Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Li-Metal Anode in Dilute Electrolyte LiFSI/TMP: Electrochemical Stability Using Ab Initio Molecular Dynamics

Ab initio molecular dynamics simulations were performed for Li + conducting electrolytes based on trimethyl phosphates (TMP) and lithium bis(fluorosulfonyl)imide (Li + FSI – ) salt in contact with a Li-metal electrode. We focused on the transient-state behavior at the electrolyte, interfacial electrolyte–Li-metal electrode, and lithium reference electrode–electrolyte–Li-metal electrode to study dynamics and activation energy barriers of the Li + ion, electrochemical and thermal stability of the interface electrode-electrolyte, and potential behavior of the Li-metal electrode, respectively. Our results show that in the most stable state, Li + ions are tetrahedrally coordinated to three TMPs and one FSI – . The inner solvation shell of a Li-ion is composed of three TMP and one FSI – in one contact ion-pair and four TMPs in a solvent-separated ion-pair. On the other hand, Li-ions transport through electrolyte cages takes place when they are coordinated with three or less molecules that could be a combination of TMPs and FSI – . The decomposition pathway of the LiFSI salt when in direct contact with the Li-metal anode starts with defluorination of FSI – , rapidly losing F– to the lithium surface, forming LiF species. The remaining FSO 2 NSO 2 –2 with the addition of 2e – from the Li-metal decomposes into SO 2 –2 and NFSO 2 –2 . SO 2 –2 deposits on the Li-surface and decomposes into Li 2 O and Li 2 S. The remaining NFSO 2 –2 defluorinates, losing F – ion to the lithium surface, resulting in LiF and the remaining NSO 2 –1 deposits on the lithium surface and decomposes in the following picoseconds, forming several binary compounds such as Li 3 N, Li 2 S and Li 2 O. In contrast, when the salt is solvated by the TMP molecules, avoiding a direct contact with the Li metal electrode, only one defluorination occurs, decomposing the FSI – into FSO 2 NSO 2 –2 and a F – . The two anions remain stable as they are solvated by the TMP molecules. Furthermore, we also analyzed the open circuit potential energy (OCPE) of the Li-metal electrode during the SEI formation. OCPE is calculated from the average local potential profile difference within the Li-metal electrode and a pristine Li-crystal reference electrode (LRE). When no SEI is formed, the Li-metal electrode has an average OCPE of +0.36 eV vs LRE. Due to the formation of a SEI, the Li-metal electrode has an average OCPE between -0.07 and -0.21 eV vs LRE. The OCPE of the Li-metal electrode decreases by ~0.42 eV when a SEI is formed.

25 ENERGY STORAGE↗

Reducing sputter induced stress and damage for efficient perovskite/silicon tandem solar cells

Reducing damages caused by sputtering of transparent conductive oxide (TCO) electrodes is critical in achieving highly efficient and stable perovskite/silicon tandem solar cells. Here we study the sputter caused damage to bathocuproine (BCP), which is widely used in highly efficient p-i-n structure single junction perovskite solar cells. While BCP buffer layer protects the underneath layers from damage, itself can be damaged by sputtering of TCOs at a wide range of target-substrate distances, supported by molecular dynamic simulation. More intriguingly, it is observed that TCO easily peeled off after sputtering when the sputtering target is close to substrate. This is ascribed to formation of stress during cooling down process after sputtering due to different thermal expansion coefficients of the layers. Our studies explain why tin oxide (SnO2) made by atomic layer deposition can replace BCP for a much better tandem device performance. SnO2 has high affinity with sputtered TCO electrode to suppress peeling-off issue and has higher bond energy to resist sputter induced damage, thus it allows a wider window of target-substrate distances than BCP during TCO sputtering. Ultimately, we demonstrate an efficient perovskite/silicon monolithic tandem solar cell with efficiency of 26.0% to illustrate the beneficial effects of reduced stress and damage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compressive strength of the plastic-bonded explosive surrogate idoxuridine under quasistatic and dynamic compression

Inert simulant materials, or “mocks”, are often used as surrogates for plastic-bonded explosives (PBX) in non-detonative tests in order to mitigate hazards. Mocks should reproduce as many non-detonative properties of the explosive as possible, including structural behavior in a variety of thermal and mechanical environments. Recently, the molecular crystal idoxuridine (IDOX) has been identified as an ideal mock for the main component in the explosive polymer-matrix composite PBX 9501, and has performed favorably under quasistatic loading conditions. Here, in order to assess robustness over a range of mechanical environments, plastic-bonded IDOX was compression tested from 0.001/s to 2000/s strain rates and compared to PBX 9501 historical data. Plastic-bonded IDOX showed good agreement to PBX 9501 across these strain rates, justifying continued development and production as a mock.

