarded as errors of measurement. Thus in scientific developments (as opposed, perhaps, to common- sense discussions) ;intelligence usually has been regarded as a highly stable attribute of man. But existing scientific evidence (see Tyler, A notable exception to the scientific theory arguing (albeit im- plicitly) that human intellect does not fluctuate over short period of time is that of Moran (1961) and his co-workers (Moran, Kimble & Mefferd, 1960; 1964; Moran & Mefferd, 1959). The work of these in- vestigators has been directed at designing alternate -form tests to measure some of what are now regarded as the major, replicated-by- research dimensions of human intelligence, viz., what are known as the primary mental abilities (French, 1951: French, Ekstrom & Price, 1963; Guilford, 1966; Guilford & Merrifield, 1960). The Repetitive Psychological Measures (RPM) resulting from this work are intended to assess "change in performance with time" (Moran & Mefferd, 1959: p. 269). little has been done to determine whether or not the performances actually assessed do, in fact, change in a reliable manner. Indeed, evidence somewhat contrary to an hypothesis of short-period change is provided by the high (relative to test length) test-retest correlations ob- tained over a period of 3 hours with the RPM tests (Moran & Mefferd, 1959; Table 2). Hence, while a basic hypothesis underlying this work certainly does imply that abilities change over short periods, evidence for this hypothesis either has not been developed or, where it has (as in test-retest correlations), does not provide convincing support for the hypothesis

Intelligence↗

Skin remittance kinetics in the spectral range of 550 – 790 nm

An experimental method for remitted photon time-of-flight (PTOF) estimation in human skin in vivo is developed and tested. Remitted light signals are obtained using a picosecond broadband laser and a set of narrowband interference filters centred at 550, 600, 650, 700, 750 and 790 nm. Four different distances of 8, 12, 16 and 20 mm between the source and detector fibres are used. Measurements are performed at different wavelengths and distance combinations. Direct kinetic measurements make it possible to assess the mean photon path length in skin at various spectral regions. Results generally correspond to theoretical expectations; however, no clear dependence on wavelengths in the spectral range 650–790 nm is observed. This study shows a promising opportunity to use this kind of measurement system in the future research of PTOF in human skin. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

H{sup +}/peptide transporter (PEPT2) is expressed in human epidermal keratinocytes and is involved in skin oligopeptide transport

Peptide transporter 2 (PEPT2) is a member of the proton-coupled oligopeptide transporter family, which mediates the cellular uptake of oligopeptides and peptide-like drugs. Although PEPT2 is expressed in many tissues, its expression in epidermal keratinocytes remains unclear. We investigated PEPT2 expression profile and functional activity in keratinocytes. We confirmed PEPT2 mRNA expression in three keratinocyte lines (normal human epidermal keratinocytes (NHEKs), immortalized keratinocytes, and malignant keratinocytes) by reverse transcription-polymerase chain reaction (RT-PCR) and quantitative real-time RT-PCR. In contrast to PEPT1, PEPT2 expression in the three keratinocytes was similar or higher than that in HepG2 cells, used as PEPT2-positive cells. Immunolocalization analysis using human skin showed epidermal PEPT2 localization. We studied keratinocyte transport function by measuring the oligopeptide content using liquid chromatography/tandem mass spectrometry. Glycylsarcosine uptake in NHEKs was pH-dependent, suggesting that keratinocytes could absorb small peptides in the presence of an inward H{sup +} gradient. We also performed a skin-permeability test of several oligopeptides using skin substitute, suggesting that di- and tripeptides pass actively through the epidermis. In conclusion, PEPT2 is expressed in keratinocytes and involved in skin oligopeptide uptake. -- Highlights: •PEPT2 is expressed in keratinocytes, which are more common than other skin cells. •Immunolocalization analysis using human skin revealed epidermal PEPT2 localization. •Keratinocytes could absorb small peptides in the presence of an inward H{sup +} gradient. •Di- and tripeptide pass actively through the epidermis.

60 APPLIED LIFE SCIENCES↗

On the quantitative evaluation of edge detection schemes and their comparison with human performance

A technique for the quantitative evaluation of edge detection schemes is presented. It is used to assess the performance of three such schemes using a specially-generated set of images containing noise. The ability of human subjects to distinguish the edges in the presence of noise is also measured and compared with that of the edge detection schemes. The edge detection schemes are used on a high-resolution satellite photograph with varying degrees of noise added in order to relate the quantitative comparison to real-life imagery.

