In situ conversion process utilizing a closed loop heating system

An in situ conversion system for producing hydrocarbons from a subsurface formation is described. The system includes a plurality of u-shaped wellbores in the formation. Piping is positioned in at least two of the u-shaped wellbores. A fluid circulation system is coupled to the piping. The fluid circulation system is configured to circulate hot heat transfer fluid through at least a portion of the piping to form at least one heated portion of the formation. An electrical power supply is configured to provide electrical current to at least a portion of the piping located below an overburden in the formation to resistively heat at least a portion of the piping. Heat transfers from the piping to the formation.

42 ENGINEERING↗

Electron-ion equilibrium and shock precursors in the northeast limb of the Cygnus Loop

We present an observational study using high-resolution echelle spectroscopy of collisionless shocks in the Cygnus Loop supernova remnant. Measured Hα line profiles constrain pre-shock heating processes, shock speeds, and electron-ion equilibration (T{sub e} /T{sub i} ). The shocks produce faint Hα emission line profiles, which are characterized by narrow and broad components. The narrow component is representative of the pre-shock conditions, while the broad component is produced after charge transfer between neutrals entering the shock and protons in the post-shock gas, thus reflecting the properties of the post-shock gas. We observe a diffuse Hα region extending about 2.'5 ahead of the shock with line width ∼29 km s{sup –1}, while the Hα profile of the shock itself consists of broader than expected narrow (36 km s{sup –1}) and broad (250 km s{sup –1}) components. The observed diffuse emission arises in a photoionization precursor heated to about 18,000 K by He I and He II emission from the shock, with additional narrow component broadening originating from a thin cosmic-ray precursor. Broad to narrow component intensity ratios of ∼1.0 imply full electron-ion temperature equilibration T{sub e} ≅ T{sub i} in the post-shock region. Broad component line widths indicate shock velocities of about 400 km s{sup –1}. Combining the shock velocities with proper motions suggests that the distance to the Cygnus Loop is ∼890 pc, significantly greater than the generally accepted upper limit of 637 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear fusion powered Titan aircraft

This paper discusses a system for Titan exploration enabled by nuclear fusion power. Titan is one of the most interesting locations in the solar system with a thick atmosphere, surface oceans, under-ice oceans and complex terrain. This paper provides a conceptual design of a fusion-powered system to explore many parts of Titan and enable the use of high-power instruments. The design includes a fusion-powered orbital transfer vehicle and an electric Titan science aircraft. A Direct Fusion Drive (DFD) propulsive engine could bring a sizable spacecraft to Titan orbit in less than two years. A second fusion reactor, configured as a closed-loop power generator, would be used for an electric Titan science aircraft. Both reactors are based on the Princeton Field-Reversed Configuration (PFRC) concept which combines an FRC with a magnetic mirror. PFRC uses a novel radio-frequency plasma heating system and deuterium-helium-3 fuel. A lower temperature plasma flows around the closed-field FRC region removing the fusion products. In the DFD propulsive configuration, this secondary flow permits direct and variable thrust and exhaust velocity. The science aircraft would do a powered entry to Titan and then have the capability to fly anywhere on the moon at subsonic speeds. The DFD-powered transfer vehicle would allow the in-orbit transfer stage to change inclination as needed to cover different areas of the surface.

33 ADVANCED PROPULSION SYSTEMS↗

THE RISE OF ACTIVE REGION FLUX TUBES IN THE TURBULENT SOLAR CONVECTIVE ENVELOPE

We use a thin flux tube model in a rotating spherical shell of turbulent convective flows to study how active region scale flux tubes rise buoyantly from the bottom of the convection zone to near the solar surface. We investigate toroidal flux tubes at the base of the convection zone with field strengths ranging from 15 kG to 100 kG at initial latitudes ranging from 1{sup 0} to 40{sup 0} with a total flux of 10{sup 22} Mx. We find that the dynamic evolution of the flux tube changes from convection dominated to magnetic buoyancy dominated as the initial field strength increases from 15 kG to 100 kG. At 100 kG, the development of {Omega}-shaped rising loops is mainly controlled by the growth of the magnetic buoyancy instability. However, at low field strengths of 15 kG, the development of rising {Omega}-shaped loops is largely controlled by convective flows, and properties of the emerging loops are significantly changed compared to previous results in the absence of convection. With convection, rise times are drastically reduced (from years to a few months), loops are able to emerge at low latitudes, and tilt angles of emerging loops are consistent with Joy's law for initial field strengths of {approx}>40 kG. We also examine other asymmetries that develop between the leading and following legs of the emerging loops. Taking all the results together, we find that mid-range field strengths of {approx}40-50 kG produce emerging loops that best match the observed properties of solar active regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Current loop coalescence studied by 3-D electromagnetic particle code

