At least 433 records · Page 24

Lessons from commissioning of the cryogenic system for the Short-Baseline Neutrino Detector at Fermilab

Results from commissioning and first year of operations of the cryogenic system of the Short-Baseline Neutrino Detector (SBND) and its membrane cryostat installed at the Fermi National Accelerator Laboratory are described. The SBND detector is installed in a 200 m3 membrane cryostat filled with liquid argon, which serves both as target and as active media. For the correct operation of the detector, the liquid argon must be kept in very stable thermal conditions while the contamination of electronegative impurities must be consistently kept at the level of small fractions of parts per billion. The detector is operated in Booster Neutrino Beams (BNB) at Fermilab for the search of sterile neutrinos and measurements of neutrino-argon cross sections. The cryostat and the cryogenic systems also serve as prototypes for the much larger equipment to be used for the LBNF/DUNE experiment. Since its installation in 2018-2023 and cooldown in spring of 2024, the cryostat and the cryogenic system have been commissioned to support the detector operations. The lessons learned through installation, testing, commissioning, cooldown, and initial operations are described.

Geynisman, Michael [Fermilab]↗

Disruption Mitigation System Developments and Design for ITER

A disruption mitigation system (DMS) is under design for ITER to inject sufficient material deeply into the plasma for rapid plasma thermal shutdown and collisional suppression of any resulting runaway electrons. Progress on the development and design of both a shattered pellet injector (SPI) that produces large solid cryogenic pellets to provide reliable deep penetration of material and a fast opening high flow rate gas valve for massive gas injection (MGI) is presented. Cryogenic pellets of deuterium and neon up to 25 mm in size have been formed and accelerated with a prototype injector and a full scale prototype MGI valve is now in testing. Implications of the design with respect to response time and reliability at the proposed injector locations on ITER are discussed.

Baylor, Larry↗

Evaluation of two designs for cryogenic insulation

Shingle-type, crinkled, aluminized polyethylene ester is thermally and structurally tested for cryogenic insulation. Insulation systems require thermal efficiency with minimum weight, and the ability to withstand vibration, acceleration, and rapid pressure drops.

Getty, R. C.↗

HIGH Q0 AT MEDIUM FIELDS IN Nb3Sn SRF CAVITIES AT 4.2 K

Nb3Sn has proven itself to be a very promising alternative SRF material. With twice the critical temperature of niobium cavities, 1.3 GHz Nb3Sn cavities can achieve quality factors on the order of 1010 even at 4.2 K, significantly reducing cryogenic infrastructure and operational costs. In addition, its large predicted superheating field may allow for maximum accelerating gradients up to twice that of niobium for high energy applications. In this work, we report on new cavity results fromthe CornellNb3Sn SRF program demonstrating a significant improvement in the maximum field achieved with high Q0 in a Nb3Sn cavity. At 4.2 K, accelerating gradients above 16MV/m were obtainedwith Q0 of 8 × 109, showing the potential of this material for future applications. In addition to this result, current limitations are discussed.

Nb3Sn↗

Purification of Argon from a Diluted Stream

We report on the design, performance and commissioning of a cryogenic distillation column for low radioactivity underground argon purification that has been constructed at Fermi National Accelerator Laboratory. The plant accepts a mixture of argon, helium, and nitrogen with low argon concentration and is designed to return pure argon with a nitrogen contamination less than 10 ppm. During the commissioning, the distillation column in a continuous mode produced argon 99.9% pure. After running in batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The argon production rate was about 1 kg/day.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic rf test of the first SRF cavity etched in an rf Ar/Cl 2 plasma

An apparatus and a method for etching of the inner surfaces of superconducting radio frequency (SRF) accelerator cavities are described. The apparatus is based on the reactive ion etching performed in an Ar/Cl 2 cylindrical capacitive discharge with reversed asymmetry. To test the effect of the plasma etching on the cavity rf performance, a 1497 MHz single cell SRF cavity was used. The single cell cavity was mechanically polished and buffer chemically etched and then rf tested at cryogenic temperatures to provide a baseline characterization. The cavity’s inner wall was then exposed to the capacitive discharge in a mixture of Argon and Chlorine. The inner wall acted as the grounded electrode, while kept at elevated temperature. The processing was accomplished by axially moving the dc-biased, corrugated inner electrode and the gas flow inlet in a step-wise manner to establish a sequence of longitudinally segmented discharges. The cavity was then tested in a standard vertical test stand at cryogenic temperatures. The rf tests and surface condition results, including the electron field emission elimination, are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

