Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “homes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Affordable Solid Panel "Perfect Wall" System

The SPS is an innovative interpretation of the “perfect wall” concept, in which environmental control layers are located on the exterior side of the structural components, as opposed to traditional cavity insulated, stud-framed walls. The primary objective of this study is to validate the SPS technology in terms of its constructability, cost, and performance. Specifically for this project, we partnered with two affordable housing nonprofits in Minnesota—Twin Cities Habitat for Humanity and Urban Homeworks—to build five new houses using SPS walls, as well as two high-performance stud-framed comparison homes. We also reviewed cost and performance data from 13 SPS homes built prior to this project by MonoPath and Spero Environmental Builders. Reviewing the outcomes of these 20 homes total, we find promising results in terms of constructability, cost, and performance, although more structural performance data are needed before this new technology can see widespread adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the Power Outage Resilience of Buildings with Solar PV through the Use of Battery Systems and EV Energy Storage

Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.

14 SOLAR ENERGY↗

Scaling Up to Zero Energy Ready - and Down to 530 ft2

There is a demonstrated need for affordable housing and smaller homes. Reduced square footage new construction projects present a solution for this growing need. Completion of these types of projects is not without challenges however, as high efficiency building measures present problems with proper equipment sizing and indoor environmental quality. This case study describes the support provided by FSEC to the Manatee County Habitat for Humanity to create a small footprint home design that qualifies for Zero Energy Ready Home (ZERH) certification in Florida. Specific measures to address equipment sizing challenges, and interior air quality targets are identified among other construction elements that contribute to qualifying for ZERH certification. Discussion of the approach to meeting these challenges is informative to other efforts to build to above code standards in hot humid climates, and other regions.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Design and analysis of optimal pre-cooling in residential buildings

Existing pre-cooling strategies provide a means of shifting or reducing the peak demand and/or energy cost in residential buildings. However, majority of them are rule-based and therefore may not be optimal in terms of cost saving, leaving room for improvement. In this paper, an integer linear programming problem that accounts for the thermal properties of a specific home, HVAC system capacity, utility rate structure, and weather conditions and makes use of a home thermal model is formulated. This problem determines the HVAC on/off control signal that minimizes the 24-h energy cost while maintaining thermal comfort and calculates the corresponding optimal indoor air temperature. The model is constructed using home thermal properties identified via data training in real-time. Through simulation, the energy performance of the proposed optimal pre-cooling strategy is investigated and compared with three rule-based operation strategies from the literature. It is found that the optimal strategy requires the least energy consumption without sacrificing thermal comfort. The superb energy performance of the optimal strategy is attributed to a longer runtime of the HVAC system in cool outdoor air conditions and to the elimination of deadband in HVAC operation, which is required by the rule-based strategies, to allow the indoor air temperature to stay near the thermal comfort upper bound as much as possible. In terms of energy cost, the rule-based operation strategies require 3.52, 1.90, and 2.79, respectively, while the optimal strategy only requires 1.52. These figures represent a saving of 56.82%, 20.00%, and 45.52%, respectively. The results suggest that the optimal strategy is indeed significantly more effective than the existing rule-based operation strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gas and Propane Combustion from Stoves Emits Benzene and Increases Indoor Air Pollution

Exposure pathways to the carcinogen benzene are well-established from tobacco smoke, oil and gas development, refining, gasoline pumping, and gasoline and diesel combustion. Combustion has also been linked to the formation of nitrogen dioxide, carbon monoxide, and formaldehyde indoors from gas stoves. To our knowledge, however, no research has quantified the formation of benzene indoors from gas combustion by stoves. Across 87 homes in California and Colorado, natural gas and propane combustion emitted detectable and repeatable levels of benzene that in some homes raised indoor benzene concentrations above well-established health benchmarks. Mean benzene emissions from gas and propane burners on high and ovens set to 350 °F ranged from 2.8 to 6.5 μg min –1 , 10 to 25 times higher than emissions from electric coil and radiant alternatives; neither induction stoves nor the food being cooked emitted detectable benzene. Benzene produced by gas and propane stoves also migrated throughout homes, in some cases elevating bedroom benzene concentrations above chronic health benchmarks for hours after the stove was turned off. Combustion of gas and propane from stoves may be a substantial benzene exposure pathway and can reduce indoor air quality.

