At least 433 records · Page 24

A Polarimeter for SOFIA: Summary of Research

The purpose of this research was to study designs for a far-infrared polarimeter for SOFIA that would greatly surpass the performance of the earlier polarimeter, Stokes, used on the Kuiper Airborne Observatory. Specifically we wished to gain the sensitivity to observe much fainter objects, to provide a choice of passbands, to reduce systematic errors, and to improve the efficiency. All of these objectives were successfully addressed. The gain in sensitivity will be achieved in part by the superior capabilities of SOFIA but to an even greater extent by the incorporation of new-technology detector arrays. We are developing superconducting transition-edge detectors using the "pop-up" design conceived by Dr. Harvey Moseley. The choice of passbands is achieved by providing three alternative optical paths, each with its own spectral filter, half-wave plate, and pupil tens. A new investigation has shown that multiwavelength observations provide an essential feature of far-infrared polarimetry. The principal source of systematic errors in observations of extended objects has been unknown polarization in the reference beams. We have developed a strategy for estimating these errors.

Hildebrand, Roger H.↗

Large-format high resolution microchannel plate detectors for ultraviolet astronomy

This report includes work on two types of two-dimensional position-sensitive detectors that were developed in this lab under this award. We worked to develop and optimize the wire-wound helical delay line detector (HDL) in the first and second years. Some early work on the HDL is contained in a paper included as Appendix A. In the second and third years we developed the concept for, then successfully designed and tested, both a lab prototype, and a flight prototype of the first, crossed delay line detector based on two orthogonal serpentine delay lines (SDL). Some of the work on the SDL is contained in a paper included as Appendix B. Appendix C contains copies of the invention report and record.

Martin, Christopher↗

Development of a Hybrid Gas Detector/Phoswich for Hard X-Ray Astronomy

A hybrid detector is under development for use as a balloon-borne instrument in hard x-ray astronomy. The detector provides broad band coverage by coupling an optical avalanche chamber to a phoswich. The optical avalanche chamber yields superior instrument response at low energies while the scintillator takes over at the higher energies where the gas becomes transparent: at 25 keV, the addition of the gas chamber improves the energy resolution by a factor of 2.5 and the spatial resolution by a factor of 10 as compared to the stand-alone response of the phoswich. A half-scale prototype instrument is being constructed for test purposes and to help resolve a number of design questions involving the coupling of the two components.

Pimperl, M. M.↗

Low background IR detector and detector array evaluations

A technology program has been underway at Ames since 1978 to develop and evaluate detectors and integrated detector arrays for low-background astronomical applications. The approach is to evaluate existing (less than 24 micron) array technology under low-background conditions, with the aim of adapting and optimizing existing devices. For longer wavelengths, where the technology is much less mature, development is sponsored and devices are evaluated, in both discrete and array formats, for eventual applications. The status of this program has been reported previously. We rely on industrial and university sources for the detectors. Typically, after a brief functionality check in the supplier's laboratory, we work with the device at Ames to characterize its low-background performance. In the case of promising arrays or detectors, we conduct ground-based telescope testing to face the problems associated with real applications. A list of devices tested at Ames is given. In the array category, accumulation-mode charge-injection-devices (AMCIDs) appear repeatedly; this reflects our recent experience with the 2 x 64 and 16 x 16 arrays. Results from the 1 x 16 CID and InSb CCD have been reported. The status of our tests of the discrete Ge:x detectors from Lawrence Berkeley Laboratory are described below. Tests of a 1 x 2 switched sample photoconductor array are just beginning. A 32-channel CMOS multiplexer has been tested at 10 K. Low-temperature silicon MOSFETs and germanium JFETs have also been tested, primarily at Ball Aerospace. This paper describes results to date on three elements of this program: AMCID array, discrete Ge:Ga detectors, and Ge JFET preamplifiers.

Goebel, J. H.↗

Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-infrared wavelength bands. Our system retains much of the core signal processing architecture from the first generation system but with a significantly higher bandwidth, enabling the readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 GHz–8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below −30 dBc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Short Wavelength Infrared Array Detectors for Space Astronomy Application

The Smithsonian Astrophysical Observatory (SAO) and its team - the University of Arizona (UA), the University of Rochester (UR), Santa Barbara Research Center (SBRC), Ames Research Center (ARC), and Goddard Space Flight Center (GSFC) - are carrying out a research program with the goal of developing and optimizing infrared arrays in the 2-27 micron range for space infrared astronomy. This report summarizes research results for the entire grant period 1 January 1992 through 30 June 1996.

