Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

Impacts of Distributed Speed Harmonization and Optimal Maneuver Planning on Multi-Lane Roads

A commonly proposed method for improving traffic flow on freeways is speed harmonization. The effectiveness of current speed harmonization approaches, such as variable speed limits, is extremely reliant on human driver compliance. Connected and automated vehicles (CAVs) are expected to come to market within this decade, offering the opportunity to eliminate or reduce the reliance on human compliance. However, extending current roadside infrastructure-based approaches of assigning centrally computed harmonization speeds to individual vehicles is, costly. An alternative approach is to have individual vehicles estimate the traffic state on-board and make distributed decisions to achieve the harmonization goal autonomously. In this work, we present a distributed algorithm for estimating the current average speed of traffic. We couple this with a distributed 2D maneuver planning approach. Then, we study the impact on traffic efficiency in terms of energy consumption and travel time at varying CAV penetration rates.

Goulet, Nathan↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

Estimation of Sea Spray Aerosol Surface Area Over the Southern Ocean Using Scattering Measurements

This study focuses on methods to estimate dry marine aerosol surface area (SA) from bulk optical measurements. Aerosol SA is used in many models' ice nucleating particle (INP) parameterizations, as well as influencing particle light scattering, hygroscopic growth, and reactivity, but direct observations are scarce in the Southern Ocean (SO). Two campaigns jointly conducted in austral summer 2018 provided co-located measurements of aerosol SA from particle size distributions and lidar to evaluate SA estimation methods in this region. Mie theory calculations based on measured size distributions were used to test a proposed approximation for dry aerosol SA, which relies on estimating effective scattering efficiency (Q) as a function of Ångström exponent (å). For distributions with dry å < 1, Q = 2 was found to be a good approximation within ±50%, but for distributions with dry å > 1, an assumption of Q = 3 as in some prior studies underestimates dry aerosol SA by a factor of 2 or more. We propose a new relationship between dry å and Q, which can be used for –0.2 < å < 2, and suggest å = 0.8 as the cutoff between primary and secondary marine aerosol-dominated distributions. Application of a published methodology to retrieve dry marine aerosol SA from lidar extinction profiles overestimated aerosol SA by a factor of 3–5 during these campaigns. Using Microtops aerosol optical thickness measurements, we derive alternative lidar conversion parameters from our observations, applicable to marine aerosol over the SO.

54 ENVIRONMENTAL SCIENCES↗

Characterizing degraded visual environments with scanning lenses to improve contrast recovery

Atmospheric aerosols, such as fog and smoke, degrade optical signals via the scattering and absorption of light, making it difficult to recover information from the surrounding environment. Here, we present a technique that measures the angular distribution of light in scattering environments to help recover these degraded optical signals. This is done by passing a collimated beam through the aerosol environment and collecting the scattered and unscattered light with an f-theta scan lens. The lens transforms the angular distribution of the scattered light into the linear domain, mapping the collected light onto a detector. The measured angular scattering distribution is then used to estimate the point spread function of the environment at an arbitrary stand-off distance. This point spread function can be used to deconvolve images blurred by the aerosol environment in which the angular scattering distribution was initially measured. With this approach, we demonstrate improvements in the effective resolution of deblurred images up to 26% over a 120-cm stand-off distance. Experimentation was performed in the Sandia National Laboratories tabletop fog chamber, a platform that generates aerosol environments analogous to real-world fogs. We intend to leverage this technique in future work to develop a low-SWaP system for the in situ characterization of aerosol environments.

Aerosols↗

CPUC Avoided Transmission and Distribution Cost Study to Support the Avoided Cost Calculator: Avoided Transmission Costs Draft Research Plan

Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) have been contracted by the California Public Utilities Commission (CPUC) Energy Division (ED) to perform a study which explores and selects an improved methodology to estimate avoided electricity transmission and distribution (T&D) infrastructure costs that can be attributed to the presence of distributed energy resources (DERs). PNNL is performing the study for avoided electricity transmission infrastructure costs and LBNL is performing the study for avoided electricity distribution infrastructure costs. This document summarizes CPUC’s research questions related to avoided transmission infrastructure costs and PNNL’s proposed technical approach to answer these questions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Radiation Mapping for an Unmanned Aerial Vehicle: Development and Simulated Testing of Algorithms for Source Mapping and Navigation Path Generation