54 ENVIRONMENTAL SCIENCES↗

Cross-sectoral synergies for household energy savings: the role of electric vehicles, solar photovoltaics, and remote work

Over the past two decades, new technologies and behavioral shifts – such as electric vehicles, solar photovoltaics, and increased work-from-home practices – have reshaped residential electricity consumption and cost. However, their combined or synergistic impact on a household’s electricity cost remains unexplored. Leveraging data from the 2020 Residential Energy Consumption Survey, this study uses a structural equation model to unravel the extent to which the bundled adoption of EV-PV and stay-at-home decisions impact the total electricity cost of households. Results indicate that adopting both EVs and PV reduces electricity costs by 31% despite a 16% rise in consumption. When combined with stay-at-home practices, households still experience a 13% cost reduction, even with a 25% increase in electricity consumption. In conclusion, these findings suggest that financial savings are not merely a byproduct of adopting new technologies or behavioral changes but could serve as a key consideration for household contemplating engagement with multiple modern energy solutions simultaneously.

14 SOLAR ENERGY↗

An Energy Codes Gap Analysis Field Study in the Southwest (Final Technical Report)

The primary goal of the “An Energy Codes Gap Analysis Field Study in the Southwest” project was to improve housing through strengthened building energy code implementation in two states, Colorado and Nevada, leading to greater energy and utility bill savings for households. Colorado is a home rule state. Nevada adopts a statewide code, but cities and counties must also adopt the code, making the state function like a home rule state. To broaden the impact of the project, an additional goal was to share and amplify project experiences, findings, and lessons that can be applied in other states. To achieve these goals, the project’s key objectives were to examine how residential energy codes are implemented in partner states; to use these findings to strengthen codes implementation through enhanced education, training, and outreach; and to enhance energy code technical assistance capabilities in the two partner states. In both partner states, the project led to the creation of a quantitative baseline understanding of compliance with high-impact energy code requirements, such as foundation, wall, and ceiling R-value; window U-factor and SHGC; envelope air tightness; duct tightness; and high-efficiency lighting. It then applied this baseline information to directly inform training in geographic areas with high levels of building and construction activity. The project has placed Colorado and Nevada among 23 states across the country that have conducted a single-family residential field study based on the established U.S. Department of Energy (DOE) methodology since 2014. It has also helped each State Energy Office test models for partnership- and relationship-building among government agencies and key stakeholder groups, including the State Energy Office and relevant code administration and professional licensing agencies, building officials, designers, builders, trades and utilities. At the national level, the project helped educate and inform State and Territory Energy Offices on a replicable methodology to assess energy code construction practices, effective stakeholder engagement strategies, and tailored energy code education and training. These findings are particularly pertinent for home-rule states, such as Colorado and Nevada, which rely on local government awareness and action to advance and implement building energy codes. By raising awareness of code adoption and compliance, this project has helped to equip each partner state with data on code compliance, strategies, education, and partnership models to advance building energy codes. This in turn will have an important impact on new construction practices in Colorado and Nevada, leading to more energy efficient and affordable housing. Currently, more than 62 percent of Colorado’s population lives in one of the 55 jurisdictions that have adopted the 2021 IECC to date, while nearly 95 percent of the state's population lives in one of the 208 jurisdictions that have adopted a code at 2015 IECC levels or higher. In Nevada, the 2018 IECC was adopted by the Governor’s Office of Energy in July 2018. By July 2020, 47 percent of the adopted energy code in the state was 2018 IECC which covers 96.5 percent of Nevada’s population. The training materials funded by this project focus on the 2021 IECC and will continue to be relevant in the two states as additional jurisdictions update their building energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Role of social structure in establishment of an invasive large mammal after translocation

Abstract Background Data on the movement behavior of translocated wild pigs is needed to develop appropriate response strategies for containing and eliminating new source populations following translocation events. We conducted experimental trials to compare the home range establishment and space‐use metrics, including the number of days and distance traveled before becoming range residents, for wild pigs translocated with their social group and individually. Results We found wild pigs translocated with their social group made less extensive movements away from the release location and established a stable home range ~5 days faster than those translocated individually. We also examined how habitat quality impacted the home range sizes of translocated wild pigs and found wild pigs maintained larger ranges in areas with higher proportion of low‐quality habitat. Conclusion Collectively, our findings suggest translocations of invasive wild pigs have a greater probability of establishing a viable population near the release site when habitat quality is high and when released with members of their social unit compared to individuals moved independent of their social group or to low‐quality habitat. However, all wild pigs translocated in our study made extensive movements from their release location, highlighting the potential for single translocation events of either individuals or groups to have far‐reaching consequences within a much broader landscape beyond the location where they are released. These results highlight the challenges associated with containing populations in areas where illegal introduction of wild pigs occurs, and the need for rapid response once releases are identified. © 2023 The Authors. Pest Management Science published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.

