Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “failure modes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Comparison of hand laid-up tape and filament wound composite cylinders and panels with and without impact damage

Experimentally determined axial compressive failure loads, strains and failure modes of composite flat panels and cylinders are presented. A comparison of two types of filament wound flat graphite-epoxy panels indicates that the winding pattern can influence structural response. A comparison of hand laid-up tape and filament wound composite cylinders indicates that fabrication method may not significantly influence the failure mode or average failure strain of thick-walled (radius-to-thickness ratio less than 15) graphite-epoxy cylinders. The interaction of manufacturing-induced features (fiber cross-overs) and low-speed impact damage for graphite-epoxy specimens is also presented. Filament would flat panels with many fiber cross-overs exhibited lower failure strains than filament wound panels without fiber cross-overs for all impact speeds examined. Graphite-thermoplastic cylinders exhibited a significantly different failure mode from the graphite-epoxy cylinders.

Jegley, Dawn C.↗

Independent Orbiter Assessment (IOA): Assessment of the electrical power generation/power reactant storage and distribution subsystem FMEA/CIL

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) is presented. The IOA effort first completed an analysis of the Electrical Power Generation/Power Reactant Storage and Distribution (EPG/PRSD) subsystem hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baselines with proposed Post 51-L updates included. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison are documented for the Orbiter EPG/PRSD hardware. The comparison produced agreement on all but 27 FMEAs and 9 CIL items. The discrepancy between the number of IOA findings and NASA FMEAs can be partially explained by the different approaches used by IOA and NASA to group failure modes together to form one FMEA. Also, several IOA items represented inner tank components and ground operations failure modes which were not in the NASA baseline.

Ames, B. E.↗

HEAF Cable Fragility Testing at the Solar Furnace at the NSTTF

In order to establish a zone of influence (ZOI) due to a high energy arcing fault (HEAF) environment, the fragility of the targets must be determined. The high heat flux/short duration exposure of a HEAF is considerably different than that of a traditional hydrocarbon fire, which previous research has addressed. The previous failure metrics (e.g., internal jacket temperature of a cable exposed to a fire) were based on low heat flux/long duration exposures. Because of this, evaluation of different physics and failure modes was considered to evaluate the fragility of cables exposed to a HEAF. Tests on cable targets were performed at high heat flux/short duration exposures to gain insight on the relevant physics and failure modes. These tests yielded data on several relevant failure modes, including electrical failure and sustained ignition. Additionally, the results indicated a relationship between the total energy of exposure and the damage state of the cable target. This data can be used to inform the fragility of the targets.

42 ENGINEERING↗

Independent Orbiter Assessment (IOA): Analysis of the electrical power distribution and control/remote manipulator system subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the Electrical Power Distribution and Control (EPD and C)/Remote Manipulator System (RMS) hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained in the NASA FMEA/CIL documentation. This report documents the results of the independent analysis of the EPD and C/RMS (both port and starboard) hardware. The EPD and C/RMS subsystem hardware provides the electrical power and power control circuitry required to safely deploy, operate, control, and stow or guillotine and jettison two (one port and one starboard) RMSs. The EPD and C/RMS subsystem is subdivided into the four following functional divisions: Remote Manipulator Arm; Manipulator Deploy Control; Manipulator Latch Control; Manipulator Arm Shoulder Jettison; and Retention Arm Jettison. The IOA analysis process utilized available EPD and C/RMS hardware drawings and schematics for defining hardware assemblies, components, and hardware items. Each level of hardware was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based on the severity of the effect for each failure mode.

Robinson, W. W.↗

Uncertainty quantification for competing failure mechanisms in unidirectionally reinforced carbon–carbon composites

Microstructure-informed finite element models play a key role in the carbon–carbon composite design process. Variability in manufacturing process parameters and experimental limitations introduce model parameter uncertainty. This study quantifies the effect of model parameter uncertainty on transverse tensile fracture behavior and proposes a methodology to predict the failure mode based on competing microscale damage mechanisms. Finite element simulations incorporate fiber–matrix interface debonding with cohesive zones and matrix damage with a smeared crack band approach in a unidirectional carbon–carbon composite. Results from a variance-based global sensitivity analysis identifies interfacial and matrix damage parameters as the primary source of variability in fracture behavior. Sobol’ indices indicate that matrix and cohesive zone strengths contribute 94% of the variance in the effective ultimate stress. A local analysis elucidates the relationship between these constituent strength parameters and failure mode by estimating the probability of cohesive, matrix, and mixed-mode dominated failure. Based on the results for 4000 simulations, 93% exhibit mixed-mode or interfacial dominated failure, which underscores the crucial role of fiber–matrix interface debonding in the transverse tensile failure of carbon–carbon composites. These uncertainty quantification results facilitate more efficient model calibration and provide a framework for microstructure-informed failure predictions in the face of manufacturing-induced uncertainty.