Solar flare plasma data from the Yohkoh satellite is analyzed. The interactions of current loops were observed in the active regions on the Sun. This observation pointed out the importance of the idea that the solar flare is generated by the coalescence of current loops. The three dimensional electromagnetic particle simulations are to help in understanding the global interaction between two current loops including the evolution of the twist of loops due to instabilities. Associated rapid dynamics of current loop coalescence such as reconnection, shock waves and associated kinetic processes such as energy transfer, acceleration of particles, and electromagnetic emissions are to be studied by the code to complement analytical theories and magnetohydrodynamic simulations of the current loop coalescence. The simulation results show the strong interactions between two current loops, beam and whistler instabilities, and associated parallel and perpendicular particle heating.

Nishikawa, Ken-Ichi↗

A new linearized theory of laminar film condensation of two phase annular flow in a capillary pumped loop

Future large space based facilities, such as Space Station, will require energy management systems capable of transporting tens of kilowatts of heat over a hundred meters or more. This represents better than an order of magnitude improvement over current technology. Two-phase thermal systems are currently being developed to meet this challenge. Condensation heat transfer plays a very important role in this system. The present study attempts an analytic solution to the set of linearized partial differential equations. The axial velocity and temperature functions were found to be Bessel functions which have oscillatory behavior. This result agrees qualitatively with the experimental evidence from tests at both NASA Goddard Space Flight Center and elsewhere.

Hsu, Y. K.↗

Recovery Act: Novel Oxygen Carriers for Coal-fueled Chemical Looping (Final Report: January 1 st , 2010 – February 28 th , 2013)

Chemical Looping Combustion (CLC) could totally negate the necessity of pure oxygen by using oxygen carriers for purification of CO 2 stream during combustion. It splits the single fuel combustion reaction into two linked reactions using oxygen carriers. The two linked reactions are the oxidation of oxygen carriers in the air reactor using air, and the reduction of oxygen carriers in the fuel reactor using fuels (i.e. coal). Generally metal/metal oxides are used as oxygen carriers and operated in a cyclic mode. Chemical looping combustion significantly improves the energy conversion efficiency, in terms of the electricity generation, because it improves the reversibility of the fuel combustion process through two linked parallel processes, compared to the conventional combustion process, which is operated far away from its thermo-equilibrium. Under the current carbon-constraint environment, it has been a promising carbon capture technology in terms of fuel combustion for power generation. Its disadvantage is that it is less mature in terms of technological commercialization. In this DOE-funded project, accomplishment is made by developing a series of advanced copper-based oxygen carriers, with properties of the higher oxygen-transfer capability, a favorable thermodynamics to generate high purity of CO 2 , the higher reactivity, the attrition-resistance, the thermal stability in red-ox cycles and the achievement of the auto-thermal heat balance. This will be achieved into three phases in three consecutive years. The selected oxygen carriers with final-determined formula were tested in a scaled-up 10kW coal-fueled chemical looping combustion facility. This scaled-up evaluation tests (2-day, 8-hour per day) indicated that, there was no tendency of agglomeration of copper-based oxygen carriers. Only trace-amount of coke or carbon deposits on the copper-based oxygen carriers in the fuel reactor. There was also no evidence to show the sulphidization of oxygen carriers in the system by using the high-sulfur-laden asphalt fuels. In all, the scaled-up test in 10 kW CLC facility demonstrated that the preparation method of copper-based oxygen carrier not only help to maintain its good reactivity, also largely minimize its agglomeration tendency.

20 FOSSIL-FUELED POWER PLANTS↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

RiverHeath: Neighborhood Loop Geothermal Exchange System

The goal of the RiverHeath project is to develop a geothermal exchange system at lower capital infrastructure cost than current geothermal exchange systems. The RiverHeath system features an innovative design that incorporates use of the adjacent river through river-based heat exchange plates. The flowing water provides a tremendous amount of heat transfer. As a result, the installation cost of this geothermal exchange system is lower than more traditional vertical bore systems. Many urban areas are located along rivers and other waterways. RiverHeath will serve as a template for other projects adjacent to the water.