Clontz, Lindsay M.↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Effects of head-starting on multi-year space use and survival of an at-risk tortoise

A major challenge in the recovery of long-lived at-risk taxa like turtles is low juvenile recruitment. Head-starting—the raising of juveniles to larger sizes to improve survival—is one tool that can be used in circumstances where juvenile recruitment is limited. Due to declining populations and difficulty detecting juveniles, however, lack of knowledge of the ecology of juveniles can hinder efforts to develop and evaluate head-starting programs for many turtle species. We sought to inform recovery efforts of Mojave desert tortoises by quantifying multi-year space use and survival of head-started juveniles after release. We radio-tracked tortoises head-started under three different husbandry treatments that varied in rearing duration (from two to over six years) and whether head-starting included an indoor rearing component the first year. We compared postrelease space use and survival as a function of treatment, release size, and time since release. We found that space use, including home range size and site fidelity, varied by husbandry treatment, with smaller and younger tortoises having smaller home ranges and higher site fidelity. Additionally, home range size decreased and site fidelity increased with time since release across treatments. Tortoises with an indoor-rearing component experiencing increased risk of mortality as movement increased compared to tortoises reared solely outdoors. Nevertheless, survival did not differ among treatments or with tortoise age or size. Regardless of husbandry treatment, head-started tortoises exhibited similar space-use and survival overall. Our study provides insight into juvenile tortoise behavior and head-starting as a tool for tortoise conservation.

60 APPLIED LIFE SCIENCES↗

Hazard-Based Model of Activity Generation Using Vehicle Trajectory Data

Travel behavior modeling suffers from lack of longitudinal data due to the high cost of procurement and difficulty with ensuring data quality. In the recent years ubiquitous data intercepted from social media, cell detail record, GPS traces are increasingly being explored to analyze human mobility. However, these data lack key demographic information which limits their use for developing causal models of traveler behavior. The primary contribution of the paper lies in using vehicle trajectory data from Ann Arbor along with multiple other data sources for developing a hazard-based activity generation model. The different category of data used in the analysis include (i) vehicle trajectory data (VTD), (ii) American Census Survey (ACS), (iii) land use data, (iv) household travel survey (HTS) data, and (v) smart location data from Environmental Protection Agency (EPA). Home and work are identified as the two most frequently visited locations from the VTD and validated against land use categories of the region. Next a random utility-based model is developed using HTS data to identify other activity purposes as a function of the polynomials of distance from home, activity duration and departure time. The developed model is then applied to identify the non-home activity purposes in the VTD. Demographic and accessibility information are appended to the VTD from ACS and smart location databases respectively. The fmal database is then used to develop a hazard-based activity generation model. (C) 2020 The Authors. Published by Elsevier B.V.

activity generation↗

Modeling charging infrastructure impact on the electric vehicle market in China

The plug-in electric vehicle (PEV) is deemed as a critical technological revolution, and the governments are imposing various vehicle policies to promote its development. Meanwhile, the market success of PEVs depends on many aspects. The study reported herein integrates one’s use of charging infrastructure at home, public place and workplace into the market dynamics analysis tool, New Energy and Oil Consumption Credits (NEOCC) model, to systematically assess the charging infrastructure (home parking ratio, public charging opportunity, and charging costs) impact on PEV ownership costs and analyze how the PEV market shares may be affected by the attributes of the charging infrastructure. Compared to the charging infrastructure, the impact of battery costs is incontrovertibly decisive on PEV market shares, the charging infrastructure is still non-negligible in the PEV market dynamics. The simulation results find that the public charging infrastructure has more effectiveness on promoting the PEV sales in the PEV emerging market than it does in the PEV mature market. However, the improvement of charging infrastructure does not necessarily lead to a larger PEV market if the charging infrastructure incentives do not coordinate well with other PEV policies. Besides, the increase of public charging opportunities has limited motivations on the growth of public PEV fleets, which are highly correlated to the number of public fast charging stations or outlets. It also finds that more home parking spaces can stimulate more sales of personal plug-in hybrid electric vehicles instead of personal battery electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deployment priority of public charging speeds for increasing battery electric vehicle usability