Fazio, Giovanni G.↗

Generation of Synthetic Data for a Radiation Detection Algorithm Competition

This paper details the generation of synthetic radiation data using large-scale Monte Carlo transport models to evaluate radiation search detection algorithms. Modular 3-D Monte Carlo models spanning multiple city blocks were constructed, loosely based on downtown Knoxville, TN, containing buildings composed of multiple materials (brick, granite, and concrete), sidewalks, a four-lane road, side streets, parking lots, and grassy fields. Background and simulated source detector response calculations from these models were used to create synthetic list mode data sets for a 2"×4"×16" NaI(Tl) detector moving through a city street at a constant speed. For the background simulations, major isotopes were computed individually so that background composition and variability could be computed efficiently outside Monte Carlo. The source detector response included six simulated sources placed at 15 source locations. Detector response was developed to be periodic through the city street so that a detector path could begin at one end of the model and wrap around to the other. This framework allowed for the creation of diverse data sets, each with its own unique background and simulated source detector response. Synthetic data allows for high-quality labels, which are useful in developing data-driven radiation detection algorithms. This methodology was used to create synthetic data sets which were released as part of a public data competition to spur the development of new radiation detection algorithms for radiological search applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

Goetz, Callie↗

Development of a Fast-Spectrum Self-Powered Neutron Detector for Molten Salt Experiments in the Versatile Test Reactor

Abstract—The self-powered neutron detector (SPND) is a widely used flux monitor in thermal nuclear reactors. Although this is a mature technology, the current state of the art is tuned for a thermal neutron spectrum, so many of the devices currently in use lack sensitivity to fast neutrons. Because current in SPNDs is produced through nuclear reactions with the neutron flux inside a reactor, sensitivity in SPNDs is determined by the neutron cross section of the neutron-sensitive portion of the detector, termed the emitter. This neutron cross section drops by orders of magnitude between thermal and fast neutron energies for many emitters in currently used SPNDs, with a corresponding drop in current from the detector. This paper discusses efforts to develop a fast-spectrum self-powered neutron detector (FS-SPND) that is sensitive to neutrons with energies ranging from 0.025 eV up to 1 MeV. An in-depth analysis of Evaluated Nuclear Data File (ENDF)/B-VII.1 neutron-capture cross sections was performed, and four new materials were identified that are suitable emitter candidates for use in measuring fast neutrons. All four materials are stable mid-shell nuclei in the region between doubly magic 132Sn and 208Pb. Each candidate was simulated with the Geant4 Monte Carlo simulation toolkit to optimize overall detector efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of a (Hg, Cd)Te photodiode detector, Phase 2

High speed sensitive (Hg,Cd)Te photodiode detectors operating in the 77 to 90 K temperature range have been developed for the 10.6 micron spectral region. P-N junctions formed by impurity (gold) diffusion in p-type (Hg, Cd) Te have been investigated. It is shown that the bandwidth and quantum efficiency of a diode are a constant for a fixed ratio of mobility/lifetime ratio of minority carriers. The minority carrier mobility and lifetime uniquely determine the bandwidth and quantum efficiency and indicate the shallow n on p (Hg,Cd) Te diodes are preferable as high performance, high frequency devices.

Source record↗

Monolithic short wave infrared (SWIR) detector array

A monolithic self-scanned linear detector array was developed for remote sensing in the 1.1- 2.4-micron spectral region. A high-density IRCCD test chip was fabricated to verify new design approaches required for the detector array. The driving factors in the Schottky barrier IRCCD (Pdsub2Si) process development are the attainment of detector yield, uniformity, adequate quantum efficiency, and lowest possible dark current consistent with radiometric accuracy. A dual-band module was designed that consists of two linear detector arrays. The sensor architecture places the floating diffusion output structure in the middle of the chip, away from the butt edges. A focal plane package was conceptualized and includes a polycrystalline silicon substrate carrying a two-layer, thick-film interconnecting conductor pattern and five epoxy-mounted modules. A polycrystalline silicon cover encloses the modules and bond wires, and serves as a radiation and EMI shield, thermal conductor, and contamination seal.

Source record↗

Stressed detector arrays for airborne astronomy

The development of stressed Ge:Ga detector arrays for far-infrared astronomy from the Kuiper Airborne Observatory (KAO) is discussed. Researchers successfully constructed and used a three channel detector array on five flights from the KAO, and have conducted laboratory tests of a two-dimensional, 25 elements (5x5) detector array. Each element of the three element array performs as well as the researchers' best single channel detector, as do the tested elements of the 25 channel system. Some of the exciting new science possible with far-infrared detector arrays is also discussed.

