Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Optimized Negative Staining: a High-throughput Protocol for Examining Small and Asymmetric Protein Structure by Electron Microscopy

Structural determination of proteins is rather challenging for proteins with molecular masses between 40 - 200 kDa. Considering that more than half of natural proteins have a molecular mass between 40 - 200 kDa, a robust and high-throughput method with a nanometer resolution capability is needed. Negative staining (NS) electron microscopy (EM) is an easy, rapid, and qualitative approach which has frequently been used in research laboratories to examine protein structure and protein-protein interactions. Unfortunately, conventional NS protocols often generate structural artifacts on proteins, especially with lipoproteins that usually form presenting rouleaux artifacts. By using images of lipoproteins from cryo-electron microscopy (cryo-EM) as a standard, the key parameters in NS specimen preparation conditions were recently screened and reported as the optimized NS protocol (OpNS), a modified conventional NS protocol. Artifacts like rouleaux can be greatly limited by OpNS, additionally providing high contrast along with reasonably high-resolution (near 1 nm) images of small and asymmetric proteins. These high-resolution and high contrast images are even favorable for an individual protein (a single object, no average) 3D reconstruction, such as a 160 kDa antibody, through the method of electron tomography. Moreover, OpNS can be a high-throughput tool to examine hundreds of samples of small proteins. For example, the previously published mechanism of 53 kDa cholesteryl ester transfer protein (CETP) involved the screening and imaging of hundreds of samples. Considering cryo-EM rarely successfully images proteins less than 200 kDa has yet to publish any study involving screening over one hundred sample conditions, it is fair to call OpNS a high-throughput method for studying small proteins. Hopefully the OpNS protocol presented here can be a useful tool to push the boundaries of EM and accelerate EM studies into small protein structure, dynamics and mechanisms.

47 OTHER INSTRUMENTATION↗

Ion-Depleted Microenvironments During Lithium Deposition Revealed by Operando Freezing Cryogenic Electron Microscopy

Local structures and chemistry at active electrochemical interfaces are critical to determining safety, lifetime, and energy density in lithium metal batteries and other devices, but they are challenging to characterize at the nanoscale. We address this issue by developing operando freezing cryogenic electron microscopy (cryo-EM) to preserve battery interfaces in an active state for subsequent high-resolution characterization. We find that ion-depleted microenvironments form locally in the electrolyte adjacent to the lithium deposition interface in lithium metal batteries and are linked to heterogenous growth morphologies. These depleted environments arise locally even under conditions for which ion depletion is not predicted at steady state; this provides a mechanistic explanation for why dangerous lithium morphologies can still propagate in such systems and lead to thermal runaway. Operando freezing cryo-EM thus provides a method to directly visualize nanoscale heterogeneities that arise locally at electrochemical interfaces and play key roles in device failure.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS,E↗

A New Geometric Method Based on Two-Dimensional Transmission Electron Microscopy for Analysis of Interior versus Exterior Pd Loading on Hollow Carbon Nanofibers

Hallow carbon nanofibers (CNFs) are being explored as catalyst supports because of their unique properties; catalytic activities with both interior and exterior metal loadings are being evaluated. Electron tomography (3D transmission electron microscopy, 3D TEM) has been used to estimate internal versus external loading of metal nanoclusters. However, this method is time consuming and requires a specialized TEM. We prepared three hollow CNF supported Pd samples with various Pd localizations, and developed a geometric analysis method based on 2D TEM images to estimate Pd internal versus external loading percentages. Results show the similar localization for the same sample in terms of the number, surface area, and mass of Pd nanoclusters but distinct values for different samples. To test our method, we compare results for one segment of a CNF using both 3D scanning transmission electron microscopy (3D TEM) and our new 2D geometic analysis method. Agreement is within 15.1%. Our results also agree with 3D TEM results from the literature for similarly prepared Pd on CNFs (within 5.6%). Our geometric analysis method is proposed as a more straightforward and fast way to evaluate metal nanocluster localizations on tubular supports.

