Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Electronics Demonstrated for Low- Temperature Operation

The operation of electronic systems at cryogenic temperatures is anticipated for many NASA spacecraft, such as planetary explorers and deep space probes. For example, an unheated interplanetary probe launched to explore the rings of Saturn would experience an average temperature near Saturn of about 183 C. Electronics capable of low-temperature operation in the harsh deep space environment also would help improve circuit performance, increase system efficiency, and reduce payload development and launch costs. An ongoing research and development program on low-temperature electronics at the NASA Glenn Research Center at Lewis Field is focusing on the design of efficient power systems that can survive and exploit the advantages of low-temperature environments. The targeted systems, which are mission driven, include converters, inverters, controls, digital circuits, and special-purpose circuits. Initial development efforts successfully demonstrated the low-temperature operation and cold-restart of several direct-current/direct-current (dc/dc) converters based on different types of circuit design, some with superconducting inductors. The table lists some of these dc/dc converters with their properties, and the photograph shows a high-voltage, high-power dc/dc converter designed for an ion propulsion system for low-temperature operation. The development efforts of advanced electronic systems and the supporting technologies for low-temperature operation are being carried out in-house and through collaboration with other Government agencies, industry, and academia. The Low Temperature Electronics Program supports missions and development programs at NASA s Jet Propulsion Laboratory and Goddard Space Flight Center. The developed technologies will be transferred to commercial end users for applications such as satellite infrared sensors and medical diagnostic equipment.

Patterson, Richard L.↗

Cryogenic Selective Surfaces

There are many challenges involved in deep-space exploration, but several of these can be mitigated, or even solved, by the development of a coating that can reject most of the Sun's energy and yet still provide some far-infrared heat emission. Such a coating would allow non-heat-generating objects in space to reach cryogenic temperatures without using an active cooling system. This would be a benefit to deep-space sensors that require low temperatures, such as the James Webb Telescope focal plane array. It would also allow the use of superconductors in deep space, which could lead to magnetic energy storage rings, lossless power delivery, or perhaps a large-volume magnetic shield against galactic cosmic radiation. But perhaps the most significant enablement achieved from such a coating would be the long-term storage in deep space of cryogenic liquids, such as liquid oxygen (LOX).In this report, we review the state of the art in low-temperature coatings and calculate the lowest temperatures each of these can achieve, demonstrating that cryogenic temperatures cannot be reached in deep space in this fashion. We then propose a new coating that does allow coated objects in deep space to achieve the very low temperatures required to store liquid oxygen or nitrogen. These new coatings consist of a moderately thick scattering layer (typically 5 mm) composed of a material transparent to most of the solar spectrum. This layer acts as a scatterer to the Sun's light, performing the same process as titanium dioxide in white paint in the visible. Under that layer, we place a metallic reflector, e.g. silver, to reflect long-wave radiation that is not well scattered. The result is a coating we call "Solar White," in that it scatters most of the solar spectrum just as white paint does for the visible. Our modeling of these coatings has shown that temperatures as low as 50 K can be reached for a coated object fully exposed to sunlight at 1 AU from the Sun and far from the Earth.In the second half of the report we explore a mission application of this coating in order to show that it allows LOX to be carried on a mission to Mars. Heat can reach a LOX tank in five ways: direct radiation from the Sun, scattered or reflected radiation from the Sun off of spacecraft components, radiation from nearby planets or the Moon, radiation from the infrared emission of other parts of the spacecraft, and conduction along support struts and flow lines. We discuss these and sum their total contribution when using a Solar White coating to demonstrate an architecture that allows the transportation of LOX to Mars. After this, other applications of Solar White are listed.

