Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

An Introduction to Thermodynamic Performance Analysis of Aircraft Gas Turbine Engine Cycles Using the Numerical Propulsion System Simulation Code

This document is intended as an introduction to the analysis of gas turbine engine cycles using the Numerical Propulsion System Simulation (NPSS) code. It is assumed that the analyst has a firm understanding of fluid flow, gas dynamics, thermodynamics, and turbomachinery theory. The purpose of this paper is to provide for the novice the information necessary to begin cycle analysis using NPSS. This paper and the annotated example serve as a starting point and by no means cover the entire range of information and experience necessary for engine performance simulation. NPSS syntax is presented but for a more detailed explanation of the code the user is referred to the NPSS User Guide and Reference document (ref. 1).

Jones, Scott M.↗

Slag monitoring system for combustion chambers of steam boilers

The computer-based boiler performance system presented in this article has been developed to provide a direct and quantitative assessment of furnace and convective surface cleanliness. Temperature, pressure, and flow measurements and gas analysis data are used to perform heat transfer analysis in the boiler furnace and evaporator. Power boiler efficiency is calculated using an indirect method. The on-line calculation of the exit flue gas temperature in a combustion chamber allows for an on-line heat flow rate determination, which is transferred to the boiler evaporator. Based on the energy balance for the boiler evaporator, the superheated steam mass flow rate is calculated taking into the account water flow rate in attemperators. Comparing the calculated and the measured superheated steam mass flow rate, the effectiveness of the combustion chamber water walls is determined in an on-line mode. Soot-blower sequencing can be optimized based on actual cleaning requirements rather than on fixed time cycles contributing to lowering of the medium usage in soot blowers and increasing of the water-wall lifetime.

20 FOSSIL-FUELED POWER PLANTS↗

Water Vapor Sensors Go Sky-High to Assure Aircraft Safety

JPL used a special tunable diode laser, which NASA scientists could tune to different wavelengths, like a radio being tuned to different frequencies, to accurately target specific molecules and detect small traces of gas. This tunable diode laser was designed to emit near-infrared light at wavelengths absorbed by the gas or gases being detected. The light energy being absorbed by the target gas is related to the molecules present. This is usually measured in parts per million or parts per billion. Multiple measurements are made every second, making the system quick to respond to variations in the target gas. NASA scientists developed this technology as part of the 1999 Mars Polar Lander mission to explore the possibility of life-giving elements on Mars. NASA has since used the tunable diode laser-based gas sensor on aircraft and on balloons to successfully study weather and climate, global warming, emissions from aircraft, and numerous other areas where chemical gas analysis is needed. SpectraSensors, Inc., was formed in 1999 as a spinoff company of JPL, to commercialize tunable diode laser-based analyzers for industrial gas-sensing applications (Spinoff 2000). Now, the San Dimas, California-based firm has come back to the market with a new product featuring the NASA-developed instrument for atmospheric monitoring. This instrument is now helping aircraft avoid hazardous weather conditions and enabling the National Weather Service to provide more accurate weather forecasts.

Source record↗

Dynamic analysis of gas-core reactor system

A heat transfer analysis was incorporated into a previously developed model CODYN to obtain a model of open-cycle gaseous core reactor dynamics which can predict the heat flux at the cavity wall. The resulting model was used to study the sensitivity of the model to the value of the reactivity coefficients and to determine the system response for twenty specified perturbations. In addition, the model was used to study the effectiveness of several control systems in controlling the reactor. It was concluded that control drums located in the moderator region capable of inserting reactivity quickly provided the best control.

