Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Validation of a Computational Model for the SLS Core Stage Oxygen Tank Diffuser Concept and the Low Profile Diffuser - An Advanced Development Design for the SLS

The Low Profile Diffuser (LPD) project originated as an award from the Marshall Space Flight Center (MSFC) Advanced Development (ADO) office to the Main Propulsion Systems Branch (ER22). The task was created to develop and test an LPD concept that could produce comparable performance to a larger, traditionally designed, ullage gas diffuser while occupying a smaller volume envelope. Historically, ullage gas diffusers have been large, bulky devices that occupy a significant portion of the propellant tank, decreasing the tank volume available for propellant. Ullage pressurization of spacecraft propellant tanks is required to prevent boil-off of cryogenic propellants and to provide a positive pressure for propellant extraction. To achieve this, ullage gas diffusers must slow hot, high-pressure gas entering a propellant tank from supersonic speeds to only a few meters per second. Decreasing the incoming gas velocity is typically accomplished through expansion to larger areas within the diffuser which has traditionally led to large diffuser lengths. The Fluid Dynamics Branch (ER42) developed and applied advanced Computational Fluid Dynamics (CFD) analysis methods in order to mature the LPD design from and initial concept to an optimized test prototype and to provide extremely accurate pre-test predictions of diffuser performance. Additionally, the diffuser concept for the Core Stage of the Space Launch System (SLS) was analyzed in a short amount of time to guide test data collection efforts of the qualification of the device. CFD analysis of the SLS diffuser design provided new insights into the functioning of the device and was qualitatively validated against hot wire anemometry of the exterior flow field. Rigorous data analysis of the measurements was performed on static and dynamic pressure data, data from two microphones, accelerometers and hot wire anemometry with automated traverse. Feasibility of the LPD concept and validation of the computational model were demonstrated by the test data.

Brodnick, Jacob↗

Preliminary analysis of the benefits derived to US Air Force spacecraft from on-orbit refueling

This analysis was undertaken during FY-91 as a preliminary step to identify potential benefits from refueling Air Force satellites on orbit. Both economic and operational benefits were included. Operational benefits were related in economic terms to allow evaluation. All economic comparisons were made using FY-91 costs. An additional purpose of the effort was to identify the preferred mission parameters, for an on-orbit refueling system. A companion study was being concurrently conducted by SSD/XRP and NASA/JPL to develop a hardware concept for an on-orbit refueling system. The mass estimates for refueling missions obtained from the companion study were used in conducting the economic analyses of this benefits study. For this study, on-orbit refueling was based on the concept developed in the companion JPL study. The concept involves launching an S/C carrying fuel that would be transferred to another 'target' S/C which is already in orbit. The two S/C would then rendezvous, dock, and transfer fuel. Another fluid, such as a cryogenic, might be included if needed by the target S/C. The hardware concept for refueling was intended to minimize costs. The re-fueler S/C was designated to be expendable and would contain only the minimal capabilities. It would be launched into the orbit plane and altitude of the target S/C(s). The re-fueler S/C would rendezvous and dock with the target S/C and the fluid transfer would occur. When the refueling mission was completed, the re-fueler S/C would be ejected from the orbit. In order to optimize launch costs, some missions involved launching two re-fueler S/C on the LV. In this case the second re-fueler S/C would be placed in a storage orbit until needed.

Smith, Scott↗

Recent Developments in Transition-Edge Strip Detectors for Solar X-Rays

LMSAL and NIST are developing position-sensitive x-ray strip detectors based on Transition Edge Sensor (TES) microcalorimeters optimized for solar physics. By combining high spectral (E/ delta E approximately equals 1600) and temporal (single photon delta t approximately equals 10 micro s) resolutions with imaging capabilities, these devices will be able to study high-temperature (>l0 MK) x-ray lines as never before. Diagnostics from these lines should provide significant new insight into the physics of both microflares and the early stages of flares. Previously, the large size of traditional TESs, along with the heat loads associated with wiring large arrays, presented obstacles to using these cryogenic detectors for solar missions. Implementing strip detector technology at small scales, however, addresses both issues: here, a line of substantially smaller effective pixels requires only two TESs, decreasing both the total array size and the wiring requirements for the same spatial resolution. Early results show energy resolutions of delta E(sub fwhm) approximately equals 30 eV and spatial resolutions of approximately 10-15 micron, suggesting the strip-detector concept is viable.