36 MATERIALS SCIENCE↗

Chapter 3: Photovoltaic Module Stability and Reliability

Profits realized from investment in photovoltaic will benefit from decades of reliable operation. Service life prediction through accelerated tests is only possible if indoor tests duplicate power loss and failure modes observed in fielded systems. Therefore, detailing and quantifying power loss and failure modes is imperative. In the first section, we examine recent trends in degradation rates, the gradual power loss observed for different technologies, climates and other significant factors. In the second section, we provide a summary of the most commonly observed failure modes in fielded systems.

14 SOLAR ENERGY↗

Development of the IPRO-zone for fire PSA and its applications

A PSA analyst has been manually determining fire-induced component failure modes and modeling them into the PSA logics. These can be difficult and time-consuming tasks as they need much information and many events are to be modeled. KAERI has been developing the IPRO-ZONE (interface program for constructing zone effect table) to facilitate fire PSA works for identifying and modeling fire-induced component failure modes, and to construct a one top fire event PSA model. With the output of the IPRO-ZONE, the AIMS-PSA, and internal event one top PSA model, one top fire events PSA model is automatically constructed. The outputs of the IPRO-ZONE include information on fire zones/fire scenarios, fire propagation areas, equipment failure modes affected by a fire, internal PSA basic events corresponding to fire-induced equipment failure modes, and fire events to be modeled. This paper introduces the IPRO-ZONE, and its application results to fire PSA of Ulchin Unit 3 and SMART(System-integrated Modular Advanced Reactor). (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Independent Orbiter Assessment (IOA): FMEA/CIL assessment

The McDonnell Douglas Astronautics Company (MDAC) was selected to perform an Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL). Direction was given by the Orbiter and GFE Projects Office to perform the hardware analysis and assessment using the instructions and ground rules defined in NSTS 22206. The IOA analysis featured a top-down approach to determine hardware failure modes, criticality, and potential critical items. To preserve independence, the analysis was accomplished without reliance upon the results contained within the NASA and Prime Contractor FMEA/CIL documentation. The assessment process compared the independently derived failure modes and criticality assignments to the proposed NASA post 51-L FMEA/CIL documentation. When possible, assessment issues were discussed and resolved with the NASA subsystem managers. Unresolved issues were elevated to the Orbiter and GFE Projects Office manager, Configuration Control Board (CCB), or Program Requirements Control Board (PRCB) for further resolution. The most important Orbiter assessment finding was the previously unknown stuck autopilot push-button criticality 1/1 failure mode. The worst case effect could cause loss of crew/vehicle when the microwave landing system is not active. It is concluded that NASA and Prime Contractor Post 51-L FMEA/CIL documentation assessed by IOA is believed to be technically accurate and complete. All CIL issues were resolved. No FMEA issues remain that have safety implications. Consideration should be given, however, to upgrading NSTS 22206 with definitive ground rules which more clearly spell out the limits of redundancy.

Hinsdale, L. W.↗

Numerical and experimental evaluation of mechanical performance of the multifunctional energy storage composites

This work presents numerical simulation methods to model the mechanical behavior of the multifunctional energy storage composites (MESCs), which consist of a stack of multiple thin battery layers reinforced with through-the-hole polymer rivets and embedded inside carbon fiber composite laminates. MESC has been demonstrated through earlier experiments on its exceptional behavior as a structural element as well as a battery. However, the inherent complex infrastructure of the MESC design has created significant challenges in simulation and modeling. A novel homogenization technique was adopted to characterize the multi-layer properties of battery material using physics-based constitutive equations combined with nonlinear deformation theories to handle the interface between the battery layers. Second, mechanical damage and failure modes among battery materials, polymer reinforcements, and carbon fiber-polymer interfaces were characterized through appropriate models and experiments. The model of MESCs has been implemented in a commercial finite element code in ABAQUS. A comparison of structural response and failure modes from numerical simulations and experimental tests are presented. The results of the study showed that the predictions of elastic and damage responses of MESCs at various loading conditions agreed well with the experimental data. © 2021

