Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

On the flow induced vibration of an externally excited nuclear reactor experiment

An in-pile, drop-in experiment design is presently being designed and studied for the near-term deployment within the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL); this experiment is termed the Miniplate-1 Large-B (MP-1 LB) Experiment. A number of explicit studies are performed during the design- and safety-related stage. Traditionally, a clear and logical methodology has been developed and utilized for analyses such as hydraulics, thermal-loads, mechanical loads, and others for these experiments. Recently a small component from a different experiment assembly mechanically separated while in the reactor’s core. While this experiment didn’t compromise the safety of the reactor, it led to a higher-level question which centered on whether the appropriate level of consideration was being made toward the fluid–structure-interactions of these experiments. The outcome yielded separate flow test experiments of like-for-like geometry in an experimental loop located at Oregon State University which produces experimental data compliant with applicable parts and requirements to ASME’s NQA-1 2008, 2009a standard – suitable for benchmark evaluation. Here, the objectives of this study are to (1) develop a process for handling and interpreting the mechanical response of the test elements during hydraulic testing, to (2) characterize the motion of a specific test element during a flow test which imposes a wide range of hydraulic conditions, and (3) provide objective observations toward the potential safety related implications that are tied to the synthesized data. The outcome of this study has led to a confident process in inspecting the experimental data, synthesized it for interpretation, identified several unique hydraulic characteristics of the experiment design which were previously unknown, and demonstrated that the likelihood for mechanical failure resulting from fluid-structure-interactions in the reactor is far below any criterion for concern of the element’s safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gate assisted Kelvin test structure to measure the electron and hole flows at the same nanowire contacts

A gate assisted Kelvin test structure based on Si nanowire field effect transistors has been designed and fabricated for the characterization of the transistor source/drain contacts. Because the Si nanowire field effect transistors exhibit ambipolar characteristics with electron current slightly lower than the hole current, we can select the type of carriers (electrons or holes) flowing through the same contacts and adjust the current by the applied gate voltage. In this way, we are able to measure the characteristics of the same contact with either pure electron or hole flow. In addition, we found that the nanowire contacts behave very differently depending on the current flow directions. This indicates that the source and drain contact resistance can be dramatically different. Such a gate assisted Kelvin Test structure will lead to future metrology and applications in nanoelectronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence P - Raw Data

Sequence P: Wake Flow Visualization, Upwind (P) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 15 m/s. Yaw angles of 0° to –60° were achieved. The blade tip pitch was 3°. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The aluminum blade tip designed to contain a smoke generator was installed, and counterweights were installed in the non-instrumented blade tip to compensate. The turbine was positioned at the appropriate yaw angle, and the smoke generator was ignited remotely. The campaign duration was 3 minutes for all tests except P1000000, which was 2 minutes. The file name convention was the standard format except for P10000A0, which indicated a 3° pitch angle. File P1000000 used a 12° pitch angle. After these two campaigns were collected, it was determined that all subsequent data should be collected with a 3° pitch angle. Pressure data were not acquired during this sequence, so all associated data values were flagged as not applicable by setting the measured values in the data file to 0.000 Pa. Corresponding pressure data are available from Sequence H for the 3° pitch angle test points. Flow visualization data obtained from wall- and ceiling-mounted video cameras were recorded to videotape. The camera locations and calibration procedures are described in Appendix J.

