Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “design loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Highly Loaded Low Pressure Turbine (LPT)

The goal of this study is to evaluate aspirated and non-aspirated aerodynamics on highly loaded LPT design. The objective is to increase stage loading by 30 to 50 percent without loss of efficiency for an existing low pressure turbine design. A study conducted on a NASA highly loaded multistage fan drive turbine (NASA CR-1964) indicated that end-wall bleed at the hub is a more significant parameter compared to aspirated airfoil. Based on this study, a 3-stage LPT is redesigned to 2-stage LIT with and without end-wall bleed. Both aerodynamic design and mechanical design are completed. In addition to end-wall bleed, exit guide vanes are designed with aspirated airfoils to reduce the losses. The LPT is redesigned with all constraints necessary for practical application. The benefit of the high-performance, highly loaded LPT shows up in reduced stage and part count, reduced size and weight, and reduced cost.

Ortiz, Milt↗

An improved method for optimum design of mechanically and thermally loaded structures

The problem of obtaining the minimum-mass design of mechanically and thermally loaded structures is presented. The special nature of thermal stresses with regard to their response to resizing of structural members is discussed. It is shown that conventional resizing procedures which are based on driving the total stress to its allowable value may be inefficient when the thermal stress in an element makes up a significant fraction of the total stress. An improved algorithm for resizing of structures subjected to thermal stresses is treated. In this algorithm the mechanical portions of the stresses were driven to their maximum allowable values. The thermal stresses were used to adjust the allowable values of the mechanical stresses. The new algorithm was exercised for a number of truss structures of varying complexity and compared with ordinary fully stressed design.

Adelman, H. M.↗

Loads Combination Research at Marshall Space Flight Center

This is the result of a study conducted by the Structural Dynamics Division of the Marshall Space Flight Center concerning the combination of low- and high-frequency dynamic loads for spacecraft design. Low-frequency transient loads are combined with high frequency acoustically induced loads to arrive at a limit load, for design purposes. Different methods are used for combining the loads which can lead to considerable variation in limit loads, depending on which NASA Center did the calculation. This study investigates several different combination methods and compares the combination methods with Spacelab 1 flight data. In addition, the relative timing of low- and high-frequency loads is examined.

Ferebee, R.↗

Loads Combination Research at Marshall Space Flight Center

This is the result of a study conducted by the Structural Dynamics Division of the Marshall Space Flight Center concerning the combination of low- and high-frequency dynamic loads for spacecraft design. Low-frequency transient loads are combined with high frequency acoustically induced loads to arrive at a limit load, for design purposes. Different methods are used for combining the loads which can lead to considerable variation in limit loads, depending on which NASA Center did the calculation. This study investigates several different combination methods and compares the combination methods with Spacelab 1 flight data. In addition, the relative timing of low- and high-frequency loads is examined.

Ferebee, R.↗

Design curves for non-linear analysis of simply-supported, uniformly-loaded rectangular plates

Design curves for the non-linear analysis of simply-supported rectangular plates subjected to uniform normal pressure loads have been developed. These curves yield the center deflection, center stress and corner stress in non-dimensionalized form plotted against a dimensionless parameter describing the load intensity. The results presented are based on extensive non-linear finite element analysis employing the ARGUS structural analysis program. Plates with length to width ratios of 1, 1.5, 2, 3 and 4 are included. The load range considered extends to 1000 times the load at which the behavior of the plate becomes significantly non-linear. Over the load range considered, the analysis shows that the ratio of center deflection to plate thickness for a square plate is less than 16 to 1, whereas linear theory would predict a center deflection 400 times the plate thickness. Likewise, the stress is markedly lower than would be predicted by linear theory. The present results are shown to be in excellent agreement with the classical linear theory up to a central deflection to plate thickness ratio of about one-half. In the non-linear regime the present results for deflection and stress are in very good agreement with the analytical and experimental work of other investigators.

Moore, D.↗

Structural Sizing of the EDIN0620 Body Components Using the APAS Structural Synthesis Computer Program

The use of a structural synthesis computer program to design components for a heavy lift launch vehicle is defined. A loads program was used to determine the vehicle shears, bending moments, and axial loads at two design loading conditions. A comparison was made between results from the structures program and the results of a weight estimating program which used historical data in determining component weights.

