Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Catalytic Adventures in Space and Time Using High Energy X-rays

Very high energy X-rays have long offered great promise in providing great insight into the inner workings of catalysts; insights that may complement the array of techniques available to researchers in catalysis either in the laboratory or at more conventional X-ray wavelengths. This contribution aims to critically assess the diverse possibilities now available in the high energy domain as a result of the maturation of third generation synchrotron facilities and to look forward to the potential that forthcoming developments in synchrotron source technology may offer the world of catalysis in the near future.

36 MATERIALS SCIENCE↗

Effect of synthesis temperature on the phase formation of NiTiAlFeCr compositionally complex alloy thin films

Here, the synthesis temperature dependent phase formation of Ni 10 Ti 10 Al 25 Fe 35 Cr 20 thin films is compared to a bulk processed sample of identical composition. The as-cast alloy exhibits a dual-phase microstructure which is composed of a disordered BCC phase and AlNiTi-based B2- and/or L2 1 -ordered phase(s). Formation of the BCC phase as well as an ordered AlNi-based B2 phase is observed for a thin film synthesised at 500 °C (ratio of synthesis temperature of thin film to melting temperature of bulk alloy: T/T m = 0.49), which is attributed to both surface and bulk diffusion mediated growth. Post deposition annealing at 900 °C (T/T m = 0.75) of a thin film deposited without intentional heating results in the formation of NiAlTi-based B2 and/or L2 1 -phase(s) similar to the bulk sample, which is attributed to bulk diffusion. Depositions conducted at room temperature without intentional substrate heating (T/T m = 0.20) resulted in the formation of an X-ray amorphous phase, while a substrate temperature increase to 175 °C (T/T m = 0.28) causes the formation of a BCC phase. Atom probe tomography of the thin films deposited without intentional substrate heating and at 175 °C indicates the formation of ~5 nm and ~10 nm FeAl-rich domains, respectively. This can be rationalized based on the activation energy for surface diffusion, as Ti and Ni exhibt 2.5 to 4 times larger activation energy barriers than Al, Fe and Cr. It is evident from the homologous temperature that the phase formation observed at 500 °C (T/T m = 0.49) is a result of both surface and bulk diffusion. As the temperature is reduced, the formation of FeAl-rich domains can be understood based on the differences in activation energy for surface diffusion and is consistent with kinetically limited thin film growth.

36 MATERIALS SCIENCE↗

X-ray phase laminography with a grating interferometer using iterative reconstruction

X-ray phase computed laminography is performed using a Talbot interferometer and synchrotron radiation. An iterative reconstruction algorithm which includes prior information about limited support, range of values and sparsity of the imaged object has been developped. It allows the reconstruction of objects with an improved resolution of the unsampled frequencies, compared to the classical filtered backprojection. The imaging method, demonstrated for a nylon mesh sample and a leaf sample, shows promising results for the imaging of flat, laterally extended objects made of low absorbing elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New developments in structure-property and amorphous materials research at the upgraded 16-BM-B Paris-Edinburgh press station at HPCAT

Beamline 16-BM-B of the High-Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source (APS) provides a Paris-Edinburgh press program to probe the structure and properties of crystalline and amorphous materials up to 12 GPa at room temperature or 7 GPa at 2000°C. During the recent APS upgrade, 16-BM-B undertook major improvements to its instrumentation and measurement techniques. The upgrade includes the addition of a 1.2 m horizontal “condenser” mirror and a new variable-sized collimation system, the combination of which decreases the acquisition time for energy dispersive X-ray diffraction measurements by a factor of 10 when compared to pre-upgrade measurements. The addition of a new Ge energy-sensitive detector and DANTE (XGLab) digital pulse processor allows for processing the increased diffraction counts with minimal deadtime. In addition to upgraded beamline components, new techniques are being developed for eventual release to the user community, including electrical resistivity and tomography measurements.