Materials Science↗

Status of Understanding for Bearing Materials

The structural materials and potential failure modes for high technology aircraft gas turbine bearings are reviewed. Among the failure modes discussed for iron-base through-hardened bearing materials are fatigue, surface distress, and corrosion. It is shown that the sub-surface initiated rolling-contact fatigue failure mode is reasonably well understood and in most cases can be controlled by proper material selection and design. Current bearing materials provide long life and high reliability in existing applications. A new generation of materials are being developed which will provide improved fracture toughness, better corrosion resistance, and a further extension of bearing fatigue life. Bearing problems due to surface distress, caused by a variety of surface and near surface anomalies, are less well understood. This area will require the implementation of an interdisciplinary effort to improve the level of understanding of metallic surface-lubricant reactions and interactions.

E N Bamberger↗

Independent Orbiter Assessment (IOA): FMEA/CIL assessment

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. Direction was given by the Orbiter and GFE Projects Office to perform the hardware analysis and assessment using the instructions and ground rules defined in NSTS 22206. The IOA analysis features a top-down approach to determine hardware failure modes, criticality, and potential critical items. To preserve independence, the anlaysis was accomplished without reliance upon the results contained within the NASA and prime contractor FMEA/CIL documentation. The assessment process compares the independently derived failure modes and criticality assignments to the proposed NASA Post 51-L FMEA/CIL documentation. When possible, assessment issues are discussed and resolved with the NASA subsystem managers. The assessment results for each subsystem are summarized. The most important Orbiter assessment finding was the previously unknown stuck autopilot push-button criticality 1/1 failure mode, having a worst case effect of loss of crew/vehicle when a microwave landing system is not active.

Saiidi, Mo J.↗

FMEA on the superconducting torus for the Jefferson Lab 12 GeV accelerator upgrade

As part of the Jefferson Lab 12GeV accelerator upgrade project, Hall B requires two conduction cooled superconducting magnets. One is a magnet system consisting of six superconducting trapezoidal racetrack-type coils assembled in a toroidal configuration and the second is an actively shielded solenoidal magnet system consisting of 5 coils. Both magnets are to be wound with Superconducting Super Collider-36 NbTi strand Rutherford cable soldered into a copper channel. This paper describes the various failure modes in torus magnet along with the failure modes that could be experienced by the torus and its interaction with the solenoid which is located in close proximity.

43 PARTICLE ACCELERATORS↗

SU-F-T-248: FMEA Risk Analysis Implementation (AAPM TG-100) in Total Skin Electron Irradiation Technique

Purpose: Total Skin Electron Irradiation (TSEI) is a radiotherapy treatment which involves irradiating the entire body surface as homogeneously as possible. It is composed of an extensive multi-step technique in which quality management requires high consumption of resources and a fluid communication between the involved staff, necessary to improve the safety of treatment. The TG-100 proposes a new perspective of quality management in radiotherapy, presenting a systematic method of risk analysis throughout the global flow of the stages through the patient. The purpose of this work has been to apply TG-100 approach to the TSEI procedure in our institution. Methods: A multidisciplinary team specifically targeting TSEI procedure was formed, that met regularly and jointly developed the process map (PM), following TG-100 guidelines of the AAPM. This PM is a visual representation of the temporal flow of steps through the patient since start until the end of his stay in the radiotherapy service. Results: This is the first stage of the full risk analysis, which is being carried out in the center. The PM provides an overview of the process and facilitates the understanding of the team members who will participate in the subsequent analysis. Currently, the team is implementing the analysis of failure modes and effects (FMEA). The failure modes of each of the steps have been identified and assessors are assigning a value of severity (S), frequency of occurrence (O) and lack of detection (D) individually. To our knowledge, this is the first PM made for the TSEI. The developed PM can be useful for those centers that intend to implement the TSEI technique. Conclusion: The PM of TSEI technique has been established, as the first stage of full risk analysis, performed in a reference center in this treatment.

