Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “delay errors.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

The Effects of the Uncertainty of Departures on Multi-Center Traffic Management Advisor (TMA) Scheduling

The Multi-center Traffic Management Advisor (McTMA) provides a platform for regional or national traffic flow management, by allowing long-range cooperative time-based metering to constrained resources, such as airports or air traffic control center boundaries. Part of the demand for resources is made up of proposed departures, whose actual departure time is difficult to predict. For this reason, McTMA does not schedule the departures in advance, but rather relies on traffic managers to input their requested departure time. Because this happens only a short while before the aircraft's actual departure, McTMA is unable to accurately predict the amount of delay airborne aircraft will need to take in order to accommodate the departures. The proportion of demand which is made up by such proposed departures increases as the horizon over which metering occurs gets larger. This study provides an initial analysis of the severity of this problem in a 400-500 nautical mile metering horizon and discusses potential solutions to accommodate these departures. The challenge is to smoothly incorporate departures with the airborne stream while not excessively delaying the departures.' In particular, three solutions are reviewed: (1) scheduling the departures at their proposed departure time; (2) not scheduling the departures in advance; and (3) scheduling the departures at some time in the future based on an estimated error in their proposed time. The first solution is to have McTMA to automatically schedule the departures at their proposed departure times. Since the proposed departure times are indicated in their flight times in advance, this method is the simplest, but studies have shown that these proposed times are often incorrect2 The second option is the current practice, which avoids these inaccuracies by only scheduling aircraft when a confirmed prediction of departure time is obtained from the tower of the departure airport. Lastly, McTMA can schedule the departures at a predicted departure time based on statistical data of past departure time performance. It has been found that departures usually have a wheels-up time after their indicated proposed departure time, as shown in Figure 1. Hence, the departures were scheduled at a time in the future based on the mean error in proposed departure times for their airport.

Thipphavong, Jane↗

Recovery of Large Angular Scale CMB Polarization for Instruments Employing Variable-Delay Polarization Modulators

Variable-delay Polarization Modulators (VPMs) are currently being implemented in experiments designed to measure the polarization of the cosmic microwave background on large angular scales because of their capability for providing rapid, front-end polarization modulation and control over systematic errors. Despite the advantages provided by the VPM, it is important to identify and mitigate any time-varying effects that leak into the synchronously modulated component of the signal. In this paper, the effect of emission from a 300 K VPM on the system performance is considered and addressed. Though instrument design can greatly reduce the influence of modulated VPM emission, some residual modulated signal is expected. VPM emission is treated in the presence of rotational misalignments and temperature variation. Simulations of time-ordered data are used to evaluate the effect of these residual errors on the power spectrum. The analysis and modeling in this paper guides experimentalists on the critical aspects of observations using VPMs as front-end modulators. By implementing the characterizations and controls as described, front-end VPM modulation can be very powerful for mitigating 1/ f noise in large angular scale polarimetric surveys. None of the systematic errors studied fundamentally limit the detection and characterization of B-modes on large scales for a tensor-to-scalar ratio of r= 0.01. Indeed, r less than 0.01 is achievable with commensurately improved characterizations and controls.

Miller, N. J.↗

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗

Evidence Report: Risk of Inadequate Human-Computer Interaction

Human-computer interaction (HCI) encompasses all the methods by which humans and computer-based systems communicate, share information, and accomplish tasks. When HCI is poorly designed, crews have difficulty entering, navigating, accessing, and understanding information. HCI has rarely been studied in an operational spaceflight context, and detailed performance data that would support evaluation of HCI have not been collected; thus, we draw much of our evidence from post-spaceflight crew comments, and from other safety-critical domains like ground-based power plants, and aviation. Additionally, there is a concern that any potential or real issues to date may have been masked by the fact that crews have near constant access to ground controllers, who monitor for errors, correct mistakes, and provide additional information needed to complete tasks. We do not know what types of HCI issues might arise without this "safety net". Exploration missions will test this concern, as crews may be operating autonomously due to communication delays and blackouts. Crew survival will be heavily dependent on available electronic information for just-in-time training, procedure execution, and vehicle or system maintenance; hence, the criticality of the Risk of Inadequate HCI. Future work must focus on identifying the most important contributing risk factors, evaluating their contribution to the overall risk, and developing appropriate mitigations. The Risk of Inadequate HCI includes eight core contributing factors based on the Human Factors Analysis and Classification System (HFACS): (1) Requirements, policies, and design processes, (2) Information resources and support, (3) Allocation of attention, (4) Cognitive overload, (5) Environmentally induced perceptual changes, (6) Misperception and misinterpretation of displayed information, (7) Spatial disorientation, and (8) Displays and controls.

