Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Stochastic backgrounds of gravitational waves from cosmological sources: Techniques and applications to preheating

Several mechanisms exist for generating a stochastic background of gravitational waves in the period following inflation. These mechanisms are generally classical in nature, with the gravitational waves being produced from inhomogeneities in the fields that populate the early Universe and not quantum fluctuations. The resulting stochastic background could be accessible to next generation gravitational wave detectors. We develop a framework for computing such a background analytically and computationally. As an application of our framework, we consider the stochastic background of gravitational waves generated in a simple model of preheating.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time In-situ CO 2 Monitoring (RICO2M) Network for Sensitive Subsurface Areas in CCUS

Intelligent Optical Systems (IOS) has developed the Real-Time In-Situ CO 2 Monitoring (RICO2M) system, a fiber optic-based monitoring system capable of the highly sensitive detection of increasing levels of carbon dioxide (CO 2 ) in groundwater. In collaboration with the Bureau of Economic Geology at the University of Texas at Austin, IOS performed multiple field deployments and validation studies of an in-situ real-time monitoring network. We have developed and demonstrated a multi-channel instrument capable of covering up to eight water wells, with a fabrication cost of ~$5,000, which compares very favorably with existing fiber optic monitoring instrumentation for downhole monitoring. Numerous field studies demonstrated the ability of the RICO2M system to detect small leaks of CO 2 reaching aquifers, and the capacity of the sensor probe to operate for at least one year before replacement. The final system design was a sensitive CO 2 leak detector; further development will be necessary to accurately quantify and monitor CO 2 concentrations in real time.

54 ENVIRONMENTAL SCIENCES↗

Development of Interconnect Technologies for Particle Detectors

This final report covers the three years of this grant, for the funding period 9/1/2010 - 8/31/2013. The project consisted of generic detector R&D work at UC Davis, with an emphasis on developing interconnect technologies for applications in HEP. Much of the work is done at our Facility for Interconnect Technologies (FIT) at UC Davis. FIT was established using ARRA funds, with further studies supported by this grant. Besides generic R&D work at UC Davis, FIT is engaged in providing bump bonding help to several DOE supported detector R&D efforts. Some of the developmental work was also supported by funding from other sources: continuing CMS project funds and the Linear Collider R&D funds. The latter program is now terminated. The three year program saw a good deal of progress on several fronts, which are reported here.

43 PARTICLE ACCELERATORS↗

Design and implementation of an array of micro-electrochemical detectors for two-dimensional liquid chromatography-proof of principle

Simultaneous two-dimensional liquid chromatography (2D-LC) is an implementation of two-dimensional liquid chromatography which has the potential to provide very fast, yet highly efficient separations. It is based on the use of time x space and space x space separation systems. The basic principle of this instrument has been validated long ago by the success of two-dimensional thin layer chromatography. The construction of a pressurized wide and flat column (100 mm x 100 mm x 1 mm) operated under an inlet pressure of up to 50 bar was described previously. However, to become a modern analytical method, simultaneous 2D-LC requires the development of detectors suitable for the monitoring of the composition of the eluent of this pressurized planar, wide column. An array of five equidistant micro-electrochemical sensors was built for this purpose and tested. Each sensor is a three-electrode system, with the working electrode being a 25 {micro}m polished platinum micro-electrode. The auxiliary electrode is a thin platinum wire and the reference electrode an Ag/AgCl (3 M sat. KCl) electrode. In this first implementation, proof of principle is demonstrated, but the final instrument will require a much larger array.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time Radiative Divertor Feedback Control Development for the NSTX-U Tokamak using a Vacuum Ultraviolet Spectrometer

A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature Te estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the delta n=0;1 line intensity ratios of carbon, nitrogen or neon ions lines in the spectral range 300 to 1600 A. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time Te-dependent signal within a characteristic divertor detachment equilibration time of ~ 10 -15 ms is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identification and mitigation of memory block timing issue in ITk ABCStar during ASIC production