Burch, Alexandra C.↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗

Resilient cooling through geothermal district energy system

Decarbonization and resilience to heat waves have recently become high priorities for building and district energy systems. Geothermal coupled district heating and cooling systems that operate a water loop near ground temperature gain increasing adoption to support decarbonization. In these systems, vapor-compression machines, distributed in the energy transfer stations, lift the temperature up or down to the needs of the particular building. In principle, these systems can provide low-power, free cooling from the geothermal bore field during heat waves when electricity is often scarce. However, the performance of such a resilience operation mode and its implication on the energy system configuration and the sizing of the bore field and HVAC equipment is not yet understood. Consequently, we are assessing their resilience, power use and design implications under a scenario of a heat wave on five working days during which chillers are switched off to reduce electrical consumption. Our analysis is based on high-fidelity, coupled dynamic models of district energy, building-side HVAC and actual control logic, with whole building energy simulation used to assess thermal conditions in a 2004 vintage multi-zone office building in Chicago, IL. The results show that relying only on waterside economizer cooling, the indoor thermal conditions can be maintained in a tolerable range for the majority of the building zones with half the electrical energy compared to standard chiller operation. Thermal comfort in the hottest zones can be further improved by oversizing the cooling coil. However, the waterside economizer has significant implications on the system configuration and sizing: The geothermal bore field needs to be sized about 30% larger than the upper limit of the range observed for conventional geothermal systems. Nevertheless, if a central chiller plant is added, the bore field can be downsized to the typical design range. The latter configuration still allows compressor-less cooling during the heat wave with peak power reduced by 60% compared to the standard design and chiller operation.

15 GEOTHERMAL ENERGY↗

Understanding interfacial crystallization dynamics on carbon fiber reinforced polypropylene composite manufacturing

Reinforcing polymers with discontinuous fibers improves mechanical properties, such as strength and stiffness, and in some cases achieve isotropic properties, rendering them suitable for various engineering applications. Matrix materials are generally highly engineered thermosets (e.g. crosslinked epoxies), bonded to the fiber periphery by proprietary surface and sizing chemistries. Semicrystalline thermoplastic matrices are less utilized due to poor fiber-matrix bonding resulting in inefficient interfacial load-transfer in reinforced composites. However, flexibility with melt-processing or molding conditions can be leveraged to promote non-covalent interfacial bonding between matrix and fiber via crystallization of the matrix onto fiber surface. In the present study, we utilize a co-mingle chopped carbon and isotactic polypropylene fibers to form isotropic composites, tailoring interfacial immobilized matrix or interphase morphology to optimize performance through precise control of thermal processing/molding windows. Calorimetry and optical microscopy were employed to investigate the impact of carbon fiber at various volume fractions (10, 20, and 30 %) on isotactic polypropylene crystallization and mechanical performance. Variations in mechanical properties correspond to the structural evolution of the interfacial region and are correlated to underlying microstructural attributes using wide-angle X-ray scattering, thermal analysis, and low-field nuclear magnetic resonance spectroscopy. These results provide a practical framework for the manufacturing of thermoplastic matrix composites. In conclusion, the results presented provide a guide for the strategic optimization of interphase design, showcasing tailorable tensile strengths which outperform any isotactic polypropylene carbon fiber composites previously reported in literature.

36 MATERIALS SCIENCE↗

Assembling Si 2 BN nanoribbons into a 3D porous structure as a universal anode material for both Li- and Na-ion batteries with high performance

The development of anode materials is critical to the success of sodium ion batteries (SIBs). Because of the size difference between Li and Na, the commercial anode material graphite in Li-ion batteries does not work for Na-ion batteries. Thus, it will be ideal if some universal anode materials could work for both Li- and Na-ion batteries with high performance. Inspired by a recent study on the high performance of a 2D-Si 2 BN sheet as an anode material for Li-ion batteries, we design a three dimensional (3D) porous structure by using the nanoribbons of a Si 2 BN sheet as building blocks. Based on the state-of-the-art ab initio calculations, we find that the resulting 3D porous Si 2 BN structure is stable chemically, dynamically and thermally, exhibiting a high specific capacity of 512.42 (341.61 mA h g -1 ), a low voltage of 0.27 V (0.15 V), a small volume expansion of 2.5% (2.7%), and a low migration energy barrier of 0.44 eV (0.19 eV) for Li- (Na-) ion batteries. Finally, these intriguing features, together with the light mass and rich abundance of Si, B and N, suggest that the 3D porous Si2BN structure is a promising candidate for the anode material of both Li- and Na-ion batteries.