Turner, K. H., Jr.↗

Design of a diagnostic residual gas analyzer for the ITER divertor

One of the ITER diagnostics having reached an advanced design stage is a diagnostic RGA for the divertor, i.e. residual gas analysis system for the ITER divertor, which is intended to sample the divertor pumping duct region during the plasma pulse and to have a response time compatible with plasma particle and impurity lifetimes in the divertor region. Main emphasis is placed on helium (He) concentration in the ducts, as well as the relative concentration between the hydrogen isotopes (H2, D2, T2). Measurement of the concentration of radiative gases, such as neon (Ne) and nitrogen (N2), is also intended. Numerical modeling of the gas flow from the sampled region to the cluster of analysis sensors, through a long (~8m long, ~110mm diameter) sampling pipe terminating in a pressure reducing orifice, confirm that the desired response time (~1s for He or D2) is achieved with the present design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compliance Measurements of Fuel Cell Electric Vehicle Exhaust

The NREL Sensor Laboratory has been developing an analyzer that can verify compliance to the international United Nations Global Technical Regulation number 13 (GTR 13--Global Technical Regulation on Hydrogen and Fuel Cell Vehicles) prescriptive requirements pertaining to allowable hydrogen levels in the exhaust of fuel cell electric vehicles (FCEV) [1]. GTR 13 prescribes that the FCEV exhaust shall remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2, as verified with an analyzer with a response time (t90) of 300 ms or faster. GTR 13 has been implemented and is to serve as the basis for national regulations pertaining to hydrogen powered vehicle safety in the United States, Canada, Japan, and the European Union. In the U.S., vehicle safety is overseen by the Department of Transportation (DOT) through the Federal Motor Vehicle Safety Standards (FMVSS) and in Canada by Transport Canada through the Canadian Motor Vehicle Safety Standard (CMVSS). The NREL FCEV exhaust analyzer is based upon a low-cost commercial hydrogen sensor with a response time (t90) of less than 250 ms. A prototype analyzer and gas probe assembly have been constructed and tested that can interface to the gas sampling system used by Environment and Climate Change Canada's (ECCC) Emission Research and Measurement Section (ERMS) for the exhaust gas analysis. Through a partnership with Transport Canada, ECCC will analyze the hydrogen level in the exhaust of a commercial FCEV. ECCC will use the NREL FCEV Exhaust Gas analyzer to perform these measurements. The analyzer was demonstrated on a FCEV operating under simulated road conditions using a chassis dynamometer at a private facility.

CMVSS↗

Technical note: 21 Ne in the CoQtz-N quartz standard material

Intercomparison standards produced from mineral samples exposed to the natural cosmic ray flux are routinely used for interlaboratory comparison and normalization of measurements of the cosmogenic noble gases 3 He and 21 Ne. This effort is facilitated by the availability of multiple standard materials with a wide range of cosmogenic nuclide concentrations. The “CoQtz-N” quartz standard, which was originally produced and distributed as an intercomparison standard for cosmogenic 10 Be and 26 Al, has a significantly lower cosmogenic nuclide concentration than other mineral standards used for cosmogenic noble gas analysis and is therefore potentially useful for assessing the linearity of interlaboratory offsets across a wide range of concentrations. This paper reports 21 Ne analysis of 13 aliquots of CoQtz-N, interspersed with 14 aliquots of the commonly used CRONUS-A quartz standard, in three analytical sessions on two noble gas mass spectrometer systems. The excess 21 Ne concentration in CoQtz-N, normalized to the accepted value of 320 × 10 6 atoms g −1 for CRONUS-A, is 13.87 ± 0.24 × 10 6 atoms g −1 . Alternatively, the ratio of excess 21 Ne concentrations in CoQtz-N and CRONUS-A is 0.04330 ± 0.00077.

