Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

431 records · Page 24

Financing Microgrids in the Federal Sector

Recent high-impact events such as hurricanes and wildfires highlight the need for energy system resilience. One potential impact of these events is the loss of utility grid power to federal sites, negatively affecting the ability to carry out their missions. Depending on the need to sustain critical functions, it may be important to continue operations during an outage of the electric grid, or at least have power restored quickly after the event. One approach to addressing this need is through a microgrid. Microgrids can provide a more reliable solution than the traditional approach of using a backup generator at individual buildings. A microgrid can enhance a site’s electrical power system during normal operations, as well as provide reliable backup power to critical loads when electric utility power is interrupted. Many times, certain components of a microgrid (and potentially the entire system) can be justified economically and paid for out of energy savings or avoided costs. In cases where savings can cover the project costs, one of several privately financed procurement mechanisms may be used to implement the project. Procurement options available to all federal agencies include utility energy services contracts (UESC), energy savings performance contracts (ESPC), and utility services contracts (USC); other mechanisms such as a power purchase agreement (PPA), enhanced use lease (EUL), and utility privatization (UP) may also be useful to agencies that have the authority to use them. Implementing a microgrid in a comprehensive effort that also includes energy efficiency can provide an important savings component, while reducing power requirements for critical loads, thus reducing the cost of the microgrid and associated distributed energy resources (DER). However, it can be difficult to achieve enough savings and avoided costs to cover the entire microgrid system, so leveraging these avoided costs in combination with appropriated funds may be necessary to implement the full project. When a site is deciding if a microgrid is the best solution, activities early in the process include identifying critical loads and existing DERs, conversations with the local electric utility, and implementation options that work best for the agency and site. This paper explores procurement options and agreements that may be useful to federal agencies interested in implementing microgrids at their sites. Microgrid complexities, implementation considerations, and suggestions to get started are also discussed. This information will be most useful to agencies when they are exploring electric energy system resilience options and/or considering different procurement options to meet their needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modification and analysis of context-specific genome-scale metabolic models: methane-utilizing microbial chassis as a case study

ABSTRACT Context-specific genome-scale model (CS-GSM) reconstruction is becoming an efficient strategy for integrating and cross-comparing experimental multi-scale data to explore the relationship between cellular genotypes, facilitating fundamental or applied research discoveries. However, the application of CS modeling for non-conventional microbes is still challenging. Here, we present a graphical user interface that integrates COBRApy, EscherPy, and RIPTiDe, Python-based tools within the BioUML platform, and streamlines the reconstruction and interrogation of the CS genome-scale metabolic frameworks via Jupyter Notebook. The approach was tested using -omics data collected for Methylotuvimicrobium alcaliphilum 20Z R , a prominent microbial chassis for methane capturing and valorization. We optimized the previously reconstructed whole genome-scale metabolic network by adjusting the flux distribution using gene expression data. The outputs of the automatically reconstructed CS metabolic network were comparable to manually optimized i IA409 models for Ca-growth conditions. However, the CS model questions the reversibility of the phosphoketolase pathway and suggests higher flux via primary oxidation pathways. The model also highlighted unresolved carbon partitioning between assimilatory and catabolic pathways at the formaldehyde-formate node. Only a very few genes and only one enzyme with a predicted function in C1 metabolism, a homolog of the formaldehyde oxidation enzyme ( fae1-2 ), showed a significant change in expression in La-growth conditions. The CS-GSM predictions agreed with the experimental measurements under the assumption that the Fae1-2 is a part of the tetrahydrofolate-linked pathway. The cellular roles of the tungsten (W)-dependent formate dehydrogenase ( fdhAB ) and fae homologs ( fae1-2 and fae3 ) were investigated via mutagenesis. The phenotype of the f dhAB mutant followed the model prediction. Furthermore, a more significant reduction of the biomass yield was observed during growth in La-supplemented media, confirming a higher flux through formate. M. alcaliphilum 20Z R mutants lacking fae1-2 did not display any significant defects in methane or methanol-dependent growth. However, contrary to fae1, the fae1-2 homolog failed to restore the formaldehyde-activating enzyme function in complementation tests. Overall, the presented data suggest that the developed computational workflow supports the reconstruction and validation of CS-GSM networks of non-model microbes. IMPORTANCE The interrogation of various types of data is a routine strategy to explore the relationship between genotype and phenotype. An efficient approach for integrating and cross-comparing experimental multi-scale data in the context of whole-genome-based metabolic network reconstruction becomes a powerful tool that facilitates fundamental and applied research discoveries. The present study describes the reconstruction of a context-specific (CS) model for the methane-utilizing bacterium, Methylotuvimicrobium alcaliphilum 20Z R . M. alcaliphilum 20Z R is becoming an attractive microbial platform for the production of biofuels, chemicals, pharmaceuticals, and bio-sorbents for capturing atmospheric methane. We demonstrate that this pipeline can help reconstruct metabolic models that are similar to manually curated networks. Furthermore, the model is able to highlight previously overlooked pathways, thus advancing fundamental knowledge of non-model microbial systems or promoting their development toward biotechnological or environmental implementations.