The ABCStar is a mixed-signal front-end readout ASIC for the strips sensor portion of the ATLAS ITk detector being developed as part of the High-Luminosity LHC upgrade. In pre-production testing, a subtle design flaw was uncovered in the ABCStar that was reducing wafer yields in some manufactured lots from the expected 90% to as low as 2%. The root cause was determined to be a timing issue in the logic synthesized to control previously silicon proven memory blocks re-used for this ASIC. The solutions proposed included manufacturing process changes by the wafer foundry, changes to the operating parameters for the ABCStar in the detector, and the possibility that a redesign might be required. The two mitigation efforts were undertaken in parallel, with the process modification route a less desirable solution since already manufactured wafers would need to be scrapped in favour of the new ones. Based on a knowledge of the existing process, and testing done on the worst performing wafers, it was proposed that raising the core operating voltage of the ABCStar from 1.20V to 1.25V could address the timing issue by sufficiently speeding up its transistors. An extensive testing program that included the effects of temperature and radiation expected over the lifetime of the ITk detector was conducted to validate that approach. Those tests and studies proved that even the worst performing wafers would have yields over 80% with the 1.25V core voltage, and neither the modified process nor redesign would be required for ensuring reliable operation of the ITk. Based on testing, a further timing mitigation was implemented to provide an additional margin of reliability by increasing the duty cycle of the clock to the ABCStar. Testing of all ABCStar wafers has been completed and the production of the detector modules using these ASICs is now well underway as a result of the efforts detailed herein.

FOS: Physical sciences↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

A Prototype Large Area Detector Module for Muon Scattering Tomography

Abstract-Shielded special nuclear materials (SNM) are of concern as some fissile isotopes have low gamma and neutron emission rates. These materials are also easily shielded to the point where their passive emissions are comparable to background. Consequently, shielded SNM is very challenging for passive radiation detection portals which scan cargo containers. One potential solution for this is to utilise the natural cosmic ray muon background and examine how these muons scatter from materials inside the container volume, terms; the muon scattering tomography (MST) technique measures the three-dimensional localised scattering at all points within a cargo container, providing a degree of material discrimination. There is the additional benefit that the MST signal increases with the presence of more high density shielding materials, in contrast to passive radiation detection. Simulations and calculations suggest that the effectiveness of the technique is sensitive to the tracking accuracy amongst other parameters, motivating the need to develop practical detector systems that are capable of tracking cosmic ray muons. To this end, we have constructed and tested a 2 m by 2 m demonstration module based on gaseous drift chambers and triggered by a large area scintillator-based detector, which is readout by wavelength shifting fibres. We discuss its design, construction, characterisation and operational challenges. (authors)

42 ENGINEERING↗

An atom trap trace analysis system for measuring krypton contamination in xenon dark matter detectors

We have developed an atom trap trace analysis (ATTA) system to measure Kr in Xe at the part per trillion (ppt) level, a prerequisite for the sensitivity achievable with liquid xenon dark matter detectors beyond the current generation. Since Ar and Kr have similar laser cooling wavelengths, the apparatus has been tested with Ar to avoid contamination prior to measuring Xe samples. A radio-frequency plasma discharge generates a beam of metastable atoms which is optically collimated, slowed, and trapped using standard magneto-optical techniques. Based on the measured overall system efficiency of 1.2 × 10{sup −8} (detection mode), we expect the ATTA system to reach the design goal sensitivity to ppt concentrations of Kr in Xe in <2 h.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian Estimator for Angle Recovery: Event Classification and Reconstruction in Positron Emission Tomography