17 WIND ENERGY↗

Evaluation of the Impact of Thin Pours on Saltstone Properties

The proposed Saltstone Disposal Unit 6 (SDU6) is a larger structure than the SDU4 cells and larger than the disposal units (SDU2, SDU3, and SDU5) currently in use or under construction. The additional capacity provided by SDU6 is desired to reduce life cycle costs and support site accelerated closure goals. The larger size of the planned SDU6 could result in saltstone being placed in thinner lifts as the unit is filled. This study was performed to determine whether thinner layers of saltstone negatively impact the performance of the waste form. A larger number of cold joints could potentially result in increased drying, salt deposition, and surface oxidation. A matrix of samples was prepared to simulate thin pours ranging from 0.5 to 6 inches thick. Each sample was cured for at least 28 days prior to further characterization. Leachability results showed that there is no obvious impact of the number of grout layers on the Leachability Index values for Na and NO 3 . The concentrations of Cr, NO 2 , and C 2 O 4 were below detection limits for all of the leachates. No attempt was made to evaluate the oxidation of these samples since no measureable Cr was leached, although this would appear to indicate that Cr in the samples remained reduced for cold joints with surfaces exposed for approximately four days. The results of hydraulic conductivity measurements showed that the number of cold joints in the samples did not have a significant impact on the measured values for the vertical lift orientation (i.e., when the flow path is perpendicular to the cold joints). For the horizontal lift orientation (i.e., when the flow path is parallel to the cold joints), the number of cold joints in the samples also did not appear to have a significant impact on hydraulic conductivity. The measured hydraulic conductivity was faster when the flow path was parallel to the cold joints as compared to when the flow path was perpendicular to the cold joints. Percolation testing showed increased flow when the number of cold joints was increased. Compressive strength testing showed that the maximum load at the onset of cracking was reduced by approximately 26% for those samples that contained cold joints as compared to the monolithic samples. The number of cold joints in the sample had no significant impact on the maximum load prior to cracking. The porosity of the samples was not influenced by cold joints. This result was expected as the porosity is a material property affected by the properties of the components (premix and salt solution) and the water to premix ratio. Overall, the only obvious impact of cold joints in the samples was to significantly increase hydraulic conductivity in the direction parallel to the cold joints. An increasing number of cold joints (thin layers) in the simulated saltstone samples did not exacerbate this effect, nor did it have a negative impact on the Leachability Indices or porosity for surfaces exposed for approximately four days. The presence of a cold joint reduced the compressive strength of the material, although this impact was seen regardless of the number of cold joints in the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining the impacts of venoarterial extracorporeal membrane oxygenation on cerebral oxygenation using a one-dimensional blood flow simulator

Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is a mechanical system that provides rapid and short-term support for patients with cardiac failure. In many patients, pulmonary function is also impaired, resulting in poorly-oxygenated cardiac outflow competing against well-oxygenated VA-ECMO outflow, a condition known as North-South syndrome. North-South syndrome is a primary concern because of its potential to cause cerebral hypoxia, which has a critical influence on neurological complications often seen in this patient population. In order to reduce ischemic neurological complications, it is important to understand how clinical decisions regarding VA-ECMO parameters influence blood oxygenation. In our work, we studied the impacts of flow rate and cannulation site on oxygenation using a one-dimensional (1D) model to simulate blood flow. Our model was initially tested by comparing blood flow results to those observed from experimental work in VA-ECMO patients. The 1D model was combined with a two-phase flow model to simulate oxygenation. Additionally, the influence of various other clinician-tunable parameters on oxygenation in the common carotid arteries (CCAs) were tested, including, blood viscosity, cannula position within the insertion artery, heart rate, and systemic vascular resistance (SVR), as well as geometrical changes such as arterial radius and length. Our results indicated that blood oxygenation to the brain strongly depended on the cannula insertion site and the VA-ECMO flow rate with a weaker but potentially significant dependence on arterial radius. During femoral cannulation, VA-ECMO flow rates greater than ~4.9 L/min were needed to perfuse the CCAs. However, axillary and central cannulation began to perfuse the CCAs at significantly lower flow (~1 L/min). These results may help explain the incidence of cerebral hypoxia in this patient population and the common need to change cannulation strategies during treatment to address this clinical problem. While this work describes patient-averaged results, determining these relationships between VA-ECMO parameters and cerebral hypoxia is an important step towards future work to develop patient-specific models that clinicians can use to improve outcomes.

1D blood flow↗

Experimental Simulation of Meteorite Ablation during Earth Entry Using a Plasma Wind Tunnel