APS upgrade↗

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simulations in order to identify artifacts in the reconstructions, which is crucial for the interpretation of experimental data.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron and X-Ray Diffraction Studies of Advanced Materials

The selection of articles in the special topic 'Neutron and X-Ray Studies of Advanced Materials' is based on the materials presented during the TMS 2009 annual meeting in San Francisco, CA, February 15-19, 2009. The development of ultrabrilliant third-generation synchrotron X-ray sources, together with advances in X-ray optics, has created intense X-ray microbeams, which provide the best opportunities for in-depth understanding of mechanical behavior in a broad spectrum of materials. Important applications include ultrasensitive elemental detection by X-ray fluorescence/absorption and microdiffraction to identify phase and strain with submicrometer spatial resolution. X-ray microdiffraction is a particularly exciting application compared with alternative probes of crystalline structure, orientation, and strain. X-ray microdiffraction is nondestructive with good strain resolution, competitive or superior spatial resolution in thick samples, and with the ability to probe below the sample surface. Moreover, the high-energy X-ray diffraction technique provides an effective tool for characterizing the mechanical and functional behavior in various environments (temperature, stress, and magnetic field). At the same time, some neutron diffraction instruments constructed mainly for the purpose of engineering applications can be found at nearly all neutron facilities. The first generation-dedicated instruments designed for studying in-situ mechanical behavior have been commissioned and used, and industrial standards for reliable and repeatable measurements have been developed. Furthermore, higher penetration of neutron beams into most engineering materials provides direct measurements on the distribution of various stresses (i.e., types I, II, and III) beneath the surface up to several millimeters, even tens of millimeters for important industrial components. With X-ray and neutron measurements, it is possible to characterize material behavior at different length scales. It is predicted that the application of these techniques, in combination with theoretical simulations and numerical modeling, will lead to major breakthroughs in materials science in the foreseeable future, which will contribute to the development of materials technology and industrial innovation. Specifically, the use of these techniques provides bulk material properties that further augment new characterization tools including the increased use of atom probe tomography and high-resolution transmission electron microscopy systems. The combination of these techniques greatly assists the material property models that address multi-length-scale mechanisms. Different applications of diffuse scattering for understanding the fundamental materials properties are illustrated in the articles of Welberry et al., Goossens and Welberry, Campbell, Abe et al., Gilles et al., and Zhang et al. Analysis of thin films and two-dimensional structures is described in the articles of Gramlich et al., Brock et al., Vigliante et al., Kuzel et al., and Davydok et al. Recent advances in the line profile analysis are represented by the the articles of Scardi et al., Ungar et al., and Woo et al. Characterization of modern alloys is presented by the articles of Wollmershauser et al., Eidenberger et al., Garlea et al., Jia et al., Soulami et al., Wilson et al., and Wang et al. The collected articles are written by different scientific X-ray and neutron research groups. They represent a general trend in the development and application of diffraction techniques all over the world.

36 MATERIALS SCIENCE↗

Distribution of unresolvable anisotropic microstructures revealed in visibility-contrast images using x-ray Talbot interferometry

X-ray Talbot interferometry has been widely used as a technique for x-ray phase imaging and tomography. We propose a method using this interferometry for mapping distribution of parameters characterizing anisotropic microstructures, which are typically of the order of {mu}m in size and cannot be resolved by the imaging system, in a sample. The method uses reduction in fringe visibility, which is caused by such unresolvable microstructures, in moire images obtained using an interferometer. We applied the method to a chloroprene rubber sponge sample, which exhibited uniaxial anisotropy of reduced visibility. We measured the dependencies of reduced visibility on both the Talbot order and the orientation of the sample and obtained maps of three parameters and their anisotropies that characterize the unresolvable anisotropic microstructures in the sample. The maps indicated that the anisotropy of the sample's visibility contrast mainly originated from the anisotropy of the microstructure elements' average size. Our method directly provides structural information on unresolvable microstructures in real space, which is only accessible through the ultra-small-angle x-ray scattering measurements in reciprocal space, and is expected to be broadly applied to material, biological, and medical sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Bismuth Metal–Organic Framework as a Contrast Agent for X-ray Computed Tomography

A new bismuth metal–organic framework (MOF), bismuth-NU901 (Bi-NU-901), featuring the scu topology and a pore with a diameter of ~11 Å, was solvothermally synthesized, and its use as an X-ray computed tomography (CT) contrast agent was tested. X-ray CT is a common diagnostic method used in the medical field. Inside the body, contrast media enhance the distinction between tissues and organs of similar density. Bi-NU-901 consists of eight connected Bi 6 nodes and tetratopic 1,3,5,8-( p -benzoate)pyrene linkers (TBAPy). Numerous material characterization studies including powder X-ray diffraction (PXRD), scanning transmission electron microscopy (STEM), and DFT pore size distribution support the scu structure. Additionally, given the framework’s high density of nontoxic heavy atoms, Bi-NU-901 was evaluated as an X-ray computed tomography (CT) agent. Importantly, in vitro studies revealed this new bismuth MOF demonstrates p7 times better contrast intensity compared to a zirconium MOF featuring the same topology and ~14 times better contrast than a commercially available CT contrast agent. Furthermore these results suggest bismuth MOFs may be promising CT contrast agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The characterization of secondary electron emitters for use in large area photo-detectors.