60 APPLIED LIFE SCIENCES↗

Weighting and Bayes Nets for Rollup of Surveillance Metrics

The LANL IKE team proposes that the surveillance metrics for several data stream that are used to detect the same failure mode be weighted. Similarly, the failure mode metrics are weighted to obtain a subsystem metric.

97 MATHEMATICS AND COMPUTING↗

Orbiter subsystem hardware/software interaction analysis. Volume 8: AFT reaction control system, part 2

The orbiter subsystems and interfacing program elements which interact with the orbiter computer flight software are analyzed. The failure modes identified in the subsystem/element failure mode and effects analysis are examined. Potential interaction with the software is examined through an evaluation of the software requirements. The analysis is restricted to flight software requirements and excludes utility/checkout software. The results of the hardware/software interaction analysis for the forward reaction control system are presented.

Becker, D. D.↗

Reusable rocket engine intelligent control system framework design, phase 2

Elements of an advanced functional framework for reusable rocket engine propulsion system control are presented for the Space Shuttle Main Engine (SSME) demonstration case. Functional elements of the baseline functional framework are defined in detail. The SSME failure modes are evaluated and specific failure modes identified for inclusion in the advanced functional framework diagnostic system. Active control of the SSME start transient is investigated, leading to the identification of a promising approach to mitigating start transient excursions. Key elements of the functional framework are simulated and demonstration cases are provided. Finally, the advanced function framework for control of reusable rocket engines is presented.

Nemeth, ED↗

A Quantitative Failure Analysis on Capacity Fade in Rechargeable Lithium Metal Cells

Rechargeable lithium battery (RLB) technology is transforming portable devices, vehicle electrification, and grid modernization. To make RLB durable, reliable and safe, conducting failure mode and effect analysis (FMEA) to identify failure mechanism under the operating conditions is very desirable. However, this ability is often overlooked or even lacking. The failure analysis (FA) is often conducted by laboratory testing and postmortem analysis, and the knowledge typically empirical. Here we present a quantitative approach for FMEA that can reveal how failure modes and effects reduce the capacity of a RLB. This approach is based on the state of the battery for FMEA, contrary to the conventional approach based on operating or testing conditions. The key aspect of this FMEA method is to convert the experimental results to a state-of-charge (SOC)-based analytic methodology. Such a conversion can separate the thermodynamic and kinetic attributes of capacity fade based on compositional correspondence in the electrode, so the loss and the decreased utilization of the active materials can be determined respectively.

25 ENERGY STORAGE↗

TU-FG-201-11: Evaluating the Validity of Prospective Risk Analysis Methods: A Comparison of Traditional FMEA and Modified Healthcare FMEA

Purpose: To examine the ability of traditional Failure mode and effects analysis (FMEA) and a light version of Healthcare FMEA (HFMEA), called Scenario analysis of FMEA (SAFER) by comparing their outputs in terms of the risks identified and their severity rankings. Methods: We applied two prospective methods of the quality management to surface image guided, linac-based radiosurgery (SIG-RS). For the traditional FMEA, decisions on how to improve an operation are based on risk priority number (RPN). RPN is a product of three indices: occurrence, severity and detectability. The SAFER approach; utilized two indices-frequency and severity-which were defined by a multidisciplinary team. A criticality matrix was divided into 4 categories; very low, low, high and very high. For high risk events, an additional evaluation was performed. Based upon the criticality of the process, it was decided if additional safety measures were needed and what they comprise. Results: Two methods were independently compared to determine if the results and rated risks were matching or not. Our results showed an agreement of 67% between FMEA and SAFER approaches for the 15 riskiest SIG-specific failure modes. The main differences between the two approaches were the distribution of the values and the failure modes (No.52, 54, 154) that have high SAFER scores do not necessarily have high FMEA RPN scores. In our results, there were additional risks identified by both methods with little correspondence. In the SAFER, when the risk score is determined, the basis of the established decision tree or the failure mode should be more investigated. Conclusion: The FMEA method takes into account the probability that an error passes without being detected. SAFER is inductive because it requires the identification of the consequences from causes, and semi-quantitative since it allow the prioritization of risks and mitigation measures, and thus is perfectly applicable to clinical parts of radiotherapy.

60 APPLIED LIFE SCIENCES↗