Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distance measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Project Status Update and SIM Science Breadth Discussion for the Origins Subcommittee (OS)

This viewgraph presentation is composed of two sections The first reviews the features and the science goals of the Space Interferometry Mission (SIM). The goals are: (1) Perform a search for other planetary systems by surveying 2000 nearby stars for astrometric signatures of planetary companion, (2) Survey a sample of 200 nearby stars for orbiting planets down to terrestrial-type masses (3) Improve best current catalog of star positions by >lOOx and extend to fainter stars to allow extension of stellar knowledge to include our entire galaxy (4) Study dynamics and evolution of stars and star clusters in our galaxy to understand how our galaxy was formed and how it will evolve. (5) Calibrate luminosities of important stars and cosmological distance indicators to improve our understanding of stellar processes and to measure precise distance in the distant universe. The presentation also reviews the accomplishments since 2002, the plans for the subsequent 6 months. The second entitled "The Breadth of SIM Science," reviews SIM science goals in a larger context. SIM will serve to complement and pave the way for the Terrestrial Planet Finder (TPF). SIM observations of the motions of stars will tell us about the distribution of all gravitating mass (light plus dark matter) in the Galaxy. SIM observations of the motions of dwarf galaxies around our own will determine the mass distribution (light plus dark matter in the Halo. SIM will greatly extend these observations to test the theories of accretion disks around super massive black holes. SIM has advantages for studying AGN and other very compact objects.

Michelson stellar interferometers↗

Tape Measure to the Stars

Calculating distances is one of the thorniest issues of astronomy. But now there are two new, promising methods that may serve as useful yardsticks. The Chandra X-ray Observatory has demonstrated a way to measure distances within the Milky Way and perhaps to nearby galaxies by measuring the delays of X-ray photons as they scatter off intervening matter. The late Compton Gamma-Ray Observatory, through its exhaustive archive of 2,700 gamma-ray bursts, has revealed patterns in these flashes of light that correspond to cosmological distances.

Wanjek, Christopher↗

A novel laser ranging system for measurement of ground-to-satellite distances

A technique was developed for improving the precision of laser ranging measurements of ground-to-satellite distances. The method employs a mode-locked laser transmitter and utilizes an image converter tube equipped with deflection plates in measuring the time of flight of the laser pulse to a distant retroreflector and back. Samples of the outgoing and returning light pulses are focussed on the photocathode of the image converter tube, whose deflection plates are driven by a high-voltage 120 MHz sine wave derived from a very stable oscillator. From the relative positions of the images produced at the output phosphor by the two light pulses, it is possible to make a precise determination of the fractional amount by which the time of flight exceeds some large integral multiple of the period of the deflection sinusoid.

Golden, K. E.↗

Completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: Cosmological implications from two decades of spectroscopic surveys at the Apache Point Observatory

We present the cosmological implications from final measurements of clustering using galaxies, quasars, and Lyα forests from the completed Sloan Digital Sky Survey (SDSS) lineage of experiments in large-scale structure. These experiments, composed of data from SDSS, SDSS-II, BOSS, and eBOSS, offer independent measurements of baryon acoustic oscillation (BAO) measurements of angular-diameter distances and Hubble distances relative to the sound horizon, r d , from eight different samples and six measurements of the growth rate parameter, fσ 8 , from redshift-space distortions (RSD). This composite sample is the most constraining of its kind and allows us to perform a comprehensive assessment of the cosmological model after two decades of dedicated spectroscopic observation. We show that the BAO data alone are able to rule out dark-energy-free models at more than eight standard deviations in an extension to the flat, ΛCDM model that allows for curvature. When combined with Planck Cosmic Microwave Background (CMB) measurements of temperature and polarization, under the same model, the BAO data provide nearly an order of magnitude improvement on curvature constraints relative to primary CMB constraints alone. Independent of distance measurements, the SDSS RSD data complement weak lensing measurements from the Dark Energy Survey (DES) in demonstrating a preference for a flat ΛCDM cosmological model when combined with Planck measurements. The combined BAO and RSD measurements indicate σ 8 =0.85±0.03, implying a growth rate that is consistent with predictions from Planck temperature and polarization data and with General Relativity. When combining the results of SDSS BAO and RSD, Planck, Pantheon Type Ia supernovae (SNe Ia), and DES weak lensing and clustering measurements, all multiple-parameter extensions remain consistent with a ΛCDM model. Regardless of cosmological model, the precision on each of the three parameters, Ω Λ , H 0 , and σ 8 , remains at roughly 1%, showing changes of less than 0.6% in the central values between models. In a model that allows for free curvature and a time-evolving equation of state for dark energy, the combined samples produce a constraint Ω K =-0.0022±0.0022. The dark energy constraints lead to w 0 =-0.909±0.081 and w a =$-0.49_{-0.30}^{+0.35}$, corresponding to an equation of state of w p =-1.018±0.032 at a pivot redshift z p =0.29 and a Dark Energy Task Force Figure of Merit of 94. The inverse distance ladder measurement under this model yields H 0 =68.18±0.79 km s -1 Mpc -1 , remaining in tension with several direct determination methods; the BAO data allow Hubble constant estimates that are robust against the assumption of the cosmological model. In addition, the BAO data allow estimates of H 0 that are independent of the CMB data, with similar central values and precision under a ΛCDM model. Our most constraining combination of data gives the upper limit on the sum of neutrino masses at Σm ν <0.115 eV (95% confidence). Finally, we consider the improvements in cosmology constraints over the last decade by comparing our results to a sample representative of the period 2000-2010. We compute the relative gain across the five dimensions spanned by w, Ω k , Σm ν , H 0 , and σ 8 and find that the SDSS BAO and RSD data reduce the total posterior volume by a factor of 40 relative to the previous generation. Finally, adding again the Planck, DES, and Pantheon SN Ia samples leads to an overall contraction in the five-dimensional posterior volume of 3 orders of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance Analysis of the Spaceborne Laser Ranging System