2D↗

A comparison of carbon impurities in pre- and post-melt uranium Part 1: Scanning electron microscopy analysis

Although C impurities in U have been studied for decades, fundamental questions regarding their incorporation, migration, and overall transformation during metal processing still exist. In two written Parts, we compare the chemical speciation, distribution, crystallography, and morphologies (size, shape, etc.) of carbon-containing impurities in U metal both before and after melting using high resolution analytical electron microscopy (AEM). This first Part demonstrates the variability of carbide inclusions in depleted U (DU) metal with respect to their chemical phases and morphologies as observed by scanning electron microscopy (SEM). Here, a variety of inclusion types, such as the pill-shaped U monocarbide (UC), previously only hypothesized, are summarized. Additionally, delineation between hopper-shaped U carbonitride U(C,N) and dendritic UC inclusions is discussed in relationship to archived literature.

36 MATERIALS SCIENCE↗

Fluctuation cepstral scanning transmission electron microscopy of mixed-phase amorphous materials

Four-dimensional scanning transmission electron microscopy (4D-STEM) is a versatile analytical tool for characterizing materials structural properties. However, extending such analysis to disordered materials is challenging, especially in technologically important samples with mixed ordered and disordered phases. Here, in this work, we present a new 4D-STEM method, called fluctuation cepstral STEM (FC-STEM), based on the fluctuation analysis of cepstral transform of diffraction patterns. The peaks in the associated transformation relate to inter-atomic distances in a thin sample. By varying the real-space range over which fluctuations are calculated, distinct ordered and disordered phases can be mapped in a diffractive image reconstruction. We demonstrate the principles of FC-STEM by characterizing a silicon anode, harvested from a cycled lithium-ion battery. A mixture of amorphous and nanocrystalline silicon, graphitic carbon, and electrolyte by-products is identified and mapped. Comparisons with conventional electron imaging and energy-dispersive X-ray spectroscopy show that FC-STEM is highly effective for the structure determination of mixed-phase amorphous materials.

36 MATERIALS SCIENCE↗

Direct imaging of electron recombination and transport on a semiconductor surface by femtosecond time-resolved photoemission electron microscopy

Much effort has been devoted to the development of techniques to probe carrier dynamics, which govern many semiconductor device characteristics. We report direct imaging of electron dynamics on semiconductor surfaces by time-resolved photoemission electron microscopy using femtosecond laser pulses. The experiments utilized a variable-repetition-rate femtosecond laser system to suppress sample charging problems. The recombination of photogenerated electrons and the lateral motion of the electrons driven by an external electric field on a GaAs surface were visualized. The mobility was estimated from a linear relationship between the drift velocity and the potential gradient.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

1D to 2D Transition in Tellurium Observed by 4D Electron Microscopy

A new microwave-enhanced synthesis method for the production of tellurium nanostructures is reported here—with control over products from the 1D regime (sub-5 nm diameter nanowires), to nanoribbons, to the 2D tellurene regime—along with a new methodology for local statistical quantification of the crystallographic parameters of these materials at the nanometer scale. Using a direct electron detector and image-corrected microscope, large and robust 4D scanning transmission electron microscopy datasets for accurate structural analysis are obtained. These datasets allow the adaptation of quantitative techniques originally developed for X-ray diffraction (XRD) refinement analyses to transmission electron microscopy, enabling the first demonstration of sub-picometer accuracy lattice parameter extraction while also obtaining both the size of the coherent crystallite domains and the nanostrain, which is observed to decrease as nanowires transition to tellurene. This new local analysis is commensurate with global powder XRD results, indicating the robustness of both the new synthesis approach and new structural analysis methodology for future scalable production of 2D tellurene and characterization of nanomaterials.