Stacey, G. J.↗

Advances in Detector Technology for Infrared Astronomy

Progress in semiconductor materials and processing technology has allowed the development of infrared detector arrays with unprecedented sensitivity, for imaging and spectroscopic applications in astronomy. The earlier discrete-detector approach has been replaced by large-element (up to 1024 x 1024 pixel), multiplexed devices. Progress has been made against a number of key limiting factors, such as quantum efficiency, noise, spectral response, linearity, and dark current. Future developments will focus on the need for even larger arrays, which operate at higher temperatures.

McCreight, Craig↗

The development of a high energy cosmic ray detector for Spacelab-2

A large cosmic ray detector aimed at measurements of the energy spectra and of the elemental abundances of cosmic ray nuclei at very high energies, up to several TeV/nucleon was constructed. The instrument is an electronic counter telescope with a geometric factor of 5 sq ster. It accomplishes measurements of the particle energies through the use of gas Cerenkov counters and of transition radiation detectors. The solutions of a number of technological problems that are encountered when developing such instrumentation for Shuttle missions are discussed.

Lheureux, J.↗

Instrumentation for infrared astronomy

During the last 10 years, infrared astronomy, based on observations in the wavelength range from 2 to 1000 micrometers, has become a major field of observational astrophysics. This development is mainly related to two major technical advances. Extremely sensitive detectors have been developed and become available for astronomical applications. Motivated by the first development, major groups have expended much effort in building and operating telescopes above most or all of the earth's atmosphere in order to circumvent its opacity and emission throughout the range. Attention is given to advances in the area of infrared detectors, platforms for infrared astronomy, focal plane instruments, high spatial resolution instrumentation, and infrared polarization measurements.

Soifer, B. T.↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-latency NuMI Trigger for the CHIPS-5 Neutrino Detector

The CHIPS R&D project aims to develop affordable water Cherenkov detectors for large-scale underwater installations. In 2019, a 5kt prototype detector CHIPS-5 was deployed in northern Minnesota to study neutrinos generated by the nearby NuMI beam. This contribution presents a dedicated low-latency time distribution system for CHIPS-5 that delivers timing signals from the Fermilab accelerator to the detector with sub-nanosecond precision. Exploiting existing NOvA infrastructure, the time distribution system achieves this only with open-source software and conventional network elements. In a time-of-flight study, the presented system has reliably offered a time budget of $610 \pm 330\text{ ms}$ for on-site triggering. This permits advanced analysis in real-time as well as a novel hardware-assisted active triggering mode, which reduces DAQ computing load and network bandwidth outside triggered time windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Repair and Utilization of the Kratos XSAM 800 X-Ray Photoelectron Spectrometer (XPS)

The objectives for this summer faculty fellowship were first to repair the Kratos XSAM 800 X-ray Photoelectron Spectrometer (XPS) and then to utilize the instrument to participate in ongoing research projects at KSC and in the researcher's own laboratory at UCF. The first 6 weeks were used in repairing the instrument. Working both alone and with the Kratos service engineer, a number of hardware problems, largely associated with the sample stage control system, were corrected. Defective parts were identified and fixed in the computer driver boards, the stage power supply, and the driver interface. The power supply was completely replaced. After four weeks of work, the instrument was functional. This occurred on a Wednesday. The following Friday the instrument had to be completely shut down because the power to the O & C Building was to be turned off. The instrument was properly secured. On Monday, the instrument was powered up and the original problems returned. After another 2 weeks of work, a software problem was identified. This problem caused the computer to use a defective port for the sample stage control. It was circumvented by rewriting the startup routine. The final 3 weeks of the fellowship were spent using the XPS to analyze samples being studied in the Langley materials project (Martha Williams) and a catalyst project (Dr. Orlando Melendez). During this time, several sample analysis requests from other groups at KSC also came in and those samples were run as well. The summer faculty fellowship also allowed many contacts to be made. After meeting with the sensors group, two projects were identified for collaboration and white papers are being prepared. One project aims to develop small, very sensitive hydrogen detectors and the other to develop a broad area, easily monitored, zero power consumption hydrogen detector. In addition to the work mentioned above, the XPS was utilized in a study underway in Dr. Hampton's laboratory at UCF.

Hampton, Michael D.↗