Kritina Holden↗

The Mars Science Laboratory (MSL) MMRTG In-Flight: A Power Update

The MSL Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) was fueled on October 28, 2008 by the Department Of Energy (DOE) in preparation for a late 2009 launch. Shortly after, the MSL launch was delayed approximately 2 years until 2011. The fueled MMRTG was placed in storage to await the new date for liftoff. Occasional measurements of the MMRTG's power output were taken and compared with power predictions that pre-dated fueling. An error in the predictive models was quickly recognized and remedied. The predictions, while improved, carried significant uncertainty. This uncertainty did not deter the launch of MSL, but did alter the planned mission on the surface of Mars. Once launched, the MSL spacecraft provided a hi-fidelity telemetry stream measuring the generator's electrical and thermal performance. These data were used to update the predictive models and a new prediction of the performance of the MMRTG on the surface of Mars was run just before Entry, Descent, and Landing (EDL) at Mars. The MSL MMRTG is working extremely well, providing power above predictions and operating within its flight allowable temperature limits. The generator was producing approximately 114 W at the beginning of the surface mission. This paper will elaborate on power modeling for the MSL MMRTG along with a review of some of the data recorded from the MSL cruise to Mars, EDL, and the early days of the surface mission.

thermoelectric generator↗

The Mars Science Laboratory (MSL) MMRTG In-Flight: A Power Update

The MSL Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) was fueled on October 28, 2008 by the Department Of Energy (DOE) in preparation for a late 2009 launch. Shortly after, the MSL launch was delayed approximately 2 years until 2011. The fueled MMRTG was placed in storage to await the new date for liftoff. Occasional measurements of the MMRTG's power output were taken and compared with power predictions that pre-dated fueling. An error in the predictive models was quickly recognized and remedied. The resultant predictions, while improved, carried significant uncertainty. This uncertainty did not deter the launch of MSL, but did alter the planned mission on the surface of Mars. Once launched, the MSL spacecraft provided a hi-fidelity telemetry stream measuring the generator's electrical and thermal performance. These data were used to update the predictive models and a new prediction of the performance of the MMRTG on the surface of Mars was run just before Entry, Descent, and Landing (EDL) at Mars. The MSL MMRTG is working extremely well, providing power above predictions and operating within its flight allowable temperature limits. The generator was producing approximately 114 W at the beginning of the surface mission. This paper will elaborate on power modeling for the MSL MMRTG along with a review of some of the data recorded from the MSL cruise to Mars, EDL, and the early days of the surface mission.

thermoelectric↗

Telerobotics - Display, control, and communication problems

An experimental telerobotics simulation is described suitable for studying human operator (HO) performance. Simple manipulator pick-and-place and tracking tasks allowed quantitative comparison of a number of calligraphic display viewing conditions. An enhanced perspective display was effective with a reference line from target to base, with or without a complex three-dimensional grid framing the view. This was true especially if geometrical display parameters such as azimuth and elevation were arranged to be near optimal. Quantitative comparisons were made possible, utilizing control performance measures such as root mean square error. There was a distinct preference for controlling the manipulator in end-effector Cartesian space for the primitive pick-and-place task, rather than controlling joint angles and then, via direct kinematis, the end-effector position. An introduced communication delay was found to produce decrease in performance. In considerable part, this difficulty could be compensated for by preview control information. The fact that neurological control of normal human movement contains a sampled data period of 0.2 s may relate to this robustness of HO control to delay.