To inform charger deployment decisions, this paper aims to understand the potential utilization and deployment priority for public charging infrastructure. A data-driven Cumulative Public Recharging (CPR) model is developed to explore the travel patterns by using 2017 National Household Travel Survey data. Given the daily trip sequence, trip distance, and dwell times, the study examines the daily expected driving range and BEV feasibility under different charging speeds, battery capacity, and charging behaviors. The results suggest that more advanced public chargers increase the daily expected driving range. Home charging is sufficient for most daily short-distance trips while public chargers are still needed for medium- and long-distance trips. Extreme fast charging (xFC) may not be necessary for people with home charging but could be more useful for people without home charging and for urgent charging. In conclusion, xFC becomes even less important to drivers with longer BEV ranges, a finding that contradicts conventional thinking.

33 ADVANCED PROPULSION SYSTEMS↗

Decarbonization pathways for the residential sector in the United States

We report residential GHG emissions in the United States are driven in part by a housing stock where onsite fossil combustion is common, home sizes are large by international standards, energy efficiency potential is large and electricity generation in many regions is GHG intensive. In this analysis, we assess decarbonization pathways for the US residential sector to 2060, through 108 scenarios describing housing stock evolution, new housing characteristics, renovation levels and clean electricity. The lowest emission pathways involve very rapid decarbonization of electricity supply alongside extensive renovations to existing homes, including improving thermal envelopes and heat pump electrification of heating. Reducing the size and increasing the electrification of new homes provide further emission cuts and combining all strategies enables reductions of 91% between 2020 and 2050. The potential of individual mitigation strategies shows great regional variation. Reaching zero emissions will require simultaneous deployment of multiple strategies and greater reduction of embodied emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Range Hood Use and Effectiveness in Reducing Indoor Air Pollution During Gas and Induction Cooking

The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. The study installed electric induction stoves and repeated measurements over three 2-week intensive periods, at baseline and at the end of two consecutive 3-month study phases. Stove replacements occurred at the start of Phase 1 or Phase 2 by random assignment. There were 4184 cooking events identified by automated analysis of time-series data from temperature sensors mounted above the cooktops and 1038 related range hood usage events detected from data recorded by anemometers, smart plugs, or motor loggers. Analysis of 1-minute resolved PM2.5 and NO 2 data identified and quantified 2685 PM 2.5 events and 2606 NO 2 events. Range hood use was characterized as a binary variable (>3 min vs. <3 min use). Range hood use was more common during cooking events associated with particle emissions and longer cooking durations. PM 2.5 concentrations during events with range hood use were comparable to those without use, which could result from limited effectiveness or if range hoods were preferentially used during higher-emission cooking scenarios. In homes with gas cooking, integrated NO 2 concentrations were about 45 percent higher during cooking events with no range hood use compared to those range hood use. The lowest pollutant levels were observed when the range hood operated for more than half of the cooking duration. These findings show that operation of venting range hood during cooking can substantially reduce short-term indoor exposure NO 2 in homes with gas cooking.

Fang, Yi↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory and field validation of the performance benefits and costs of thin triple-pane windows in residential buildings

The adoption of high-performance triple-pane windows that significantly reduce heat transfer has been slow, in part because they are thicker, heavier, and more costly than double-pane windows. One path to increase adoption of triple-pane windows is to replace the conventional double-glazing insulated glass unit (IGU) with a modified triple-glazing design that uses a very thin central pane of glass. This thinner triple-pane IGU can then be “dropped in” to the double-pane IGU pocket without requiring major modifications to frame design. The Department of Energy sponsored laboratory and field testing of thin triple-pane windows by Pacific Northwest National Laboratory. This article presents findings from both the Lab Homes study and subsequent field demonstrations carried out over a 3-year period (2020–2023). The laboratory and field studies demonstrated the manufacturing and distribution feasibility of thin triple-pane windows, successfully installed at multiple sites, using double-pane frames from four different manufacturers and thin triple-pane IGUs from two different manufacturers. Compared to a home with double-pane, clear-glass windows, testing demonstrated average whole-home heating energy savings of 12% and cooling energy savings of 27% for thin triple-pane windows. Improvements in comfort, sound insulation, and condensation potential were noted in both laboratory and field studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