Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This paper presents a generic and multifunctional electromagnetic transient (EMT) dynamic model of grid-following (GFL) inverter-based resources (IBRs) using the PSCAD software platform. The features of the model include flexibility in selecting various types and combinations of DC sources covering photovoltaic modules, battery modules, and ideal DC-source modules as well as flexibility in selecting either switching or averaged models of the inverter. This model also covers exhaustive lists of controller algorithm, including open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control, and conventional current control designed in the dq-domain, the ..alpha....beta.. -domain, and the positive-/negative-sequence domain. Moreover, this model is equipped with flexibility in selecting various types of current-limiting schemes, including saturation-based and latching-based current limiters, and anti-windup protection. Also, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by complying with IEEE Std. 2800. The generality in the power circuits and the multifunctional options in the operation and control of the developed EMT model make it suitable for both academia and industry to study various power system aspects, including, but not limited to, the fault behavior of GFL IBRs, the impacts on the protection system, and the transient stability of a system interfaced with large numbers of GFL IBRs.

integrated circuit modeling↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Line Faults Classification Using Machine Learning on Three Phase Voltages Extracted from Large Dataset of PMU Measurements

An end-to-end supervised learning method is developed to classify transmission line faults in a twoyear field-recorded dataset that includes synchronized measurements of three-phase voltages recorded by 38 Phasor Measurement Units (PMU) sparsely located in in the US Western Grid interconnection. Statistical analysis is performed to extract features from this large dataset to train Support Vector Machine (SVM), Random Forest (RF), and eXtreme Gradient Boosting (XGBoost) classifiers initially. The training further leverages a simulated dataset from a synthetic grid with 12 PMUs to increase the number of faults of types infrequently seen in the field-recorded dataset. Training the classification models with the combined dataset resulted in a classification accuracy of 97.7%. This is a significant improvement over 89.7% to 92.5% accuracy obtained by relying on the field-recorded dataset alone.

47 OTHER INSTRUMENTATION↗

An Advanced Synchronized Time Digital Grid Twin Testbed for Relay Misoperation Analysis of Electrical Fault Type Detection Algorithms

Distributed energy resources and the number of relays are expected to rise in modern electrical grids; consequently, relay misoperations are also expected to grow. Relays can detect electrical fault types using an internal algorithm and can display the result using light indicators on the front of the relay. However, some relays’ internal algorithms for predicting types of electrical faults could be improved. This study assesses a relay’s external and internal algorithms with an Advanced Synchronized Time Digital Grid Twin (ASTDGT) testbed with paired relays. A misoperation relay analysis focused on measuring the accuracy of using the boundary admittance (the external algorithm) versus the set-default (the internal algorithm) relay method to determine the electrical fault types was performed. In this study, the internal and external relay algorithms were assessed with a synchronized time digital grid twin testbed using a real-time simulator. This testbed evaluated two sets of logic at the same time with the digital grid twin and paired relays in the loop. Different types of electrical faults were simulated, and the relays’ recorded events and electrical fault light indicator states were collected from the human–machine interfaces. This ASTDGT testbed with paired relays successfully evaluated the relay algorithm misoperations. The boundary admittance method had an accuracy of 100% for line-to-line, line-to-ground, and line-to-line ground faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-temperature Pumping of Silicon for Thermal Energy Grid Storage

