At least 433 records · Page 24

Design of a Doppler reflectometer for KSTAR

A Doppler reflectometer has been designed to measure the poloidal propagation velocity on the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. It has the operating frequency range of V-band (50-75 GHz) and the monostatic antenna configuration with extraordinary mode (X-mode). The single sideband modulation with an intermediate frequency of 50 MHz is used for the heterodyne measurement with the 200 MHz in-phase and quadrature (I/Q) phase detector. The corrugated conical horn antenna is used to approximate the Gaussian beam propagation and it is installed together with the oversized rectangular waveguides in the vacuum vessel. The first commissioning test of the Doppler reflectometer system on the KSTAR tokamak is planned in the 2014 KSTAR experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D camera assisted fully automated calibration of scanning laser Doppler vibrometers

Scanning laser Doppler vibrometers (LDV) are used to measure full-field vibration shapes of products and structures. In most commercially available scanning laser Doppler vibrometer systems the user manually draws a grid of measurement locations on a 2D camera image of the product. The determination of the correct physical measurement locations can be a time consuming and diffcult task. In this paper we present a new methodology for product testing and quality control that integrates 3D imaging techniques with vibration measurements. This procedure allows to test prototypes in a shorter period because physical measurements locations will be located automatically. The proposed methodology uses a 3D time-of-flight camera to measure the location and orientation of the test-object. The 3D image of the time-of-flight camera is then matched with the 3D-CAD model of the object in which measurement locations are pre-defined. A time of flight camera operates strictly in the near infrared spectrum. To improve the signal to noise ratio in the time-of-flight measurement, a time-of-flight camera uses a band filter. As a result of this filter, the laser spot of most laser vibrometers is invisible in the time-of-flight image. Therefore a 2D RGB-camera is used to find the laser-spot of the vibrometer. The laser spot is matched to the 3D image obtained by the time-of-flight camera. Next an automatic calibration procedure is used to aim the laser at the (pre)defined locations. Another benefit from this methodology is that it incorporates automatic mapping between a CAD model and the vibration measurements. This mapping can be used to visualize measurements directly on a 3D CAD model. Secondly the orientation of the CAD model is known with respect to the laser beam. This information can be used to find the direction of the measured vibration relatively to the surface of the object. With this direction, the vibration measurements can be compared more precisely with numerical experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In vivo visualization method by absolute blood flow velocity based on speckle and fringe pattern using two-beam multipoint laser Doppler velocimetry

Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensional space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvements to the Ion Doppler Spectrometer Diagnostic on the HIT-SI Experiments

An Ion Doppler Spectrometer diagnostic system measuring impurity ion temperature and velocity on the HIT-SI and HIT-SI3 spheromak devices has been improved with higher spatiotemporal resolution and lower error than previously described devices. Hardware and software improvements to the established technique have resulted in a record 6.9 µs temporal and <=2.8 cm spatial resolution in the midplane of each device. These allow C III and O II flow, displacement, and temperature profiles to be simultaneously observed. With 72 fused-silica fiber channels in two independent bundles, and an f/8.5 Czerny-Turner spectrometer coupled to video camera, frame-rates of up to ten times the imposed magnetic perturbation frequency of 14.5 kHz were achieved in HIT-SI, viewing the upper 1/2 of the midplane. In HIT-SI3 frame-rates of up to eight times the perturbation frequency were achieved viewing both halves of the midplane. Biorthogonal Decomposition is used as a novel filtering tool, reducing uncertainty in ion temperature from <=13 to <=5 eV (with an instrument temperature of 8-16 eV), and uncertainty in velocity from <=2 to <=1 km/s. Doppler shift and broadening is calculated via the Levenberg-Marquart algorithm, after which errors in velocity and temperature are uniquely specified. Axisymmetric temperature profiles on HIT-SI3 for C III peaked near the inboard current separatrix at approximately 40 eV are observed. Axisymmetric plasma displacement profiles have been measured on HIT-SI3, peaking at approximately 6 cm at the outboard separatrix. Both profiles agree with the upper half of the midplane observable by HIT-SI. With its complete midplane view, HIT-SI3 has unambiguously extracted axisymmetric, toroidal current dependent rotation of up to 3 km/s. Analysis of the temporal phase of the displacement uncovers a coherent structure, locked to the applied perturbation. Previously described diagnostic systems could not achieve such results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme measurements with Photonic Doppler Velocimetry (PDV)

Photonic Doppler Velocimetry (PDV) is a fiber-based diagnostic for the extreme conditions created by high-speed impact, explosive detonation, electrical pulsed power, and intense laser ablation. PDV is a conceptually simple application of the optical Doppler effect, but measurements above 1 km/s only became practical at the beginning of the twenty-first century. In this work, I discuss the evolution of PDV, its operational details, practical analysis, and outstanding challenges.