The Large-Area Picosecond Photo-Detector Project is focused on the development of large-area systems to measure the time-of-arrival of relativistic particles with, ultimately, 1 pico-second resolution, and for signals typical of Positron-Emission Tomography (PET), a resolution of about 30 pico-seconds. Our contribution to this project is to help with identification and efficient fabrication of novel electron emitting materials with properties optimized for use in such detectors. We have assembled several techniques into a single ultra-high vacuum apparatus in order to enable characterization of both photocathode and secondary electron emission (SEE) materials. This apparatus will examine how photocathode quantum efficiency and SEE material electron yield correlate to surface chemical composition, state, and band structure. The techniques employed in this undertaking are X-ray photoelectron spectroscopy (XPS) for surface chemical composition, ultraviolet photoelectron spectroscopy (UPS) for the determination of band structure and surface work function, as well surface cleaning techniques such as argon-ion sputtering. To determine secondary electron emission yields and quantum efficiencies of detector materials, we use electron optics from a low energy electron diffraction (LEED) system whose set of hemispherical electrodes allows for efficient collection of secondary and photo electrons. As we gain a stronger insight into the details of mechanisms of electron emission from photocathodes and SEE materials, we will be able to lay a foundation for the larger collaborative effort to design the next generation of large-area photo-detectors. We present our preliminary results on the SEE materials from our as-yet completed characterization system.

43 PARTICLE ACCELERATORS↗

Structure evolution and tin redistribution during oxidation of Zircaloy-4 at 500°C

Zirconium (Zr) alloys are widely used as fuel cladding in nuclear power reactors due to their thermal stability, mechanical durability, corrosion resistance, and low neutron absorption cross-section. However, their performance is challenged by oxidation in reactor environments, making the study of Zr alloy corrosion behavior crucial for ensuring the safety, longevity, and economic viability of nuclear power systems. While the oxidation behavior of Zr-based cladding materials has been extensively studied since the 1950s, a mechanistic understanding into the relationship between structure evolution, solute element redistribution, and properties remains elusive. Valuable insights may be obtained through advanced experimental methods, such as in-situ and high resolution microscopy techniques. Here, in this study, the oxidation behavior of Zircaloy-4 at 500 °C in O 2 is characterized using a multimodal advanced characterization approach. Using in-situ X-ray diffraction, the phase evolution from metastable to stable oxides is tracked in real time. Complementary high-resolution techniques, including electron microscopy and atom probe tomography, reveal nanoscale insights into the microstructural changes and solute redistribution across the oxide/metal interface. Nanohardness mapping across the oxide/metal interface highlights localized mechanical property variations that may be linked to changes in microstructure and crystal structure within the oxide layer. These findings offer valuable insights into the microstructure and property evolution of Zircaloy-4 during oxidation, contributing to a better understanding of microstructural changes in Zr-based alloys under oxidative environments.

APT↗

Nanoscale phase separation in epitaxial Cr-Mo and Cr-V alloy thin films studied using atom probe tomography: Comparison of experiments and simulation

Tailored metal alloy thin film-oxide interfaces generated using molecular beam epitaxy (MBE) deposition of alloy thin films on a single crystalline oxide substrate can be used for detailed studies of irradiation damage response on the interface structure. However, the presence of nanoscale phase separation in the MBE grown alloy thin films can impact the metal-oxide interface structure. Due to nanoscale domain size of such phase separation, it is very challenging to characterize by conventional techniques. Therefore, laser assisted atom probe tomography (APT) was utilized to study the phase separation in epitaxial Cr{sub 0.61}Mo{sub 0.39}, Cr{sub 0.77}Mo{sub 0.23}, and Cr{sub 0.32}V{sub 0.68} alloy thin films grown by MBE on MgO(001) single crystal substrates. Statistical analysis, namely frequency distribution analysis and Pearson coefficient analysis of experimental data was compared with similar analyses conducted on simulated APT datasets with known extent of phase separation. Thus, the presence of phase separation in Cr-Mo films, even when phase separation was not clearly observed by x-ray diffraction, and the absence of phase separation in the Cr-V film were confirmed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Grazing-Incidence Texture Tomography and Diffuse Reflectivity Tomography of an Organic Semiconductor Device Array