Fram, J. R.↗

Impacts of environmental exposure on thermal and mycological characteristics of insulation wools

Highlights: • Insulation materials (IM) suffer expositions to weather on energy efficient buildings. • Induced exposure to weather of IM reveals differences in ATR-FTIR spectra. • Mycological analysis shows a significant effect of exposure condition on IM. • Mold species detected may induce human health risk and degradation of IM. • Thermal conductivity of IM according humidity of air may impact energy performance. - Abstract: Fieldwork was conducted on 138 energy efficient buildings, to check if building site practices induced exposure to weather of thermal insulation. In nearly 80% of cases, insulation was exposed to weather due to insufficient protection. Therefore insulating wools were exposed, divided into three parts (control, exposure under shelter, exposure to weather). After the exposure period these samples were submitted to thermal conductivity measurements and infrared spectroscopy. A numerical study was carried out to evaluate the influence of weather conditions on thermal performance. Identifications of molds were realized by direct cultures of each sample. Mycological analyses provided the most significant results, showing a significant effect of exposure condition, with possible consequences in human health (toxinogenic, allergenic or pathogenic species) and material properties (cellulolytic species). Infrared spectrometry also showed some changes in sensitivity to water. These results show the interest to study in more detail the variations in the sensitivity, to moisture and mold, of insulation material throughout its ageing on site, and the interactions with the practices of the building process.

36 MATERIALS SCIENCE↗

Enhancing Complex System Performance Using Discrete-Event Simulation

In this paper, we utilize discrete-event simulation (DES) merged with human factors analysis to provide the venue within which the separation and deconfliction of the system/human operating principles can occur. A concrete example is presented to illustrate the performance enhancement gains for an aviation cargo flow and security inspection system achieved through the development and use of a process DES. The overall performance of the system is computed, analyzed, and optimized for the different system dynamics. Various performance measures are considered such as system capacity, residual capacity, and total number of pallets waiting for inspection in the queue. These metrics are performance indicators of the system's ability to service current needs and respond to additional requests. We studied and analyzed different scenarios by changing various model parameters such as the number of pieces per pallet ratio, number of inspectors and cargo handling personnel, number of forklifts, number and types of detection systems, inspection modality distribution, alarm rate, and cargo closeout time. The increased physical understanding resulting from execution of the queuing model utilizing these vetted performance measures identified effective ways to meet inspection requirements while maintaining or reducing overall operational cost and eliminating any shipping delays associated with any proposed changes in inspection requirements. With this understanding effective operational strategies can be developed to optimally use personnel while still maintaining plant efficiency, reducing process interruptions, and holding or reducing costs.

42 ENGINEERING↗

Human Factors Evaluation of Energy Visualization Dashboards

Energy visualization systems provide information about use in real-time to assist users with energy efficiency. In this study, three energy visualization dashboards for small businesses were developed and tested. Performance measurement, NASA Task Load Index (TLX) workload assessment, and posttest survey were used to conduct the usability testing. Compared with the dashboards that were designed using line charts and tables, a dashboard designed using visuals (e.g., gauges, pie charts, and flashing lights) produced quicker response time, lower mental and temporal demand and effort ratings, and higher ratings of engagement, interest, and trustworthiness.

Nimbarte, Ashish D. (ORCID:0000000210599112)↗

Effects of Eye Measures on Human Controller Remnant and Control Behavior

The aim of the current research was to investigate the possible relation between changes in eye activity parameters, variations in human remnant at the perceptual level and changes in human operator model parameters. Fourteen subjects performed a pitch tracking task, in which the display brightness was varied by changing the background color around a simplified primary flight display, in order to create a controlled, quasilinear change in the pupil diameter through the pupillary light reflex. Pupil diameter, blink, eye opening, and opening and closing amplitudes and speeds were recorded using an eye tracker. Participants controlled single integrator-like and double integrator-like dynamics. The variation in pupil diameter did not introduce significant differences in neither remnant characteristics nor the human operator model parameters. An interesting effect occurred in the human controller’s time delay for the single integrator task, where the time delay was significantly higher for the darkest brightness compared to the other levels of brightness. This effect was not observed for the double integrator dynamics. Data suggested that the more difficult controlled dynamics induced a squinting effect, visible in smaller eye opening, and smaller eye opening and closing amplitudes. These results suggest that performance, and control behavior are invariant to the display brightness. Moreover, monitoring changes in the eye activity could represent a method of predicting variations in human remnant characteristics and human controller model parameters, introduced by task difficulty.