Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

In-situ study of the growth of CuO nanowires by energy dispersive X-ray diffraction

Growth of CuO nanowires by annealing method has been studied in-situ by grazing incidence Energy Dispersive X-ray Diffraction (EDXRD) technique on Indus-2. It was observed that Cu slowly oxidized to Cu{sub 2}O and finally to CuO. The data was taken as a function of time at two annealing temperatures 500 Degree-Sign C where nanowires form and 300 Degree-Sign C where nanowires don't form. We found that the strain in the CuO layer may be a principal factor for the spontaneous growth of nanowires in annealing method.

36 MATERIALS SCIENCE↗

Focused Ion Beam Tomography of Alloy 617 Corroded in Molten Chloride Salt

Materials qualification of reactor structural materials is a critical step in rapid implementation of advanced nuclear reactor technologies, particularly to assess the corrosion performance in these designs. Accelerated qualification of reactor structural materials requires incorporating powerful computational toolsets, such as phase field modelling in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, to predict the evolution of structural materials due to corrosion. Accordingly, computational toolsets will require experimental data generated at appropriate length scales to validate accuracy. Focused ion beam (FIB) provides a high degree of control over manipulation of materials for analytical purposes, including capturing data on the evolution in the microstructure and elemental composition of materials at the mesoscale, an appropriate length scale for phase field modelling of intergranular diffusion phenomena using the MOOSE framework. For instance, the FEI Helios G4 UX dual beam plasma FIB microscope at the Irradiated Materials Characterization Laboratory (IMCL) is capable of backscatter diffraction (EBSD) and energy-dispersive x-ray spectroscopy (EDS) documenting the evolution in the microstructure and elemental composition, respectively. The Helios can perform EDS and EBSD three-dimensionally (3D) using tomography, which is then combined using different software packages to visualize 3D volumes correlating elemental composition to microstructural data. The purpose of this investigation was to develop a streamlined characterization and data processing workflow for 3D tomography studies on the FEI Helios G4 plasma FIB. The investigation is segmented into three parts: 1) Optimizing the data collection workflow, 2) identifying appropriate data processing and visualization software (i.e. DREAM.3D, MIPAR, and VGStudioMax), and 3) establishing an infrastructure for public release. The optimization of the data collection workflow is in collaboration with members of the U220 department to setup formal training on the tomography operation of the G4, through ThermoFisher Scientific, and exploring DREAM.3D, MIPAR, and VGStudioMax data processing/visualization software packages. VGStudioMax currently demonstrates the most promise for future use. Optimization of the data collection and processing workflow is still ongoing. A collaboration with INL High Performance Computing (HPC) established an open-source license for expediting the public release of FIB tomography datasets through HPC. FIB tomography data generated by the G4 will provide comprehensive data for validating 3D phase field mesoscale modelling tools within the MOOSE framework for accelerated qualification of reactor structural materials.

Copeland-Johnson, Trishelle↗

Nanometric resolution using far-field optical tomographic microscopy in the multiple scattering regime

The resolution of optical far-field microscopes is classically diffraction-limited to half the illumination wavelength. We show experimentally that this fundamental limit does not apply in the multiple scattering regime. We used tomographic diffractive microscopy at 633 nm to image two pairs of closely spaced rods (with a width and interdistance of 50 nm) of widely different diffractive properties. Using an inversion algorithm accounting for multiple scattering, only the pair of highly diffracting rods could be clearly visualized with a resolution similar to that of an atomic force microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-09: The Impact of X-Ray Scattering On Image Noise for Dedicated Breast CT

