COLD-SAT: A technology satellite for cryogenic experimentation

NASA-Lewis (LeRC) is involved in the development and validation of analytical models which describe the fluid dynamic and thermodynamic processes associated with the storage, acquisition and transfer of subcritical cryogenic fluids in low gravity. Four concurrent studies, including one in-house at LeRC, are underway to determine the feasibility of performing model validation experiments aboard a free-flying spacecraft (S/C) called Cryogenic On-Orbit Liquid Depot-Storage, Acquisition and Transfer (COLD-SAT), using liquid hydrogen as the cryogen. The technology requirements for the experiments are described along with the initial LeRC concepts for the S/C and an experiment subsystem comprising of cryogenic tankage (a supply dewar and three receiver tanks), gas pressurization bottles (both helium and autogenous hydrogen), their associated plumbing, and instrumentation for data collection. Experiments were categorized into enabling/high priority Class 1 technologies and component/system Class 2 demonstrations. As initially envisioned by LeRC, COLD-SAT would have had a 1997 launch aboard a Delta-2 for a 6 month active lifetime in a 925 km orbit with a pseudo-inertial attitude.

Arif, H.↗

Cryogenic wind tunnels for high Reynolds number testing

This paper begins with a brief review of cryogenic wind tunnels and their use for high Reynolds number testing. Emphasis is on operational experience and recent aerodynamic tesing in the NASA Langley 0.3-m Transonic Cryogenic Tunnel (TCT). Specific area covered in this paper include development of test techniques and aerodynamic testing in cryogenic tunnels. Details of research experience in developing model construction techniques, including airfoils as thin as 5 percent, are given. The use of advanced testing techniques to increase the value of cryogenic tunnels to the research community is recommended. These include adaptive wall test sections using solid but flexible top and bottom walls and magnetic suspension and balance systems.

Kilgore, Robert A.↗

Experience with strain-gage balances for cryogenic wind tunnels

The U.S. National Transonic Facility (NTF) is a cryogenic wind tunnel build to meet the United States' needs for high Reynolds number testing. The facility was declared operational in August 1984, and since that time numerous models were tested in the NTF using unheated strain-gage balances to measure aerodynamic forces. The difficulty in accurately measuring forces and moments of models in conventional wind tunnels becomes more challenging at cryogenic conditions. The Force and Strain Instrumentation Section of the Instrument Research Division at NASA Langley Research Center designed and fabricated the balances to measure forces at cryogenic temperatures without thermally controlling the balance temperature. Presented are balance results from a recent cryogenic test program in the NTF. The data indicated the accuracy with which aerodynamic forces are determined using current instrumentation and test methods as well as identified areas for future research.

Williams, M. Susan↗

Cryogenic optical tests of a lightweight HIP beryllium mirror

Five interferometric tests were conducted at cryogenic temperatures on a lightweight, 50 cm diameter, hot isostatic pressed (HIP) beryllium mirror in the Ames Research Center (ARC) Cryogenic Optics Test Facility. The purpose of the tests was to determine the stability of the mirror's figure when cooled to cryogenic temperatures. Test temperatures ranged from room ambient to 8 K. One cycle to 8 K and five cycles to 80 K were performed. Optical and thermal test methods are described. Data is presented to show the amount of cryogenic distortion and hysteresis present in the mirror when measured with an earlier, Shack interferometer, and with a newly-acquired, phase-measuring interferometer.

Melugin, Ramsey K.↗

Cryogenic absolute radiometers as laboratory irradiance standards, remote sensing detectors, and pyroheliometers

The dramatic improvement in heat diffusivity of pure Cu at liquid-He temperatures makes possible very important advances in the absolute accuracy, reproducibility, sensitivity, and time constant of cryogenic electrical substitution radiometers (ESRs), relative to conventional ESRs. The design and characterization of a table-top cryogenic ESR now available for detector calibration work to the 0.01-percent level of absolute accuracy under laser illumination is discussed. A sensitive cryogenic ESR recently delivered to the NIST for radiometric calibrations of black bodies is also described, along with the design and testing of a very fast cryogenic ESR developed for NASA remote-sensing studies of the earth's radiation budget.

Foukal, Peter V.↗

Space Cryogenic Workshop, 8th, California Institute of Technology, Pasadena, July 31, Aug. 1, 1989, Proceedings

Recent advances in cryogenic technology for space applications are examined in reviews and reports. Topics addressed include very-low-force cooling contacts for the ISO cryostat cover, convective heat flow in space cryogenics plugs, liquid-acquisition devices for superfluid He transfer, and pressure drop in the SHOOT superfluid-He acquisition system. Consideration is given to a liquid-He vibration cryostat for space qualification tests, closed-cycle coolers for temperatures below 30 K, stress analysis down to liquid-He temperature, a cryogenic valve actuator, and a spaceborne He-3 refrigerator. Also discussed are an adiabatic-demagnetization refrigerator for SIRTF, rejection of waste heat from O liquefaction operations at a lunar O production plant, SHOOT flowmeter and pressure transducers, and space qualification of the ISO cryogenic rupture disks.