As the cost of renewable energy falls below fossil fuels, the key barrier to widespread sustainable electricity has become availability on demand. Energy storage can enable dispatchable renewables, but only with drastic cost reductions compared to current batteries. One electricity storage concept that could enable these cost reductions stores electricity as sensible heat in an extremely hot liquid (>2000 °C) and uses multi-junction photovoltaics (MPV) as a heat engine to convert it back to electricity on demand, hours or days later. This paper follows previously reported technoeconomics and liquid containment, examining equipment that would be needed to exchange heat between resistive heaters, a molten silicon storage tank above 2000 °C, and a heat engine. Herein, we report on a pump that was designed and tested to circulate the liquid silicon between these three regions and the effect of spatial thermal cycling was simulated in models and experiments. While the pump successfully circulated silicon between 1800-2080 °C for ten hours, circulation with a temperature gradient caused it and other non-isothermal experiments to dissolve significantly due to the temperature dependent solubility of not only carbon, but also silicon carbide which otherwise protected the graphite infrastructure. Furthermore, methods to reduce dissolution and an alternative embodiment are presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improved Particle Swarm Algorithm Using Rubik’s Cube Topology for Bilevel Building Energy Transaction

Following the rapid growth of distributed energy resources (e.g., renewables, battery), localized peer-to-peer energy transactions are receiving more attention for multiple benefits, such as reducing power loss and stabilizing the main power grid. To promote distributed renewables locally, the local trading price is usually set to be within the external energy purchasing and selling price range. Consequently, building prosumers are motivated to trade energy through a local transaction center. This local energy transaction is modeled in bilevel optimization game. A selfish upper level agent is assumed with the privilege to set the internal energy transaction price with an objective of maximizing its arbitrage profit. Meanwhile, the building prosumers at the lower level will response to this transaction price and make decisions on electricity transaction amount. Therefore, this non-cooperative leader-follower trading game is seeking for equilibrium solutions on the energy transaction amount and prices. Additionally, a uniform local transaction price structure (purchase price equals selling price) is considered here. Aiming at reducing the computational burden from classical Karush–Kuhn–Tucker (KKT) transformation and protecting the private information of each stakeholder (e.g., building), swarm intelligence-based solution approach is employed for upper level agent to generate trading price and coordinate the transactive operations. On one hand, to decrease the chance of premature convergence in global-best topology, Rubik’s Cube topology is proposed in this study based on further improvement of a two-dimensional square lattice model (i.e., one local-best topology-Von Neumann topology). Rotating operation of the cube is introduced to dynamically changing the neighborhood and enhancing information flow at the later searching state. Several groups of experiments are designed to evaluate the performance of proposed Rubik’s Cube topology-based particle swarm algorithm. The results have validated the effectiveness of proposed topology and operators comparing with global-best version PSO and Von Neumann topology-based PSO and its scalability on larger scale applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Securing Vehicle Charging Infrastructure

As the US electrifies the transportation sector, cyber attacks targeting vehicle charging could bring consequences to electrical system infrastructure. This is a growing area of concern as charging stations increase power delivery and must communicate to a range of entities to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and are complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid communication system cybersecurity could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks - or public perception of such - ripples across the industry and has lasting and devastating effects. Unfortunately, there is no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured interfaces. Thus, comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project is providing the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team is creating a cybersecurity threat model and performing a technical risk assessment of EVSE assets, so that automotive, charging, and utility stakeholders can better protect customers, vehicles, and power systems in the face of new cyber threats.

33 ADVANCED PROPULSION SYSTEMS↗

Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS): A Probabilistic Approach

In this project, we employ a layered protection strategy incorporating advanced optimization and detection techniques using a probabilistic approach. The probabilistic approach is not only applied when detecting cyber attacks, but also incorporated in control strategies, which greatly increases the attacking difficulties. Hackers need to understand both probabilistic detection algorithms and uncertainty modeling methods in control in order to execute any effective attacks. The end-to-end solutions enable us to provide Building Intelligence with Layered Defense using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential bill impacts of dynamic electricity pricing on California utility customers