36 MATERIALS SCIENCE↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Hybridized Discontinuous Galerkin Methods for Computational Fluid Dynamics

Hybridizable Discontinuous Galerkin (HDG) methods hold promise for any applications with significant advection character, including thermal hydraulics in light water reactors and advanced reactor concepts and fluid models of plasmas in magnetic confinement fusion. Its features include natural upwinding, local element conservation, and extensibility to arbitrarily high order accuracy. In the last fiscal year we have implemented HDG in the Multiphysics Object-Oriented Simulation Environment (MOOSE). We developed a first-of-its-kind automatic static condensation system in MOOSE’s underlying finite element library libMesh which can condense out arbitrarily many internal variables. Finally, we developed the first preconditioner for HDG discretizations of the Navier-Stokes equations which shows robust performance across a wide range of problem sizes and Reynolds numbers. This preconditioner yields solution times that are equivalent to the fastest developed for industry standard finite volume methods. Moreover, the arbitrarily high-order nature of HDG makes it a prime candidate for acceleration via graphical processing units (GPUs). We believe these developments will hold significant importance for future DOE Nuclear Energy (NE) and Fusion Energy Science (FES) programs.

97 MATHEMATICS AND COMPUTING↗

Feasibility and Prospects of the High Resolution Rapid Refresh Model For Dynamic Line Rating

The ampacity of transmission lines is defined as the maximum amount of current the conductor can safely carry. It is necessary for transmission line operators to apply ampacity limits due to the thermal properties of the conductor. Dynamic Line Rating (DLR) is a technology and technique that uses the environmental conditions or a set of the conditions to calculate the ampacity of the conductor. The way the DLR is calculated has depended upon some amount of physical technology to implement the solution. The High Resolution Rapid Refresh (HRRR) Model is an atmospheric model that may provide enough resolution to perform dynamic line rating without any hardware at all. The objective is to use this model to perform Dynamic Line Rating. This will solve two of the most pervasive problems in Dynamic Line Rating, how to instrument a transmission line hundreds of miles long and then how to predict near future ampacity sufficient for transmission operators to effectively use, This technique will use the Idaho National Laboratory site as the test location for analysis. The High Resolution Rapid Refresh model is a reliable, freely available, and well-maintained weather forecasting model for the entire United States of America. The model provides enough special resolution that additional local weather monitoring devices at location are not necessary to conduct dynamic line rating. The HRRR ratings are lower on average than the locally measured ratings which allows for an additional margin of safety. The adoption of using purely digital methods for dynamic line rating could allow for wide scale adoption of the technology with very little overhead expenditure of implementation.

17 WIND ENERGY↗

Application of Dynamical System Scaling for Accelerated Fuel Qualification Efforts

There are considerable ongoing research and testing campaigns to qualify new fuel designs such as metallic fuels for advanced reactor designs and the Accident Tolerant Fuel (ATF) campaign for light water reactors (LWR). The typical research and development lifecycle needed to qualify a nuclear fuel design, under ideal conditions, can take up to 20-25 years which limits the ability for new fuels to make fast deployments into commercial, test, and research reactors. While there are several efforts to accelerate nuclear fuel qualification through advanced modeling coupled with state-of-the-art experiments, there is not yet a framework to methodically quantify and rank distortions occurring in experimental test specimens needed to validate nuclear fuel performance codes. This study uses the Dynamical System Scaling (DSS) methodology to quantify transient scaling distortions that occur over experiment and simulated transients. DSS analysis metrics provide a researcher with several tools and information embedded within test data to identify dominant phenomena, associated timescales, and quantify a transient?s overall dynamic distortion. This is demonstrated with separate analyses of the SETH-C and CHF-SERTTA thermal-hydraulic experiments in the TREAT facility at Idaho National Laboratory. The outcome of this work is a scaling and data analysis approach to account for the influence a scaled fuel test specimen?s geometric and temporal distortions have on its ability to be representative of the full-scale design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Spray and Combustion Models for Simulating Dilute Combustion in a Direct-Injection Spark-Ignition Engine