The 'spaceborne laser ranging system' is a proposed short pulse laser on board an orbiting spacecraft. It measures the distances between the spacecraft and many laser retroreflectors (targets) deployed on the earth's surface. The precision of these range measurements was assumed to be about plus or minus 2 cm. These measurements were then used together with the orbital dynamics of the spacecraft to derive the intersite vector between the laser ground targets. The errors associated with this vector were on the order of 1 to 2 cm. The baseline distances determined range from 25 km to 1200 km. By repeating the measurements of the intersite vector, strain and strain rate errors were estimated. The realizable precision for intersite distance determination was estimated to be on the order of 0.5 cm at 300 km and about 1.5 cm at 1200 km. The corresponding inaccuracies for the intersite distances were larger, than is 1 cm and 3.5 cm respectively. The corresponding precision in the vertical direction was 1 cm and 3 cm.

Kahn, W. D.↗

Computational optimal transport for molecular spectra: The fully continuous case

Computational optimal transport is used to analyze the difference between pairs of continuous molecular spectra. It is demonstrated that transport distances which are derived from this approach may be a more appropriate measure of the difference between two continuous spectra than more familiar measures of distance under many common circumstances. Associated with the transport distances is the transport map which provides a detailed analysis of the difference between two molecular spectra and is a key component of our study of quantitative differences between two continuous spectra. The use of optimal transport for comparing molecular spectra is developed in detail here with a set of model spectra, so that the discussion is self-contained. The difference between the transport distance and more common definitions of distance is elucidated for some well-chosen examples and it is shown where transport distances may be very useful alternatives to standard definitions of distance. The transport distance between a theoretical and experimental electronic absorption spectrum for SO 2 is studied and it is shown how the theoretical spectrum can be modified to fit the experimental spectrum better adjusting the theoretical band origin and the resolution of the theoretical spectrum. In conclusion, this analysis includes the calculation of transport maps between the theoretical and experimental spectra suggesting future applications of the methodology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measuring Large Circumferences More Precisely

Optoelectromechanical gauge measures circumference of large object with resolution of 10 to the negative 4th power inches. Measuring wheel held by spring against cylindrical surface to be measured. Laser reader detects code marks on side of wheel. Marks indicate distance traveled around circumference. Measures inside or outside circumference. Also measures distance between two marks on edge of plate or along beam or track.

Moore, Louis E.↗

Laser Frequency Stabilization for GRACE-II

The GRACE mission monitors changes in the Earth's gravity field by measuring changes in the distance between spacecraft induced by that changing field. The distance variation is measured with a microwave ranging system with sub-micron accuracy. The ranging measurement accuracy is limited by the signal-to-noise ratio and by the frequency stability of the microwave signal referenced to an ultra-stable oscillator (USO). For GRACE-2 a laser ranging system is envisioned with accuracy better than the GRACE microwave ranging system. A laser ranging system easily provides an improved signal-to-noise ratio over the microwave system. Laser frequency stability better than the GRACE USO stability has been demonstrated in several laboratories using thermally stabilized optical cavities. We are developing a space-qualifiable optical cavity and associated optics and electronics for use on GRACE-2 to provide a stable frequency reference for the laser ranging system. Two breadboard units have been developed and tested for performance and ability to survive launch and orbit environments. A prototype unit is being designed using lessons learned from tests of the breadboard units.