15 GEOTHERMAL ENERGY↗

Investigation of nuclear graphite emissivity behaviors at various temperatures and oxidation degrees - 18763

Air Ingress into the primary loop is generally considered as one of the most likely severe accidents that could occur in High Temperature Gas-cooled Reactors (HTGRs). With air ingress, the graphite materials would be oxidized resulting in decreased graphite structure strength and release of harmful gases. As the main passive heat transfer mechanism during air ingress, heat transfer by radiation has high efficiency due to high temperature fuels in HTGRs. However, it is found that oxidation of fuel cladding affects the radiation heat transfer of graphite components. The purpose of the current study is to propose an empirical model that predicts the normal spectral emissivity ({lambda}=1.55 {mu}m) of the IG-110 at various temperatures and oxidation degrees. In this study, the emissivities of IG-110 at 0.0 burn-off, 4.44% burn-off and 8.90% burn-off were measured by employing IR thermometer and K-type thermocouples at four different temperatures corresponding to 600 deg. C, 700 deg. C, 800 deg. C and 900 deg. C. An empirical model of the spectral emissivity as a function of temperature and oxidation degree was proposed and validated against experimental data. In addition, the emissivity measurements revealed that, during air ingress, HTGRs would experience degraded radiating heat transfer due to graphite oxidation over certain temperature range. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CURRENT SHEET ENERGETICS, FLARE EMISSIONS, AND ENERGY PARTITION IN A SIMULATED SOLAR ERUPTION

We investigate coronal energy flow during a simulated coronal mass ejection (CME). We model the CME in the context of the global corona using a 2.5D numerical MHD code in spherical coordinates that includes coronal heating, thermal conduction, and radiative cooling in the energy equation. The simulation domain extends from 1 to 20 R{sub s} . To our knowledge, this is the first attempt to apply detailed energy diagnostics in a flare/CME simulation when these important terms are considered in the context of the MHD equations. We find that the energy conservation properties of the code are quite good, conserving energy to within 4% for the entire simulation (more than 6 days of real time). We examine the energy release in the current sheet as the eruption takes place, and find, as expected, that the Poynting flux is the dominant carrier of energy into the current sheet. However, there is a significant flow of energy out of the sides of the current sheet into the upstream region due to thermal conduction along field lines and viscous drag. This energy outflow is spatially partitioned into three separate components, namely, the energy flux flowing out the sides of the current sheet, the energy flowing out the lower tip of the current sheet, and the energy flowing out the upper tip of the current sheet. The energy flow through the lower tip of the current sheet is the energy available for heating of the flare loops. We examine the simulated flare emissions and energetics due to the modeled CME and find reasonable agreement with flare loop morphologies and energy partitioning in observed solar eruptions. The simulation also provides an explanation for coronal dimming during eruptions and predicts that the structures surrounding the current sheet are visible in X-ray observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Spouted Bed Reactor for Chemical Looping Combustion

We have investigated a novel gas/solid contacting configuration for chemical looping combustion (CLC) with potential operating benefits. CLC configurations are typically able to achieve high fuel conversion efficiencies at the expense of high operating costs and low system reliability. The spouted fluid bed (SB) was identified as an improved reactor configuration for CLC, since it typically exhibits high heat transfer rates and offers the ability to use lower gas flows for material movement compared to bubbling beds (BB). Multiphase Flow with Interphase eXchanges (MFIX) software was used to establish a spouted fluid bed reactor design. An experimental setup was built to supplement the model. The experimental setup was also modified for testing under high temperature, reacting conditions (1073–1273 K). The setup was operated in either a spouted fluid bed or a bubbling bed regime to compare the performance attributes of each. Results for the reactor configurations are presented for CLC using a mixture of carbon monoxide and hydrogen as fuel. Compared to the bubbling bed, the spouted fluid bed reactor achieved an equivalent or better fuel conversion at a lower pressure drop over the material bed. The spouted fluid bed design represents a viable configuration to improve gas/solid contacting for efficient fuel conversion, lower energy requirements for material movement and increase operational robustness for CLC. The research laid the groundwork for future research into a multi-phase reacting flow CLC system. The system will be developed from computational fluid dynamic modeling and pilot-scale testing to expedite the development of CLC technologies.

Energy & Fuels↗

Development and parametric evaluation of the prototype 2 and 3 flash evaporators

Development of the Prototype 2 and 3 flash evaporator heat sinks which vaporize an expendable fluid to cool a heat transport fluid loop is reported. The units utilize Freon 21 as the heat transport fluid and water as the expendable fluid to meet the projected performance requirements of the space shuttle for both on-orbit and ascent/reentry operations. The evaporant is pulse-sprayed by on-off control onto heat transfer surfaces containing the transport fluid and exhausted to the vacuum environment through fixed area exhaust ducts.