Purpose: To quantify the impact of detected x-ray scatter on image noise in flat panel based dedicated breast CT systems and to determine the optimal scanning geometry given practical trade-offs between radiation dose and scatter reduction. Methods: Four different uniform polyethylene cylinders (104, 131, 156, and 184 mm in diameter) were scanned as the phantoms on a dedicated breast CT scanner developed in our laboratory. Both stationary projection imaging and rotational cone-beam CT imaging was performed. For each acquisition type, three different x-ray beam collimations were used (12, 24, and 109 mm measured at isocenter). The aim was to quantify image noise properties (pixel variance, SNR, and image NPS) under different levels of x-ray scatter, in order to optimize the scanning geometry. For both projection images and reconstructed CT images, individual pixel variance and NPS were determined and compared. Noise measurement from the CT images were also performed with different detector binning modes and reconstruction matrix sizes. Noise propagation was also tracked throughout the intermediate steps of cone-beam CT reconstruction, including the inverse-logarithmic process, Fourier-filtering before backprojection. Results: Image noise was lower in the presence of higher scatter levels. For the 184 mm polyethylene phantom, the image noise (measured in pixel variance) was ∼30% lower with full cone-beam acquisition compared to a narrow (12 mm) fan-beam acquisition. This trend is consistent across all phantom sizes and throughout all steps of CT image reconstruction. Conclusion: From purely a noise perspective, the cone-beam geometry (i.e. the full cone-angle acquisition) produces lower image noise compared to the lower-scatter fan-beam acquisition for breast CT. While these results are relevant in homogeneous phantoms, the full impact of scatter on noise in bCT should involve contrast-to-noise-ratio measurements in heterogeneous phantoms if the goal is to optimize the scanning geometry for dedicated breast CT. This work was supported by a grant from the National Institute for Biomedical Imaging and Bioengineering (R01 EB002138)

60 APPLIED LIFE SCIENCES↗

Revenido de un acero bain?tico nanoestructurado: un an?lisis a nivel at?mico

New developments with bainite have resulted in a steel with an ultimate tensile strength of 1.7-2.5 GPa and a toughness in excess of 30-40 MPa m1/2. The novel microstructure is generated in a high carbon high silicon steel isothermally transformed at temperatures of 200 C-350 C. Iron does not diffuse during the transformation to bainite at this low temperature. As a result, 20-40 nm thick plates of ferrite are generated, giving rise to the exceptional properties. X-ray diffraction results indicated that the carbon concentration in the bainitic ferrite was much higher than that expected from equilibrium thermodynamics between austenite and ferrite. Atom probe tomography demonstrated that a substantial quantity of carbon (7.4 at. % C) was found to be trapped at dislocations in the vicinity of the ferrite/austenite interface. Carbon trapping at dislocations was found to prevent the decarburization of supersaturated ferrite and in some extent to alter the carbide precipitation sequence during low temperature bainite formation. These results provided the first direct observation of carbon Cottrell Atmospheres in bainitic ferrite. There are important differences in the tempering behavior of bainite and martensite. Much of the carbon precipitates as carbides or partitions from the ferrite to the remaining austenite during bainite formation. As a consequence the bainitic microstructure is less sensitive to additional tempering heat treatment. In contrast, the level of carbon in the bainitic ferrite of this novel bainitic steel is unusually high. Redistribution of alloying elements during tempering of this nanocrystalline steel has been analysed by atom probe tomography. Results suggest that retained austenite decomposes during tempering before full equilibrium is reached at the interface. Moreover, cementite precipitates from supersaturated ferrite via a paraequilibrium transformation mechanism.

36 MATERIALS SCIENCE↗

Synthesis of precipitation-strengthened Al-Sc, Al-Zr and Al-Sc-Zr alloys via selective laser melting of elemental powder blends