Three different types of rocks were tested in a high enthalpy air plasma flow. Two terrestrial rocks, basalt and argillite, and an ordinary chondrite, with a 10 mm diameter cylindrical shape were tested in order to observe decomposition, potential fragmentation, and spectral signature. The goal was to simulate meteoroid ablation to interpret meteor observation and compare these observations with ground based measurements. The test flow with a local mass-specific enthalpy of 70 MJ kg{sup −1} results in a surface heat flux at the meteorite fragment surface of approximately 16 MW m{sup −2}. The stagnation pressure is 24 hPa, which corresponds to a flight condition in the upper atmosphere around 80 km assuming an entry velocity of 10 km s{sup −1}. Five different diagnostic methods were applied simultaneously to characterize the meteorite fragmentation and destruction in the ground test: short exposure photography, regular video, high-speed imaging with 10 kHz frame rate, thermography, and Echelle emission spectroscopy. This is the first time that comprehensive testing of various meteorite fragments under the same flow condition was conducted. The data sets indeed show typical meteorite ablation behavior. The cylindrically shaped fragments melt and evaporate within about 4 s. The spectral data allow the identification of the material from the spectra which is of particular importance for future spectroscopic meteor observations. For the tested ordinary chondrite sample a comparison to an observed meteor spectra shows good agreement. The present data show that this testing methodology reproduces the ablation phenomena of meteoritic material alongside the corresponding spectral signatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Permeability of laboratory-formed methane-hydrate-bearing sand: Measurements and observations using x-ray computed tomography

Methane hydrate was formed in two moist sands and a sand/silt mixture under a confining stress in an X-ray-transparent pressure vessel. Three initial water saturations were used to form three different methane-hydrate saturations in each medium. X-ray computed tomography (CT) was used to observe location-specific density changes caused by hydrate formation and flowing water. Gas-permeability measurements in each test for the dry, moist, frozen, and hydrate-bearing states are presented. As expected, the effective permeabilities (intrinsic permeability of the medium multiplied by the relative permeability) of the moist sands decreased with increasing moisture content. In a series of tests on a single sample, the effective permeability typically decreased as the pore space became more filled, in the order of dry, moist, frozen, and hydrate-bearing. In each test, water was flowed through the hydrate-bearing medium and we observed the location-specific changes in water saturation using CT scanning. We compared our data to a number of models, and our relative permeability data compare most favorably with models in which hydrate occupies the pore bodies rather than the pore throats. Inverse modeling (using the data collected from the tests) will be performed to extend the relative permeability measurements.

54 ENVIRONMENTAL SCIENCES↗

Heat Exchanger Intensification Through Powder Processing and Enhanced Design (HIPPED)

High intensity, supercritical CO 2 heat exchangers capable of operating at temperatures between 800 and 1100 ˚C and pressures greater than 80 bar are considered a critical component for high efficiency power generation and a range of next-generation industrial processes. A novel heat exchanger concept was proposed in this project. The proposed concept involved a plate-type architecture with three-dimensional fins, called twisted s-shaped fins, that capitalize on additive manufacturing. Four manufacturing processes were studied to realize the complex envisioned design: press and sinter of metallic powders, directed energy deposition, laser powder bed fusion, and a novel powder bed process involving a photoreactive polymer called SEAM (scalable expeditious additive manufacturing), that later was developed at MSU. The team was able to manufacture subscale heat exchangers using laser powder bed fusion (LPBF) and SEAM. The team settled on using SEAM as a final manufacturing approach due to its very low cost. The SEAM-manufactured heat exchanger, however, when tested under pressure, exhibited leaks and the process still requires further development beyond the timeline of the project. To support the heat exchanger design and testing, the team developed a new high temperature flow loop allowing testing under high temperature and pressure. Computational modeling of the heat exchanger was also performed for the twisted s-shaped fins and the computations were validated with experimental data. The new twisted fins resulted in enhanced heat transfer and reduced pressure drop. To further minimize pressure drop in the plate heat exchanger, the team also developed a simplified model for flow maldistribution in the manifolds, providing a new tool for designers that eliminates the need for complex CFD calculations. A technoeconomic analysis was also developed to contrast SEAM with LPBF, this tool indicated that SEAM is several times less costly and offer significant promises as a rapid low cost additive manufacturing process for metallic systems.

30 DIRECT ENERGY CONVERSION↗

Supercritical CO2 studies: micro-channel heat transfer for reactor heat exchangers & cycle design

An experimental facility was built to perform heat transfer and pressure drop measurements in supercritical carbon dioxide. Inlet temperatures ranged from 30-125 degress C with mass velocities ranging from 118-1050 kg/m 2 s and system pressures of 7.5-10.2 MPa. Tests were performed in horizontal, upward, and downward flow conditions to test the influence of buoyance foreces on the heat transfer. The majority of experiments were performed in the cooling mode, where the fluid decreases in temperature over the test section length.