Rausch, Adam J.↗

Development of a 50 mK - 10 K Flight-Worthy Vibration-Free Continuous Adiabatic Demagnetization Refrigerator

The cryogenics and fluids branch at NASA Goddard Space Flight Center is currently developing a flight-worthy vibration-free 50 mK to 10 K Continous Adiabatic Demagnetization Refrigerator (CADR) that will potentially serve as the cooling scheme for future space flight missions such as OST, LUVOIR, and other flagship missions. This 7 stage CADR will lift 6 microW of heat at its lowest stage and reject heat to a temperature platform at 10 K. A single stage 4 - 10 K flight-worthy ADR unit was recently demonstrated with an optimized cycle time of 132 seconds and a heat lift of ~13 mW at 4 K. We discuss the development progress and details of its desing in this presentation.

ADR↗

Lunar Sample Return Entry Systems Analysis

The Lunar Prospector and Clementine missions have revealed deposits of water-ice located at the South Pole-Aitken Basin of the lunar surface. Due to the scarce amount of previous successful sample return missions and the recent discovery of water-ice, the National Research Council (NRC) Decadal Survey recommended prioritizing the development of a Lunar Sample Return Mission Architecture. The NRC Decadal survey ranked the return of cryogenic samples that could potentially aid in current scientific investigations and identify sites for in-situ resource utilization to support future exploration missions. This study aims to identify the key technical challenges and operational constraints involved in returning cryogenic samples in pristine condition. A detailed classification of defined ground rules and assumptions, justification of mission events and high level functional requirements reinforces the proposed concept of operations. In support of the drafted architecture, a comprehensive analysis on design and environmental constraints are documented for the Earth return vehicle, sample container and thermal protection entry system. The design and thermal analysis is comprised of quantitative dimensions for mass and volume, flight performance parameters and thermal system performance limitations. Further refinement of the high level functional requirements is imperative for determining the optimal approach for returning cryopreserved lunar samples.

Lunar Sample Return↗

MegaMIR: The Megapixel Mid-Infrared Instrument for the Large Binocular Telescope Interferometer

The Megapixel Mid-infrared Instrument (MegaMIR) is a proposed Fizeau-mode camera for the Large Binocular Telescope operating at wavelengths between 5 and 28 micrometers. The camera will be used in conjunction with the Large Binocular Telescope Interferometer (LBTI), a cryogenic optical system that combines the beams from twin 8.4-m telescopes in a phase coherent manner. Unlike other interferometric systems, the co-mounted telescopes on the LBT satisfy the sine condition, providing diffraction-limited resolution over the 40" field of view of the camera. With a 22.8-m baseline, MegaMIR will yield 0.1" angular resolution, making it the highest resolution wide field imager in the thermal infrared for at least the next decade. MegaMIR will utilize a newly developed 1024 x 1024 pixel Si:As detector array that has been optimized for use at high backgrounds. This new detector is a derivative of the Wide-field Infrared Survey Explorer (WISE) low-background detector. The combination of high angular resolution and wide field imaging will be a unique scientific capability for astronomy. Key benefits will be realized in planetary science, galactic, and extra-galactic astronomy. High angular resolution is essential to disentangle highly complex sources, particularly in star formation regions and external galaxies, and MegaMIR provides this performance over a full field of view. Because of the great impact being made by space observatories like the Spitzer Space Telescope, the number of available targets for study has greatly increased in recent years, and MegaMIR will allow efficient follow up science.

ultraluminous galaxies↗

Optimization of a Packed Particle Magnetocaloric Refrigerator: A Combined Experimental and Theoretical Study

Magnetocaloric refrigeration has strong potential towards achieving high efficiency hydrogen liquefaction. Optimising parameters such as particle size and operating cycles can have a significant impact on liquefaction performance. Here, this work reports on a room temperature magnetocaloric refrigeration prototype designed with helium as the heat transfer fluid and packed particle Gd 0.8875 Ce 0.1025 Si 0.84 Cr 0.19 as the refrigerant. The temperature spans and cooling power with three different particle sizes at two different operating cycles were measured. A maximum temperature span of 16.7 K and a maximum cooling power of 8.6 W·kg –1 were obtained. Reduction of performance in the faster cycle was observed in larger particles due to insufficient thermal diffusion time and its implications for cryogenic temperatures are discussed. A numerical model was developed based on the experimentally observed variation of the temperature span and cooling power with particle size and cycle duration. This model was then used to study the competing effects of viscous dissipation and thermal diffusion for different particle sizes and cycle durations.