Selective laser melting is used to create Al-1.5Sc, Al-1.5Zr and Al-0.75Sc-0.75Zr (at.%) alloys from blends of elemental Al, Sc, and Zr powders. This study investigates elemental alloying elements (Sc and Zr) which are high-melting and highly reactive, unlike previous work which focused on more concentrated elemental additions of lower-melting, lower-reactivity Cu and Si to aluminum. High-speed in situ synchrotron x-ray imaging and diffraction show that the 20–30 μm Al, Sc, and Zr powders fully melt and sufficiently mix in the molten state to create, on solidification, a homogeneous distribution of primary, micron-size L12 precipitates (Al 3 Sc, Al 3 Zr, and Al 3 (Sc,Zr), respectively) and nucleate micron-size Al matrix grains, as confirmed by SEM imaging of cross-sections. Here, a second laser pass, simulating a realistic additive-manufacturing build condition, fully remelts the initial volume which shows, after solidification, the same Al 3 (Sc,Zr) L1 2 primary micro-precipitates and very fine Al grains. After aging at 300–400°C, the alloys show large increases in hardness, consistent with an exceptionally high number density (1.4 × 10 24 m –3 ) and volume fraction (2.5%) of secondary Al 3 (Sc,Zr) nano-precipitates with a Sc-rich core and Zr-rich shell, as measured via atom-probe tomography.

36 MATERIALS SCIENCE↗

Analysis of heterogeneities in strain and microstructure in aluminum alloy and magnesium processed by high-pressure torsion

Two distinct bulk light metals were opted to study the shear strain evolution and associated heterogeneities in texture/microstructure development during torsional straining by high pressure torsion (HPT): a face centered cubic Al alloy (A5086) and a hexagonal commercial purity Mg. Relatively thick disk samples - four times thicker than usually employed in HPT process - were processed to 180° and 270° rotations. With the help of X-ray tomography, the shear strain gradients were examined in the axial direction. The results showed strongly localized shear deformation in the middle plane of the disks in both materials. These gradients involved strong heterogeneities in texture, microstructure and associated hardness, in particular through the thickness direction at the periphery of the disk where the interplay between significant strain hardening and possible dynamic recrystallization could occur. - Highlights: •HPT processing was conducted on bulk specimens thicker than the usual thin-disks. •The Al alloy (A5086) and commercial purity magnesium samples were compared. •Distributions of strain and microhardness were evaluated in the radial and axial direction. •Plastic deformation is highly localized in the middle plane at outer edge in both materials. •Different DRX rates governed the differences in microstructure and hardening behavior.

36 MATERIALS SCIENCE↗

Present and Future X-ray Tomographic Microscopy at TOMCAT

During its first four years of life, the TOMCAT beamline at the Swiss Light Source has established itself as a state-of-the art hard x-ray tomographic microscopy endstation for experiments on a large variety of samples, ranging from the fields of biology to materials science. It routinely performs absorption as well as phase-contrast imaging with an isotropic voxel size ranging from 0.360 up to 14.8 microns. Phase contrast is obtained either with simple edge-enhancement, a modified transport of intensity approach or grating interferometry. Typical acquisition times are on the order of a few minutes, depending on energy and resolution. A recently implemented automatic sample exchanger is now available for high-throughput studies. In addition to further developments in phase-contrast imaging, current scientific activities at the beamline focus on pushing spatial and temporal resolution by a few orders of magnitude, aiming at nano- and 'real-time' tomography.

43 PARTICLE ACCELERATORS↗

Thermal etching of silver: Influence of rolling defects

Silver is well known to be thermally etched in an oxygen-rich atmosphere and has been extensively studied in the laboratory to understand thermal etching and to limit its effect when this material is used as a catalyst. Yet, in many industrial applications the surface of rolled silver sheets is used without particular surface preparation. Here, it is shown by combining FIB-tomography, FIB-SIMS and analytical SEM that the kinetics of thermal etch pitting are significantly faster on rolled Ag surfaces than on polished surfaces. This occurs due to range of interacting phenomena including (i) the reaction of subsurface carbon-contamination with dissolved oxygen to form pores that grow to intersect the surface, (ii) surface reconstruction around corrosion pits and surface scratches, and (iii) sublimation at low pressure and high temperature. A method to identify subsurface pores is developed to show that the pores have (111) and (100) internal facets and may be filled with a gas coming from the chemical reaction of oxygen and carbon contamination. - Highlights: Thermal etching of industrial silver sheets vs. polished silver sheets Effect of annealing atmosphere on the thermal etching of silver: surface and subsurface characterization Link between etch pitting and defects induced by rolling. FIB-tomography coupled with EBSD for determining crystal planes of the facets of subsurface pores. FIB-SIMS characterization to probe the gas confined inside subsurface pores.

