Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Systems and methods of electron beam induced processing

Embodiments of the present disclosure provide for methods and systems for making structures using an electrospray system while under vacuum. In particular, embodiments of the present disclosure provide for methods and systems for ultra-fast growth of high aspect ratio nano/meso/micro-structures with three dimensional topological complexity and control of phase and composition of the structure formed.

Fedorov, Andrei G.↗

Stopping-power enhancement from discrete particle-wake correlations in high-energy-density plasmas

Three-dimensional (3D) simulations of electron beams propagating in high-energy-density plasmas using the quasistatic Particle-in-Cell (PIC) code QuickPIC demonstrate a significant increase in stopping power when beam electrons mutually interact via their wakes. Each beam electron excites a plasma wave wake of wavelength ~ 2 π c / ω p e , where c is the speed of light and ω p e is the background plasma frequency. Here we show that a discrete collection of electrons undergoes a beam-plasma-like instability caused by mutual particle-wake interactions that causes electrons to bunch in the beam, even for beam densities n b for which fluid theory breaks down. This bunching enhances the beam's stopping power, which we call “correlated stopping,” and the effect increases with the “correlation number” N b ≡ n b ( c / ω p e ) 3 . For example, a beam of monoenergetic 9.7 MeV electrons with N b = 1 / 8 , in a cold background plasma with n e = 10 26 cm – 3 (450 g cm – 3 DT), has a stopping power of 2.28 ± 0.04 times the single-electron value, which increases to 1220 ± 5 for N b = 64 . The beam also experiences transverse filamentation, which eventually limits the stopping enhancement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Analysis Support for Acceleratro-based Production of Mo-99

NorthStar Medical Radioisotopes, LLC, is in the process of commissioning a medical isotope production facility, which will use high-power electron accelerators to produce molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons that impinge on the molybdenum target produce bremsstrahlung x-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which creates challenging requirements for target cooling. In the latest concept developed by NorthStar, a stack of target (sintered molybdenum) disks is irradiated from two sides by a 40-MeV electron beam, with a total power of 250 kW (125 kW from each side). The target disks are cooled by pressurized helium gas flowing through channels between the disks. Inconel windows in the target housing form a pressure boundary between the helium within the housing and the evacuated beam tube.

07 ISOTOPE AND RADIATION SOURCES↗

Neutralization of ion beam by electron injection: Accumulation of cold electrons

Ion beam charge neutralization by electron injection is a complex kinetic process. Recent experiments show that the resulting self-potential of the ion beam after neutralization by plasma is much lower than the temperature of plasma electrons [Stepanov et al., Phys. Plasmas 23, 043113 (2016)], indicating that kinetic effects are important and may affect the neutralization of the ion beam. We performed a numerical study of the charge neutralization process of an ion beam making use of a two-dimensional electrostatic particle-in-cell code. The results show that the process of charge neutralization by electron injection is composed of two stages. During the first stage, the self-potential of the beam is higher than the temperature of injected electrons (T e /e) and all injected electrons are captured by the ion beam. During the second stage, hot electrons escape from the ion beam and the beam self-potential (φ) decreases because cold electrons slowly accumulate resulting in the beam self-potential φ to become much lower than Te/e in agreement with previous experimental observations at Princeton Advanced Teststand. We also determined that the resulting φ scales as φ~√T e , in agreement with previous experimental observations from Gabovich's group. In addition, the results show that the transverse position of the electron source has a great impact on ion beam neutralization. A slight shift of the electron source as relevant to the ion thrusters leads to a large increase in the beam self-potential because of an increase in potential energy of injected electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗

3D magnetic imaging using electron vortex beam microscopy

Abstract Electron vortex beams are free-electron waves that carry orbital angular momentum. There has been growing theoretical and experimental interest in the use of electron vortex beams as a tool for the investigation of magnetic materials. However, due to the complex wavefront of the propagating waves, a deeper understanding of the interaction of electron vortex beams and the magnetic sample is needed. Here we calculate the magnetic phase shift that an electron vortex beam obtains upon transmitting through a magnetic sample. We show that this magnetic phase shift is influenced by the out-of-plane magnetization, which is a unique characteristic of incident electron vortex beams and is proportional to their orbital angular momentum. Finally, we develop a phase retrieval methodology to retrieve the out-of-plane component of magnetization. Based on our theory, we discuss suitable experimental conditions that would enable this imaging capability for magnetic materials and further extend to non-magnetic chiral materials.