Nolte, W. E.↗

Implications of carbon cap-and-trade for electricity rate design, with examples from Florida

The price of CO{sub 2} emissions allowances affects the structure of the utility's costs, which has implications for rate design and load management programs. Depending on the design of the program to recover these costs, utility total revenue requirements - and the rate design utilized to recover these requirements - may be impacted. A new way to think about rate design may be required. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

Extension-twist coupling of composite circular tubes with application to tilt rotor blade design

This investigation was conducted to determine if twist deformation required for the design of full-scale extension-twist-coupled tilt-rotor blades can be achieved within material design limit loads, and to demonstrate the accuracy of a coupled-beam analysis in predicting twist deformations. Two extension-twist-coupled tilt-rotor blade designs were developed based on theoretically optimum aerodynamic twist distributions. The designs indicated a twist rate requirement of between .216 and .333 deg/in. Agreement between axial tests and analytical predictions was within 10 percent at design limit loads. Agreement between the torsion tests and predictions was within 11 percent.

Nixon, Mark W.↗

Deformed Shape Calculation of a Full-Scale Wing Using Fiber Optic Strain Data from a Ground Loads Test

A ground loads test of a full-scale wing (175-ft span) was conducted using a fiber optic strain-sensing system to obtain distributed surface strain data. These data were input into previously developed deformed shape equations to calculate the wing s bending and twist deformation. A photogrammetry system measured actual shape deformation. The wing deflections reached 100 percent of the positive design limit load (equivalent to 3 g) and 97 percent of the negative design limit load (equivalent to -1 g). The calculated wing bending results were in excellent agreement with the actual bending; tip deflections were within +/- 2.7 in. (out of 155-in. max deflection) for 91 percent of the load steps. Experimental testing revealed valuable opportunities for improving the deformed shape equations robustness to real world (not perfect) strain data, which previous analytical testing did not detect. These improvements, which include filtering methods developed in this work, minimize errors due to numerical anomalies discovered in the remaining 9 percent of the load steps. As a result, all load steps attained +/- 2.7 in. accuracy. Wing twist results were very sensitive to errors in bending and require further development. A sensitivity analysis and recommendations for fiber implementation practices, along with, effective filtering methods are included

Jutte, Christine V.↗

Improved Benchmarking of Cohesive Elements in Abaqus Standard for Predicting Disbond and Delamination in Composite Structures

Traditional approaches for aircraft certification require the assumption of an initial flaw condition, either represented as barely visible impact damage (BVID) or through inclusion of a Teflon insert to serve as surrogate damage. Based on the initial composite damage state, the structure must be shown to demonstrate structural durability and damage tolerance (DaDT) according to the following criteria: a. Damage displays no detrimental growth under cyclic loading. The structure is able to sustain design limit load (DLL). Currently, the only available manner for validating structural performance is through test. Since damage can occur over a wide variety of areas within a structure, this approach has proven to be increasingly expensive and time consuming for composite airframes and acreage structure within the design-test-certification building block. A further complicating factor is the requirement to accurately capture the most critical damage morphologies as a starting condition. To understand the severity of the damage, it is either required to experimentally determine the most critical areas at tremendous expense or rely on legacy data of similar structural testing, which limits design space expansion. A preferred solution is to use advanced analysis to provide improved understanding of load margins for critical locations based on a wide variety of potential starting damage conditions.

Eric M. Roberts↗

Preliminary analysis of the span-distributed-load concept for cargo aircraft design

A simplified computer analysis of the span-distributed-load airplane (in which payload is placed within the wing structure) has shown that the span-distributed-load concept has high potential for application to future air cargo transport design. Significant increases in payload fraction over current wide-bodied freighters are shown for gross weights in excess of 0.5 Gg (1,000,000 lb). A cruise-matching calculation shows that the trend toward higher aspect ratio improves overall efficiency; that is, less thrust and fuel are required. The optimal aspect ratio probably is not determined by structural limitations. Terminal-area constraints and increasing design-payload density, however, tend to limit aspect ratio.

Whitehead, A. H., Jr.↗

Cold-air investigation of a 31/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 2: Performance of 2-, 3- and 3 1/2-stage configurations

The stage work distribution among the three stages was very close to the design value. The specific work output-mass flow characteristics of the three stages were closely matched. The efficiency of the 3 1/2 stage turbine at design specific work output and design speed was within 0.008 of the estimated value, and this agreement was felt to demonstrate the adequacy of the prediction method in the high stage loading factor regime.