2D materials↗

High-resolution electron microscopy characterization of 2H and 9R variant in the ferritic steels containing copper

Ferritic steels containing copper have been studied as model systems for cluster/precipitate formation in reactor pressure vessel steels. The samples were aged at 400 deg. C for 2000 h and subsequently analyzed using high-resolution electron microscopy. Direct evidence was found that, besides the 9R structure occurring, there exist also 2H variant and stacking faults in local regions of the same Cu precipitate. The 2H variant has a hexagonal unit cell with lattice parameters a = b = 0.254 nm and c = 0.417 nm and axial ratio c/a = 1.642. - Research Highlights: {yields}The crystal structures of the copper precipitates in aged reactor pressure vessel model steel were studied by high-resolution electron microscopy (HRTEM). {yields}Besides the 9R structure, there exist also 2H structure and stacking faults within a copper precipitate in aged samples (2000 h at 400 deg. C). {yields}The (001) plane of the 2H structure copper phase is perpendicular to the (010) plane. {yields}The 2H variant has a hexagonal unit cell with lattice parameters a = b = 0.254 nm and c = 0.417 nm and axial ratio c/a = 1.642.

36 MATERIALS SCIENCE↗

Mitigating e-beam-induced hydrocarbon deposition on graphene for atomic-scale scanning transmission electron microscopy studies

Chemical vapor deposition (CVD) grown graphene used in (scanning) transmission electron microscopy [(S)TEM] studies must undergo a careful transfer of the one-atom-thick membrane from the growth surface (typically a Cu foil) to the TEM grid. During this transfer process, the graphene invariably becomes contaminated with foreign materials. This contamination proves to be very problematic in the (S)TEM because often >95% of the graphene is obscured, and imaging of the pristine areas results in e-beam-induced hydrocarbon deposition which further acts to obscure the desired imaging area. In this article, the authors examine two cleaning techniques for CVD grown graphene that mitigate both aspects of the contamination problem: visible contamination covering the graphene, and “invisible” contamination that deposits onto the graphene under e-beam irradiation. Furthermore, the visible contamination may be removed quickly by a rapid thermal annealing to 1200 °C in situ and the invisible e-beam-deposited contamination may be removed through an Ar/O 2 annealing procedure prior to imaging in the (S)TEM.

36 MATERIALS SCIENCE↗

The three-dimensional point spread function of aberration-corrected scanning transmission electron microscopy

Aberration-correction reduces the depth of field in scanning transmission electron microscopy and allows three-dimensional imaging by depth-sectioning. This imaging mode offers the potential for sub- ngstrom lateral resolution and nanometer-scale depth sensitivity. For biological samples, which may be many microns across and where high lateral resolution may not always be needed, optimizing the depth resolution even at the expense of lateral resolution may be desired, aiming to image through thick specimens. Although there has been extensive work examining and optimizing the probe formation in two-dimensions, there is less known about the probe shape along the optical axis. Here we examine the probe shape in three-dimensions in an attempt to better understand the depth-resolution in this mode. We present examples of how aberrations change the probe shape in three-dimensions and demonstrate that off-axial aberrations may need to be considered for focal series of large areas. We show that oversized or annular apertures theoretically improve the vertical resolution for 3D imaging of nanoparticles. When imaging nanoparticles of several nanometer size, the regular STEM can thereby be optimized such that the vertical full width at half maximum approaches that of the aberration corrected STEM with a standard aperture.

99 GENERAL AND MISCELLANEOUS↗

Novel Solid Electrolytes for Li-Ion Batteries: A Perspective from Electron Microscopy Studies

Solid electrolytes can simultaneously overcome two of the most formidable challenges of Li-ion batteries: the severe safety issues and insufficient energy densities. However, before they can be implemented in actual batteries, the ionic conductivity needs to be improved and the interface with electrodes must be optimized. The prerequisite for addressing these issues is a thorough understanding of the material’s behavior at the microscopic and/or the atomic level. (Scanning) transmission electron microscopy is a powerful tool for this purpose, as it can reach an ultrahigh spatial resolution. Here, we review recent electron microscopy investigations on the ion transport behavior in solid electrolytes and their interfaces. Specifically, three aspects will be highlighted: the influence of grain interior atomic configuration on ionic conductivity, the contribution of grain boundaries, and the behavior of solid electrolyte/electrode interfaces. In conclusion, based on this, the perspectives for future research will be discussed.