The use of grazing-incidence scattering methods for the characterization of 2D patterned organic thin films is limited due to the elongated 1D footprint of the X-ray beam on the sample. However, this characteristic feature can be turned into an advantage, when combined with tomographic reconstruction. In this pilot study we show, how the use of a chosen texture reflection and a diffuse reflectivity signal can each provide 2D images of the deposits, simultaneously revealing the organic film's crystal orientation and the location of the metal electrodes in a field-effect transistor structure from a single sequence of diffraction images.

36 MATERIALS SCIENCE↗

Microstructure characterization by X-ray tomography and EBSD of porous FeCr produced by liquid metal dealloying

Highlights: • FeCr-Ni precursors were dealloyed in a Mg bath to give FeCr-Mg bicontinuous structure. • FeCr-Mg bicontinuous structure was immersed in HNO{sub 3} solution to get porous FeCr. • (FeCr){sub x}-Ni{sub 1−x} precursors are fully FCC phase while porous FeCr are fully BCC phase. • Composition & dealloying parameters are key parameters for controlling microstructure - Abstract: Liquid metal dealloying is a promising technique to get nanoporous materials which are attractive for their excellent functional properties. From a (FeCr){sub x}-Ni{sub 1−x} precursor, it is possible to get porous FeCr with this technique. While immersing precursors in a molten Mg bath, Ni atoms selectively migrate into the Mg bath. After cooling down to room temperature, the resulting microstructure is a bi-continuous structure of FeCr and Mg (with Ni in solid solution). A final etching step removes the Mg solid-state solution phase. Precursors with different compositions were dealloyed and imaged in 3D. From X-ray tomography images, porous FeCr characteristics as solid fraction, phase size, specific surface were extracted. EBSD maps were acquired on samples before and after dealloying. We will show that precursor composition is a key parameter to control pores and grains size while dealloying parameters (time and temperature) are key parameters to control ligaments size and in fine specific surface. By controlling precursor composition and dealloying parameters it is now possible to get dealloyed nanoporous metals with desired grain and porous microstructure by liquid metal dealloying.

36 MATERIALS SCIENCE↗

In-situ study of the growth of CuO nanowires by energy dispersive X-ray diffraction

Growth of CuO nanowires by annealing method has been studied in-situ by grazing incidence Energy Dispersive X-ray Diffraction (EDXRD) technique on Indus-2. It was observed that Cu slowly oxidized to Cu{sub 2}O and finally to CuO. The data was taken as a function of time at two annealing temperatures 500 Degree-Sign C where nanowires form and 300 Degree-Sign C where nanowires don't form. We found that the strain in the CuO layer may be a principal factor for the spontaneous growth of nanowires in annealing method.

36 MATERIALS SCIENCE↗

Focused Ion Beam Tomography of Alloy 617 Corroded in Molten Chloride Salt

Materials qualification of reactor structural materials is a critical step in rapid implementation of advanced nuclear reactor technologies, particularly to assess the corrosion performance in these designs. Accelerated qualification of reactor structural materials requires incorporating powerful computational toolsets, such as phase field modelling in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, to predict the evolution of structural materials due to corrosion. Accordingly, computational toolsets will require experimental data generated at appropriate length scales to validate accuracy. Focused ion beam (FIB) provides a high degree of control over manipulation of materials for analytical purposes, including capturing data on the evolution in the microstructure and elemental composition of materials at the mesoscale, an appropriate length scale for phase field modelling of intergranular diffusion phenomena using the MOOSE framework. For instance, the FEI Helios G4 UX dual beam plasma FIB microscope at the Irradiated Materials Characterization Laboratory (IMCL) is capable of backscatter diffraction (EBSD) and energy-dispersive x-ray spectroscopy (EDS) documenting the evolution in the microstructure and elemental composition, respectively. The Helios can perform EDS and EBSD three-dimensionally (3D) using tomography, which is then combined using different software packages to visualize 3D volumes correlating elemental composition to microstructural data. The purpose of this investigation was to develop a streamlined characterization and data processing workflow for 3D tomography studies on the FEI Helios G4 plasma FIB. The investigation is segmented into three parts: 1) Optimizing the data collection workflow, 2) identifying appropriate data processing and visualization software (i.e. DREAM.3D, MIPAR, and VGStudioMax), and 3) establishing an infrastructure for public release. The optimization of the data collection workflow is in collaboration with members of the U220 department to setup formal training on the tomography operation of the G4, through ThermoFisher Scientific, and exploring DREAM.3D, MIPAR, and VGStudioMax data processing/visualization software packages. VGStudioMax currently demonstrates the most promise for future use. Optimization of the data collection and processing workflow is still ongoing. A collaboration with INL High Performance Computing (HPC) established an open-source license for expediting the public release of FIB tomography datasets through HPC. FIB tomography data generated by the G4 will provide comprehensive data for validating 3D phase field mesoscale modelling tools within the MOOSE framework for accelerated qualification of reactor structural materials.