Dilute combustion in spark-ignition engines has the potential to improve thermal efficiency by mitigating knock and by reducing throttling and wall heat losses. However, ignition and combustion processes can become unstable for dilute operation due to a lowered laminar flame speed, resulting in excessive cycle-to-cycle variability (CCV) of the combustion process. To compensate for the slower combustion in less reactive mixtures, a modified intake port geometry can be employed to generate a strong tumble flow in the cylinder and elevate turbulence levels around the spark plug, thereby promoting a faster transition to turbulent deflagration. Consequently, optimizing combustion chamber geometry and operating strategy is crucial to maximizing the benefits of using dilute combustion with enhanced in-cylinder turbulence across a wide range of operating conditions. Computational fluid dynamics (CFD) simulations can be utilized for virtual engine optimization tasks, but this would require the models to be truly predictive regarding the impact of changes to the engine design and operational parameters.In this study, multicycle large-eddy simulations (LES) are performed for a direct-injection spark-ignition engine to investigate the model performance in predicting engine combustion characteristics with respect to changes in the intake configuration. A tumble plate that blocks the lower part of the intake port inlet is used to vary the tumble. A set of CFD models that have been recently developed are employed, which takes into account the drag of nonspherical droplets, flash-boiling behavior of liquid sprays, spray-wall interaction, surrogate formulation of a research-grade E10 gasoline, and fast chemical kinetic solvers. Simulation results are compared to experimental engine data in terms of cylinder pressure, apparent heat release rate, mass fraction burned timing, and flame images. It is found that LES employing the state-of-the-art CFD models are capable of properly predicting the spray processes and reproducing the measured mean cylinder pressure for the case with the tumble plate. On the other hand, the LES over-predicts the combustion rate during the early combustion stage and under-estimates the CCV, and these discrepancies become larger when the tumble plate is removed.

computational fluid dynamics simulation↗

Conceptual core design of the molten metal fueled microreactor with self-regulating capability

The microreactor concept has received significant attention in the United States for its lower capital investment, siting flexibility and high mobility. A microreactor aims to provide reliable electricity in remote communities, mining areas, or isolated islands, which will save the high fuel transportation cost. Thus, minimizing the staff level for operating and maintaining a microreactor is desirable. The objective of the study is to design a self-regulated Molten Metal fueled microReactor core (MMR) and to demonstrate the self-regulating capability of the MMR core. The control of the reactor is solely relying on reactivity feedbacks from fuel temperature perturbation. Molten UMn (liquid form at the temperature over 720°C) was utilized as the fuel material in MMR due to the larger thermal expansion coefficient compared to the conventional solid fuel. The MMR core has a fast neutron spectrum, which corresponds to a small burnup reactivity swing. The core design parameters were selected based on DAKOTA, REBUS, and ANLHTP calculations. The MMR is designed to run for 10 years at a power level of 15 MWth. Furthermore, no refueling is needed during the reactor lifetime. The system dynamic analyses were performed, and it was found that the reactor can be self-regulating within a temperature range of 800 ± 80°C for a loss of heat sink transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Valorization of consolidated bioprocessing residues for bioplastics