36 MATERIALS SCIENCE↗

Rapid grain refinement and compositional homogenization in a cast binary Cu50Ni alloy achieved by friction stir processing

Friction stir processing (FSP) has been increasingly adopted for joining and processing materials in automotive, aerospace and industrial construction. During FSP a dynamic competition between high-speed shear deformation and deformation-induced heating brings about a complex competition between multiple dynamic microstructural evolution mechanisms making it difficult to predict the microstructural evolution pathway. Hence, improved understanding of microstructural evolution mechanisms during FSP can be beneficial for continued growth in the adoption of FSP for demanding applications of future. Towards this goal, this study uses a model binary Cu – 50 at.% Ni alloy to clarify the effect of single and double pass FSP on the microstructural evolution of a coarse grained and compositionally heterogeneous cast microstructure. High energy synchrotron X-ray diffraction, electron backscatter diffraction, and nanoindentation are used to clarify the microstructural evolution due to FSP. The process of compositional homogenization of as-cast segregations is studied by energy dispersive spectroscopy and atom probe tomography. Our results show that a single fast FSP pass at 30 mm.s -1 produces a 100 µm deep layer of submicrometric and hall-petch hardened CuNi grains. The initial cast compositional heterogeneities in a micrometric scale is rapidly transformed to nano-sized domains, mainly confined at grain boundaries. Double pass FSP increases the penetration depth of the processed layer and leads to a 2.9 times grain growth relative to single pass FSP. Grain fragmentation, discontinuous dynamic recrystallization, grain growth, and twinning mechanisms are discussed. In conclusion, these results highlight the value of FSP for ultrafast grain refinement and compositional homogenization of cast alloys.

36 MATERIALS SCIENCE↗

A general framework and review of scatter correction methods in cone beam CT. Part 2: Scatter estimation approaches

The main components of scatter correction procedures are scatter estimation and a scatter compensation algorithm. This paper completes a previous paper where a general framework for scatter compensation was presented under the prerequisite that a scatter estimation method is already available. In the current paper, the authors give a systematic review of the variety of scatter estimation approaches. Scatter estimation methods are based on measurements, mathematical-physical models, or combinations of both. For completeness they present an overview of measurement-based methods, but the main topic is the theoretically more demanding models, as analytical, Monte-Carlo, and hybrid models. Further classifications are 3D image-based and 2D projection-based approaches. The authors present a system-theoretic framework, which allows to proceed top-down from a general 3D formulation, by successive approximations, to efficient 2D approaches. A widely useful method is the beam-scatter-kernel superposition approach. Together with the review of standard methods, the authors discuss their limitations and how to take into account the issues of object dependency, spatial variance, deformation of scatter kernels, external and internal absorbers. Open questions for further investigations are indicated. Finally, the authors refer on some special issues and applications, such as bow-tie filter, offset detector, truncated data, and dual-source CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reduced diffusion and enhanced retention of multiple radionuclides from pore structure characterization of barrier materials for enhanced repository performance