Earth gravity↗

High-z Universe with Gamma Ray Bursts

Gamma-Ray Bursts (GRBs) are the most luminous explosions in space and trace the cosmic star formation history back to the first generations of stars. Their bright afterglows allow us to trace the abundances of heavy elements to large distances, thereby measuring cosmic chemical evolution. To date GRBs have been detected up to distances of z=8.23 and possibly even beyond z~9. This makes GRBs a unique and powerful tool to probe the high-z Universe up to the re-ionization era. We discuss the current status of the field, place it in context with other probes, and also discuss new mission concepts that have been planned to utilize GRBs as probes.

Kouveliotou, C.↗

Measurements of the Hubble Constant with a Two-rung Distance Ladder: Two Out of Three Ain’t Bad

Abstract The three-rung distance ladder, which calibrates Type Ia supernovae (SNe Ia) through stellar distances linked to geometric measurements, provides the highest precision direct measurement of the Hubble constant. In light of the Hubble tension, it is important to test the individual components of the distance ladder. For this purpose, we report a measurement of the Hubble constant from 35 extragalactic Cepheid hosts measured by the SH0ES team, using their distances and redshifts at cz ≤ 3300 km s −1 , instead of any more distant SNe Ia, to measure the Hubble flow. The Cepheid distances are calibrated geometrically in the Milky Way, NGC 4258, and the Large Magellanic Cloud. Peculiar velocities are a significant source of systematic uncertainty at z ∼ 0.01, and we present a formalism for both mitigating and quantifying their effects, making use of external reconstructions of the density and velocity fields in the nearby universe. We identify a significant source of uncertainty originating from different assumptions about the selection criteria of this sample, whether distance or redshift limited, as it was assembled over three decades. Modeling these assumptions yields central values ranging from H 0 = 71.7 to 76.4 km s −1 Mpc −1 . Combining the four best-fitting selection models yields H 0 = 72.9 − 2.2 + 2.4 as a fiducial result, at 2.4 σ tension with Planck. While SNe Ia are essential for a precise measurement of H 0 , unknown systematics in these supernovae are unlikely to be the source of the Hubble tension.

79 ASTRONOMY AND ASTROPHYSICS↗

Design aspects of a laser gravitational wave detector in space

Certain optical and mechanical aspects of a proposed laser gravitational wave antenna in space are briefly discussed. The proposed concept consists of a free-mass antenna with the test masses separated by a distance of 1,000,000 km. A laser heterodyne technique is employed to measure the distance change between test masses resulting from gravitational wave interaction. The proposed scheme is considered to offer the necessary sensitivity to detect gravitational radiation from binary stars predicted by General Relativity Theory.

Decher, R.↗

Dense fog on the highway: Visual range monitoring in cars?

This paper reports on the development of a new sensor. Laser range-finders are currently installed in cars and trucks to measure the distance to a proceeding car (LEICA). A modification of such a sensor to measure visibility was made. The problems that had to be solved were: (1) choice of wavelength with relation to the human eye for visibility measurements; (2) dependency of the wavelength on atmospheric turbidity; (3) laser eye-safety; and (4) influence of multiple scattering at visibilities smaller than 200 m. The wavelength used for lidar sensors in the near infrared presents no real problems because the object to be sensed is fog appearing white which means that scattering from fog is wavelength independent. There are however differences in backscatter-to-extinction ratio for different fog and weather situations. The two solutions to these problems are polarization and multiple scattering. As known from airport operations of a laser ceilometer, one can use this multiple scattering contribution to determine the visibility.