The rapid growth of renewable generation is creating challenges for the California grid in the form of the “duck curve,” with increasingly steep ramping required for conventional generation resources in the morning and evening, and growing curtailment of solar resources in midday periods. Time-varying electricity tariffs have received considerable attention as a tool to address these challenges, with a renewed recent focus on the potential for dynamic tariffs that vary to reflect conditions on the grid in near-real time. Consideration of dynamic tariffs may raise concerns about the financial impact on utility customers, especially for those who have limited flexibility to modify their electricity consumption in response. Specific areas of concern include electricity bills, bill volatility, and equity implications related to cost shifting among customer groups. In this paper we leverage smart meter data for more than 400,000 California utility customers, spanning residential, commercial, industrial, and agricultural customers, to assess potential customer bill impacts arising from a multi-component dynamic tariff . Specifically, we compute impacts on customer bills and bill volatility under the assumption of fully inelastic demand, i.e., where customers do not change their consumption patterns in response to the tariff. We also assess various approaches designing subscription load shapes that customers can pre-purchase as a hedge that may provide a measure of protection against large negative impacts, while still incentivizing the modification of loads on the margin. We compare and contrast the relative impacts on different customer classes and discuss benefits and pitfalls of different dynamic tariff structures and subscription load shapes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Non-Steady State Operation on Cooling Water Consumption at Coal- and Natural Gas-Fired Power Plants

Increased renewable energy penetration in the electricity grid in coming decades will result in more frequent cycling at thermal power plants. Simultaneously, thermal power plants may face water scarcity with declining availability of cooling water. Therefore, to enhance thermal power plants’ resiliency to water shortages it is important to understand how non-steady conditions due to cycling will impact cooling water consumption and withdrawal intensity. Non-steady operation at power plants has been previously shown to decrease power plant thermal efficiency. Energy balance models have also demonstrated that a decrease in thermal efficiency is expected to increase cooling water consumption intensity. Furthermore, past work has used operating hours data to show idling and cycling gaps where cooling systems operate more than corresponding generators. As a result, an increase in cycling behavior may impact cooling water consumption and withdrawal intensity. This study uses data from the Energy Information Administration (EIA) and Environmental Protection Agency (EPA) to quantify the impact of cycling cooling water consumption intensity for recirculating cooling systems and withdrawal intensity for once-through cooling systems using energy balance and statistical approaches. In a novel application of a fixed effects model to study the effect of temperature on cooling water consumption and withdrawal intensity, this study finds temperature was consistently expected to increase consumption intensity and withdrawal intensity. Non-steady state conditions do not increase cooling water consumption intensity with statistical significance across unit types. However, additional validation of cooling water data is required to confirm these observed trends due to the sensitivity of these findings to model form and concerns with data quality of the dependent variables, cooling water consumption and withdrawal.

20 FOSSIL-FUELED POWER PLANTS↗

Cybersecurity for Electric Vehicle Charging Infrastructure

As the U.S. electrifies the transportation sector, cyberattacks targeting vehicle charging could impact several critical infrastructure sectors including power systems, manufacturing, medical services, and agriculture. This is a growing area of concern as charging stations increase power delivery capabilities and must communicate to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid operator communication systems could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks — or public perception of such — would ripple across the industry and produce lasting effects. Unfortunately, there is currently no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured inter faces. Comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project provided the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team created a cybersecurity threat model and performed a technical risk assessment of EVSE assets across multiple manufacturers and vendors, so that automotive, charging, and utility stakeholders could better protect customers, vehicles, and power systems in the face of new cyber threats.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rubik’s Cube Topology Based Particle Swarm Algorithm for Bilevel Building Energy Transaction