Fluid flow and chemical transport in porous media are the macroscopic consequences of pore structure, which integrates geometry (e.g., pore size and surface area, pore-size distribution) and topology (e.g., pore connectivity). Low-permeability geological media whose pores are poorly interconnected will exhibit the characteristics of anomalous diffusion and sample size-dependent effective porosity, which will strongly impact long-term net diffusion and retention of radionuclides in geological repository settings involving different host rocks and barrier materials. A suite of innovative and complementary experimental approaches is utilized to study the microscopic pore structure and macroscopic fluid flow & chemical transport for a range of host rocks and barrier materials, in addition to standard clay minerals and reference rocks. With a particular focus on quantifying the presence and magnitude of “isolated” pores for a reduced effective porosity in low-permeability geomedia, the integrated methodologies for basic properties and pore structure characterization of these geomedia include X-ray diffraction, thin section petrography, grain size distribution, water immersion porosimetry after vacuum-pulling for full saturation, mercury intrusion porosimetry, nitrogen physisorption, scanning electron microscopy, X-ray computed tomography, and (ultra-)small angle neutron (X-ray) scattering. In addition, custom-designed gas diffusion, tracer recipe involving a range of anionic and cationic chemicals with subsequent analyses by laser ablation and inductively coupled plasma-mass spectrometry, along with batch sorption, column transport, and imbibition tests were conducted for coupled effects of pore structure and chemical retention/transport. From the perspectives of pore structure in conjunction with multiple and complementary approaches to examining a range of sample sizes under different observational scales, we find that the poor pore connectivity is prevalent in low-permeability media (mudstone and crystalline rock) that is related to geological processes (e.g., compaction, diagenesis and thermal maturation). For example, the deep and organic matter-rich mudstones have a much smaller effective porosity than the total porosity (as a result of poor pore connectivity) and associated diffusion coefficient, and the effective porosity & diffusion coefficients are also dependent upon the sample sizes used in the measurement. Similarly, most of the pore space in the shallow mudstone is also controlled by pore-throat diameters in the 5-50 nm range of intergranular pore types from its fine-grained nature, but with an overall good pore connectivity. However, the nm-sized pore space (physically pore-network architecture) and strong sorption capacities (chemical retention from clay minerals) of both shallow and deep mudstones lead to the synergistic retention of cationic radionuclides and their utilities as effective host rocks and barrier materials. Our unique approaches of studying how the micro-scale pore structure affect macro-scale fluid flow, diffusion & retention, and chemical transport produce improved mechanistic understanding, and realistic quantification, of diffusion and retention of typical radionuclides in a range of generic host rocks and barrier materials (clay/shale, salt, crystalline rock, and tuff), with the overall results leading to scientifically-based understanding of enhanced isolation (from both diffusion and retention) of radionuclides and improved confidence on the long-term performance of geological repository to store high-level radioactive wastes. In addition to the training of 25 undergraduates, graduates, and postdocs of UTA, the scientists (organizations) involved in performing this work (e.g., discussion, sample sharing, and operation of SANS and SAXS instruments) include Ed Matteo, Yifeng Wang, and Kristopher Kuhlman (Sandia National Laboratories), Jens Birkholzer, Liange Zheng, Tim Kneafsey, and Sharon Borglin (Lawrence Berkeley National Laboratory), Mavrik Zavarin (Lawrence Livermore National Laboratory), Yukio Tachi and Yuta Fukatsu (Japan Atomic Energy Agency), Mieke de Craen (Euridice, Belgium), Markus Bleuel (NIST), Wei-Ren Chen, Gergely Nagy, Changwoo Do, William Heller, Larry Anovitz, and Kenneth Littrell (ORNL), as well as Jan Illvsky, Ivan Kuzmenko, Ju-Sang Park and Jon Almers (ANL). Key deliverables include a total of 13 peer-reviewed journal articles (nine published and three under review), 23 presentations at scientific conferences (AAPG, AAPG Southwest Section, AGU, Asian Clay Conference, GSA, GSA South-Central Section, IHLRWM, InterPore, International Conference on Chemistry and Migration Behavior of Actinides and Fission Products in the Geosphere, International Conference on Coupled Processes in Fractured Geological Media: Observation, Modeling and Application), and academic institutions (UTA, New Mexico State University; University of Poitiers, France; University of Helsinki, Finland; Uppsala University, Sweden; Istanbul Technical University, Turkey) and other organizations (Andra, France; Posiva Oy, Finland).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Brady’s Geothermal Field Computed Tomography Core Characterization