Source record↗

Cryogenic wind tunnels

Cryogenic wind tunnels and their use for high Reynolds number testing are reviewed. Emphasis is given to operational and aerodynamic testing experience in the NASA Langley 0.3-m Transonic Cryogenic Tunnel. Areas covered include development of test techniques and aerodynamic testing in cryogenic tunnels. The use of advanced testing techniques to increase the value of cryogenic tunnels is recommended. These include adaptive wall test sections, using solid but flexible top and bottom walls, and magnetic suspension and balance systems.

Kilgore, Robert A.↗

Cryogenic wind tunnels. I

The basic principles of cryogenic wind-tunnel operation are presented, and a typical cryogenic wind tunnel is described. Low-speed cryogenic wind tunnels are considered, along with some experiments conducted in these tunnels. Focus is placed on real-gas effects including condensation and thermal and caloric imperfections. The operating limits set by the saturation boundaries of nitrogen and air are analyzed, and the consequences of thermal and caloric imperfections on both isentropic and normal-shock flow in nitrogen are considered. The extension of analytical real-gas studies, including both laminar and turbulent boundary layers is covered. It is concluded that the deviation of the nitrogen boundary-layer parameters from their ideal-gas values are small, and that large real-gas effects will not be a factor in cryogenic tunnel simulation of the complex flows met in flight.

Kilgore, Robert A.↗

Cryogenic shutter

A magnetically operated shutter mechanism is provided that will function in cryogenic or cryogenic zero gravity environments to selectively block radiation such as light from passing through a window to a target object such as a mirror or detector located inside a cryogenic container such as a dewar. The mechanism includes a shutter paddle blade that is moved by an electromagnetically actuated torquing device between an open position where the target object is exposed to ambient radiation or light and a closed position where the shutter paddle blade shields the ambient radiation or light from the target object. The purpose of the shuttering device is to prevent the mirror or other target object from being directly exposed to radiation passing through the window located on the side wall of the dewar, thereby decreasing or eliminating any temperature gradient that would occur within the target object due to exposure to the radiation. A special nylon bearing system is utilized to prevent the device from binding during operation and the paddle blade is also thermally connected to a reservoir containing cryogen to further reduce the internal temperature.

Barney, Richard D.↗

Qualitative investigation of cryogenic fluid injection into a supersonic flow field

The behavior of liquid nitrogen injected into a supersonic nitrogen flow field was investigated using an experimental apparatus in which a Mach 2.7 2D gas nitrogen tunnel is coupled with a high-pressure cryogenic source. Observations were monitored and recorded via a video camera and a motion picture camera. It was found that the penetration of a supersonic flow field by injection of liquid nitrogen is strongly dependent on the flow Mach number, the cryogen injection pressure (Pi/Pc), the injector configuration, and the cryogen temperature. For a 2D gaseous N2, Mach 2.7 tunnel, with cryogen injection Pi/Pc approaching 2, the injected fluid penetration for the 1/8-in. injection port approached one half of the tunnel width at 90-deg injection, and one fourth of the tunnel width at 20-deg injection.

Hendricks, R. C.↗

COLD-SAT - A technology satellite for cryogenic experimentation

NASA-Lewis (LeRC) is involved in the development and validation of analytical models which describe the fluid dynamic and thermodynamic processes associated with the storage, acquisition and transfer of subcritical cryogenic fluids in low gravity. Four concurrent studies, including one in-house at LeRC, are underway to determine the feasibility of performing model validation experiments aboard a free-flying spacecraft (S/C) called Cryogenic On-Orbit Liquid Depot-Storage, Acquisition and Transfer (COLD-SAT), using liquid hydrogen as the cryogen. The technology requirements for the experiments are described along with the initial LeRC concepts for the S/C and an experiment subsystem comprising of cryogenic tankage (a supply dewar and three receiver tanks), gas pressurization bottles (both helium and autogenous hydrogen), their associated plumbing, and instrumentation for data collection. Experiments were categorized into enabling/high priority Class 1 technologies and component/system Class 2 demonstrations. As initially envisioned by LeRC, COLD-SAT would have had a 1997 launch aboard a Delta-2 for a 6 month active lifetime in a 925 km orbit with a pseudo-inertial attitude.