08 HYDROGEN↗

Purification of Propylene and Ethylene by a Robust Metal–Organic Framework Mediated by Host–Guest Interactions

Industrial purification of propylene and ethylene requires cryogenic distillation and selective hydrogenation over palladium catalysts to remove propane, ethane and/or trace amounts of acetylene. Here, we report the excellent separation of equimolar mixtures of propylene/propane and ethylene/ethane, and of a 1/100 mixture of acetylene/ethylene by a highly robust microporous material, MFM-520, under dynamic conditions. In situ synchrotron single crystal X-ray diffraction, inelastic neutron scattering and analysis of adsorption thermodynamic parameters reveal that a series of synergistic host-guest interactions involving hydrogen bonding and π⋯π stacking interactions underpin the cooperative binding of alkenes within the pore. Notably, the optimal pore geometry of the material enables selective accommodation of acetylene. The practical potential of this porous material has been demonstrated by fabricating mixed-matrix membranes comprising MFM-520, Matrimid and PIM-1, and these exhibit not only a high permeability for propylene (≈1984 Barrer), but also a separation factor of 7.8 for an equimolar mixture of propylene/propane at 298 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Primordial Inflation Polarization Explorer (PIPER): Current Status and Performance of the First Flight

The Primordial Inflation Polarization ExploreR (PIPER) is a balloon-borne instrument optimized to measure the polarization of the CMB at large angular scales. It will map 85% of the sky over a series of conventional balloon flights from the Northern and Southern hemispheres, measuring the B-mode polarization power spectrumover a range of multipoles from 2-300 covering both the reionization bump and the recombination peak, with sensitivity to measure the tensor-to-scalar ratio down to r = 0.007. PIPER will observe in four frequency bands centered at 200, 270, 350, and 600 GHz to characterize dust foregrounds. The instrument has background-limited sensitivity provided by fully cryogenic (1.7 K) optics focusing the sky signal onto kilo-pixel arrays of time-domain multiplexed Transition-Edge Sensor (TES) bolometers held at 100 mK. Polarization sensitivity and systematiccontrol are provided by front-end Variable-delay Polarization Modulators (VPMs). PIPER had its engineering flight in October 2017 from Fort Sumner, New Mexico. This papers outlines the major components in the PIPER system discussing the conceptual design as well as specific choices made for PIPER. We also report on the results of the engineering flight, looking at the functionality of the payload systems, particularly VPM, as well as pointing out areas of improvement.

Pawlyk, Samuel↗

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Analysis of Cryogenic Flow Through a Control Valve

The initial efforts to develop the capability to model valves used in rocket engine component testing at Stennis Space Center are documented. An axisymmetric model of a control valve with LN2 as the working fluid was developed. The goal was to predict the effect of change in the plug/sear region of the valve prior to testing. The valve flow coefficient was predicted for a range of plug positions. Verification of the calculations was carried out to quantify the uncertainty in the numerical answer. The modeled results compared well qualitatively to experimental trends. Additionally, insights into the flow processes in the valve were obtained. Benefits from the verification process included the ability to use coarser grids and insight into ways to reduce computational time by using double precision accuracy and non-integer grid ratios. Future valve modeling activities will include shape optimization of the valve/seat region and dynamic grid modeling.

Danes, Russell↗

On the Relationship Between Schottky Barrier Capacitance and Mixer Performance at Cryogenic Temperatures

The flat-band voltage is the Schottky junction voltage required to shrink the depletion width to zero. At cryogenic temperatures, mixer diodes are generally biased and/or pumped beyond the flat-band condition to minimize conversion loss and noise figure. This occurs despite the presumed sharp increase in junction capacitance near flat-band, which should instead limit mixer performance. Past moderate forward bias, the diode C-V relationship is difficult to measure. A simple analytic expression for C(V) is usually used to model and predict mixer performance. This letter provides experimental data on C(V) at 77 K based on a microwave measurement and modeling technique. Data is also provided on the conversion loss of a singly balanced mixer optimized for 77 K operation. The connection between junction capacitance, flat-band potential, and conversion loss is examined. It is shown that the analytic expression greatly overestimates the junction capacitance that occurs as flat-band is approached.

Romanofsky, Robert R.↗

Second-Generation Micro-Spec: A Compact Spectrometer for Far-Infrared and Submillimeter Space Missions

Micro-Spec is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ≈ 10-sq.cm chip through the use of superconducting microstrip transmission lines on a single- crystal silicon substrate. The second generation of Micro-Spec is being designed to operate with a spectral re- solution of at least 512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA's experiment for cryogenic large-aperture intensity mapping called EXCLAIM. EXCLAIM will be a balloon-borne telescope that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5 and it will be the first demonstration of the Micro-Spec technology in a space-like environment. This work reviews the status of the Micro-Spec design for the EXCLAIM telescope, with emphasis on the spectrometer's two-dimensional diffractive region, through which light of different wavelengths is focused on kinetic inductance detectors along the instrument focal plane. An optimization process is used to generate a geometrical configuration of the diffractive region that satisfies l range and performance. An initial optical design optimized for n terms of geometric layout, spectral purity and efficiency.