We present a publicly accessible database centered around multi-scale Computed Tomographic (CT) imaging of samples from the BCH-03 well, supplemented by a wide range of supporting geological analyses (Brown, et al., 2022). The data include detailed petrologic descriptions of core samples, core-scale medical CT scans, high-resolution micro-CT scans, thin section photomicrographs, elemental abundance data from X-ray diffraction, velocity wave measurements, and helium porosimetry of the matrix.

computed tomography↗

Optimization of TiO{sub 2} photoelectrode with titanium isopropoxide for flexible dye sensitized solar cells

Flexible DSSC uses plastic substrate such as polyethylene terephthalate (PET) to deposit photoelectrode, resulting in poor photoconversion efficiency of the solar cell due to the low temperature applied in the fabrication process. In this research, optimization process was examined in order to optimize the performance of flexible DSSC by adding titanium isopropoxide (TTIP) as a binder to TiO{sub 2} paste for DSSC photoelectrode. Small portion of TTIP with molar percentages of 0%, 5%, and 10% were added to a mixture of TiO{sub 2} nanocrystaline, butanol, DI water, and reflector powder. The mixtures were stirred using a magnetic stirrer for 24 hours. Each of various pastes was then deposited on a plastic substrate with doctor blade method on 1 cm{sup 2} area. The films were sintered at temperature of 150 °C for 4 hours and soaked in dye solution for 24 hours. Furthermore, TiO{sub 2} photoelectrode and Pt counter electrode were assembled and injected by electrolyte. Flexible DSSCs were characterized by SEM and XRD to determine their morphological structures. J-V measurement was performed by sun simulator to calculate DSSC photoconversion efficiency. The optimum performance of flexible DSSC was achieved by DSSC with 10 mol% TTIP content.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of cation stoichiometry on surface morphology and crystallinity of ZnGeN 2 films grown on GaN by metalorganic chemical vapor deposition

ZnGeN 2 films were grown on GaN-on-sapphire templates via metalorganic chemical vapor deposition. Energy dispersive X-ray spectroscopy was used to estimate the Zn/(Zn+Ge) composition ratio in the films. This ratio decreased with increase in growth temperature but increased with increase in total reactor pressure or Zn/Ge precursor flow rate ratio. Systematic mapping of these key growth parameters has allowed us to identify the growth window to achieve ZnGeN 2 with stoichiometric cation composition. Compositional and statistical analyses performed on data acquired from atom probe tomography provided insight into the local compositional homogeneity. The cations Zn and Ge did not demonstrate segregation or clustering at the sub-nanometer level. Based on X-ray diffraction 2θ-ω scan profiles and transmission electron microscope nano-diffraction patterns, the films with near-stoichiometric cation ratios were single crystalline with planar surfaces, whereas zinc-rich or zinc-poor films were polycrystalline with nonplanar surfaces. The growth direction of the single crystalline ZnGeN 2 films on GaN templates was along the c-axis. Room temperature Raman spectra showed features associated with the phonon density of states, indicating the presence of cation disorder in the lattice. A cathodoluminescence peak associated with transitions involving deep level defects was observed around 640 nm. The intensity of this peak increased by almost 2.5 times as the temperature was reduced to 77 K from room temperature. A similar peak was observed in photoluminescence spectra collected at 80 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of grain size on damage and failure in two-phase materials: Homogenized CuPb

It is well known that spall failure strongly depends on the microstructure of a material. There have been numerous studies to study the effect of grain size on the overall spall strength and the total amount of damage in single element metals like copper. However, such systematic studies remain rare in two-phase materials and alloys. In this work, two incipient spall experiments were performed on a Cu–1%Pb alloy to understand the effect of grain size on the damage and failure in a two-phase material. Overall, these results showed that even though the spall strength did not change as a function of grain size, there were significant differences in the total amount of damage as a function of grain size. A clear increase in the total damage present in the material was seen as the grain size was increased from 32 to either 70 or 75 μm in either of the experiments. Furthermore, this difference was attributed to variations in the void growth rate as the grain size was increased.