Arif, H.↗

Cryogenic on-orbit liquid depot storage acquisition and transfer (COLD-SAT) experiment subsystem instrumentation and wire harness design report

Subcritical cryogens such as liquid hydrogen (LH2) and liquid oxygen (LO2) are required for space based transportation propellant, reactant, and life support systems. Future long-duration space missions will require on-orbit systems capable of long-term cryogen storage and efficient fluid transfer capabilities. COLD-SAT, which stands for cryogenic orbiting liquid depot-storage acquisition and transfer, is a free-flying liquid hydrogen management flight experiment. Experiments to determine optimum methods of fluid storage and transfer will be performed on the COLD-SAT mission. The success of the mission is directly related to the type and accuracy of measurements made. The instrumentation and measurement techniques used are therefore critical to the success of the mission. This paper presents the results of the COLD-SAT experiment subsystem instrumentation and wire harness design effort. Candidate transducers capable of fulfilling the COLD-SAT experiment measurement requirements are identified. Signal conditioning techniques, data acquisition requirements, and measurement uncertainty analysis are presented. Electrical harnessing materials and wiring techniques for the instrumentation designed to minimize heat conduction to the cryogenic tanks and provide optimum measurement accuracy are listed.

Edwards, Lawrence G.↗

Feasibility study for a Cryogenic On-Orbit Liquid Depot-Storage, Acquisition and Transfer (COLD-SAT) satellite

This feasibility study presents the conceptual design of a spacecraft for performing a series of cryogenic fluid management flight experiments. This spacecraft, the Cryogenic On-Orbit Liquid Depot-Storage, Acquisition, and Transfer (COLD-SAT) satellite, will use liquid hydrogen as the test fluid, be launched on a Delta expendable launch vehicle, and conduct a series of experiments over a two to three month period. These experiments will investigate the physics of subcritical cryogens in the low gravity space environment to characterize their behavior and to correlate the data with analytical and numerical models of in-space cryogenic fluid management systems. Primary technologies addressed by COLD-SAT are: (1) pressure control; (2) chilldown; (3) no-vent fill; (4) liquid acquisition device fill; (5) pressurization; (6) low-g fill and drain; (7) liquid acquisition device expulsion; (8) line chilldown; (9) thermodynamic state control; and (10) fluid dumping.

Rybak, S. C.↗

Cryogenic Two-Phase Flight Experiment: Results overview

This paper focuses on the flight results of the Cryogenic Two-Phase Flight Experiment (CRYOTP), which was a Hitchhiker based experiment that flew on the space shuttle Columbia in March of 1994 (STS-62). CRYOTP tested two new technologies for advanced cryogenic thermal control; the Space Heat Pipe (SHP), which was a constant conductance cryogenic heat pipe, and the Brilliant Eyes Thermal Storage Unit (BETSU), which was a cryogenic phase-change thermal storage device. These two devices were tested independently during the mission. Analysis of the flight data indicated that the SHP was unable to start in either of two attempts, for reasons related to the fluid charge, parasitic heat leaks, and cryocooler capacity. The BETSU test article was successfully operated with more than 250 hours of on-orbit testing including several cooldown cycles and 56 freeze/thaw cycles. Some degradation was observed with the five tactical cryocoolers used as thermal sinks, and one of the cryocoolers failed completely after 331 hours of operation. Post-flight analysis indicated that this problem was most likely due to failure of an electrical controller internal to the unit.

Swanson, T.↗

Cryogenic Insulation Systems

The results of a comparative study of cryogenic insulation systems performed are presented. The key aspects of thermal insulation relative to cryogenic system design, testing, manufacturing, and maintenance are discussed. An overview of insulation development from an energy conservation perspective is given. Conventional insulation materials for cryogenic applications provide three levels of thermal conductivity. Actual thermal performance of standard multilayer insulation (MLI) is several times less than laboratory performance and often 10 times worse than ideal performance. The cost-effectiveness of the insulation system depends on thermal performance; flexibility and durability; ease of use in handling, installation, and maintenance; and overall cost including operations, maintenance, and life cycle. Results of comprehensive testing of both conventional and novel materials such as aerogel composites using cryostat boil-off methods are given. The development of efficient, robust cryogenic insulation systems that operate at a soft vacuum level is the primary focus of this paper.