Image reconstruction algorithms were developed for radiation source mapping and used for generating the search path of a moving radiation detector, such as one onboard an unmanned aerial vehicle. Simulations consisted of first assuming radioactive sources of varying complexity and estimating the radiation fields that would then be produced by that source distribution. Next, the "measurements" that would result from a pair of adjacent spatial locations were computed. A crude estimate of the source distribution likely to have produced such "measurements" was reconstructed based upon the limited measurements. Location of the next "measurement" was then determined as halfway between the location of the estimated source and the current "measurement." With each additional sample, improved source distribution reconstructions were made and used to inform the immediate direction of detector motion. Source reconstruction or mapping was formulated as an inverse problem solved with either maximum a posteriori or least squares (LS) regression deconvolution methods. Different amounts of noise were added to the simulated "measurements," allowing evaluation of the methods' performances as functions of signal-to-noise ratio of the measured map. As expected, methods that promote sparsity were better suited in reconstructing point sources. Reliable prior information of the source distribution also improved the reconstruction results, especially with distributed sources. With a non-negative least square algorithm and the suggested paths it generated, location of sources was successfully estimated to an accuracy of 0.014 m within nine iterations in a single-source scenario and 12 iterations in a two-source scenario, given a 10% error on the integrated counts and a Poisson distribution of the noise associated with the measured counts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Methods and systems for evaluating and improving distribution-grid observability

This document describes systems and techniques for evaluating and improving distribution-grid observability. These systems and techniques allow engineers to quantify the observability of a distribution grid, which represents an ability to combine actual measurements and various types of computations (e.g., analytics, estimators, forecasters), from a system model. Distribution engineers can also identify islands of observability where operating parameters, including voltages, currents, and power flows, can be determined from available sensor readings. By exclusion, distribution engineers can similarly identify areas of the distribution grid with observability deficiencies that may require additional instrumentation to maintain proper operation. Distribution engineers, using an iterative or automated process, can determine the observability of the system model with new or relocated sensors to generate a sensor allocation plan. The sensor allocation plan can indicate the number and location of sensors to either maximize observability for a fixed sensor cost or minimize sensor cost for predetermined observability.

Reiman, Anthony P.↗

Methods and systems for evaluating data transportability in distribution grids

This document describes systems and techniques for evaluating and improving distribution-grid data transportability. These systems and techniques allow engineers to quantify the data transportability of a communication system within or connected to a distribution grid, which represents an ability to transport in real-time telemetry from source locations (e.g., sensors in the distribution grid) to control mechanisms. Distribution engineers can use the sensor readings to perform grid analytics, control operating parameters, and operate protection systems. Distribution engineers can also use the transportability of the communication system to evaluate the observability of the distribution grid, which represents an ability to combine actual measurements and various types of computations (e.g., analytics, estimators, forecasters) from a system model. Distribution engineers can then generate a sensor allocation plan that indicates the number and location of sensors to maximize observability for a fixed sensor cost and/or minimize sensor cost for predetermined observability.

Taft, Jeffrey D.↗

Inverse Mapping of the Collision Kernel and Wall Flux Scaling in a Tall Convection‐Cloud Chamber Using Local Sensors and Knowledge‐Informed Deep Learning

Droplet collision–coalescence is a crucial process in cloud physics, but accurately representing this process under different dynamical conditions remains challenging. A proposed future convective‐cloud chamber aims to investigate this key process, but the method for observing it remains unclear, even though it is theoretically established that collision‐coalescence will occur. This study serves as a proof‐of‐concept demonstration of how knowledge‐informed deep learning, combined with measurement data from local sensors in the chamber, can be used to estimate the collision kernels, which determine how the droplet size distribution evolves during collision‐coalescence. In addition to estimating the collision kernel, we also address wall fluxes, another uncertain but important process that acts as a source of heat and moisture in the chamber. Ensemble runs of large‐eddy simulations are conducted by scaling the wall fluxes and the collision kernel, while the measured flow and cloud properties are used as inputs for a neural network. Results indicate that this approach successfully maps the scaling of wall fluxes and the collision kernel with biases of approximately 1% or less relative to the range of the target data. This proof‐of‐concept lays the groundwork for future applications; when the real measurements are available, real sensor data combined with the trained model presented in this work will enable estimation of the actual wall fluxes and collision kernel.

cloud chamber↗

Developing Generic Prior Distributions for Common Cause Failure Alpha Factors and Causal Alpha Factors