This study demonstrates an organic solvent-free processing strategy to valorize consolidated bioprocessing (CBP) residues, from switchgrass and poplar biomass, into functional poly(butylene succinate) (PBS)-based biocomposites using high-shear homogenization (HSH). HSH transformed the switchgrass and poplar CBP residues (CBP-R) into fine, uniformly distributed particles and microfibers. The composites of PBS with homogenized switchgrass residues (H-CBP-R-SG) or homogenized poplar residues (H-CBP-R-P) at a 70/30 weight ratio exhibited improved processability and mechanical integrity, with the Young's modulus for the PBS/H-CBP-R-SG and PBS/H-CBP-R-P nearly doubling to 0.66 ± 0.07 GPa and 0.65 ± 0.04 GPa, respectively, compared to neat PBS (0.36 ± 0.02 GPa). Dynamic Mechanical Analysis (DMA) reveals a significant suppression of the tan δ peak magnitude, indicating that HSH-mediated physical activation facilitates stress transfer in composites typical of covalent chemical grafting systems. While the transition to a stiffness-dominated profile reduces ductility, the resulting composites exhibit the dimensional stability and resistance to thermal warping required for high-fidelity FDM 3D printing and injection molding. Beyond material performance, comprehensive techno-economic analysis (TEA) and life cycle assessment (LCA) confirmed that diverting CBP residues into composite products can improve the economic viability of the biorefinery without substantially increasing biorefinery global warming potential (GWP). At a 30 wt% blend ratio, incorporating residuals into PBS yielded a minimum selling price for the composite of $\$4.07$ per kg compared to the conventional bioplastic price of $\$5.00$ per kg. This approach aligns with circular bioeconomy principles by converting waste streams into value-added products. Furthermore, this innovative strategy addresses key challenges in bioplastic development, including cost, compatibility, and performance, while simultaneously advancing waste minimization strategies for sustainable manufacturing systems.

09 BIOMASS FUELS↗

Sodium Exposure Tests of A709 Steel (FY2020 Progress Report)

Sodium exposure tests were conducted on the first commercial heat, H58776 of A709 steel. Six different processing and heat treatment conditions were investigated, including three processing conditions, namely, Argon-Oxygen-Decarburization (AOD), Electro-slag Remelting (ESR), and Electro-slag Remelting with subsequent homogenization (HOMO), and two heat treatment conditions, i.e. solution annealing at 1100°C (SA1100°C) or 1150°C (SA1150°C). Specimens of AOD-SA1100°C, AOD-SA1150°C, ESR-SA1100°C, ESR-SA1150°C, HOMO-SA1100°C, and HOMO-SA1150°C were tested in sodium at 650°C and for times up to 10,152 h. Specimens in the AOD-SA1100°C and AOD-SA1150°C conditions were also tested in sodium at 550 and 600°C. Parallel thermal aging experiments were carried out for comparison with sodium exposure tests to separate the thermal and sodium effects. It was found that A709 H58776 generally showed a weight loss after sodium exposures at 650°C except a few data points of the ESR-SA1100°C specimens. The corrosion rate showed large variations in the initial stage and decreased with increasing exposure time. Long-term exposure tests are needed to determine its steady-state corrosion rate. The AOD-SA1100°C and HOMO-SA1100°C specimens showed similar tensile responses after thermal or sodium exposures at 650°C. The yield stress increased, the ultimate tensile strength decreased, and the uniform and total elongations were reduced after thermal or sodium exposures. A longer exposure time had a minimal effect on the tensile strength but further reduced the tensile ductility. The sodium-exposed specimens had higher tensile strength than the thermally-aged specimens. In contrast, the ESR-SA1100°C specimens showed an increase in the yield stress and the ultimate tensile strength after thermal or sodium exposures at 650°C and ~10,000 h. The AOD-SA1150°C and ESR-SA1150°C specimens showed similar tensile behavior after thermal or sodium exposures at 650°C.Thermal or sodium exposures at 650°C increased the yield stress, decreased the ultimate tensile strength, and reduced uniform and total elongations. There were minimal differences in tensile properties between the sodium-exposed and thermally-aged specimens after an ~3000 h exposure. After an exposure for ~10,000 h the sodium-exposed specimens showed higher yield stress and ultimate tensile strength and lower uniform and total elongations than the thermally-aged specimens. For the HOMO-SA1150°C specimens, thermal or sodium exposures at 650°C significantly increased the yield stress but had a minimal effect on the ultimate tensile strength. Both uniform and total elongations were significantly reduced at an exposure time of ~3,000 h, and they were further reduced after an exposure of ~10,000 h. The sodium-exposed specimens had lower tensile ductility than the thermally-aged specimens. Before exposure, the stress-strain curves of the specimens in all six processing-heat treatment conditions showed serrations indicating the dynamic aging effect at 650°C. Thermal aging or sodium exposures at 650°C after ~10,000 h completely removed the serrations of the flow curves in A709 H58776, indicating strong precipitation during thermal or sodium exposures. Longer-term sodium exposure tests are needed to determine the steady-state corrosion rates in sodium for A709 H58776 and fully understand the influence of sodium exposures on its mechanical performance.

36 MATERIALS SCIENCE↗