25 ENERGY STORAGE↗

Electron microscopy of GaAs Structures with InAs and as quantum dots

An electron-microscopy study of GaAs structures, grown by molecular-beam epitaxy, containing two coupled layers of InAs semiconductor quantum dots (QDs) overgrown with a thin buffer GaAs layer and a layer of low-temperature-grown gallium arsenide has been performed. In subsequent annealing, an array of As nanoinclusions (metallic QDs) was formed in the low-temperature-grown GaAs layer. The variation in the microstructure of the samples during temperature and annealing conditions was examined. It was found that, at comparatively low annealing temperatures (400-500 Degree-Sign C), the formation of the As metallic QDs array weakly depends on whether InAs semiconductor QDs are present in the preceding layers or not. In this case, the As metallic QDs have a characteristic size of about 2-3 nm upon annealing at 400 Degree-Sign C and 4-5 nm upon annealing at 500 Degree-Sign C for 15 min. Annealing at 600 Degree-Sign C for 15 min in the growth setup leads to a coarsening of the As metallic QDs to 8-9 nm and to the formation of groups of such QDs in the area of the low-temperature-grown GaAs which is directly adjacent to the buffer layer separating the InAs semiconductor QDs. A more prolonged annealing at an elevated temperature (760 Degree-Sign C) in an atmosphere of hydrogen causes a further increase in the As metallic QDs' size to 20-25 nm and their spatial displacement into the region between the coupled InAs semiconductor QDs.

36 MATERIALS SCIENCE↗

Nanoscale-Femtosecond Imaging of Evanescent Surface Plasmons on Silver Film by Photon-Induced Near-Field Electron Microscopy

Surface plasmons on silver nanostructures have a broad range of tunable resonance properties in visible and near-infrared regimes, which possess wide applications in nanophotonics and optoelectronics. Here, in this study, we use a femtosecond laser to excite surface plasmons on a silver film and trace the subsequent transient dynamics via photon-induced near-field electron microscopy (PINEM). A polarization experiment of PINEM demonstrates a conspicuous polarization dependence of the transient surface plasmon field on the silver film; however, unlike silver nanowires and nanorods, there is no polarization dependence for the PINEM intensity. This compelling finding suggests a thin film platform can be more easily used to identify the temporal and spatial overlaps between the pump laser and probe electron pulses in 4D ultrafast electron microscopy (UEM). Our work illustrates the femtosecond excitation and transient behavior of the surface plasmons on silver film and paves a universal, simple way for identifying the time zero in 4D UEM.

4D electron microscopy↗

Comparative determination of the {alpha}/{beta} phase fraction in {alpha}+{beta}-titanium alloys using X-ray diffraction and electron microscopy

A comparison is made between the measured {alpha}/{beta} phase fractions in Ti-6246 using X-ray diffraction (XRD) and electron microscopy. Image analysis of SEM and TEM images was compared to the phase fraction estimate obtained using electron backscattered diffraction, lab and high-energy synchrotron XRD. There was a good agreement between the electron microscopic and diffraction techniques, provided that the microstructural parameters of grain size and texture are estimated correctly when using quantitative Rietveld refinement.