This report is a revision of the original report, INL/LTD-17-43723. Distribution of the original report was to the Nuclear Regulatory Commission (NRC) only, and the report was not made available to the public. The original report was revised as this report for public distribution. This report presents the latest update of generic prior distributions for common cause failure (CCF) alpha factors, as well as the development of new generic prior distributions for CCF causal alpha factors. The history of CCF treatment and parameter estimations is reviewed. The existing process for developing generic prior distributions is reviewed and used to develop new priors for CCF alpha factors and causal alpha factors. For causal alpha factors, different priors are developed for the five different CCF cause groups: Component (GC), Design (GD), Environment (GE), Human (GH), and Other (GO). These generic prior distributions could be used in the Standardized Plant Analysis Risk (SPAR) models for CCF parameter estimation. The issues and preliminary thoughts regarding prior distribution development are documented. Potential future work is then proposed for improving the process of developing priors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantile-Specific Heritability of Inflammatory and Oxidative Stress Biomarkers Linked to Cardiovascular Disease

Purpose: Heritability (h 2 , the proportion of the phenotypic variance attributable to additive genetic effects) is traditionally assumed to be constant throughout the distribution of the phenotype. However, the heritabilities of circulating C-reactive protein, interleukin-6, plasminogen activator inhibitor type-1 (PAI-1), and monocyte chemoattractant protein-1 (MCP-1) concentrations depend upon whether the phenotype is high or low relative to their distributions (quantile-dependent expressivity), which may account for apparent gene–environment interactions. Whether the heritabilities of other inflammatory biomarkers linked to cardiovascular disease are quantile-dependent remain to be determined. Patients and Methods: Quantile-specific offspring-parent (β OP ) and full-sib regression slopes (β FS ) were estimated by applying quantile regression to the age- and sex-adjusted phenotypes of families surveyed as part of the Framingham Heart Study. Quantile-specific heritabilities were calculated as: h 2 =2β OP /(1+r spouse ) and h 2 ={(1+8r spouse β FS ) 0.5 – 1}/(2r spouse ). Results: Heritability (h 2 ± SE) of lipoprotein-associated phospholipase A2 (Lp-PLA 2 ) mass concentrations increased from 0.11 ± 0.03 at the 10 th percentile, 0.08 ± 0.03 at the 25 th , 0.12 ± 0.03 at the 50 th , 0.20 ± 0.04 at the 75 th , and 0.26 ± 0.06 at the 90 th percentile, or 0.0023 ± 0.0006 per each one-percent increase in the phenotype distribution (P linear trend = 0.0004). Similarly, h 2 increased 0.0029 ± 0.0011 (P linear trend = 0.01) for sP-selectin, 0.0032 ± 0.0009 (P linear trend = 0.0001) for soluble intercellular adhesion molecule 1 (sICAM-1), and 0.0026 ± 0.0006 for tumor necrosis factor receptor 2 (TNFR2) (P linear trend = 5.0 × 10 -6 ) per each one-percent increase in their distributions when estimated from β OP . Osteoprotegerin and soluble ST2 heritability also increased significantly with increasing percentiles of their distributions when estimated from β FS . Lp-PLA 2 activity, CD40 ligand, TNFα, interleukin-18, and myeloperoxidase heritability showed no significant quantile-dependence. Conclusion: The heritabilities of circulating Lp-PLA 2 -mass, sP-selectin, sICAM-1, TNFR2, osteoprotegerin and soluble ST2 concentrations are quantile-dependent, which may contribute to purported genetic modulations of: 1) sP-selectin’s relationships to venous thrombosis, pulmonary hypertension, type 2 diabetes and atorvastatin treatment; 2) sICAM-I’s relationships to brain abscess and atorvastatin treatment; and 3) Lp-PLA 2 ’s relationships to myocardial infarction and preeclampsia.

60 APPLIED LIFE SCIENCES↗

A Bayesian Approach to Regional Decadal Predictability: Sparse Parameter Estimation in High-Dimensional Linear Inverse Models of High-Latitude Sea Surface Temperature Variability

Stochastic reduced models are an important tool in climate systems whose many spatial and temporal scales cannot be fully discretized or underlying physics may not be fully accounted for. One form of reduced model, the linear inverse model (LIM), has been widely used for regional climate predictability studies—typically focusing more on tropical or midlatitude studies. However, most LIM fitting techniques rely on point estimation techniques deriving from fluctuation–dissipation theory. In this methodological study we explore the use of Bayesian inference techniques for LIM parameter estimation of sea surface temperature (SST), to quantify the skillful decadal predictability of Bayesian LIM models at high latitudes. We show that Bayesian methods, when compared to traditional point estimation methods for LIM-type models, provide better calibrated probabilistic skill, while simultaneously providing better point estimates due to the regularization effect of the prior distribution in high-dimensional problems. We compare the effect of several priors, as well as maximum likelihood estimates, on 1) estimating parameter values on a perfect model experiment and 2) producing calibrated 1-yr SST anomaly forecast distributions using a preindustrial control run of the Community Earth System Model (CESM). Finally, we employ a host of probabilistic skill metrics to determine the extent to which an LIM can forecast SST anomalies at high latitudes. We find that the choice of prior distribution has an appreciable impact on estimation outcomes, and priors that emphasize physically relevant properties enhance the model’s ability to capture variability of SST anomalies.