Cryogenic Materials↗

Cryogenic insulation system Patent

Prefabricated multilayered self-evacuating insulation panels using gas with low vapor pressure at cryogenic temperatures for application to storage of cryogens

Perkins, P. J., Jr.↗

The James Webb Space Telescope

The James Webb Space Telescope (JWST) is a large, infrared-optimized space telescope. JWST's primary science goal is to detect and characterize the first galaxies. It will also study the assembly of galaxies, star formation, and the formation of evolution of planetary systems. The observatory has a large primary mirror 6.5 meter in diameter, designed to deliver high angular resolution in the infrared, combined with a large collecting area. The telescope optics are designed and fabricated to operate at the cryogenic temperatures (,...,40 k) required for an IR optimized telescope. The primary mirror is also a segmented mirror architecture. The observatory is designed to achieve cryogenic operating temperature via passive cooling, facilitated by a five-layer sunshield which keeps the telescope in the sun's shadow. Since the observatory dimensions exceed the Ariane 5 fairing size, the observatory has to be stowed for launch and deployed following launch. The observatory will be launched into an L2 orbit that provides continuous science operations and a benign thermal environment for optical stability.

Clampin, Mark↗

The metallurgical structure and mechanical properties at low temperature of Nitronic 40 with particular reference to its use in the construction of models for cryogenic wind tunnels

Nitronic 40 was chosen for the construction of Pathfinder I, an R & D model for use in the National Transonic Facility, because of its good mechanical properties at cryogenic temperatures. Nitronic 40 contains delta ferrite and is in a sensitized condition. Heat treatments carried out to remove residual stresses also caused further sensitization. Experiments showed that heat treatment followed by cryoquenching removed the sensitization without creating residual stresses. Heat treatment at temperatures of 2200 F was used to remove the delta ferrite but with little success and at the cost of massive grain growth. The implications of using degraded Nitronic 40 for cryogenic wind tunnel models are discussed, together with possible acceptance criteria.

Wigley, D. A.↗

Cryogenic leak testing of tube fittings/valves

A high pressure and variable temperature cryogenic leak testing system was conceived and designed in order to conduct leakage testing of pipe fittings/valves in liquid hydrogen supply lines of the Space Shuttle. The system can create a continuous testing environment of variable temperature, 5.5 to about 300 K, and variable pressure, 0.01 to about 70 x 10 exp 5 Pa, with a large sample space, 90 mm diameter x 228 mm length, and at low operating cost. In terms of cryogenic leak testing the system has a special capability for extensive applications. The system comprised a variable temperature cryostat, a high pressure sample chamber, a vacuum pumping station, gas flow control system, pressure and temperature control systems, and leak detecting and measuring systems. A general discussion of cryogenic leak testing methods is also presented.

Jia, L. X.↗

A Piezoelectric Cryogenic Heat Switch

We have measured the thermal conductance of a mechanical heat switch actuated by a piezoelectric positioner, the PZHS (PieZo electric Heat Switch), at cryogenic temperatures. The thermal conductance of the PZHS was measured between 4 K and 10 K, and on/off conductance ratios greater than 100 were achieved when the positioner applied its maximum force of 8 N. We discuss the advantages of using this system in cryogenic applications, and estimate the ultimate performance of an optimized PZHS.

Low temperature physics↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

Cryogenic Thermal Conductivity Measurements on Candidate Materials for Space Missions

Spacecraft and instruments on space missions are built using a wide variety of carefully-chosen materials. It is common for NASA engineers to propose new candidate materials which have not been totally characterized at cryogenic temperatures. In many cases a material's cryogenic thermal conductivity must be known before selecting it for a specific space-flight application. We developed a test facility in 2004 at NASA's Goddard Space Flight Center to measure the longitudinal thermal conductivity of materials at temperatures between 4 and 300 Kelvin, and we have characterized many candidate materials since then. The measurement technique is not extremely complex, but proper care to details of the setup, data acquisition and data reduction is necessary for high precision and accuracy. We describe the thermal conductivity measurement process and present results for ten engineered materials, including alloys, polymers, composites, and a ceramic.