Stark, Lawrence↗

Patterning the dorsal longitudinal flight muscles (DLM) of Drosophila: insights from the ablation of larval scaffolds

The six Dorsal Longitudinal flight Muscles (DLMs) of Drosophila develop from three larval muscles that persist into metamorphosis and serve as scaffolds for the formation of the adult fibers. We have examined the effect of muscle scaffold ablation on the development of DLMs during metamorphosis. Using markers that are specific to muscle and myoblasts we show that in response to the ablation, myoblasts which would normally fuse with the larval muscle, fuse with each other instead, to generate the adult fibers in the appropriate regions of the thorax. The development of these de novo DLMs is delayed and is reflected in the delayed expression of erect wing, a transcription factor thought to control differentiation events associated with myoblast fusion. The newly arising muscles express the appropriate adult-specific Actin isoform (88F), indicating that they have the correct muscle identity. However, there are frequent errors in the number of muscle fibers generated. Ablation of the larval scaffolds for the DLMs has revealed an underlying potential of the DLM myoblasts to initiate de novo myogenesis in a manner that resembles the mode of formation of the Dorso-Ventral Muscles, DVMs, which are the other group of indirect flight muscles. Therefore, it appears that the use of larval scaffolds is a superimposition on a commonly used mechanism of myogenesis in Drosophila. Our results show that the role of the persistent larval muscles in muscle patterning involves the partitioning of DLM myoblasts, and in doing so, they regulate formation of the correct number of DLM fibers.

Non-NASA Center↗

Delivery and application of precise timing for a traveling wave powerline fault locator system

The Bonneville Power Administration (BPA) has successfully operated an in-house developed powerline fault locator system since 1986. The BPA fault locator system consists of remotes installed at cardinal power transmission line system nodes and a central master which polls the remotes for traveling wave time-of-arrival data. A power line fault produces a fast rise-time traveling wave which emanates from the fault point and propagates throughout the power grid. The remotes time-tag the traveling wave leading edge as it passes through the power system cardinal substation nodes. A synchronizing pulse transmitted via the BPA analog microwave system on a wideband channel sychronizes the time-tagging counters in the remote units to a different accuracy of better than one microsecond. The remote units correct the raw time tags for synchronizing pulse propagation delay and return these corrected values to the fault locator master. The master then calculates the power system disturbance source using the collected time tags. The system design objective is a fault location accuracy of 300 meters. BPA's fault locator system operation, error producing phenomena, and method of distributing precise timing are described.

Street, Michael A.↗

Using input command pre-shaping to suppress multiple mode vibration

Spacecraft, space-borne robotic systems, and manufacturing equipment often utilize lightweight materials and configurations that give rise to vibration problems. Prior research has led to the development of input command pre-shapers that can significantly reduce residual vibration. These shapers exhibit marked insensitivity to errors in natural frequency estimates and can be combined to minimize vibration at more than one frequency. This paper presents a method for the development of multiple mode input shapers which are simpler to implement than previous designs and produce smaller system response delays. The new technique involves the solution of a group of simultaneous non-linear impulse constraint equations. The resulting shapers were tested on a model of MACE, an MIT/NASA experimental flexible structure.

Hyde, James M.↗

Verifiable Adaptive Control with Analytical Stability Margins by Optimal Control Modification

This paper presents a verifiable model-reference adaptive control method based on an optimal control formulation for linear uncertain systems. A predictor model is formulated to enable a parameter estimation of the system parametric uncertainty. The adaptation is based on both the tracking error and predictor error. Using a singular perturbation argument, it can be shown that the closed-loop system tends to a linear time invariant model asymptotically under an assumption of fast adaptation. A stability margin analysis is given to estimate a lower bound of the time delay margin using a matrix measure method. Using this analytical method, the free design parameter n of the optimal control modification adaptive law can be determined to meet a specification of stability margin for verification purposes.