R&D ERL: HOM Absorbers

Several future accelerator projects at the Relativistic Heavy Ion Collider (RHIC) are based on Energy Recovery Linacs (ERL) with high-charge high-current electron beams. Their stable operation mandates effective higher-order-mode (HOM) damping. The development of HOM dampers for these projects is pursued actively at this laboratory. A strong HOM damping was experimentally demonstrated both at room- and at superconducting- (SC) temperatures in a prototype R&D five-cell niobium SRF cavity with ferrite dampers. A novel type of ferrite damper over a ceramic break for a R&D SRF electron gun also was developed. For future SRF linacs longer cryomodules comprising of multiple superconducting cavities with reasonably short transitions between them are planned. In such a configuration, the dampers, located closer to the cavities, will be at cryogenic temperatures; this will impose additional constraints and complications. Two room-temperature mock-up five-cell copper cavities were used to study various damper configurations. This paper presents results of simulations and measurements for several configurations.

43 PARTICLE ACCELERATORS↗

Nanoparticulate gellants for metallized gelled liquid hydrogen with aluminum

Gelled liquid hydrogen was experimentally formulated using sol-gel technology. As a follow-on to work with cryogenic simulants, hydrogen was gelled with an alkoxide material: BTMSE. Initial results demonstrated that gellants with a specific surface area of 1000 m(exp 2)/g could be repeatably fabricated. Gelled hexane and metallized gelled hexane (with 13.8-wt% Al) were produced. Propellant settling testing was conducted for acceleration levels of 2 to 10 times normal gravity and a minimum gellant percentage was determined for stable gelled hexane and metalized gelled hexane. A cryogenic capillary rheometer was also designed, constructed, and used to determine the viscosity of gelled hydrogen. Small volumes of liquid hydrogen were gelled with a 7- to 8-wt% gellant level. The gelled H2 viscosity was 1.5 to 3.7 times that of liquid hydrogen: 0.048 to 0.116 mPa-s versus 0.03 mPa-s for liquid H2 (at 16 K and approximately 1 atm pressure).

Palaszewski, Bryan↗

Formation of particulates by ion bombardment of cryogenic ice mixtures

An analysis of the particulates which form upon the bombardment of a gaseous mixture reflecting cosmic molecular abundances with H2(+) ions accelerated at 350 keV. The model of Black and Dalgarno (1977) for the Zeta Oph cloud and an observational determination of the interstellar Ar abundances (Simpson et al., 1986) are used to determine the abundances of the gas mixture. The characteristics of the resulting residue are examined, including photographs and absorbance spectra. The possible astrophysical implications of the experiment are discussed.

Wdowiak, T. J.↗

The CLAS12 Torus Detector Magnet at Jefferson Laboratory

The CLAS12 Torus is a toroidal superconducting magnet, which is part of the detector for the 12-GeV accelerator upgrade at Jefferson Laboratory (JLab). The coils were wound/fabricated by Fermilab, with JLab responsible for all other parts of the project scope, including design, integration, cryostating the individual coils, installation, cryogenics, I&C, etc. This paper provides an overview of the CLAS12 Torus magnet features and serves as a status report of its installation in the experimental hall. Completion and commissioning of the magnet is expected in 2016.

43 PARTICLE ACCELERATORS↗

Characterization of Cs 3 Sb photocathodes at cryogenic temperatures

Here, we report measurements of quantum efficiency (QE) and mean transverse energy (MTE) from Cs 3 Sb photocathodes in a wide range of photon energies at both room and cryogenic temperatures. Our measurements show a strong temperature dependence of MTE even at photon energies well above threshold, indicating the presence of strong inelastic scattering of excited electrons during transport before emission into vacuum. We also demonstrate a cathode cooling method that largely preserves the QE while reducing MTE, allowing us to achieve MTEs as low as 58 meV with 3% QE in green light from Cs 3 Sb photocathodes. Our results are crucial for producing brighter electron beams for various photoinjector applications like ultrafast electron diffraction and microscopy, x-ray free-electron lasers, and particle colliders.