Balco, Greg [Lawrence Livermore National Laborator↗

Isotopic Composition of Carbon Dioxide Released from Confidence Hills Sediment as Measured by the Sample Analysis at Mars (SAM) Quadrupole Mass Spectrometer

In October 2014, the Mars Science Laboratory (MSL) "Curiosity" rover drilled into the sediment at the base of Mount Sharp in a location namsed Cionfidence Hills (CH). CH marked the fifth sample pocessed by the Sample Analysis at Mars (SAM) instrument suite since Curiosity arrived in Gale Crater, with previous analyses performed at Rocknest (RN), John Klein (JK), Cumberland (CB), and Windjana (WJ). Evolved gas analysis (EGA) of all samples has indicated H2O as well as O-, C- and S-bearing phases in the samples, often at abundances that would be below the detection limit of the CheMin instrument. By examining the temperatures at which gases are evolved from samples, SAM EGA data can help provide clues to the mineralogy of volatile-bearing phases when their identities are unclear to CheMin. SAM may also detect gases evolved from amorphous material in solid samples, which is not suitable for analysis by CheMin. Finally, the isotopic composition of these gases may suggest possible formation scenarios and relationships between phases. We will discuss C isotope ratios of CO2 evolved from the CH sample as measured with SAM's quadrupole mass spectrometer (QMS) and draw comparisons to samples previously analyzed by SAM.

Franz, H. B.↗

Nephele: An Entry Probe & Sonde Concept for a Venus Ride-Along or Small Spacecraft Mission

Nephele is a Venus atmospheric descent probe concept designed to analyze cloud, haze, and dust particles. It combines a unique set of technologies (Figure 1): recently developed thermal protection materials (3D-CC and HEEET), aerosol sampling technologies with heritage in both planetary and airborne science (high-speed inlets and particle separation), and rapid, robust optical analysis instruments (such as the VOLTR dual spectrometer). Nephele is designed to be complentary to other efforts such as DAVINCI and Venera-D, which target Venus atmospheric gas analysis, by specifically targeting cloud and haze particles.

Nephele↗

Steady-state canopy gas exchange: system design and operation

This paper describes the use of a commercial growth chamber for canopy photosynthesis, respiration, and transpiration measurements. The system was designed to measure transpiration via water vapor fluxes, and the importance of this measurement is discussed. Procedures for continuous measurement of root-zone respiration are described, and new data is presented to dispel myths about sources of water vapor interference in photosynthesis and in the measurement of CO2 by infrared gas analysis. Mitchell (1992) has described the fundamentals of various approaches to measuring photosynthesis. Because our system evolved from experience with other types of single-leaf and canopy gas-exchange systems, it is useful to review advantages and disadvantages of different systems as they apply to various research objectives.

NASA Discipline Number 61-10↗

Validation of SCALE for High Temperature Gas-Cooled Reactors Analysis

This report documents verification and validation studies carried out to assess the performance of the SCALE code system methods and nuclear data for modeling and analysis of High Temperature Gas-Cooled Reactor (HTGR) configurations. Validation data were available from the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhE Handbook), prepared by the International Reactor Physics Experiment Evaluation Project, for two different HTGR designs: prismatic and pebble bed. SCALE models have been developed for HTTR, a prismatic fuel design reactor operated in Japan and HTR-10, a pebble bed reactor operated in China. The models were based on benchmark specifications included in the 2009, 2010, and 2011 releases of the IRPhE Handbook. SCALE models for the HTR-PROTEUS pebble bed configuration at the PROTEUS critical facility in Switzerland have also been developed, based on benchmark specifications included in a 2009 IRPhE draft benchmark. The development of the SCALE models has involved a series of investigations to identify particular issues associated with modeling the physics of HTGRs and to understand and quantify the effect of particular modeling assumptions on calculation-to-experiment comparisons.