PET at the highest level is an inverse problem: reconstruct the location of the emission (which localize biological function) from detected photons. Ideally, one would like to directly measure an annihilation photon's incident direction on the detector. In the developed algorithm, Bayesian Estimation for Angle Recovery (BEAR), we utilized the increased information gathered from localizing photon interactions in the detector and developed a Bayesian estimator for a photon's incident direction. Probability distribution functions (PDFs) were filled using an interaction energy weighted mean or center of mass (COM) reference space, which had the following computational advantages: (1) a significant reduction in the size of the data in measurement space, making further manipulation and searches faster (2) the construction of COM space does not depend on measurement location, it takes advantage of measurement symmetries, and data can be added to the training set without knowledge and recalculation of prior training data, (3) calculation of posterior probability map is fully parallelizable, it can scale to any number of processors. These PDFs were used to estimate the point spread function (PSF) in incident angle space for (i) algorithm assessment and (ii) to provide probability selection criteria for classification. The algorithm calculates both the incident {theta} and {phi} angle, with {approx}16 degrees RMS in both angles, limiting the incoming direction to a narrow cone. Feature size did not improve using the BEAR algorithm as an angle filter, but the contrast ratio improved 40% on average.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of {sup 17}F+p reactions at RESOLUT

The {sup 14}O({alpha},p){sup 17}F reaction is important for understanding the {alpha}p process that occurs in X-ray bursts, but the rate of this reaction remains uncertain due to the uncertain properties of states in {sup 18}Ne. We measured the {sup 17}F(p,p){sup 17}F and {sup 17}F(p,{alpha}){sup 14}O reactions to study the properties of states in {sup 18}Ne that are important for the {sup 14}O({alpha},p){sup 17}F reaction using {sup 17}F radioactive beams from the RESOLUT facility at Florida State University. Double-sided silicon strip detectors were used to detect light particles, and recoiling heavy ions were detected in coincidence using a gas ionization chamber at forward angles. The performance of the system was first tested using the {sup 17}O(p,{alpha}){sup 14}N reaction. This was the first measurement using the ASIC electronics and recoil detector being developed for the Array for Nuclear Astrophysics Studies with Exotic Nuclei (ANASEN). We report on the performance and preliminary results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Contact-Free Germanium Ionization and Phonon Detectors

A new method to study the origin of the dead-layer in ionization-phonon detectors was developed wherein the ionization is measured via a 25 micron gap between the collection electrodes and germanium absorber. Phonon signals are measured with small tungsten thermometers (Tc{approx}90 mK) varnished to the Ge substrates. The Ge samples were studied using collimated {sup 241}Am sources. With this geometry, different contributions to the 'dead-layer' effect can be studied independently: Carrier back diffusion, trapping on surface states, Schottky barrier lowering, etc.

36 MATERIALS SCIENCE↗

Investigation of Charge Transport Properties of CdZnTe Detectors with Synchrotron X-ray Radiation

Various internal defects, such as Te inclusions, twin boundaries, dislocation, etc., are prevalent in as-grown CdZnTe (CZT) crystals, which affect the charge transport properties of CZT crystals and, therefore, worsen the performance of CZT detectors. In order to develop high quality CZT detectors, it is imperative to clarify the effects of internal defects on the charge transport properties of CZT. Simple flood illumination with nuclear radiation source cannot reveal the nature of highly localized defects in CZT. Therefore, at Brookhaven's National Synchrotron Light Source (NSLS), we have developed a unique testing system for micro-scale defect investigation of CZT, which employs an X-ray beam collimated with the spatial resolution as small as 3 x 3 {micro}m{sup 2}, a microscopic size comparable to the scale of common defects in CZT. This powerful tool enables us to investigate the effect of internal defects on charge transport properties of CZT in detail.