36 MATERIALS SCIENCE↗

Influence of severe plastic deformation on intermetallic particles in Mg-12 wt.%Zn alloy investigated using transmission electron microscopy

The in-depth microstructural characterization of intermetallic particles in an Mg-12 wt.%Zn binary alloy subjected to a severe plastic deformation is presented. The alloy was processed by four passes via equal channel angular pressing with an applied back pressure at a gradually decreasing temperature and analyzed using transmission electron microscopy techniques to observe the influence of processing on intermetallic particles. The results are compared with the initial state of the material prior to severe plastic deformation. The microstructural evolution of the α-Mg matrix and the Mg{sub 21}Zn{sub 25}, Mg{sub 51}Zn{sub 20} and MgZn{sub 2} was analyzed using bright field imaging, selected area electron diffraction, high-resolution transmission electron microscopy and high-angle annular dark field imaging in scanning mode. The plastic deformation process influenced the α-Mg matrix and each type of intermetallic particle. The α-Mg matrix consisted of two types of areas. The first type of area had a highly deformed structure, and the second type of area had a partially recrystallized structure with an average grain size of approximately 250 nm. The Mg{sub 21}Zn{sub 25} microparticles exhibited distinct forms in the α-Mg matrix that were characterized as a single-crystalline form, a nano-crystalline form and a broken up form. No evidence of Mg{sub 51}Zn{sub 20} nanoparticles within the α-Mg matrix was found in the microstructure, which indicates their dissolution or phase transformation during the deformation process. MgZn{sub 2} nanoparticles exhibited different behavior in both types of α-Mg matrix. Two orientation relationships toward the highly deformed α-Mg matrix were observed; however, there was no relationship toward the partially recrystallized α-Mg matrix. Additionally, the growth of the MgZn{sub 2} nanoparticles was different in the two types of α-Mg matrix. The Mg{sub 51}Zn{sub 20} nanoparticles inside Mg{sub 21}Zn{sub 25} microparticles exhibited a distinct behavior within the single-crystalline or nano-crystalline form of the parent Mg{sub 21}Zn{sub 25} microparticles. The Mg{sub 21}Zn{sub 25} + Mg{sub 51}Zn{sub 20} eutectic compound was confirmed for both forms of the parent Mg{sub 21}Zn{sub 25} microparticles, and the growth of Mg{sub 51}Zn{sub 20} nanoparticles is discussed. - Highlights: •Comprehensive microstructure characterization of Mg-12 wt.%Zn alloy after ECAP-BP •TEM analysis of changes of intermetallic phases caused by SPD •Mg{sub 21}Zn{sub 25} particles exhibit nano-crystalline regions with grain size below 100 nm. •MgZn{sub 2} preserved its orientation relationship toward highly deformed α-Mg after SPD. •Existence of Mg{sub 21}Zn{sub 25} + Mg{sub 51}Zn{sub 20} eutectic remained for each Mg{sub 21}Zn{sub 25} particle form.

36 MATERIALS SCIENCE↗

Reliable strain measurement in transistor arrays by robust scanning transmission electron microscopy

Accurate measurement of the strain field in the channels of transistor arrays is critical for strain engineering in modern electronic devices. We applied atomic-resolution high-angle annular dark-field scanning transmission electron microscopy to quantitative measurement of the strain field in transistor arrays. The quantitative strain profile over 20 transistors was obtained with high reliability and a precision of 0.1%. The strain field was found to form homogeneously in the channels of the transistor arrays. Furthermore, strain relaxation due to the thin foil effect was quantitatively investigated for thicknesses of 35 to 275 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a fast framing detector for electron microscopy

A high frame rate detector system is described that enables fast real-time data analysis of scanning diffraction experiments in scanning transmission electron microscopy (STEM). This is an end-to-end development that encompasses the data producing detector, data transportation, and real-time processing of data. The detector will consist of a central pixel sensor that is surrounded by annular silicon diodes. Both components of the detector system will synchronously capture data at almost 100 kHz frame rate, which produces an approximately 400 Gb/s data stream. Low-level preprocessing will be implemented in firmware before the data is streamed from the National Center for Electron Microscopy (NCEM) to the National Energy Research Scientific Computing Center (NERSC). Live data processing, before it lands on disk, will happen on the Cori supercomputer and aims to present scientists with prompt experimental feedback. This online analysis will provide rough information of the sample that can be utilized for sample alignment, sample monitoring and verification that the experiment is set up correctly. Only a compressed version of the relevant data is then selected for more in-depth processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