36 MATERIALS SCIENCE↗

Scatter correction method for x-ray CT using primary modulation: Phantom studies

Purpose: Scatter correction is a major challenge in x-ray imaging using large area detectors. Recently, the authors proposed a promising scatter correction method for x-ray computed tomography (CT) using primary modulation. Proof of concept was previously illustrated by Monte Carlo simulations and physical experiments on a small phantom with a simple geometry. In this work, the authors provide a quantitative evaluation of the primary modulation technique and demonstrate its performance in applications where scatter correction is more challenging. Methods: The authors first analyze the potential errors of the estimated scatter in the primary modulation method. On two tabletop CT systems, the method is investigated using three phantoms: A Catphan(c)600 phantom, an anthropomorphic chest phantom, and the Catphan(c)600 phantom with two annuli. Two different primary modulators are also designed to show the impact of the modulator parameters on the scatter correction efficiency. The first is an aluminum modulator with a weak modulation and a low modulation frequency, and the second is a copper modulator with a strong modulation and a high modulation frequency. Results: On the Catphan(c)600 phantom in the first study, the method reduces the error of the CT number in the selected regions of interest (ROIs) from 371.4 to 21.9 Hounsfield units (HU); the contrast to noise ratio also increases from 10.9 to 19.2. On the anthropomorphic chest phantom in the second study, which represents a more difficult case due to the high scatter signals and object heterogeneity, the method reduces the error of the CT number from 327 to 19 HU in the selected ROIs and from 31.4% to 5.7% on the overall average. The third study is to investigate the impact of object size on the efficiency of our method. The scatter-to-primary ratio estimation error on the Catphan(c)600 phantom without any annulus (20 cm in diameter) is at the level of 0.04, it rises to 0.07 and 0.1 on the phantom with an elliptical annulus (30 cm in the minor axis and 38 cm in the major axis) and with a circular annulus (38 cm in diameter). Conclusions: On the three phantom studies, good scatter correction performance of the proposed method has been demonstrated using both image comparisons and quantitative analysis. The theory and experiments demonstrate that a strong primary modulation that possesses a low transmission factor and a high modulation frequency is preferred for high scatter correction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical Application of Synchrotron Based Hard Xray Micorprobes in Soil Sciences

Many of the most pressing questions in soil sciences require characterization of elemental abundances and speciation in minute samples that are heterogeneous at the submicrometer scale. This science addresses a wide gamut of environmental and health issues of high societal impact. Synchrotron radiation sources are ideal for developing high-intensity, highly focused X-ray probes and those that have been developed to deliver high-energy photons, so-called hard X-ray microprobes (HXRM), have had a major impact in advancing our understanding of the speciation, transport, and reactions of chemical species in soils. X-ray microprobe techniques offer distinct advantages over other analytical techniques by allowing analyses to be done in situ, an important example being the ability to determine chemical speciation of a wide variety of toxic elements in moist soils and biological specimens with little or no chemical pretreatment and low detection limits. In particular, coupled microfocused X-ray fluorescence, spectroscopy, and diffraction analysis allows one to quantify the abundance and speciation of elements in these materials at trace element concentrations and evaluate the mineralogy to which they are adsorbed or bound. Increasingly, these analyses are being done as imaging experiments not only in two dimensions but three dimensionally (3D) using tomographic techniques as well. Such information is crucial in understanding the toxicity, mobility, and containment of contaminating metals in the environment, mechanisms of trace element partitioning, and paths of strategic metal enrichment in nature.

54 ENVIRONMENTAL SCIENCES↗