36 MATERIALS SCIENCE↗

A New Four-Barrel Pellet Injection System for the TJ-II Stellarator

A new pellet injection system for the TJ-II stellarator has been developed/constructed as part of a collaboration between the Oak Ridge National Laboratory (ORNL) and the Centro de Investigaciones Energ ticas, Medioambientales y Tecnol gicas (CIEMAT). ORNL is providing most of the injector hardware and instrumentation, the pellet diagnostics, and the pellet transport tubes; CIEMAT is responsible for the injector stand/interface to the stellarator, cryogenic refrigerator, vacuum pumps/ballast volumes, gas manifolds, remote operations, plasma diagnostics, and data acquisition. The pellet injector design is an upgraded version of that used for the ORNL injector installed on the Madison Symmetric Torus (MST). It is a four-barrel system equipped with a cryogenic refrigerator for in situ hydrogen pellet formation and a combined mechanical punch/propellant valve system for pellet acceleration (speeds ~100 to 1000 m/s). On TJ-II, it will be used as an active diagnostic and for fueling. To accommodate the plasma experiments planned for TJ-II, pellet sizes significantly smaller than those typically used for the MST application are required. The system will initially be equipped with four different pellet sizes, with the gun barrel bores ranging between ~0.5 to 1.0 mm. The new system is almost complete and is described briefly here, highlighting the new features added since the original MST injector was constructed. Also, the future installation on TJ-II is reviewed.

diagnostic↗

Vertical Magnetic Measurement System Commis-sioning and First Measurements of the First Full-Length Prototype Quadrupole Magnet for the LHC Hi-Lumi Upgrade

This paper will report the commissioning of the vertical magnetic measurement system and the warm (room temperature) and cold (cryogenic) magnetic field measurements of the first full-length (4.2 m) quadrupole built by the US Accelerator Upgrade Project (AUP) project (formerly the LARP collaboration) for the high luminosity upgrade of the Large Hadron Collider at CERN. The magnet, designated MQXFAP2, is a prototype preceding production for the AUP Accelerator Upgrade Project (AUP). AUP will provide ten 8.4 m superconducting insertion region (IR) quadrupoles for the Hi-Lumi Upgrade. The 8.4 m quadrupoles will be built by assembling two 4.2 m magnets in a single cryostat. Agreement between BNL’s and LBNL’s warm measurement data has indicated that the upgraded vertical magnetic measurement system at BNL is ready for MQXFA magnet production testing. The cold magnetic measurement has been performed and preliminary data analysis has been conducted. The measured data indicates that the MQXFAP2 magnet has good magnetic field which meets the preliminary MQXFA magnet acceptance criteria.

43 PARTICLE ACCELERATORS↗

The high Beta cryo-modules and the associated cryogenic system for the HIE-ISOLDE upgrade at CERN

The major upgrade of the energy and intensity of the existing ISOLDE and REX-ISOLDE radioactive ion beam facilities at CERN requires the replacement of most of the existing ISOLDE post-acceleration equipment by a superconducting linac based on quarter-wave resonators housed together with superconducting solenoids in a series of four high-β and two low-β cryo-modules. As well as providing optimum conditions for physics, the cryo-modules need to function under stringent vacuum and cryogenic conditions. We present the detail design and expected cryogenic performance of the high- β cryo-module together with the cryogenic supply and distribution system destined to service the complete superconducting linac.

43 PARTICLE ACCELERATORS↗

Design and construction of the main linac module for the superconducting energy recovery linac project at Cornell

Cornell University has been designing and building superconducting accelerators for various applications for more than 50 years. Currently, an energy-recovery linac (ERL) based synchrotron-light facility is proposed making use of the existing CESR facility. As part of the phase 1 R and D program funded by the NSF, critical challenges in the design were addressed, one of them being a full linac cryo-module. It houses 6 superconducting cavities- operated at 1.8 K in continuous wave (CW) mode - with individual HOM absorbers and one magnet/ BPM section. Pushing the limits, a high quality factor of the cavities (2⋅10{sup 10}) and high beam currents (100 mA accelerated plus 100 mA decelerated) are targeted. We will present the design of the main linac cryo-module (MLC) being finalized recently, its cryogenic features and report on the status of the fabrication which started in late 2012.