47 OTHER INSTRUMENTATION↗

Time-lens photon Doppler velocimetry (TL-PDV)

Here, we describe a time lens (TL) to expand the dynamic range of photon Doppler velocimetry (PDV) systems. The principle and preliminary design of a TL-PDV system are explained and shown to be feasible through simulations. In a PDV system, an interferometer is used for measuring frequency shifts due to the Doppler effect from the target motion. However, the sampling rate of the electronics could limit the velocity range of a PDV system. A four-wave-mixing (FWM) TL applies a quadratic temporal phase to an optical signal within a nonlinear FWM medium (such as an integrated photonic waveguide or a highly nonlinear optical fiber). By spectrally isolating the mixing product, termed the idler, and with appropriate lengths of dispersion prior to and after this FWM TL, a temporally magnified version of the input signal is generated. Therefore, the frequency shifts of PDV can be “slowed down” with the magnification factor M of the TL. M = 1 corresponds to a regular PDV system without a TL. M = 10 has been shown to be feasible for a TL-PDV system. The use of this effect for PDV can expand the velocity measurement range and allow for the use of lower bandwidth electronics. TL-PDV will open up new avenues for various dynamic material experiments.

47 OTHER INSTRUMENTATION↗

Quantum interference of biphotons with a Doppler frequency shift

We report a theoretical study of transformation of a biphoton state of light under Bragg diffraction on a travelling sound wave in an acousto-optic modulator (AOM). It is shown that the diffraction of AOM biphotons emitted during the collinear parametric scattering of light leads to a shift of the carrier frequency of a biphoton wave packet, which exceeds twice the Doppler frequency shift for the classical field. A method is proposed for measuring the Doppler frequency shift of a biphoton, which is based on interference between independent biphotons. (quantum interferometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ON THE DOPPLER SHIFT AND ASYMMETRY OF STOKES PROFILES OF PHOTOSPHERIC Fe I AND CHROMOSPHERIC Mg I LINES

We analyzed the full Stokes spectra using simultaneous measurements of the photospheric (Fe I 630.15 and 630.25 nm) and chromospheric (Mg I b {sub 2} 517.27 nm) lines. The data were obtained with the High Altitude Observatory/National Solar Observatory (HAO/NSO) advanced Stokes polarimeter, about a near disk center sunspot region, NOAA AR 9661. We compare the characteristics of the Stokes profiles in terms of Doppler shifts and asymmetries among the three spectral lines, helping us to better understand the chromospheric lines and the magnetic and flow fields in different magnetic regions. The main results are: (1) for the penumbral area observed by the photospheric Fe I lines, Doppler velocities derived from Stokes I ({nu} {sub i}) are very close to those derived from linear polarization profiles ({nu}{sub lp}) but significantly different from those derived from Stokes V profiles ({nu}{sub zc}), thus providing direct and strong evidence that the penumbral Evershed flows are magnetized and mainly carried by the horizontal magnetic component; (2) the rudimentary inverse Evershed effect observed by the Mg I b {sub 2} line provides qualitative evidence on its formation height that is around or just above the temperature minimum region; (3) {nu}{sub zc} and {nu}{sub lp} in the penumbrae and {nu}{sub zc} in the pores generally approach their {nu} {sub i} observed by the chromospheric Mg I line, which is not the case for the photospheric Fe I lines; (4) the outer penumbrae and pores show similar Stokes V asymmetry behavior that tend to change from positive values in the photosphere (Fe I lines) to negative values in the low chromosphere (Mg I line); (5) the Stokes V profiles in plage regions are highly asymmetric in the photosphere and more symmetric in the low chromosphere; and (6) strong redshifts and large asymmetries are found around the magnetic polarity inversion line within the common penumbra of the {delta} spot. We offer explanations or speculations to the observed discrepancies between the photospheric and chromospheric lines in terms of the three-dimensional structure of the magnetic and velocity fields. This study thus emphasizes the importance of spectropolarimetry using chromospheric lines.