Kulyashov, M. A.↗

Identifying recharge processes into a vast “fossil” aquifer based on dynamic groundwater 81 Kr age evolution

Water in deep aquifers in arid regions is often considered to be "fossil" when modern recharge rates are negligible relative to the reservoir capacity. Over the past five decades, the Nubian Sandstone Aquifer (NSA) in the arid region of the Sinai Peninsula (Egypt) and the Negev Desert (Israel) has been considered to contain fossil water based on 14 C dating, which revealed 14 C ages of about 30 kyr over most of the aquifer. However, this relatively homogeneous age distribution contradicts the expected increase in groundwater age in the direction of decreasing piezometric head along the flow trajectories. Here, dating results with the longer-lived 81 Kr radioisotope (t 1/2 = 229 ± 11 kyr) are presented, highlighting a wide age range of 40 kyr to 630 kyr in the confined sections of the aquifer, all with very low 14 C activity (<1 pmC). Elevated 81Kr and 14 C activities were only observed within or close to the system's recharge areas. These findings support a new perception of groundwater replenishment during different epochs from the early mid- Pleistocene to the Holocene. By tracking the downstream age evolution, rejuvenation was identified in places where the confinement had been breached. At other locations, the existence of an older groundwater body contributing to the aquifer was detected by means of strongly depleted 81 Kr activity. High spatial heterogeneity in groundwater ages close to the discharge zone of the system is attributed to pronounced age stratification with depth. Calculated ages in the more isolated sections of the system were used to assess regional flow velocity, hydraulic conductivity, and their agreement with present recharge rates. We conclude that regional aquifers in which low 14 C activity suggests homogeneous ancient groundwater age should be reevaluated with 81Kr. With an effective age range beyond one million years, this may enable the restoration of recharge history and provide crucial information for the management of groundwater resources.

54 ENVIRONMENTAL SCIENCES↗

Laboratory Investigation of Ice Formation and Elimination in the Induction System of a Large Twin-engine Cargo Aircraft

The icing characteristics, the de-icing rate with hot air, and the effect of impact ice on fuel metering and mixture distribution have been determined in a laboratory investigation of that part of the engine induction system consisting of a three-barrel injection-type carburetor and a supercharger housing with spinner-type fuel injection from an 18-cylinder radial engine used on a large twin-engine cargo airplane. The induction system remained ice-free at carburetor-air temperatures above 36 F regardless of the moisture content of the air. Between carburetor-air temperatures of 32 F and 36 F with humidity ratios in excess of saturation, serious throttling ice formed in the carburetor because of expansion cooling of the air; at carburetor-air temperatures below 32 F with humidity ratios in excess of saturation, serious impact-ice formations occurred, Spinner-type fuel injection at the entrance to the supercharger and heating of the supercharger-inlet elbow and the guide vanes by the warn oil in the rear engine housing are design features that proved effective in eliminating fuel-evaporation icing and minimized the formation of throttling ice below the carburetor. Air-flow recovery time with fixed throttle was rapidly reduced as the inlet -air wet -bulb temperature was increased to 55 F; further temperature increase produced negligible improvement in recovery time. Larger ice formations and lower icing temperatures increased the time required to restore proper air flow at a given wet-bulb temperature. Impact-ice formations on the entrance screen and the top of the carburetor reduced the over-all fuel-air ratio and increased the spread between the over-all ratio and the fuel-air ratio of the individual cylinders. The normal spread of fuel-air ratio was increased from 0.020 to 0.028 when the left quarter of the entrance screen was blocked in a manner simulating the blocking resulting from ice formations released from upstream duct walls during hot-air de-icing.