Ilas, Germina↗

Volatile Analyzer for Lunar Polar Missions

One of the major questions remaining for the future exploration of the Moon by humans concerns the presence of volatiles on our nearest neighbor in space. Observational studies, and investigations involving returned lunar samples and using robotic spacecraft infer the existence of volatile compounds particularly water [1]. It seems very likely that a volatile component will be concentrated at the poles in circumstances where low-temperatures exist to provide cryogenic traps. However, the full inventory of species, their concentration and their origin and sources are unknown. Of particular importance is whether abundances are sufficient to act as a resource of consumables for future lunar expeditions especially if a long-term base involving humans is to be established. To address some of these issues requires a lander designed specifically for operation at a high-lunar latitude. A vital part of the payload needs to be a volatile analyzer such as the Gas Analysis Package specifically designed for identification quantification of volatile substances and collecting information which will allow the origin of these volatiles to be identified [1]. The equipment included, particularly the gas analyzer, must be capable of operation in the extreme environmental conditions to be encountered. No accurate information yet exists regarding volatile concentration even for sites closer to the lunar equator (because of contamination). In this respect it will be important to understand (and thus limit) contamination of the lunar surface by extraneous material contributed from a variety of sources. The only data for the concentrations of volatiles at the poles comes from orbiting spacecraft and whilst the levels at high latitudes may be greater than at the equator, the volatile analyzer package under consideration will be designed to operate at the highest specifications possible and in a way that does not compromise the data.

Gibons, Everett K.↗

Uniform Whole Wafer Anisotropic Etching of Structural Ta Thin Films

Tantalum (Ta) has promise as a structural material for micromechanical sensors and actuators. Anisotropic etching of alpha (α) phase Ta is required for micromachining applications. Uniform thickness and etch across a full wafer are desirable features. An experimental investigation is conducted to study plasma etching rate and anisotropy in etching α -Ta in relation to pressure and gas flow ratio. A comparatively low toxicity gas, carbon tetrafluoride (CF4), and argon (Ar) are used. Spectrometry by optical emission spectrometry (OES) and residual gas analysis (RGA) are employed to characterize the plasma to gain insight into the etch mechanisms. At low flow, the etch rate is slow due to an inadequate supply of the etching gas, CF4. The etch rate is also slowed at high flow due to a reduced CF4 residence time. Flow and pressure conditions to achieve a good etch rate and vertical sidewalls are identified and explained by means of a full factorial experiment coupled with emission spectra. Finally, with these conditions, uniform etching of 2.5 μm thick α-Ta across a 4-inch wafer is demonstrated.

36 MATERIALS SCIENCE↗

Influence of Oxychlorine Phases During the Pyrolysis of Organic Molecules: Implications for the Quest of Organics on Mars with the SAM Experiment Onboard the Curiosity Rover

One among the main objectives of the Sample Analysis at Mars (SAM) experiment is the in situ molecular analysis of gases evolving from solid samples heated up to approximately 850 degrees Centigrade, and collected by Curiosity on Mars surface/sub-surface in Gale crater. With this aim, SAM uses a gas-chromatograph coupled to a quadrupole mass spectrometer (GC-QMS) devoted to separate, detect and identify both volatile inorganic and organic compounds. SAM detected chlorinated organic molecules produced in evolved gas analysis (EGA) experiments. Several of these were also detected by the Viking experiments in 1976. SAM also detected oxychlorine compounds that were present at the Phoenix landing site. The oxychlorines may be prevelant over much of the martian surface. The C1 to C3 aliphatic chlorohydrocarbons (chloromethane and di- and trichloromethane) detected by SAM were attributed to reaction products occurring between the oxychlorines phases and the organic compounds coming from SAM instrument background. But SAM also showed the presence of a large excess of chlorobenzene and C2 to C4 dichloroalkanes among the volatile species released by the Cumberland sample of the Sheepbed mudstone. For the first time in the history of the Mars exploration, this proved the presence of Mars indigenous organic material at the Mars' surface. However, the identification of the precursor organic compounds of these chlorohydrocarbons is difficult due to the complexity of the reactions occurring during the sample pyrolysis. Laboratory pyrolysis experiments have demonstrated that oxychlorines phases such as perchlorates and chlorates, decomposed into dioxygen and volatile chlorine bearing molecules (HCl and/or Cl2) during the pyrolysis. These chemical species can then react with the organic molecules present in the martian solid samples through oxidation, chlorination and oxychlorination processes.