79 ASTRONOMY AND ASTROPHYSICS↗

SOLAR MERIDIONAL CIRCULATION FROM DOPPLER SHIFTS OF THE Fe I LINE AT 5250 A AS MEASURED BY THE 150-FOOT SOLAR TOWER TELESCOPE AT THE MT. WILSON OBSERVATORY

Doppler shifts of the Fe I spectral line at 5250 A from the full solar disk obtained over the period 1986 to 2009 are analyzed to determine the circulation velocity of the solar surface along meridional planes. Simultaneous measurements of the Zeeman splitting of this line are used to obtain measurements of the solar magnetic field that are used to select low field points and impose corrections for the magnetically induced Doppler shift. The data utilized is from a new reduction that preserves the full spatial resolution of the original observations so that the circulation flow can be followed to latitudes of 80{sup 0} N/S. The deduced meridional flow is shown to differ from the circulation velocities derived from magnetic pattern movements. A reversed circulation pattern is seen in polar regions for three successive solar minima. A surge in circulation velocity at low latitudes is seen during the rising phases of cycles 22 and 23.

79 ASTRONOMY AND ASTROPHYSICS↗

A high-frequency Doppler feature in the power spectra of simulated GRMHD black hole accretion disks

Black hole binaries exhibit a wide range of variability phenomena, from large-scale state changes to broadband noise and quasi-periodic oscillations, but the physical nature of much of this variability is poorly understood. We examine the variability properties of three GRMHD simulations of thin accretion disks around black holes of varying spin, producing light curves and power spectra as would be seen by observers. We find that the simulated power spectra show a broad feature at high frequency, which increases in amplitude with the inclination of the observer. We show that this high-frequency feature is a product of the Doppler effect and that its location is a function of the mass and spin of the black hole. This Doppler feature demonstrates that power spectral properties of the accretion disk can be tied to, and potentially used to determine, physical properties of the black hole.

79 ASTRONOMY AND ASTROPHYSICS↗

A misaligned prograde orbit for Kepler-13 Ab via doppler tomography

Transiting planets around rapidly rotating stars are not amenable to precise radial velocity observations, such as are used for planet candidate validation, as they have wide, rotationally broadened stellar lines. Such planets can, however, be observed using Doppler tomography, wherein stellar absorption line profile distortions during transit are spectroscopically resolved. This allows the validation of transiting planet candidates and the measurement of the stellar spin-planetary orbit (mis)alignment, which is an important statistical probe of planetary migration processes. We present Doppler tomographic observations that provide direct confirmation of the hot Jupiter Kepler-13 Ab and also show that the planet has a prograde, misaligned orbit with λ = 58.°6 ± 2.°0. Our measured value of the spin-orbit misalignment is in significant disagreement with the value of λ = 23° ± 4° previously measured by Barnes et al. (2011) from the gravity-darkened Kepler light curve. We also place an upper limit of 0.75 M{sub ☉} (95% confidence) on the mass of Kepler-13 C, the spectroscopic companion to Kepler-13 B, which is the proper-motion companion of the planet host star Kepler-13 A.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-range Doppler lidar measurements of wind turbine wakes and their interaction with turbulent atmospheric boundary-layer flow at Perdigao 2017

As part of the Perdigão 2017 campaign, vertical RHI (range-height indicator) scans with long-range pulsed Doppler wind lidars were performed aligned with the main wind direction and a wind turbine (WT) located on a mountain ridge. The measurements are used to not only retrieve flow velocities, but also their variance and - by using the turbulent broadening of the Doppler spectrum - also turbulent kinetic energy (TKE) dissipation rate. The study shows that turbulence in the WT wake is dependent on the turbulence of the inflow, but also on atmospheric stability. In stable atmospheric conditions, wakes could be analyzed up to five rotor diameters downstream (D) and showed the maximum turbulence in the wake at 2-3 D, whereas in unstable conditions, the maximum was found at 2 D and the wake could not be detected further than 3 D. A clear dependency of wake turbulence enhancement on inflow turbulence intensity is found, which levels out to no further enhancement at turbulence intensities of 30%.