Cataldo, Giuseppe↗

Second-generation Micro-Spec: Spectrometer Design for the Experiment for Cryogenic Large-Aperture Intensity Mapping

Micro-Spec (μ-Spec) is a direct-detection spectrometer that integrates all the components of a diffraction-grating spectrometer onto a ∼10-cm2 chip using superconducting microstrip transmission lines on a single-crystal silicon substrate. The second-generation μ-Spec has been designed to operate with a spectral resolution of ∼512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA’s EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM). EXCLAIM will be a high-altitude balloon mission that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5. EXCLAIM will be the first demonstration of the μ-Spec technology in a space-like environment. This work reviews the status of the μ-Spec design for the EXCLAIM instrument, with emphasis on the spectrometer’s two-dimensional diffractive region, through which light of different wavelengths is focused on microwave kinetic inductance detectors (MKIDs) along the spectrometer focal plane. An optimization process generates a geometrical configuration of the diffractive region that satisfies specific requirements on size, operating spectral range and performance. An initial optical design optimized for EXCLAIM is presented in terms of geometric layout, spectral purity and efficiency.

Giuseppe Cataldo↗

Optimization of the light detection system of the ICARUS detector

The Short Baseline Neutrino (SBN) Program at Fermilab is designed to investigate short-baseline neutrino oscillations and test the hypothesis of sterile neutrinos, motivated by several experimental anomalies observed over the past decades. Within this program, the ICARUS experiment plays a key role. It employs the world’s largest Liquid Argon Time Projection Chamber (LArTPC) and serves as the farthest and most sensitive SBN detector for studying muon and electron neutrino oscillations. A crucial subsystem of the ICARUS detector is the Light Detection System (LDS), which captures the prompt scintillation light produced by neutrino interactions in the 600-ton active liquid Argon volume. This system provides precise timing information that is essential for event reconstruction, the trigger system, and cosmic background rejection. The LDS is composed of 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), operating under cryogenic conditions ($\sim 87 \ K$) inside the detector’s cryostats. During the detector’s operation at FNAL, a degradation in PMT gain has been observed, attributed to aging under low-temperature conditions. In collaboration with ICARUS teams from INFN Pavia and Catania, I developed an experimental setup to study the temperature-dependent behavior of the PMTs, performing gain measurements both at room temperature and down to $-70°C$ using a climatic chamber at INFN Catania. The results indicate that while the PMTs maintain stable gain at room temperature, a significant and permanent gain reduction occurs at low temperatures. Although $-70°C$ is still warmer than liquid Argon temperatures, the findings clearly demonstrate a gain-dependent performance degradation. The thesis also discusses mitigation strategies implemented in the ICARUS detector to address this issue and presents a simplified model to describe and simulate the observed behavior.

Saia, Clara [Catania U.] (ORCID:0009000464102417)↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

Application of transport-based metric for continuous interpolation between cryo-EM density maps

Cryogenic electron microscopy (cryo-EM) has become widely used for the past few years in structural biology, to collect single images of macromolecules "frozen in time". As this technique facilitates the identification of multiple conformational states adopted by the same molecule, a direct product of it is a set of 3D volumes, also called EM maps. To gain more insights on the possible mechanisms that govern transitions between different states, and hence the mode of action of a molecule, we recently introduced a bioinformatic tool that interpolates and generates morphing trajectories joining two given EM maps. This tool is based on recent advances made in optimal transport, that allow efficient evaluation of Wasserstein barycenters of 3D shapes. As the overall performance of the method depends on various key parameters, including the sensitivity of the regularization parameter, we performed various numerical experiments to demonstrate how MorphOT can be applied in different contexts and settings. Finally, we discuss current limitations and further potential connections between other optimal transport theories and the conformational heterogeneity problem inherent with cryo-EM data.

3D shapes↗

Quantitative Low-Field 19 F Nuclear Magnetic Resonance Analysis of Carbonyl Groups in Pyrolysis Oils

Pyrolysis bio-oils, one of the products of lignocellulosic biomass pyrolysis, have the potential to be widely used as fuels. The chemical composition of bio-oils is very complicated as they contain hundreds, if not thousands, of different, mostly oxygen-containing, compounds with a wide distribution of physical properties, chemical structures, and concentrations. Detailed knowledge of bio-oil composition is crucial for optimizing both the pyrolysis processes and for any subsequent upgrading into a more viable fuel resource. Here we report the successful use of low-field, or benchtop, nuclear magnetic resonance (NMR) spectrometers in the analysis of pyrolysis oils. Pyrolysis oils from four different feedstocks were derivatized and analyzed using 19 F NMR techniques. The NMR results compare favorably with titrations for total carbonyl content. In addition, the benchtop NMR spectrometer proves able to reveal key spectral features, thus allowing the quantification of different carbonyl groups, such as aldehydes, ketones and quinones. Benchtop NMR spectrometers are typically compact, cheaper than their superconducting counterparts and do not require cryogens. Their use will make NMR analysis of pyrolysis oils easier and more accessible to a wide range of different potential users.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