Corradini, Michael↗

Design and testing of a sensitive heat-flow calorimeter for measuring radioactive waste in 55-gallon (US) drums - 15334

A sensitive large volume calorimeter for measuring the thermal power generated by the radioactive decay of heat producing materials in 55-gallon drums has been developed and tested. The technology is applicable to the measurement of all radionuclides that decay by alpha or beta decay such as waste or product material containing plutonium, tritium and americium. It is also relevant to the measurement of drums where gamma rays from radioactive decay are captured locally in attenuating materials and the resulting rate of thermal energy deposition (sample thermal power) is of sufficient magnitude for a calorimetry measurement. The initial application of the drum calorimeter is for measuring and characterizing plutonium-bearing waste drums. The calorimeter design has optimised the two characteristics of high thermal sensitivity and reduced measurement times. In order to achieve these characteristics for large volume drums, the heat-flow method of operation was chosen in a single measurement chamber configuration. Using a drum-lifting device, the waste drum is positioned on a sliding platform and subsequently moved by the operator inside an octagonal inner chamber, which acts as the heat sink. The heat-sink chamber has significant thermal inertia and remains effectively at a constant temperature throughout the duration of a drum measurement. The octagonal inner measurement chamber is constructed inside a multi-layer external thermal enclosure, which provides both thermal insulation and significant thermal inertia. The external thermal enclosure isolates the measurement process from the effects of changes in the external ambient temperature. During a measurement, heat flows from the drum being measured to the heat sink. This heat-flow is measured by a series of thermopile sensor assemblies, which are positioned between the waste drum and the heat sink. A high sensitivity of greater than 200 μV/mW (microvolts per milliwatt) has been achieved using multiple close-coupled thermopile sensors in each assembly. Reduced measurement times are achieved by positioning the thermopile sensor assemblies close to the drum surface in order to reduce the thermal transport delay. The instrument incorporates a calibrated precision power supply, which requires annual recalibration and is traceable to national standards. It is used to power a calibration heater that has been built into a calibration and test drum. The calibration and test drum is used both to calibrate the instrument and provide periodic confirmation of correct operation. Measurements of calorimeter performance are reported for a range of drum thermal powers. Long-term temperature drift measurements are used to provide estimates of the minimum detectable drum thermal power and hence the minimum detectable activity for both plutonium and tritium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oil Filled Flow Shield Performance Evaluation

When hydrophones are used to monitor underwater sound in areas with currents, like rivers or tidal channels, flow noise caused by turbulent flow past a hydrophone can mask low frequency acoustic signals of interest. Flow shields can reduce the impacts of flow noise on hydrophone data. A prior study conducted by PNNL compared three flow shield designs and determined that an oil-filled urethane shield performed better than other designs and was likely sufficiently robust for long-duration marine deployments. However, that study did not assess the high frequency performance of the oil-filled flow shield or conduct long-duration field testing. Further, the prototype flow shield was difficult to assemble. This report details the results of design refinement and testing to address these gaps. Design refinements resulted in a straightforward and repeatable assembly method. Field testing indicated that the flow shields reduce flow noise by over 20 dB below 50 Hz at flow speeds greater than 0.5 m/s and are proven to survive deployments more than 6 months long. Calibration of the same hydrophone with and without a flow shield installed indicated that the shields attenuate propagating sound by no more than 2 dB at frequencies below 30 kHz.