Whitney, W. J.↗

Enhancements in Glovebox Design Resulting from Laboratory-Conducted FIre Tests

The primary mission of the Pit Disassembly and Conversion Facility (PDCF) Project was to disassemble nuclear weapons pits and convert the resulting special nuclear materials to a form suitable for further disposition. Because of the nature of materials involved, the fundamental system which allowed PDCF to perform its mission was a series of integrated and interconnected gloveboxes which provided confinement and containment of the radioactive materials being processed. The high throughput planned for PDCF and the relatively high neutron and gamma radiation levels of the pits required that gloveboxes be shielded to meet worker dose limits. The glovebox shielding material was required to contain high hydrogen concentrations which typically result in these materials being combustible. High combustible loadings created design challenges for the facility fire suppression and ventilation system design. Combustible loading estimates for the PDCF Plutonium (Pu) Processing Building increased significantly due to these shielding requirements. As a result, the estimates of combustible loading substantially exceeded values used to support fire and facility safety analyses. To ensure a valid basis for combustible loading contributed by the glovebox system, the PDCF Project funded a series of fire tests conducted by the Southwest Research Institute on door panels and a representative glovebox containing Water Extended Polyester (WEP) radiological shielding to observe their behavior during a fire event. Improvements to PDCF glovebox designs were implemented based on lessons learned during the fire test. In particular, methods were developed to provide high levels of neutron shielding while maintaining combustible loading in the glovebox shells at low levels. Additionally, the fire test results led to design modifications to mitigate pressure increases observed during the fire test in order to maintain the integrity of the WEP cladding. These changes resulted in significantly reducing the credited combustible loading of the facility. These advances in glovebox design should be considered for application in nuclear facilities within the Department of Energy complex in the future.

Brooks, Kriston P.↗

A Deterministic and Probabilistic Framework for Forecasting of Time-Series Damage States and Associated End-of-lIfe of a Pressurizer Water Reactor Surge Line under Design-Basis and Grid-Load-Following Loading Conditions

Argonne National Laboratory in support of the Department of Energy’s Light Water Reactor Sustainability (LWRS) program. The present semi-annual report covers the period between May 2018 and September 2018. In this report, we present the work performed to further improve the capability for structural integrity prediction. Part of this work focused on validating a computational fluid dynamics model for modeling thermal stratification. We also present finite element (FE) model based thermal-mechanical stress analysis of a pressurized water reactor (PWR) surge line under grid-load-following loading condition. In addition, we present work related to end-of-life prediction of a PWR surge line based on ASME code and NUREG-6909 deterministic approaches under design-basis and grid-load-following conditions. Our research in this report period also majorly involved with the development of a strategy for probabilistic fatigue life estimation. First, we applied a Weibull probabilistic modeling approach based on end-of-life fatigue data (traditional S~N data under in-air and PWR water conditions) to estimate the probabilistic life for a given strain amplitude. Second, we developed a data analytics based Markov-Chain-Monte-Carlo (MCMC) model for probabilistic modeling of time-series fatigue damage states and the associated probabilistic end-of-life of a component. Unlike the Weibull type approach, the MCMC type may not require a large number of fatigue tests for estimating the end-of-life for given loading and environmental conditions. We demonstrated the use of this framework through symmetric fatigue tests (stress- or strain-ontrolled tests either under in-air or PWR-water conditions) obtained from our earlier experiments. The MCMC model can use base time-series data either obtained from a model or fatigue experiment. Since experimental data are typically more accurate than model-calculated data, we used experiment-based time-series data to demonstrate the MCMC framework. However, when performing a complex experiment is not possible (due to time and costs involved), a model-based approach can be used to generate the time-series data. Similar model-based data are presented in our earlier report (e.g. for cyclic hardening damage states of a PWR surge line under constant amplitude and design-basis loading [1]). However, for the MCMC work in this report, we used experiment-based time-series damage states obtained from fatigue experiments under design-basis and grid-load-following loading conditions. The experimental loading inputs were based on thermal-mechanical FE model results of a typical PWR surge line. Then, we used the experimental time-series damage state data for forecasting the probabilistic time-series damage states and end-of-life of the PWR surge line. Based on this MCMC modeling strategy, and with the assumed loading, environment and thermal-mechanical boundary conditions, we have estimated that a 316SS-pure base metal PWR surge line would survive at least 159 years with zero failure probability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and validation of a cold load for characterization of CMB-S4 detectors

We present the design and validation of a variable temperature cryogenic blackbody source, hereinafter called a cold load, that will be used to characterize detectors to be deployed by CMB-S4, the next-generation ground-based cosmic microwave background (CMB) experiment. Although cold loads have been used for detector characterization by previous CMB experiments, this cold load has three novel design features: (1) the ability to operate from the 1 K stage of a dilution refrigerator (DR), (2) a 3He gas-gap heat switch to reduce cooling time, and (3) the ability to couple small external optical signals to measure detector optical time constants under low optical loading. The efficacy of this design was validated using a 150 GHz detector array previously deployed by the Spider experiment. Here, thermal tests showed that the cold load can be heated to temperatures required for characterizing CMB-S4’s detectors without significantly impacting the temperatures of other cryogenic stages when mounted to the DR’s 1 K stage. Additionally, optical tests demonstrated that external signals can be coupled to a detector array through the cold load without imparting a significant optical load on the detectors, which will enable measurements of the CMB-S4 detectors’ optical time constants.

47 OTHER INSTRUMENTATION↗