ICE PREVENTION - AIR HEATING↗

Analysis of Loss-of-Offsite-Power Events: 2021 Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2021, while the most recent 15-year data (i.e., from 2007–2021) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather-related. These categories (and the All-LOOPs group which contains all LOOPs without regarding of the four categories) could be further grouped by whether a LOOP event occurred during critical operation, during shutdown operation, or during all operations. The following decreasing trends in the LOOP occurrence rates were identified for the most recent 10-year period (2012–2021): All-LOOPs during critical operation, switchyard-centered LOOPs during critical operation, and grid-related LOOPs during critical operation. Adverse trends in LOOP durations continue for switchyard-centered LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during shutdown operation for the 1997–2021 period. Statistical tests show the LOOP counts for the period of 2007–2021 are not uniformly distributed across the 12 months, and variation among the months exists for grid-related LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during critical operation. The engineering analysis of LOOP data showed for the period of 2007–2021, the equipment failure events were dominated by failures of relay and other; human errors have been less frequent and occurred primarily in maintenance and switching; and weather were dominated by tornadoes then by lightning and hurricane. Weather was the cause for 45% of LOOPs for the last fifteen years (2007– 2021) but only for 20% of LOOPs for the previous 20 years (1987–2006) .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Applications of Measuring and Valuing Resilience in Energy Systems

The electricity sector is vulnerable to numerous hazards that are being exacerbated by climate change, which can cause an increase in the hazards' frequency and intensity. Consumers, system regulators, system operators, and communities are now preparing to mitigate the increased risks posed by climate change. New York State's energy infrastructure resilience can be increased with targeted investments including but not limited to installing emergency backup systems, integrating microgrid solutions, weatherizing buildings, increasing energy efficiency, adding redundancy, investing in restoration and recovery, and hardening critical components. Such investments can reduce the likelihood, impact, and consequences of disruptive events but can also increase capital and operating costs. A barrier to prioritizing investments in resilience is that there is no widely established method for quantifying and assigning the benefits of resilience investments across various stakeholders. Decision-makers need better information detailing the value of resilience improvements. Developing methods to quantify, value, and price resilience helps meet resilience needs in an effective manner that also supports broader societal welfare. This report lays out considerations for quantifying and valuing resilience, discusses the current state of resilience valuation tools, and provides case studies of resilience projects that demonstrate how resilience attributes could be measured while highlighting broader, project-specific challenges to increasing resilience. Further, we present insights into methods and challenges to measuring, valuing, and enacting resilience investments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Space and Time Dynamics of Transpiration in the East River Watershed: Biotic and Abiotic Controls

Alpine forests have important impacts on water resources by affecting how much of the precipitation that falls on a watershed is routed to streamflow or returned to the atmosphere as transpiration – so-called “green water”. In many of the high-altitude watersheds that supply critical water resources to the western US, it remains a challenge to predict how much water forests will utilize limiting the ability to predict both short and long term information on downstream water resources. The uncertainty emerges because transpiration varies between tree species, across landscapes and over time in ways that cannot readily be predicted from physically-based models for evaporation. In this project, we utilized a technique called sap flux to measure the rate of water use for three common species of fir, spruce and aspen distributed across a hillslope in the East River Watershed from 2019-2021. We also made ~weekly measurements of the concentration of stable isotopic tracers in transpiration to understand not only how much water was being used but whether it originated from summer rain or snowmelt. Firstly, our results show that the species tend to use similar amounts of total water but they achieve this similar cumulative water flux both by using water at different times of the year and by using different water sources. This shows the importance of including species-level information into models used to make seasonal streamflow predictions. Secondly, our results show that trees lower on the hillslope use older waters all through the summer whereas trees higher on the hillslope rely more heavily on recent summer rain. This means trees lower on the hillslope are less sensitive to year-to-year changes in summer climate. Lastly, we found that sites with dense forest stands displayed the largest amounts of year-to-year changes in transpiration and thus these high localized spots in the watershed are the primary drivers of changes in “green water” use. The results provide an unprecedented spatial and temporal picture of forest water use that confirms a number of fundamental hypotheses on hillslope ecohydrology that had not previously been tested against observations. Predictions of streamflow that will benefit from this work are highly valuable for agriculture management, flood control and ecological restoration efforts.