James Tuttle↗

Solid state crystal physics at very low temperatures

The properties of nearly perfect crystals was studied at cryogenic temperatures. A large Helium 3 and Helium 4 dilution refrigerator has been assembled, and is described. A cryostat suitable for cooling a 35 liter volume to .020 Kelvin was designed and constructed, together with instrumentation to observe the properties of nearly perfect crystals.

Davis, W.↗

Surface Tension Confines Cryogenic Liquid

New type of Dewar provides passive, constant-temperature cryogenic cooling for scientific instruments under normal-to low-gravity conditions. Known as Surface-Tension-Contained Liquid Cryogen Cooler (STCLCC), keeps liquid cryogen in known location inside the Dewar by trapping liquid inside spongelike material. Unique sponge material fills most of volume of inner tank. Sponge is all-silica, open-cell material similar to that used for Space Shuttle thermal-protection tiles.

Castles, Stephen H.↗

Electron Irradiation Effects on Nanocrystal Quantum Dots Used in Bio-Sensing Applications

Effects of electron irradiation on some of the optical properties in organic CdSe nanocrystals coated in trioctylphosphine oxide (TOPO) and biologically compatible CdSe nanocrystals coated in mercaptoacetic acid, as CdSe as CdSe nanocrystals conjugated with the protein are investigated using the technique of cathodoluminescence. Effects of varying the beam energy and temperatures were examined and faster degradation at cryogenic temperatures and higher beam energies was found under some conditions.

nanocrystal↗

NASA Tech Briefs, November 2005

Topics covered include: Laser System for Precise, Unambiguous Range Measurements; Flexible Cryogenic Temperature and Liquid-Level Probes; Precision Cryogenic Dilatometer; Stroboscopic Interferometer for Measuring Mirror Vibrations; Some Improvements in H-PDLCs; Multiple-Bit Differential Detection of OQPSK; Absolute Position Encoders With Vertical Image Binning; Flexible, Carbon-Based Ohmic Contacts for Organic Transistors; GaAs QWIP Array Containing More Than a Million Pixels; AutoChem; Virtual Machine Language; Two-Dimensional Ffowcs Williams/Hawkings Equation Solver; Full Multigrid Flow Solver; Doclet To Synthesize UML; Computing Thermal Effects of Cavitation in Cryogenic Liquids; GUI for Computational Simulation of a Propellant Mixer; Control Program for an Optical-Calibration Robot; SQL-RAMS; Distributing Data from Desktop to Hand-Held Computers; Best-Fit Conic Approximation of Spacecraft Trajectory; Improved Charge-Transfer Fluorescent Dyes; Stability-Augmentation Devices for Miniature Aircraft; Tool Measures Depths of Defects on a Case Tang Joint; Two Heat-Transfer Improvements for Gas Liquefiers; Controlling Force and Depth in Friction Stir Welding; Spill-Resistant Alkali-Metal-Vapor Dispenser; A Methodology for Quantifying Certain Design Requirements During the Design Phase; Measuring Two Key Parameters of H3 Color Centers in Diamond; Improved Compression of Wavelet-Transformed Images; NASA Interactive Forms Type Interface - NIFTI; Predicting Numbers of Problems in Development of Software; Hot-Electron Photon Counters for Detecting Terahertz Photons; Magnetic Variations Associated With Solar Flares; and Artificial Intelligence for Controlling Robotic Aircraft.

Source record↗

Innovative, High-Pressure, Cryogenic Control Valve: Short Face-to-Face, Reduced Cost

A control valve that can throttle high-pressure cryogenic fluid embodies several design features that distinguish it over conventional valves designed for similar applications. Field and design engineers worked together to create a valve that would simplify installation, trim changes, and maintenance, thus reducing overall cost. The seals and plug stem packing were designed to perform optimally in cryogenic temperature ranges. Unlike conventional high-pressure cryogenic valves, the trim size can be changed independent of the body.

Wilkes, Karlin↗