17 WIND ENERGY↗

Comparison of horizontal wind speed and direction measurements from dual-Doppler radar and profiling lidars

Dual-Doppler radar is a relatively new technology in the wind energy community and thus not yet studied vastly. This paper aims to compare horizontal wind speed and direction data retrieved from dual-Doppler radar and profiling lidars within the American WAKE experimeNt (AWAKEN) to investigate the influence of measurement height, wind direction and speed on the comparison. The 10-min averaged data show a better agreement of the measurements for higher altitudes, especially at faster wind speeds. For the wind direction, two sectors of larger differences in the measurements were detected: around 270° transient winds occur with a higher frequency than in other sectors. To explain the different measurement values in the wind direction sector around 90°, further studies, e.g. on the influence of atmospheric stability, are necessary.

17 WIND ENERGY↗

Cavity ring-down spectroscopy measurements of sub-Doppler hyperfine structure

Frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) was used to measure magnetic dipole transitions in the b {sup 1{Sigma}}{sub g}{sup +} (leftarrow) X {sup 3{Sigma}}{sub g}{sup -}(0,0) band of O{sub 2}. The {sup 17}O-containing isotopologues show unresolved hyperfine structure due to magnetic hyperfine splitting in the ground state. The sensitivity and stability of FS-CRDS allow for quantitative sub-Doppler measurements of the hyperfine constants, even when the hyperfine splittings are much smaller than the Doppler width. Unlike saturation spectroscopy, this linear absorption technique can be applied to weak transitions and employed to quantitatively measure intensities and line shapes. This method may be an attractive approach for measuring unresolved hyperfine structure in excited electronic states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Prospects for Doppler cooling of three-electronic-level molecules

Analogous to the extension of laser cooling techniques from two-level to three-level atoms, Doppler cooling of molecules with an intermediate electronic state is considered. In particular, we use a rate-equation approach to simulate cooling of SiO{sup +}, in which population buildup in the intermediate state is prevented by its short lifetime. We determine that Doppler cooling of SiO{sup +} can be accomplished without optically repumping from the intermediate state, at the cost of causing undesirable parity flips and rotational diffusion. Since the necessary repumping would require a large number of continuous-wave lasers, optical pulse shaping of a femtosecond laser is proposed as an attractive alternative. Other candidate three-electron-level molecules are also discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Doppler cooling with coherent trains of laser pulses and a tunable velocity comb

We explore the possibility of decelerating and Doppler cooling an ensemble of two-level atoms by a coherent train of short, nonoverlapping laser pulses. We derive analytical expressions for mechanical force exerted by the train. In frequency space the force pattern reflects the underlying frequency comb structure. The pattern depends strongly on the ratio of the atomic lifetime to the repetition time between the pulses and pulse area. For example, in the limit of short lifetimes, the frequency-space peaks of the optical force wash out. We propose to tune the carrier-envelope offset frequency to follow the Doppler-shifted detuning as atoms decelerate; this leads to compression of atomic velocity distribution about comb teeth and results in a ''velocity comb''--a series of narrow equidistant peaks in the velocity space.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of Doppler-free electromagnetically induced transparency in atoms selected optically with specific velocity

We observed an electromagnetically induced transparency signal in a four-level system with optically selected rubidium atoms at specific velocities in a room-temperature vaporized cell. Since the atoms behave like cold atoms in the selected atomic view, the observed signals coincide with a trapped atomic system. According to this result, we can observe Doppler-free signals, which correspond from 1.2 to 1.0 K in a Doppler-broadened medium. And the selected atoms have velocity components of {+-}(131 {+-} 3) MHz per wave number. Our experimental results can provide insight for research in cold media.

74 ATOMIC AND MOLECULAR PHYSICS↗

Doppler- and recoil-free laser excitation of Rydberg states via three-photon transitions

Three-photon laser excitation of Rydberg states by three different laser beams can be arranged in a starlike geometry that simultaneously eliminates the recoil effect and Doppler broadening. Our analytical and numerical calculations for a particular laser excitation scheme 5S{sub 1/2}{yields}5P{sub 3/2}{yields}6S{sub 1/2}{yields}nP in Rb atoms have shown that, compared to the one- and two-photon laser excitation, this approach provides much narrower linewidth and longer coherence time for both cold atom samples and hot vapors, if the intermediate one-photon resonances of the three-photon transition are detuned by more than respective single-photon Doppler widths. This method can be used to improve fidelity of Rydberg quantum gates and precision of spectroscopic measurements in Rydberg atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