54 ENVIRONMENTAL SCIENCES↗

Regional Power System Black Start with Run-of-river Hydropower Plant and Battery Energy Storage

Battery energy storage systems (BESSs) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various critical services to the power grid. This paper presents the real-world experience of using a megawatt-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to restore a regional power system. To demonstrate this, we carry out power-hardware-in-the-loop experiments integrating an actual GFL- or GFM-controlled BESS and a load bank. Both the simulation and experimental results presented in this paper show the different roles of GFL- or GFM-controlled BESS in power system black starts. The results provide further insight for system operators on how GFL- or GFM-controlled BESS can enhance grid stability and how an ROR hydropower plant can be converted into a black-start-capable unit with the support of a small-capacity BESS. The results show that an ROR hydropower plant combined with a BESS has the potential of becoming one of enabling elements to perform bottom-up black-start schemes as opposed to conventional bottom-down method, thus enhancing the system resiliency and robustness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validating Greater Sage-Grouse Individual-based Model (IBM) Tool (Final Report)

The project focused on validating the previously developed Greater Sage-Grouse Individual-based Model (GrSG IBM; LaGory et al. 2012, 2021). The objective was to transform this predictive, spatially and temporally explicit model into a portable resource to assist siting/resource managers in proactively assessing the cumulative impacts of wind energy development on the greater sage-grouse. Utilizing a bottom-up, individual-based approach, the GrSG IBM accounts for landscape context and species behavior, aiming to reduce uncertainty in estimating development impacts and support ecologically mindful land-based wind energy development. The validation effort covered approximately 6,540 km 2 near the Seven Mile Hill Wind Project in Wyoming. The GrSG IBM tool, built on the NetLogo platform (Tisue and Wilensky 2004), was executed over a 50-year period, with the analysis focusing on years following a 10-year initialization phase. Key results demonstrated the tool’s biological soundness across five key biological metrics: non-chick age class distribution (older than 10 weeks), adult sex ratio, life expectancy, population size, and overall population growth. For instance, the tool estimated that 58.6% of the non-chick population was reproductively immature, while the reference ranges from 51.4% to 57.8% (Patterson 1952, Rogers 1964). Experts confirmed the tool’s estimate was within a reasonable range for the species. The tool estimated average life expectancy of 1.43 years, while the reference ranges from 0.9 years to 1.1 years (Ammann 1957, Hamerstrom 1949). Experts also supported the model’s life-expectancy estimate as ecologically sound for the species in the study area. In terms of population change, the model estimated an annual shift between a 0.6% decline and a 1.0% increase over 50 years. While the reference suggests 2.9% annual decline in range-wide populations (Cortes et al. 2023), that includes many at-risk populations in South Dakota and Washington, for example. Our study area—in the northeastern part of Carbon County and western-edge of Albany County, Wyoming—is one of the remaining greater sage-grouse habitats supporting some of the most stable populations. Experts confirmed that the range of the annual population change spanning from a 0.6% decline to a 1.0% increase estimated by the tool was reasonable for our study area for this reason and confirmed that aligned with population estimates from existing studies on the greater sage-grouse and wind energy development in the study area (LeBeau et al. 2017a, Smith et al. 2024). Furthermore, the project showed that temporally explicit biological metrics generated by the GrSG IBM tool can complement the USGS’ Prioritizing Restoration of Sagebrush Ecosystems Tool (PReSET; Duchardt et al. 2021) by incorporating habitat restoration strategies into seasonal habitat suitability models to visualize population responses over time.