43 PARTICLE ACCELERATORS↗

Optical fiber evanescent wave adsorption sensors for high-temperature gas sensing in advanced coal-fired power plants

Modern advanced energy systems such as coal-fired power plants, gasifiers, or similar infrastructure present some of the most challenging harsh environments for sensors. The power industry would benefit from new, ultra-high temperature devices capable of surviving in hot and corrosive environments for embedded sensing at the highest value locations. For these applications, we are currently exploring optical fiber evanescent wave absorption spectroscopy (EWAS) based sensors consisting of high temperature core materials integrated with novel high temperature gas sensitive cladding materials. Mathematical simulations can be used to assist in sensor development efforts, and we describe a simulation code that assumes a single thick cladding layer with gas sensitive optical constants. Recent work has demonstrated that Au nanoparticle-incorporated metal oxides show a potentially useful response for high temperature optical gas sensing applications through the sensitivity of the localized surface plasmon resonance absorption peak to ambient atmospheric conditions. Hence, the simulation code has been applied to understand how such a response can be exploited in an optical fiber based EWAS sensor configuration. We demonstrate that interrogation can be used to optimize the sensing response in such materials.

01 COAL, LIGNITE, AND PEAT↗

The cluster charge identification in the GEM detector for fusion plasma imaging by soft X-ray diagnostics

The measurement system based on gas electron multiplier detector is developed for soft X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for estimation of the energy and the position distribution of an X-ray source. The focal measuring issue is the charge cluster identification by its value and position estimation. The fast and accurate mode of the serial data acquisition is applied for the dynamic plasma diagnostics. The charge clusters are counted in the space determined by 2D position, charge value, and time intervals. Radiation source characteristics are presented by histograms for a selected range of position, time intervals, and cluster charge values corresponding to the energy spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of m.w.e (meter water equivalent) depth of the salt mine of Slanic Prahova, Romania

A new mobile detector was developed in IFIN-HH, Romania, for measuring muon flux at surface and in underground. The measurements have been performed in the salt mines of Slanic Prahova, Romania. The muon flux was determined for 2 different galleries of the Slanic mine at different depths. In order to test the stability of the method, also measurements of the muon flux at surface at different altitudes were performed. Based on the results, the depth of the 2 galleries was established at 610 and 790 m.w.e. respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metrological Determination of Natural Radioactive Isotopes {sup 226}Ra, {sup 228}Ra and {sup 210}Pb by Means of Ge Detector

A metrological method to determine the activity per mass unity (activity concentration) of {sup 226}Ra and {sup 210}Pb ({sup 238}U decay series) and {sup 228}Ra ({sup 232}Th series) by gamma-ray spectrometers based on hyper-pure coaxial germanium detector was developed. In the soil the {sup 22}Ra (half-life = 1600 years) exhibits the same level of radioactivity as {sup 238}U (half-life 4.5x10{sup 9} years) because of a natural phenomenon called secular equilibrium. {sup 226}Ra decays into {sup 222}Rn (half-life = 3.8 days), a radioactive inert gas. After several days, the {sup 222}Rn naturally decays to {sup 218}Po (half-life = 3 minutes), where finally {sup 210}Pb (half-life = 22 years) is produced. The metrological capability of high-resolution gamma-ray spectrometry for naturally occurring radionuclides at environmental levels is showed, with emphasis on the use of 2 mL standard sources volume in a glass ampoule. Source preparation and calibration procedures are described. Radionuclide standards in an activity range of 10 to 250 Bq/g were produced which can be applied in a variety of environmental sample analysis (water, plant material, sediment, etc.). Uncertainties for {sup 226}Ra and {sup 210}Pb around 3% (k = 1) were obtained.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Phoswich and ARSA-type detectors for Radioxenon Measurements

The monitoring of atmospheric radioxenon to ensure compliance with the Comprehensive Nuclear Test Ban Treaty has driven the development of improved detectors for measuring xenon, including the development of a phoswich detector. This detector uses only one PMT to detect beta-gamma coincidence, thus greatly reducing the bulk and electronics of the detector in comparison to the ARSA-type detector. In this experiment, 135Xe was produced through neutron activation and a phoswich detector was used to attain spectra from the gas. These results were compared to similar results from an ARSA-type beta-gamma coincidence spectrum. The spectral characteristics and resolution were compared for the coincidence and beta spectra. Using these metrics, the overall performance of the phoswich detector for beta-gamma coincidence of radioxenon was evaluated.

ARSA↗