Hahn, W.↗

Main-Sequence CMEs as Magnetic Explosions: Compatibility with Observed Kinematics

We examine the kinematics of 26 CMEs of the morphological main sequence of CMEs, those having the classic three-part bubble structure of (1) a bright front eveloping (2) a dark cavity within which rides (3) a bright blob/filamentary feature. Each CME is observed in Yohkoh/SXT images to originate from near the limb (> or equal to 0.7 R(sub Sun) from disk center). The basic data (from the SOHO LASCO CME Catalog) for the kinematics of each CME are the sequence of LASCO images of the CME, the time of each image, the measured radial distance of the front edge of the CME in each image, and the measured angular extent of the CME. About half of our CMEs (12) occur with a flare, and the rest (14) occur without a flare. While the average linear-fit speed of the flare CMEs (1000 km/s) is twice that of the non-flare CMEs (510 km/s), the flare CMEs and the non-flare CMEs are similar in that some have nearly flat velocity-height (radial extent) profiles (little acceleration), some have noticeably falling velocity profiles (noticeable deceleration), and the rest have velocity profiles that rise considerably through the outer corona (blatant acceleration). This suggests that in addition to sharing similar morphology, main-sequence CMEs all have basically the same driving mechanism. The observed radial progression of each of our 26 CMEs is fit by a simple model magnetic plasmoid that is in pressure balance with the radial magnetic field in the outer corona and that propels itself outward by magnetic expansion, doing no net work on its surroundings. On average over the 26 CMEs, this model fits the observations as well as the assumption of constant acceleration. This is compatible with main-sequence CMEs being magnetically driven, basically magnetic explosions, with the velocity profile in the outer corona being largely dictated by the initial Alfien speed in the CME (when the front is at approx. 3 (sub Sun), analogous to the mass of a main-sequence star dictating the luminosity.

Moore, Ron↗

Results from the Baksan Experiment on Sterile Transitions (BEST)

The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos 𝜈𝑒 observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the “gallium anomaly,” which could be interpreted as evidence for oscillations between 𝜈𝑒 and sterile neutrino (𝜈 𝑠 ) states. A 3.414-MCi 51 Cr 𝜈 𝑒 source was placed at the center of two nested Ga volumes and measurements were made of the production of 71 Ge through the charged current reaction, 71 Ga ⁢(𝜈 𝑒 ,𝑒 − ) ⁢71 Ge, at two average distances. The measured production rates for the inner and the outer targets, respectively, are [54.9$^{+2.5}_{−2.4}$⁢(stat) ± 1.4⁢(syst)] and [55.6$^{+2.7}_{−2.6}$⁢(stat) ± 1.4⁢(syst)] atoms of 71 Ge/𝑑. The ratio (𝑅) of the measured rate of 71 Ge production at each distance to the expected rate from the known cross section and experimental efficiencies are 𝑅 in = 0.79 ± 0.05 and 𝑅 out = 0.77 ± 0.05. The ratio of the outer to the inner result is 0.97 ± 0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20%–24% lower than expected, thus reaffirming the anomaly. Furthermore, these results are consistent with 𝜈 𝑒 → 𝜈 𝑠 oscillations with a relatively large Δ⁢𝑚 2 (>0.5 eV 2 ) and mixing sin 2 ⁡2⁢𝜃 (≈ 0.4).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Straight Ahead in Microgravity

This joint ESA-NASA study will address adaptive changes in spatial orientation related to the subjective straight ahead, and the use of a vibrotactile sensory aid to reduce perceptual errors. The study will be conducted before and after long-duration expeditions to the International Space Station (ISS) to examine how spatial processing of target location is altered following exposure to microgravity. This project specifically addresses the sensorimotor research gap "What are the changes in sensorimotor function over the course of a mission?" Six ISS crewmembers will be requested to participate in three preflight sessions (between 120 and 60 days prior to launch) and then three postflight sessions on R+0/1 day, R+4 +/-2 days, and R+8 +/-2 days. The three specific aims include: (a) fixation of actual and imagined target locations at different distances; (b) directed eye and arm movements along different spatial reference frames; and (c) the vestibulo-ocular reflex during translation motion with fixation targets at different distances. These measures will be compared between upright and tilted conditions. Measures will then be compared with and without a vibrotactile sensory aid that indicates how far one has tilted relative to the straight-ahead direction. The flight study was been approved by the medical review boards and will be implemented in the upcoming Informed Crew Briefings to solicit flight subject participation. Preliminary data has been recorded on 6 subjects during parabolic flight to examine the spatial coding of eye movements during roll tilt relative to perceived orientations while free-floating during the microgravity phase of parabolic flight or during head tilt in normal gravity. Binocular videographic recordings obtained in darkness allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the aircraft and head orientations. During some parabolas, a vibrotactile sensory aid provided feedback of body orientation relative to the plane coordinates. RESULTS Both variability and curvature of gaze trajectories increased during roll tilt compared to the upright position. The saccades were less accurate during parabolic flight compared to measurements obtained in normal gravity. Although subjects were instructed to look off in the distance while performing the eye movements, fixation distance varied with vertical gaze direction independent of whether the saccades were made along perceived aircraft or head orientations. The increased errors in gaze trajectories along both perceived orientations during microgravity can be attributed to the otolith's role in spatial coding of eye movements. A change in an individual's egocentric reference might have negative consequences on evaluating the direction of an approaching object or on the accuracy of reaching movements or locomotion. Consequently, investigating how microgravity affects the target location will have theoretical, operational and even clinical implications for future space exploration missions. The use of vibrotactile feedback as a sensorimotor countermeasure is applicable to balance therapy applications for vestibular loss patients and the elderly to mitigate risks due to loss of orientation.