Augustynowicz, S. D.↗

Flight Testing of a Cryogenic Capillary Pumped Loop

Future space-based cryogenic systems will require enhanced integration flexibility, lower weight reduced parasitic penalties, better vibration isolation, and a variety of other improvements to meet performance goals. Additionally, there is an increasing need to locate cooling sources remotely from cooled components. In the past flexible conductive links were used and worked well in most cases. However, as the transport lengths increase, conductive couplings become heavier and less effective, and must be replaced by higher performance systems. One available option, which can meet many of these future requirements, is the cryogenic capillary pumped loop (CCPL). The development of the CCPL technology started in 1992, following the success of the room temperature CPLS. The extrapolation of CCPL technology to cryogenic temperatures offers many performance benefits, which are not currently within the reach of traditional heat pipes or conductive links. Specific advantages of the CCPL technology pertaining to cryocooler integration include: (1) greater capillary pumping pressure for improved ground testability; (2) improved mechanical isolation; (3) faster diode shutdown and lower reverse heat leaks; (4) tighter control of detector temperature; (5) variable or fixed conductance operation; and (6) ease of integration due to their flexibility. The applications of CCPL technology are numerous. Military and commercial applications include surveillance satellites, earth observing satellites, deep space observation systems, medical devices, and many other cryogenic systems. Over the past few years, several breadboard and prototype CCPLs have been built and ground tested. A prototype CCPL has demonstrated successful operation between 80K and 110K with heat loads between O.5W and 12W using nitrogen as the working fluid, and 35K and 40K with head loads of 0.25W to 3.5W using neon. In order to verify CCPL performance in a microgravity environment, a flight unit, CCPL-5, was tested onboard the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 under zero-G environment The CCPL could start from a supercritical condition in all tests, and the loop operating temperature could be tightly controlled regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with a heat load of 0.5W as well as with parasitic heat loads alone. There were no noticeable differences between zero-G and one-G operation.

Ku, Jentung↗

Large Scale Testing of a Foam/Multilayer Insulation Thermal Control System (TCS) for Cryogenic Upper Stages

The development of high energy cryogenic upper stages is essential for the efficient delivery of large payloads to various destinations envisioned in future programs. A key element in such upper stages is cryogenic fluid management (CFM) advanced development/technology. Due to the cost of and limited opportunities for orbital experiments, ground testing must be employed to the fullest extent possible. Therefore, a system level test bed termed the Multipurpose Hydrogen Test Bed (MHTB), which is representative in size and shape (3 meter diameter by 3 meter long with a volume of 18 cubic meters) of a fully integrated space transportation vehicle liquid hydrogen propellant tank has been established. To date, upper stage studies have often baselined the foam/multilayer insulation (FMLI) combination concept; however, hardware experience with the concept is minimal and was therefore selected for the MHTB. The foam element (isofoam SS-1 171 with an average thickness of 3.5 centimeters) is designed to protect against ground hold/ascent flight environments, and allows for the use of a dry nitrogen purge as opposed to the more complex/heavy helium purge subsystem normally required with MLI in cryogenic applications. The MLI (45 layers of Double Aluminized Mylar with Dacron spacers) provides protection in the vacuum environment of space and is designed for an on-orbit storage period of 45 days. Several unique features were incorporated in the MLI concept and included: variable density MLI (reduces weight and radiation losses by changing the layer density), larger but fewer DAM perforations for venting during ascent to orbit (reduces radiation losses), and roll wrap installation of the MLI with a commercially established process to lower assembly man-hours and reduce seam heat leak. Thermal performance testing of the MHTB TCS was conducted during three test series conducted between September 1995 and May 1996. Results for the ground hold portion of the tests were as expected producing an average heat leak of 63 WattS/M2 at an average foam surface temperature of 170 K. The results of the simulated orbit hold test interval produced heat leaks ranging from 0.085 to 0.22 Watts/squareM at warm boundary temperatures of 164K and 305K, respectively. When compared to the performance for a traditional MLI system, a 60% reduction in orbital heat leak or boiloff was measured. Overall, the MHTB TCS demonstrated satisfactory performance for all mission phases required of a cryogenic upper stage.

Hastings, Leon↗

Analysis and Design of the NASA Langley Cryogenic Pressure Box

A cryogenic pressure box was designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 72 in. x 60 in. curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20K) with 54 psig maximum pressure on the concave side, and elevated temperatures and atmospheric pressure on the convex surface. The internal surface of the panel is cooled by high pressure helium as that is cooled to -423 F by liquid helium heat exchangers. An array of twelve independently controlled fans circulate the high pressure gaseous helium to provide uniform cooling on the panel surface. The load introduction structure, consisting of four stainless steel load plates and numerous fingers attaching the load plates to the test panel, is designed to introduce loads into the test panel that represent stresses that will he observed in the actual tank structure. The load plates are trace cooled with liquid nitrogen to reduce thermal gradients that may result in bending the load plates, and thus additional stresses in the test panel. The design of the cryogenic systems, load introduction structure, and control system are discussed in this report.