Millan, M.↗

Impact of Dopants on Suppressing Gas Evolution from High-Nickel Layered Oxide Cathodes

Gas release from high-Ni layered-oxide cathodes (LiNi x Mn 1-x-y-z Co y Al z O 2 ; x > 0.8) can jeopardize the overall performance and safety characteristics of the cell. A comprehensive assessment of rational cathode design with common dopants, such as Ni, Co, Al, and Mn, to suppress gas evolution is crucial for battery safety, yet it remains to be conducted. Furthermore, we present an in-situ gas analysis on nine high-Ni cathode materials with online electrochemical mass spectrometry (OEMS). We show that regardless of the dopant, reactive oxygen release from the cathode lattice remains a critical process for gas evolution. A series of comparisons reveals that the intensity and onset point of gas release is strongly dependent on the cathode composition. Notably, Al and Mn are the most effective dopants to suppress gas evolution from the cathode at 4.4 V. We further highlight lattice stability limits, across these nine compositions, between 85 % to 93 % state of charge.

25 ENERGY STORAGE↗

Hydrogen Isotopic Composition of Water in the Martian Atmosphere and Released from Rocknest Fines

The Mars Science Laboratory Curiosity rover sampled the aeolian bedform called Rocknest as its first solid samples to be analyzed by the analytical instruments CheMin and SAM. The instruments ingested aliquots from a sieved sample of less than 150 micrometer grains. As discussed in other reports at this conference [e.g., 1], CheMin discovered many crystalline phases, almost all of which are igneous minerals, plus some 10s of percent of x-ray amorphous material. The SAM instrument is focused on understanding volatiles and possible organics in the fines, performing evolved gas analysis (EGA) with the SAM quadrapole mass spectrometer (QMS), isotope measurements using both the QMS and the tunable laser spectrometer (TLS), which is sensitive to CO2, water and methane, and organics with the gas chromatograph mass spectrometer (GCMS). As discussed in the abstract by Franz et al. [2] and others, EGA of Rocknest fines revealed the presence of significant amounts of H2O as well as O-, C- and S-bearing materials. SAM has also tasted the martian atmosphere several times, analyzing the volatiles in both the TLS and QMS [e.g., 3,4]. This abstract will focus on presentation of initial hydrogen isotopic data from the TLS for Rocknest soils and the atmosphere, and their interpretation. Data for CO2 isotopes and O isotopes in water are still being reduced, but should be available by at the conference.

Leshin, L. A.↗

Extreme Thermal Stabilization of Carborane–Cyanate Composites via B–N Dative-Bonded Boroxine Barriers

Enhancing the thermal stability of cyanate ester (CE) resins is crucial for high-temperature aerospace applications. This study elucidates the degradation mechanisms of CE composites reinforced with carborane additives, focusing on the formation of boron–nitrogen (B–N) dative bonds and their role in improving thermal resistance. Using thermogravimetric analysis, we examined char formation and evolved gases at multiple degradation stages. Reaction sequences and char products were characterized via Fourier transform infrared spectroscopy (FTIR), solid-state 13C and 11B NMR, and evolved gas analysis using mass spectrometry and FTIR. The solid-state 11B NMR was instrumental in detecting various boron oxidation states and the formation of B–N dative bonds during decomposition. These bonds facilitate cross-linking in the char phase, enhancing material integrity at elevated temperatures. However, in inert environments, the volatility of boron additives like carborane limits their effectiveness. These findings advance the understanding of CE composite degradation mechanisms and offer critical insights for developing high-temperature-resistant materials for aerospace applications.

Fourier transform infrared spectroscopy↗

Abstract - Cooperative Research and Development Agreement between Oxergy, Inc. and National Energy Technology Laboratory

The Raman Gas Analyzer (RGA) has been demonstrated to have an extremely fast response (<1 second), pressurized, multi-gas analysis capability. All but the noble gases are Raman active, although the Raman interaction is weak. The RGA uses a reflectively lined capillary as the optical cell, providing both a small sample volume for fast gas exchange, and a much greater Raman signal collection than traditional instrument configurations.

47 OTHER INSTRUMENTATION↗