Nguyen, Nhan T.↗

Kalman filter estimation of human pilot-model parameters

The parameters of a human pilot-model transfer function are estimated by applying the extended Kalman filter to the corresponding retarded differential-difference equations in the time domain. Use of computer-generated data indicates that most of the parameters, including the implicit time delay, may be reasonably estimated in this way. When applied to two sets of experimental data obtained from a closed-loop tracking task performed by a human, the Kalman filter generated diverging residuals for one of the measurement types, apparently because of model assumption errors. Application of a modified adaptive technique was found to overcome the divergence and to produce reasonable estimates of most of the parameters.

Schiess, J. R.↗

The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements

Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

Wang, H. T.↗

Effects of Control Stick Parameters on Human Controller Response

A fixed base laboratory tracking study was conducted to determine the effects of stick displacement and stick force characteristics on human tracking performance. Three different levels of control stick force/displacement characteristics and stick electrical gain were varied to observe their influence on RMS (Root Mean Square) tracking error and RMS control activity (stick output). The results indicated that both RMS tracking error and RMS control activity were influenced by the three different levels of control stick force/displacement characteristics and stick electrical gain. The human neuromotor time constant was affected by the electrical control gain of the stick while the spring stiffness of the stick influenced the time delay characteristics of the human response behavior.

Repperger, D. W.↗

Improved ranging systems

Spacecraft range measurements have provided the most accurate tests, to date, of some relativistic gravitational parameters, even though the measurements were made with ranging systems having error budgets of about 10 meters. Technology is now available to allow an improvement of two orders of magnitude in the accuracy of spacecraft ranging. The largest gains in accuracy result from the replacement of unstable analog components with high speed digital circuits having precisely known delays and phase shifts.

Young, Larry E.↗

Tele-Autonomous control involving contact

Object localization and its application in tele-autonomous systems are studied. Two object localization algorithms are presented together with the methods of extracting several important types of object features. The first algorithm is based on line-segment to line-segment matching. Line range sensors are used to extract line-segment features from an object. The extracted features are matched to corresponding model features to compute the location of the object. The inputs of the second algorithm are not limited only to the line features. Featured points (point to point matching) and featured unit direction vectors (vector to vector matching) can also be used as the inputs of the algorithm, and there is no upper limit on the number of the features inputed. The algorithm will allow the use of redundant features to find a better solution. The algorithm uses dual number quaternions to represent the position and orientation of an object and uses the least squares optimization method to find an optimal solution for the object's location. The advantage of using this representation is that the method solves for the location estimation by minimizing a single cost function associated with the sum of the orientation and position errors and thus has a better performance on the estimation, both in accuracy and speed, than that of other similar algorithms. The difficulties when the operator is controlling a remote robot to perform manipulation tasks are also discussed. The main problems facing the operator are time delays on the signal transmission and the uncertainties of the remote environment. How object localization techniques can be used together with other techniques such as predictor display and time desynchronization to help to overcome these difficulties are then discussed.

Shao, Lejun↗

On-line diagnosis of unrestricted faults

Attention is given to the formal development of the notion of a discrete-time system and the associated concepts of fault, result of a fault, and error. The considered concept of on-line diagnosis is formalized and a diagnosis using inverse machines is discussed. The case of an inverse which is lossless is investigated. It is found that in such a case the class of unrestricted faults can be diagnosed with a delay equal to the delay of losslessness of the inverse system.

Meyer, J. F.↗

Short baseline phase delay interferometry

The high precision of the phase delay data type allows angular navigation accuracy on relatively short baselines to compete with the angular accuracy achieved with long baseline group delay measurements. Differential phase delay observations of close quasar pairs on both a 5.9-km baseline (DSS 12-DSS 13) and a 253-km baseline (DSS 13-Owens Valley Radio Observatory) have been performed to study the potential navigational precision and accuracy of the short baseline interferometry. As a first step toward demonstration of a connected element system at Goldstone, the DSS 12-DSS 13 baseline was operated coherently, distributing a common frequency reference via a recently installed fiber optic cable. The observed phase delay residuals of about 10 psec or less on both baselines appear to be dominated by short term troposphere fluctuations, and correspond to navigational accuracies of well below 50 nrad for the 253-km baseline. Additional experiments will be required to probe the full range of systematic errors.

Edwards, C. D.↗