17 WIND ENERGY↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Challenges in Low-Inertia Power-Electronics-Dominated Grids

Here, the low inertia characteristics of the power electronics dominated grid (PEDG) introduces challenges while restoring voltage and frequency to their nominal values. These stability challenges create new cybersecurity vulnerabilities that are not thoroughly discussed in the literature. Cyber events such as false data injection (FDI), denial of service (DoS), man-in-the-middle attacks, stealthy attacks, and advanced persistent threats target PEDG to disrupt grid stability or gain financial benefits. The low inertia of PEDG (< 2s) compared to traditional grids (~10s) exacerbates these vulnerabilities. In response to stealthy attacks on state variables that supervisory layers cannot detect until significant harm occurs, the low inertia characteristics of PEDG offer substantial stealthy attack surfaces. To counteract such threats, PEDG must be equipped with ultra-fast real-time anomaly detection system and trajectory prediction mechanism to achieve effective cyberattack resiliency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lawrence Livermore National Laboratory Environmental Report 2021

The purposes of the Lawrence Livermore National Laboratory Environmental Report 2021 are to record Lawrence Livermore National Laboratory’s (LLNL’s) compliance with environmental standards and requirements, describe LLNL’s environmental protection and remediation programs, and present the results of environmental monitoring at the two LLNL sites—the Livermore Site and Site 300. The report is prepared for the U.S. Department of Energy (DOE) by LLNL’s Environmental Functional Area. Submittal of the report satisfies requirements under DOE Order 231.1B, “Environment, Safety and Health Reporting,” and DOE Order 458.1, “Radiation Protection of the Public and Environment.” The report is distributed electronically and is available at https://saer.llnl.gov/, the website for the LLNL annual environmental report. Previous LLNL annual environmental reports beginning with 1994 are also on the website. Some references in the electronic report text are underlined, which indicates that they are clickable links. Clicking on one of these links will open the related document, data workbook, or website. Sampling location maps throughout this report were created using ArcGIS® software by Esri. The report begins with an executive summary, which provides the purpose of the report and an overview of LLNL’s compliance and monitoring results. The first three chapters provide background information: Chapter 1 is an overview of the location, meteorology, and hydrogeology of the two LLNL sites; Chapter 2 is a summary of LLNL’s compliance with environmental regulations; and Chapter 3 is a description of LLNL’s environmental programs with an emphasis on the Environmental Management System including pollution prevention. The majority of the report covers LLNL’s environmental monitoring programs and monitoring data for 2021: effluent and ambient air monitoring and dose assessment (Chapter 4); waters, including wastewater, storm water runoff, surface water, rain, and groundwater (Chapter 5); and terrestrial, including soil, sediment, vegetation, foodstuff, ambient radiation, and special status wildlife and plants (Chapter 6). The remaining two chapters discuss LLNL’s groundwater remediation program (Chapter 7), and quality assurance for the environmental monitoring programs (Chapter 8). Complete monitoring data, which are summarized in the body of the report, are provided in Appendix A. The report uses Système International units, consistent with the federal Metric Conversion Act of 1975 and Executive Order 12770, “Metric Usage in Federal Government Programs” (1991). For ease of comparison to environmental reports issued prior to 1991, dose values and many radiological measurements are given in both metric and U.S. customary units. A conversion table is provided in the glossary. The report is the responsibility of LLNL’s Environmental Functional Area. Monitoring data were obtained through the combined efforts of the Environmental Functional Area; Environmental Restoration Department; Physical and Life Sciences Environmental Monitoring Radiological Laboratory; and the Radiation Protection Functional Area.

54 ENVIRONMENTAL SCIENCES↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recovery Simulator and Analysis Formulation: Mathematical Framework for Enhanced Resilience and Resource Allocation

This report introduces recovery simulator and analysis (RSA), a framework aimed at enhancing the resilience of electrical grids post-disruption. The RSA model leverages an optimization problem formulation that focuses on maximizing the load served (or optionally customers served) through a coordinated and cooptimized recovery of non-black start generation, transmission lines, feeders and substations subject to labor budget constraints. By integrating advanced linear programming techniques, the simulator selects efficient reocovery pathways, optimizing both short-term and long-term grid recovery strategies. The mathematical framework guides decision-making through a comprehensive evaluation of potential recovery actions, factoring in the trade-offs between labor constraints and load (or optionally customer) restoration efficacy. This enables grid operators to simulate diverse outage scenarios and delineate optimal recovery pathways, thereby prioritizing critical repair tasks and ensuring resource allocation is both economical and effective. The intended use case of RSA is to allow planners to explore many recovery scenarios quickly and determine assets most critical across a wide range of scenarios, and therefore strong candidates for hardening or additional investment. RSA might also be used in an operational setting, following a single event, for exploring efficient recovery pathways.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE↗