43 PARTICLE ACCELERATORS↗

Development of the cryogenic system of AEgIS at CERN

The AEgIS (Antimatter Experiment: Gravity, Interferometry, Spectroscopy) experiment is located at the antiproton decelerator complex of CERN. The main goal of the experiment is to perform the first direct measurement of the Earth’s gravitational acceleration on antihydrogen atoms within 1% precision. The antihydrogen is produced in a cylindrical Penning trap by combining antiprotons with positrons. To reach the precision of 1%, the antihydrogen has to be cooled to 100 mK to reduce its random velocity. A dilution refrigerator is selected to deliver the necessary cooling capacity of 100 μW at 50 mK. The AEgIS cryogenic system basically consists of cryostats for a 1-T and for a 5-T superconducting magnet, a central region cryostat, a dilution refrigerator cryostat and a measurement cryostat with a Moiré deflectometer to measure the gravitational acceleration. In autumn 2012, the 1-T cryostat, 5-T cryostat and central region cryostat were assembled and commissioned. The apparatus is cooled down in eight days using 2500 L of liquid helium and liquid nitrogen. During operation, the average consumption of liquid helium is 150 L⋅day{sup −1} and of liquid nitrogen 5 L⋅day{sup −1}. The temperature sensors at the Penning traps measured 12 K to 18 K, which is higher than expected. Simulations show that this is caused by a bad thermalization of the trap wiring. The implementation of the sub-kelvin region is foreseen for mid-2015. The antihydrogen will be cooled down to 100 mK in an ultra-cold trap consisting of multiple high-voltage electrodes made of sapphire with gold plated electrode sectors.

43 PARTICLE ACCELERATORS↗

Thermal evolution of ferroelectric behavior in epitaxial Hf 0.5 Zr 0.5 O 2

In this paper, we report a cryogenic-temperature study on the evolution of the ferroelectric properties of epitaxial Hf 0.5 Zr 0.5 O 2 thin films on silicon. Wake-up, endurance, and fatigue of these films are found to be intricately correlated, strongly hysteretic, and dependent on available thermal energy. Field-dependent measurements reveal a decrease in polarization with temperature, which has been determined not to be an intrinsic change of the material property, rather a demonstration of the increase in the coercive bias of the material. Our findings suggest that a deficiency in thermal energy suppresses the mobility of defects presumed to be oxygen vacancies during wake-up and trapped injected charge during fatigue, which is responsible for polarization evolution during cycling. This permits accelerated wake-up and fatigue effects at high temperatures where thermal energy is abundant but delays these effects at cryogenic temperatures.

36 MATERIALS SCIENCE↗

Novel techniques and devices for in-situ film coatings of long, small diameter tubes or elliptical and other surface contours

In this study, devices and techniques that can, via physical vapor deposition,coat various surface contours or very long small aperture pipes, are described. Recently, a magnetron mole was developed in order to in-situ coat accelerator tube sections of the Brookhaven National Lab relativistic heavy ion collider that have 7.1 cm diameter with access points that are 500 m apart, for copper coat the accelerator vacuum tube in order to alleviate the problems of unacceptable ohmic heating and of electron clouds. A magnetron with a 50 cm long cathode was designed fabricated and successfully operated to copper coat a whole assembly containing a full-size, stainless steel, cold bore, of the accelerator magnet tubing connected to two types bellows, to which two additional pipes made of accelerator tubing were connected. The magnetron is mounted on a carriage with spring loaded wheels that successfully crossed bellows and adjusted for variations in vacuum tube diameter, while keeping the magnetron centered. Electrical power and cooling water were fed through a cable bundle. The umbilical cabling system, which is enclosed in a flexible braided metal sleeve, is driven by a motorized spool. To increase cathode lifetime, movable magnet package was developed, and thickest possible cathode was made, with a rather challenging target to substrate distance of less than 1.5 cm. Optimized process to ensure excellent adhesion was developed. Coating thickness of 10 μm Cu passed all industrial tests and even exceeded maximum capability of a 12 kg pull test fixture. Room temperature radio frequency (RF) resistivity measurement indicated that 10 μm Cu coated stainless steel accelerator tube has conductivity close to copper tubing. Work is in progress to repeat the RF resistivity measurement at cryogenic temperatures. Over 20 years ago, a device using multi axis robotic manipulators controlling separate robotic assemblies resulted in nine-axes of motion combined with conformal shape of the cathodes that can adapt to various curved surface contours was developed and successfully used for depositing optical coating on aircraft canopies. The techniques can be utilized for in situ coating of elliptical and other surface contour RF cavities and long beam pipes with thick superconducting films. Plans are to incorporate ion assisted deposition in those techniques for attaining dense, adherent and defect free coatings.

43 PARTICLE ACCELERATORS↗