Wood, S. J.↗

The DESI DR1 Peculiar Velocity Survey: Mock Catalog

We describe the production of the official set of mock catalogs for the Dark Energy Spectroscopic Instrument Peculiar Velocity Survey (DESI-PV) Data Release 1 (DR1). Our mock catalogs reproduce the Bright Galaxy Survey number density and clustering at low redshift $(z<0.1)$ and the DESI PV samples of Fundamental plane and Tully-Fisher distances, from which we derive peculiar velocities. We carefully match mock and data properties and we mimic measurements of distance indicators and peculiar velocities, which follow the same statistical properties as real data. Mock samples of type-Ia supernovae also complement the other two distance indicators. Our 675 available mock realizations were used consistently by our three different methodologies described in our companion papers that measure the growth rate of structure $fσ_8$ with DESI PV DR1. Those mocks allow us to perform precise tests of clustering models and uncertainty estimation to an unprecedented level of accuracy, and compute correlations between methodologies. The consensus value for the DESI DR1 PV growth rate measurement is $fσ_8 = 0.450 \pm 0.055$. This sample of mock catalogs represents the largest and most realistic set for cosmological measurements with peculiar velocities to date.

Bautista, J. [Marseille, CPPM]↗

Distances to diffuse interstellar clouds from IRAS measurements and observations of optical absorption lines

Distances to diffuse interstellar clouds were determined from the amount of ultraviolet radiation that penetrates into the cloud and that arises from a nearby B star. The environment around 67 Ophiuchi, 20 Aquilae, kappa Aquilae, and 9 Cephei were studied. The intensities at 60 and 100 micron, as measured by IRAS, were used to derive dust temperatures for the clouds. Enhanced dust temperatures would indicate an influence of the star's radiation field on a cloud. Observation of molecular absorption were compared to the results of simplified chemical models in order to search for enhanced photodissociation that is caused by the star. Enhanced dust temperatures were observed for clouds in the vicinities of 20 Aql, kappa Agl, and 9 Cep. The range of the star's influence was found to be typically 1-5 pc. On the other hand, chemical analyses of the molecular data, which pertain to foreground gas, did not reveal the presence of enhanced dissociative flux from the sample of stars. Thus, upper limits were derived for the distances from the sun to the foreground material.

Federman, S. R.↗

Masses and Luminosities of X-Ray Binaries

Using SIM, we will perform narrow-angle observations of several X-ray binaries to determine their orbits, and we will observe about 50 X-ray binary systems in wide-angle mode to measure their distances and proper motions. Sources with mass estimates for the compact component of greater than 3 solar masses are generally called black hole candidates since this mass is above the theoretical neutron star limit. Narrow-angle observations of these sources provide a direct test of the dynamical mass estimates on which the black hole evidence is based. Better measurements of the black hole masses will provide constraints on possible evolutionary paths that lead to black hole formation. When combined with X-ray data, mass measurements may provide additional constraints on the black hole spin. Precise mass determinations of neutron star systems can address the question of whether neutron stars can be significantly more massive than 1.4 solar masses, which would eliminate soft models of the neutron star equations of state. The wide-angle observations will probe the Galactic distribution of X-ray binaries through parallaxes and proper motions. They will also eliminate the uncertainties in the luminosities of individual sources, which is currently up to a full order of magnitude. This will enable more detailed comparisons of X-ray observations to physical models such as advection-dominated accretion flows (ADAFs). We intend to carry out the following measurements: 1) Determine the orbits of two black hole candidates to measure the black hole masses; 2) Obtain precise mass measurements for two neutron star systems to constrain neutron star equations of state; 3) Determine the distances and thus luminosities of selected representatives of various classes of X-ray binaries (black hole candidates, neutron stars, jet sources); 4) In the process of distance determination, proper motions will also be measured, from which the age of the population can be estimated.

Quirrenbach, Andreas↗