54 ENVIRONMENTAL SCIENCES↗

Sensitivity-Based Reactive Power Dispatch of DERs to Support Transmission Grid During Emergency

This paper proposes a TSO-DSO framework including DER set-point dispatch using sensitivity analysis. We address all three steps of TSO-DSO integration stating by estimating the capability curve of an unbalanced distribution system and then modeling of capability curve on the transmission side grid and estimating the reactive power needed from DSO during emergencies, and ending by dispatching the requested reactive power from TSO. The proposed interaction framework is tested on an IEEE 37-node distribution network connected to IEEE 9 bus transmission system. The simulation shows that using sensitivity-based dispatch would reduce the number of communication signals between DERs and DSO and that can decrease the risk of communication contingency.

Alkhonain, Ahmed↗

Conditional H I Mass Functions and the H I -to-halo Mass Relation in the Local Universe

We present a new H I mass estimator that relates log 10 (M HI /M * ) to a linear combination of four galaxy properties: stellar surface mass density, color index u - r, stellar mass, and concentration index, with the scatter of individual galaxies around the mean H I mass modeled with a Gaussian distribution function. We calibrate the estimator using the xGASS sample, including both H I detection and nondetection, and constrain the model parameters through Bayesian inferences. Tests with mock catalogs demonstrate that our estimator provides unbiased H I masses for optical samples like SDSS. We apply our estimator to the SDSS spectroscopic sample to estimate the H I mass function (HIMF) of local galaxies, as well as the conditional H I mass function in galaxy groups and the H I –halo mass relation. Our HIMF agrees with the ALFALFA measurements at M HI ≳ 5 × 10 9 M ⊙ , but with higher amplitude and a steeper slope at lower masses. We show that this discrepancy is caused primarily by the cosmic variance, which is corrected for the SDSS sample but not for ALFALFA. The total CHIMFs for all halo masses can be described by a single Schechter function, while those of central galaxies show a double-Gaussian profile. The total H I mass in a group increases monotonically with halo mass, but for central galaxies, the H I mass shows weak dependence on halo mass when M h ≳ 10 12 M ⊙ . The observed H I –halo mass relation is not reproduced by current hydrodynamic simulations and semianalytic models of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Data for Clumping Index Estimation With 30°-tilted Cameras in Row Crops: Evaluation of Methods and Segment Size Effects

The clumping index (CI) quantifies the spatial distribution of foliage elements and is essential for accurately estimating the plant area index (PAI), canopy radiative transfer, and photosynthesis. Traditionally, the finite-length averaging method (LX), the gap size distribution method (CC), and a combined approach of CC and LX (CLX) have been applied to instruments like TRAC and digital hemispherical photography to estimate CI. However, a comprehensive evaluation of these methods in row crops remains limited, especially regarding the influence of segment size on CI. Meanwhile, digital cameras offer a cost-effective and user-friendly solution for canopy measurements in row crops, yet their application in this context remains underexplored. In this study, we employed a new approach using a 30°-tilted digital camera to estimate CI in corn and soybean fields, applying the LX, CC, and CLX methods. We systematically assessed the performance of these three methods by combining field measurements in real-world fields with simulations using the LESS 3D radiative transfer model. Our results showed that CLX applied to the whole image and 45° segment offered accurate estimation of CI (bias within ±0.1, RMSE < 0.2) and PAI (bias within ±0.4, RMSE < 1) in real-world fields and LESS simulations. The accuracy of the LX method was highly sensitive to segment size, with the best performance observed at the 15° segment (PAI bias within ±0.4). In contrast, the CC method remained stable across different segment sizes, and its performance was generally comparable to that of LX, except at the 15° segment. Across view zenith angles, CI derived from CC generally showed a continuous increase, while those from LX and CLX followed a rising trend at small zenith angles but began to decline at 68°, likely due to an increasing proportion of no-gap segments. Seasonally, LX tended to show decreasing CI during early growth stages but increased as the canopy matured, whereas CC and CLX showed gradually increasing CI before plateauing at peak PAI. The 30°-tilted camera effectively captured CI variations across different angles and growth stages, making it a practical and robust instrument for row crop canopy structure analysis. Applying these CI methods to digital cameras offers a low-cost and accessible CI estimation alternative, improving canopy structure monitoring accuracy in row crops.

Modeling↗