Following the rapid growth of distributed energy resources (e.g. renewables, battery), localized peer-to-peer energy transactions are receiving more attention for multiple benefits, such as, reducing power loss, stabilizing the main power grid, etc. To promote distributed renewables locally, the local trading price is usually set to be within the external energy purchasing and selling price range. Consequently, building prosumers are motivated to trade energy through a local transaction center. This local energy transaction is modeled in bilevel optimization game. A selfish upper level agent is assumed with the privilege to set the internal energy transaction price with an objective of maximizing its arbitrage profit. Meanwhile, the building prosumers at the lower level will response to this transaction price and make decisions on electricity transaction amount. Therefore, this non-cooperative leader-follower trading game is seeking for equilibrium solutions on the energy transaction amount and prices. In addition, a uniform local transaction price structure (purchase price equals selling price) is considered here. Aiming at reducing the computational burden from classical Karush-Kuhn-Tucker (KKT) transformation and protecting the private information of each stakeholder (e.g., building), swarm intelligence based solution approach is employed for upper level agent to generate trading price and coordinate the transactive operations. On one hand, to decrease the chance of premature convergence in global-best topology, Rubiks Cube topology is proposed in this study based on further improvement of a two-dimensional square lattice model (i.e., one local-best topology-Von Neumann topology). Rotating operation of the cube is introduced to dynamically changing the neighborhood and enhancing information flow at the later searching state. Several groups of experiments are designed to evaluate the performance of proposed Rubiks Cube topology based particle swarm algorithm. The results have validated the effectiveness of proposed topology and operators comparing with global-best version PSO and Von Neumann topology based PSO and its scalability on larger scale applications.

Feng, Xiaochun↗

Criticality Accident Alarm System Modeling for the Uranium Processing Facility

The Criticality Accident Alarm System (CAAS) for the Uranium Processing Facility (UPF) provides coverage for two primary processing facilities. For UPF, detailed documentation and drawings of the design are readily available. While this design information allows for some CAAS modeling features to match the actual design with a high level of accuracy, assumptions and simplifications are necessary as it is unrealistic and unnecessary to replicate many aspects of the design. A set of modeling guidelines and techniques were used to develop consistency between the MCNP6 models. While ensuring conservatism, overly conservative choices must be avoided to demonstrate the minimum accident of concern can be detected. To ensure proper modeling choices were made for the final models, a group of parametric studies were performed to evaluate the impact on the dose rates detected at the individual detectors. Some of these modeling choices and/or associated parametric studies include: - Modeling the grid steel area above the detectors as homogeneous stainless steel and determining the impact on detectability with an increasing density. - Modeling the presence of equipment in close proximity to the CAAS detectors. - Determining an appropriate material density to represent miscellaneous items not specifically modeled. - Evaluating the impact of sprinkler activation. The results of UPF CAAS analyses show that the modeling assumptions made based on the detailed design and parametric studies are appropriate and demonstrate accurate yet conservative models have been developed for detecting minimum accident of concern within the UPF.

61 RADIATION PROTECTION AND DOSIMETRY↗

Transitioning GlideinWMS, a multi domain distributed workload manager, from GSI proxies to tokens and other granular credentials

GlideinWMS is a distributed workload manager that has been used in production for many years to provision resources for experiments like CERN’s CMS, many Neutrino experiments, and the OSG. Its security model was based mainly on GSI (Grid Security Infrastructure), using X.509 certificate proxies and VOMS (Virtual Organization Membership Service) extensions. Even when other credentials, like SSH keys, were used to authenticate with resources, proxies were also added all the time, to establish the identity of the requestor and the associated memberships or privileges. This single credential was used for everything and was, often implicitly, forwarded wherever needed. The addition of identity and access tokens and the phase-out of GSI forced us to reconsider the security model of GlideinWMS, to handle multiple credentials which can differ in type, technology, and functionality. Both identity tokens and access tokens are supported. GSI proxies even if no more mandatory, are still used, together with various JWT (JSON Web Token) based tokens and other certificates. The functionality of the credentials, defined by issuer, audience, and scope, also differ: a credential can allow access to a computing resource, or can protect the GlideinWMS framework from tampering, or can grant read or write access to storage, can provide an identity for accounting or auditing, or can provide a combination of any the formers. Furthermore, the tools in use do not include automatic forwarding and renewal of the new credentials so credential lifetime and renewal requirements became part of the discussion as well. In this paper, we will present how GlideinWMS was able to change its design and code to respond to all these changes.

97 MATHEMATICS AND COMPUTING↗