Hixon, C. W.↗

Quantification of functional impact classification on the current U.S. nuclear fleet

Currently, nuclear power generates only a small fraction of the world's electricity, though it does have the potential to meet the needs of the world as long as its production can compete with the alternative energy base load producers. In U.S the commercial nuclear fleet comprises of Light Water Reactors (LWRs), consisting of Pressurized Water Reactors (PWRs) and Boiling Water Reactors (BWRs). Many plants experience multiple events each year, which lead to reactor trips or scrams. This subsequently leads to plants being off the grid, which is not an economically favorable situation in the current energy markets. This study helps identify functional impact (FI) event categories for both PWR's and BWR's. Understanding that not all events and their causes can be anticipated, current industry best practices implement lessons learned to provide challenges and issues identification. In turn these are studied to achieve improved operational practices, and design modifications. This leads to overall enhanced resiliency. FI groups are the categories of initiating events (IE). IEs are unplanned events that occur while a nuclear plant is in critical operation, and requires that the plant be shut down to achieve a stable state. When a risk cannot be eliminated, IEs are identified and studied to reduce the risk and contribute to the identification of mitigations, safer designs and operational practices. Breaking IE events into groups' results in the classification of FI groups. A FI group is a risk-significant event category that could impact the ability of a NPP to remove decay heat from the reactor. Inability to remove decay heat from the reactor has the potential to lead to core damage. For an event to be considered a FI, it must be associated with a manual or automatic reactor trip, irrespective of the order of events. In addition, the plant must be at or above the point of adding heat and the event must happen before or shortly after a reactor trip. One or more FIs may be identified in any individual reactor trip sequence. The relationship between FI sequence, and/or frequency per a plant event is outside the scope of this paper. For example, the loss of offsite power (LOOP) can occur from eternal events (i.e. weather, human, wildlife etc.). This results in an event that requires a transfer of power to an emergency source, such as a generator, which produces a reactor trip and then a closure of main steam isolation valves (MSIVS). The FI applicable to this reactor trip sequence would be LOOP and closure of at least one MSIV in each main steam line. The results presented herein are focused on the analysis and evaluation of FI event categories. Only FI categories that can be found in IE studies, Initialing Events Spreadsheet and are recorded in a historical review of Licensee Event Reports (LERs) from 1988 through 2013. The results of this analysis can support plant decisions, design, procedures, and identify weakness.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical Simulation of AFP Nip Point Temperature Prediction for Complex Geometries

Material placement at the ideal nip point temperature over complex surfaces with uniformity across the width of the compaction rollers results in optimized part properties for Automated Fiber Placement (AFP) processes. However, current AFP systems utilize heat control models and methodologies, based on multiple process parameters such as feed-rate and orientation, that are mostly open-loop. Here, infrared (IR) heater input is calibrated as a function of process parameters during machine qualification. This work presents a numerical simulation to predict arrayed-infrared (AIR) emitter radiation onto a substrate that includes view factor implementation, IR radiative heat flow calculation, energy rate balance, and a transient heat transfer model. The purpose of this numerical model is to predict nip point temperature on complex surfaces, serving as a baseline for a new arrayed-infrared (AIR) thermoset heater to improve AFP process control. It is anticipated that this simulation will accurately control the temperature for high-speed AFP layup of complex geometries. An anticipated result of an AIR heater system is that material calibration and testing will be reduced as temperature is instantaneously monitored and controlled. Therefore, temperature across the roller width will be uniform during placement of complex parts, independent of their geometry.

Xia, Kaishu↗

Chemistry control and corrosion mitigation of heat transfer salts for the fluoride salt reactor (FHR)

The Molten Salt Reactor Experiment (MSRE) was a prototype nuclear reactor which operated from 1965 to 1969 at Oak Ridge National Laboratory. The MSRE used liquid fluoride salts as a heat transfer fluid and solvent for fluoride based {sup 235}U and {sup 233}U fuel. Extensive research was performed in order to optimize the removal of oxide and metal impurities from the reactor's heat transfer salt, 2LiF-BeF{sub 2} (FLiBe). This was done by sparging a mixture of anhydrous hydrofluoric acid and hydrogen gas through the FLiBe at elevated temperatures. The hydrofluoric acid reacted with oxides and hydroxides, fluorinating them while simultaneously releasing water vapor. Metal impurities such as iron and chromium were reduced by hydrogen gas and filtered out of the salt. By removing these impurities, the corrosion of reactor components was minimized. The Univ. of Wisconsin - Madison is currently researching a new chemical purification process for fluoride salts that make use of a less dangerous cleaning gas, nitrogen trifluoride. Nitrogen trifluoride has been predicted as a superior fluorinating agent for fluoride salts. These purified salts will subsequently be used for static and loop corrosion tests on a variety of reactor materials to ensure materials compatibility for the new FHR designs. Demonstration of chemistry control methodologies along with potential reduction in corrosion is essential for the use of a fluoride salts in a next generator nuclear reactor system. (authors)