Copeland-Johnson, Trishelle↗

Nanometric resolution using far-field optical tomographic microscopy in the multiple scattering regime

The resolution of optical far-field microscopes is classically diffraction-limited to half the illumination wavelength. We show experimentally that this fundamental limit does not apply in the multiple scattering regime. We used tomographic diffractive microscopy at 633 nm to image two pairs of closely spaced rods (with a width and interdistance of 50 nm) of widely different diffractive properties. Using an inversion algorithm accounting for multiple scattering, only the pair of highly diffracting rods could be clearly visualized with a resolution similar to that of an atomic force microscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-09: The Impact of X-Ray Scattering On Image Noise for Dedicated Breast CT

Purpose: To quantify the impact of detected x-ray scatter on image noise in flat panel based dedicated breast CT systems and to determine the optimal scanning geometry given practical trade-offs between radiation dose and scatter reduction. Methods: Four different uniform polyethylene cylinders (104, 131, 156, and 184 mm in diameter) were scanned as the phantoms on a dedicated breast CT scanner developed in our laboratory. Both stationary projection imaging and rotational cone-beam CT imaging was performed. For each acquisition type, three different x-ray beam collimations were used (12, 24, and 109 mm measured at isocenter). The aim was to quantify image noise properties (pixel variance, SNR, and image NPS) under different levels of x-ray scatter, in order to optimize the scanning geometry. For both projection images and reconstructed CT images, individual pixel variance and NPS were determined and compared. Noise measurement from the CT images were also performed with different detector binning modes and reconstruction matrix sizes. Noise propagation was also tracked throughout the intermediate steps of cone-beam CT reconstruction, including the inverse-logarithmic process, Fourier-filtering before backprojection. Results: Image noise was lower in the presence of higher scatter levels. For the 184 mm polyethylene phantom, the image noise (measured in pixel variance) was ∼30% lower with full cone-beam acquisition compared to a narrow (12 mm) fan-beam acquisition. This trend is consistent across all phantom sizes and throughout all steps of CT image reconstruction. Conclusion: From purely a noise perspective, the cone-beam geometry (i.e. the full cone-angle acquisition) produces lower image noise compared to the lower-scatter fan-beam acquisition for breast CT. While these results are relevant in homogeneous phantoms, the full impact of scatter on noise in bCT should involve contrast-to-noise-ratio measurements in heterogeneous phantoms if the goal is to optimize the scanning geometry for dedicated breast CT. This work was supported by a grant from the National Institute for Biomedical Imaging and Bioengineering (R01 EB002138)

60 APPLIED LIFE SCIENCES↗

Using Multiplicative Algebraic Reconstruction Techniques (MART) to Derive Instrument Requirements for Computed Tomography Imaging Spectrographs

Computed Tomography Imaging Spectrographs (CTISs), which are generally slitless or large-aperture spectrographs that observe a wide, dispersed field of view in multiple dispersion angles or diffraction orders, provide a unique opportunity to capture spectral information over an extended source, such as the Sun, but require software reconstruction techniques to be fully utilized. A useful data product that can be recovered from CTIS observations is intensity maps of solar features in single spectral lines. These intensity maps can then be used to determine temperature, density, abundance, and equilibrium properties of the emitting plasma. We apply the multiplicative algebraic reconstruction technique (MART) to example data from a variety of CTIS configurations to determine the capability and limitations of the method to return spectrally-pure maps. By completing this study, we aim to establish a path to derive requirements for CTIS instruments that rely on reconstruction techniques to meet their science objectives.

Amy Winebarger↗