47 OTHER INSTRUMENTATION↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Design and Prototyping of a Novel Toroid Magnet System for the MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment ?Measurement of Lepton-Lepton Electroweak Reaction? (MOLLER) requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for 3 years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. This system of magnets provides the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This paper presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet in the magnet (TM0) to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 have been fabricated by Everson-Tesla Incorporated, PA (USA). The manuscript presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

Kashy, David↗

Measurement and reduction of Ar metastable densities by nitrogen admixing in electron beam-generated plasmas

Abstract Electron beam (e-beam) generated plasmas are useful for material processing applications such as deposition and etching because the plasmas deliver a large fluence of very low energy of ions to surfaces. Metastable species produced in the beam-region can also transport significant energy to the plasma periphery and surfaces. In this work, we have investigated the spatially resolved density of metastable Ar 1s 5 species produced in an Ar and Ar/N 2 e-beam generated plasma at pressures of 60–67 mTorr using laser-induced fluorescence (LIF). The experiments provide the first direct measure of absolute density and reduction of Ar 1s 5 in an e-beam generated plasma when argon is diluted with nitrogen. These results are consistent with previous predictions of numerical modeling and measurements using optical emission spectroscopy. The present spatially resolved LIF measurements directly quantify the reduction of Ar 1s 5 in the e-beam generated plasma by nitrogen admixing. This reduction was observed in the region of the electron beam and in the plasma periphery, where substrates are usually placed. For example, up to a threefold reduction of the density of Ar 1s 5 was measured when the argon background was diluted with 15.5% nitrogen at pressure of 60 mTorr. Ar 1s 5 reduction is attributed to excitation exchange with nitrogen molecules as well as the cooling of plasma electrons via inelastic collisions with nitrogen molecules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photoinjector generation of high-charge magnetized beams for electron-cooling applications

Electron cooling offers a relatively simple scheme to enable high-luminosity collisions in future electron–ion and hadron colliders. Contemplated TeV-energy hadron colliders require relativistic (sub 100 MeV) high-charge [] electron beams with a specific transverse eigenemittance partition. This paper discusses the generation of high-charge ( nC) 40 MeV electron bunches with eigenemittance partition consistent with requirements associated with electron-cooling option for future electron–ion colliders. The supporting experiment was performed at the FAST facility at Fermilab. The data are compared with numerical simulations and the results discussed in the context of beam requirement for future electron–ion colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoinjector Generation of High-Charge Magnetized Beams for Electron-Cooling Applications

Electron-cooling offers a relatively simple scheme to enable high-luminosity collisions in future electron-ion and hadron colliders. Contemplated TeV-energy hadron colliders require relativistic (sub 100 MeV) high-charge [${\cal O}(\mbox{nC})$] electron beams with a specific transverse eigenemittance partition. This paper discusses the generation of high-charge ($Q\le 3.2$~nC) 40 MeV electron bunches with eigenemittance partition consistent with requirements associated with electron-cooling option for future electron-ion colliders. The supporting experiment was performed at the FAST facility at FermiLab. The data are compared with numerical simulations and the results discussed in the context of beam requirement for future electron-ion colliders.

43 PARTICLE ACCELERATORS↗

Towards Mitigating Electron Beam-Induced Damage in MOFs Using Low Dose Electron Microscopy for In-Situ Room-Temperature Measurements

Metal-Organic Frameworks (MOFs) have emerged as a versatile class of materials with applications in gas storage and separation, catalysis, and drug delivery [1]. Understanding their damage mechanisms in under various environmental conditions is crucial for optimizing performance and stability [2]. This study employs a combination of Length Structural Coherence (LSC) analysis in electron scattering and Electron Energy Loss Spectroscopy (EELS) to elucidate the damage mechanisms in two representative MOFs. MIL101(Fe), and MIL101(Cr). Here, the primary objective is to reveal structural and chemical changes that occur under electron beam irradiation in Scanning Transmission Electron Microscopy (STEM), both in the pristine state and during in-situ CO and CO 2 adsorption. By combining LSC in Radial Distribution Function (RDF) analysis with EELS, comprehensive insights into the nanoscale alterations are obtained and correlated to the electron dose rate.

dos Santos, Gabriel T. [Northwestern University, E↗