42 ENGINEERING↗

Propagating neutronic uncertainties for FFTF LOFWOS Test #13

The safety evaluation conducted for licensing a Sodium-cooled Fast Reactor (SFR) may require modeling transients with best-estimate calculation tools that must first be validated against real-world measurements. To provide the community with a valuable benchmarking opportunity for validating SFR analysis tools and methods, the International Atomic Energy Agency (IAEA) initiated a coordinated research project (CRP) in 2018 for the analysis of the Fast Flux Test Facility (FFTF) Loss of Flow Without Scram (LOFWOS) Test #13. The impact of nuclear data uncertainties on neutronics parameters was previously investigated based on the COMMARA-2.0 covariance matrix. Since the transient simulation results are very sensitive to certain reactivity coefficients, it was decided to employ rigorous uncertainty propagation methods to quantify the impact of nuclear data uncertainties on the best-estimate predication of FFTF LOFWOS Test #13. The DAKOTA code is used to propagate neutronic uncertainties through SAS4A/SASSYS-1 transient simulations, while taking into account spatial and reaction-wise correlations within these uncertainties. This study shows that the remaining discrepancies observed between the Argonne National Laboratory (ANL) best-estimate results and the experimental measurements can be partly explained by the uncertainty associated with Gas Expansion Module (GEM) worth, which contributes the majority of the overall nuclear data uncertainty on the output from the FFTF LOFWOS Test #13 transient simulation. This study also confirmed the importance of including spatial and reaction-wise correlations of nuclear data uncertainties on feedback coefficients in the uncertainty propagation to avoid under-estimating their impact during the transient simulations.

42 ENGINEERING↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Benchmarking FFTF LOFWOS Test# 13 using SAM code: Baseline model development and uncertainty quantification

The development and deployment of advanced reactors, such as the sodium-cooled fast reactor (SFR), relies on sophisticated modeling tools to ensure the safety of the design under various transients. The predictive capability of these advanced modeling tools requires validation to garner trust in supporting the licensing of the advanced reactors. For this reason, the International Atomic Energy Agency (IAEA) initiated a coordinated research project (CRP) in 2018 for the analysis of the Fast Flux Test Facility (FFTF) Loss of Flow Without Scram (LOFWOS) Test #13.In this study, we present and discuss the benchmarking efforts of the modern system code SAM on the FFTF LOFWOS Test #13. Further, the SAM baseline model was developed according to the benchmark specification, which included a detailed core model with reactivity feedback. Generally, good agreement was observed between the baseline results and benchmark measurements; however, discrepancies persisted, particularly in predicted fuel assembly coolant outlet temperatures. Utilizing the baseline model, uncertainty quantification (UQ) and sensitivity analysis (SA) were conducted with the assistance of various statistical learning and machine learning methods, including kernel density estimation, Gaussian processes, and Sobol indices. Following the baseline model prediction and UQ and SA results, we discuss the reasons for the simulation discrepancies and propose further improvements to the model. This benchmarking effort adheres to the best-estimate plus uncertainty approach and can serve as a valuable example for supporting risk-informed licensing of advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sampling Point Compliance Tests for 325 Building at Set-Back Flow Conditions

The stack sampling system at the 325 Building (Radiochemical Processing Laboratory [RPL]) was constructed to comply with the American National Standards Institute’s (ANSI’s) Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities (ANSI N13.1-1969). This standard provided prescriptive criteria for the location of radionuclide air-sampling systems. In 1999, the standard was revised (Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities [ANSI/Health Physics Society [HPS] 13.1-1999]) to provide performance-based criteria for the location of sampling systems. Testing was conducted for the 325 Building stack to determine whether the sampling system would meet the updated criteria for uniform air velocity and contaminant concentration in the revised ANSI/HPS 13.1-1999 standard under normal operating conditions (Smith et al. 2010). Measurement results were within criteria for all tests. Additional testing and modeling was performed to determine whether the sampling system would meet criteria under set-back flow conditions. This included measurements taken from a scale model with one-third of the exhaust flow and computer modeling of the system with two-thirds of the exhaust flow. This report documents the results of the set-back flow condition measurements and modeling. Tests performed included flow angularity, uniformity of velocity, gas concentration, and particle concentration across the duct at the sampling location. Results are within ANSI/HPS 13.1-1999 criteria for all tests. These tests are applicable for the 325 Building stack under set-back exhaust flow operating conditions (980 - 45,400 cubic feet per minute [cfm]) with one fan running. The modeling results show that criteria are met for all tests using a two-fan configuration exhaust (flow modeled at 104,000 cfm). Combined with the results from the earlier normal operating conditions, the ANSI/HPS 13.1-1999 criteria for all tests are met for all configurations: one, two, or three fans (normal).

air sampling↗

Define and Quantify the Physics of Air Flow, Pressure Drop and Aerosol Collection in Nuclear Grade HEPA Filters

Objective: Develop a set of peer-review and verified analytical methods to adjust HEPA filter performance to different flow rates, temperatures and altitudes. Experimental testing will measure HEPA filter flow rate, pressure drop and efficiency to verify the analytical approach. Nuclear facilities utilize HEPA (High Efficiency Particulate Air) filters to purify air flow for workspace ventilation. However, the ASME AG-1 technical standard (Code on Nuclear Air and Gas Treatment) does not adequately describe air flow measurement units for HEPA filter systems. Specifically, the AG-1 standard does not differentiate between volumetric air flow in ACFM (actual cubic feet per minute)compared to mass flow measured in SCFM (standard cubic feet per minute). More importantly, the AG-1 standard has an overall deficiency for using HEPA filter devices at different air flow rates, temperatures, and altitudes. Technical Approach: The collection efficiency and pressure drops of 18 different HEPA filters will be measured over a range of flow rates, temperatures and altitudes. The experimental results will be compared to analytical scoping calculations. Three manufacturers have allocated six HEPA filters each for this effort. The 18 filters will be tested at two different flow rates, two different temperatures and two different altitudes. The 36 total tests will be conducted at two different facilities: the ATI Test facilities (Baltimore MD) and the Los Alamos National Laboratory (Los Alamos NM). The Radiation Protection RP-SVS group at Los Alamos has an aerosol wind tunnel that was originally designed to evaluate small air samplers. In 2010, modifications were started to convert the wind tunnel for HEPA filter testing. (Extensive changes were necessary for the required aerosol generators, HEPA test fixtures, temperature control devices and measurement capabilities.) To this date, none of these modification activities have been funded through a specific DOE or NNSA program. This is expected to require six months of time, after receipt of funding. Benefits: US DOE facilities that use HEPA filters will benefit from access to the new operational measurement methods. Uncertainty and guesswork will be removed from HEPA filter operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance of Different “Lab-On-Chip” Geometries for Making Double Emulsions to Form Polystyrene Shells

Fluid properties and the geometry of lab-on-chip (LOC) designs together affect the formation of double emulsions for making inertial confinement fusion targets. Critical fluid properties include the fluids’ velocities and interfacial tension—a coupled effect that is best characterized by the capillary number (Ca)—and the relative volumetric flow rates (φ). The important geometry of the LOC is the orientation of the channels where they intersect (junction) and the spacing between successive junctions. T-junctions and focus-flow devices were tested. The latter geometry of a double cross (focus flow) performed better: single-emulsion droplets were formed over a wide range of fluid parameters (0.03 < φ < 0.17 and 0.0003 < Ca < 0.001) at the first junction, and double emulsions were formed over a more limited range (φ > 0.5 and Ca < 0.4) at the second junction. A LOC design using the focus-flow design formed water–oil–water (W/O/W) double emulsions with the oil phase containing polystyrene. The double emulsions yielded shells with an outer dimension ranging from 2.3±0.07 mm to 4.3±0.23 mm and a wall thickness ranging from 30 μm to 1.6 mm. Thus, the value of the flow-rate ratio at the second junction provided the most-effective parameter for controlling the inner diameter, outer diameter, and wall thickness of the shell.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow and transport in three-dimensional discrete fracture matrix models using mimetic finite difference on a conforming multi-dimensional mesh

Here, we present a comprehensive workflow to simulate single-phase flow and transport in fractured porous media using the discrete fracture matrix approach. The workflow has three primary parts: (1) a method for conforming mesh generation of and around a three-dimensional fracture network, (2) the discretization of the governing equations using a second-order mimetic finite difference method, and (3) implementation of numerical methods for high-performance computing environments. A method to create a conforming Delaunay tetrahedralization of the volume surrounding the fracture network, where the triangular cells of the fracture mesh are faces in the volume mesh, that addresses pathological cases which commonly arise and degrade mesh quality is also provided. Our open-source subsurface simulator uses a hierarchy of process kernels (one kernel per physical process) that allows for both strong and weak coupling of the fracture and matrix domains. We provide verification tests based on analytic solutions for flow and transport, as well as numerical convergence. We also provide multiple expositions of the method in complex fracture networks. In the first example, we demonstrate that the method is robust by considering two scenarios where the fracture network acts as a barrier to flow, as the primary pathway, or offers the same resistance as the surrounding matrix. In the second test, flow and transport through a three-dimensional stochastically generated network containing 257 fractures is presented.

97 MATHEMATICS AND COMPUTING↗